확장 T-method에 의한 환상식 덕트시스템 해석 (Analysis of loop duct system by extended T-method)

  • 이승철;문종선;이재헌
    • 설비공학논문집
    • /
    • 제10권4호
    • /
    • pp.389-397
    • /
    • 1998
  • A loop duct system is often found in a VAV-HVAC(variable air volume heating, ventilating and air conditioning) design. It is known that the simple T-method is not be applicable to the loop duct system and cannot be used to calculate the flow rate and the pressure drop at each duct section of the loop duct system. In this paper, the extended T-method has been developed and it is found to be applicable to the loop duct system to which the simple T-method cannot be applied. The validity of the extended T-method has been verified by using to solve for a simple, ideal loop duct system for which there exists analytical solution. In addition, the extended T-method is employed to compute the loop duct system of a real building with an area of 380$m^2$. The results show that the computed flow rate at the exit differs from the designed flow rate by a range of -13.6~43.5 %. Consequently, three design factors must be adjusted in order that the flow rate may be balanced. These include the duct sizes, in terms of their lengths and diameters, the sub-duct locations and the positioning of damper which is found upstream of the exit duct.

  • PDF

복합 덕트시스템의 유량분배에 관한 1차원 해석의 적합성 (Adaptability of one-dimensional analysis for the flow distribution of a complex duct system)

  • 이승철;이재헌
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.579-587
    • /
    • 1999
  • The flow distribution characteristics in a complex duct system have been investigated in this paper by three means, namely experimental measurement, numerical simulation and the Extended T-method analysis. While the exit flow rates predicted by the three-dimensional CFD calculation and those given by the experiment show a close agreement, the results from the one-dimensional Extended T-method are found to differ from the experiment by -22.2% to 26.3% for the various exits. These discrepancies may be attributed to the underlying limitation concerning the fitting loss coefficients, which assume that the flow in front of the fittings is fully developed. It is proposed that, in order to analyse the three-dimensional flow distributions in a complex duct system by one-dimensional analysis such as the Extended T-method, further Improvements to the fitting loss coefficients should be made.

  • PDF

전달함수를 이용한 2단 덕트 시스템에서의 연소불안정 해석 (Analysis of Combustion Instabilities in a 2-stage Duct System using Transfer Functions)

  • 김선영;김대식
    • 한국분무공학회지
    • /
    • 제26권4호
    • /
    • pp.182-188
    • /
    • 2021
  • In this paper, using a transfer function-based analytical model, major factors influencing the acoustics and combustion instability in a two-stage duct system composed of a nozzle and a combustor were derived and their quantitative effects were evaluated. From the acoustic analysis, it was confirmed that the change in reflection coefficient and mean flow could have a great influence on the instability growth rate, and the area ratio and speed of sound ratio between the nozzle and the combustor are also key parameters to determine combustion instability as well as flame transfer functions.

Sigma-Pi 신경망을 이용한 틸트덕트 무인기의 제어기 설계연구 (Control Law Design for a Tilt-Duct Unmanned Aerial Vehicle using Sigma-Pi Neural Networks)

  • 강영신;박범진;조암;유창선
    • 항공우주시스템공학회지
    • /
    • 제11권1호
    • /
    • pp.14-21
    • /
    • 2017
  • 매우 큰 정안정성($C_{L{\alpha}}$)을 갖는 틸트덕트 운동모델에 대해 선형 파라미터를 갖는 Sigma-Pi 신경망(SPNN) 제어법칙을 적용하였다. 기존의 비례적분미분(PID) 제어기는 매우 큰 정안정성을 갖는 운동모델이 갖는 강한 기수숙임 문제를 해결하기 어려웠고 이로인해 제어성능을 높일 수 없었다. 이와 달리 외부루프와 내부루프에 모두 적용된 SPNN 제어기는 동역학역변환 및 모델오차를 줄일 수 있는 의사적응제어 명령을 이용해서 과도한 안정성을 개선할 수 있었다. 이를 검증하기 위해서 경로점 추종 시뮬레이션을 이용해서 PID제어 성능과 SPNN제어 성능을 비교하였다.

HCFC-123의 수평 평활관내 응축 전열 특성에 관한 연구 (Condensation Heat Transfer Characteristics of HCFC - 123 inside Horizontal Smooth Tube)

  • 권옥배;오후규;오종택;김성규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권3호
    • /
    • pp.24-32
    • /
    • 1993
  • Experimental data on the heat transfer characteristics of HCFC-123 and CFC-11 during condensation in horizontal smooth tube are presented. The experimental apparatus consisted of a closed working fluid loop, coolant loop, and measuring system. The major components of the working fluid loop made of a refrigerant pump, boiler, superheater, refrigerant flow meter, receiver and test section. The tube-in-tube type test section was made of smooth tube which were constructed form 9.52 mm outer diameter of smooth copper tube with 50 mm outside diameter of PVC tube duct. The ranges of parameter, such as refrigerant mass velocity, coolant flow rate, and quality were 90-325kg/($m^2$.s), 60-360kg/h, 5-95% respectively. Data were obtained under steady state condition for annular flow. As a result of these, the condensation heat transfer coefficients for HCFC-123 were slightly lower than those of CFC-11 from 8% to 15% inside horizontal smooth tube. Furthermore, a new generalized correlation for the heat transfer coefficients of HCFC-123 and CFC-11 during condensation inside horizontal smooth tube is proposed.

  • PDF

적응 능동소음제어를 위한 오차경로 인식 방법을 통한 filtered-X LMS 알고리듬 (A Filtered-X LMS Algorithm by New Error Path Identification Method for Adaptive Active Noise Control)

  • 권기룡;송규익;김덕규;이건일
    • 한국통신학회논문지
    • /
    • 제19권8호
    • /
    • pp.1528-1535
    • /
    • 1994
  • 본 논문에서는 적응 능동소음제어를 위한 새로운 오차경로 인식 방법을 통한 filtered-X LMS(least mean square) 알고리듬을 제안하였다. 제안한 알고리듬에서는 3개의 마이크로폰과 이중루프제어를 이용하여 오차경로의 전달 특성을 온라인으로 정확히 인식하도록 하였다. 덕트를 통한 소음이 정형파인 경우와 실제 공조기의 소음에 대하여 컴퓨터 시뮬레이션을 각각 수행한 결과, 제안한 방식은 입력소음에 비하여 각각 평균 29.1dB 및 10.4dB 정도의 소음레벨이 감쇠됨을 확인하였다. 이는 Eriksson의 방법보다 각각 평균 0.5dB 및 2.5dB 정도 개선된 것이다.

  • PDF

고온 태양열 공기식 흡수기의 충진재 변화에 따른 열전달 및 압력강하 성능 분석 (Honeycomb and Laminated Mesh as Open Volumetric Solar Receiver : Performance of Heat Transfer and Pressure Drop)

  • 조자현;이주한;강경문;서태범
    • 설비공학논문집
    • /
    • 제20권11호
    • /
    • pp.760-766
    • /
    • 2008
  • The characteristics of heat transfer and pressure drop of several different porous materials which can be used as inserts inside solar volumetric air receivers were experimentally investigated. Generally, porous materials were inserted into solar volumetric air receivers to increase the thermal performance. In the present work, honeycomb (diameter: 100 mm, thickness: 30 mm), laminated mesh (diameter: 100 mm, thickness: 1 mm) are considered as the inserts for the experiment. The experimental apparatus consists mainly of a cylindrical ceramic duct as a receiver and an electric heater as an energy source. This system is an intake open loop, which used as air of working fluid. The temperatures inside the ceramic tube are measured by thermocouples, which are installed at each layer of the porous materials. The pressure-drop experimental apparatus is fabricated alike the above experimental equipment. An acrylic tube is used like as the ceramic tube, which has the same specifications of the ceramic tube. The pressure drop of porous materials inserted in the acrylic tube is measured between front and rear of those by transmitter. The results show that the laminated mesh surpasses the honeycomb of heat transfer and pressure drop increase as the porous material thickness and Reynolds number.

M/W 중계장치 대체를 위한 B-WLL 및 광전송 장치의 품질과 경제성 분석에 대한 연구 (A Study on Quality and Economical Analysis of B-WLL and Optical Transmission Systems for Substituting M/W Relay System)

  • 서경환;최용석
    • 한국전자파학회논문지
    • /
    • 제15권9호
    • /
    • pp.809-819
    • /
    • 2004
  • 본 논문에서는 M/W 중계 주파수의 증설 또는 신규 수용을 가급적 배제하고 필요 회선을 B-WLL 또는 광통신망으로 대체 가능성을 품질 및 경제성 측면에서 분석하였다. 품질 목표에서는 매체간 비교를 위한 전제조건 및 분석방법을 도출하였다. 그리고 E1급을 기준으로 비트오율(BER) $10^{-6}$ 을 만족하도록 기준을 설정하고, 매체별로 가용도에 대한 거리를 산출하였다. 또한 경제성 측면에서는 광통신, M/W, B-WLL 시스템의 기본 구성 단위를 기반으로 서비스 기간, 장비용량, 전송거리, 대용량 전송으로 분류하고 다양한 광전송 회선 및 B-WLL 구성에 대해 분석하였다. 목표 가용도를 99.999 %로 설정시 B-WLL로 M/W를 반경 1.6 km까지 대체 가능하다는 것을 알 수 있었다. 또한 광으로 대체할 경우, 광 관로용의 전주 임대 시에는 서비스 기간에 관계없이 M/W보다 경제성이 있으며, 광 관로 자체를 굴착할 경우에는 고려 방법 중의 어느 경우에 대해서도 경제성이 없는 것으로 판명되었다.