• Title/Summary/Keyword: Loop duct system

Search Result 8, Processing Time 0.019 seconds

Analysis of loop duct system by extended T-method (확장 T-method에 의한 환상식 덕트시스템 해석)

  • 이승철;문종선;이재헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.389-397
    • /
    • 1998
  • A loop duct system is often found in a VAV-HVAC(variable air volume heating, ventilating and air conditioning) design. It is known that the simple T-method is not be applicable to the loop duct system and cannot be used to calculate the flow rate and the pressure drop at each duct section of the loop duct system. In this paper, the extended T-method has been developed and it is found to be applicable to the loop duct system to which the simple T-method cannot be applied. The validity of the extended T-method has been verified by using to solve for a simple, ideal loop duct system for which there exists analytical solution. In addition, the extended T-method is employed to compute the loop duct system of a real building with an area of 380$m^2$. The results show that the computed flow rate at the exit differs from the designed flow rate by a range of -13.6~43.5 %. Consequently, three design factors must be adjusted in order that the flow rate may be balanced. These include the duct sizes, in terms of their lengths and diameters, the sub-duct locations and the positioning of damper which is found upstream of the exit duct.

  • PDF

Adaptability of one-dimensional analysis for the flow distribution of a complex duct system (복합 덕트시스템의 유량분배에 관한 1차원 해석의 적합성)

  • 이승철;이재헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.579-587
    • /
    • 1999
  • The flow distribution characteristics in a complex duct system have been investigated in this paper by three means, namely experimental measurement, numerical simulation and the Extended T-method analysis. While the exit flow rates predicted by the three-dimensional CFD calculation and those given by the experiment show a close agreement, the results from the one-dimensional Extended T-method are found to differ from the experiment by -22.2% to 26.3% for the various exits. These discrepancies may be attributed to the underlying limitation concerning the fitting loss coefficients, which assume that the flow in front of the fittings is fully developed. It is proposed that, in order to analyse the three-dimensional flow distributions in a complex duct system by one-dimensional analysis such as the Extended T-method, further Improvements to the fitting loss coefficients should be made.

  • PDF

Analysis of Combustion Instabilities in a 2-stage Duct System using Transfer Functions (전달함수를 이용한 2단 덕트 시스템에서의 연소불안정 해석)

  • Kim, Seonyeong;Kim, Daesik
    • Journal of ILASS-Korea
    • /
    • v.26 no.4
    • /
    • pp.182-188
    • /
    • 2021
  • In this paper, using a transfer function-based analytical model, major factors influencing the acoustics and combustion instability in a two-stage duct system composed of a nozzle and a combustor were derived and their quantitative effects were evaluated. From the acoustic analysis, it was confirmed that the change in reflection coefficient and mean flow could have a great influence on the instability growth rate, and the area ratio and speed of sound ratio between the nozzle and the combustor are also key parameters to determine combustion instability as well as flame transfer functions.

Control Law Design for a Tilt-Duct Unmanned Aerial Vehicle using Sigma-Pi Neural Networks (Sigma-Pi 신경망을 이용한 틸트덕트 무인기의 제어기 설계연구)

  • Kang, Youngshin;Park, Bumjin;Cho, Am;Yoo, Changsun
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.1
    • /
    • pp.14-21
    • /
    • 2017
  • A Linear parameterized Sigma-Pi neural network (SPNN) is applied to a tilt-duct unmanned aerial vehicle (UAV) which has a very large longitudinal stability ($C_{L{\alpha}}$). It is uncontrollable by a proportional, integral, derivative (PID) controller due to heavy stability. It is shown that the combined inner loop and outer loop of SPNN controllers could overcome the sluggish longitudinal dynamics using a method of dynamic inversion and pseudo-control to compensate for reference model error. The simulation results of the way point guidance are presented to evaluate the performance of SPNN in comparison to a PID controller.

Condensation Heat Transfer Characteristics of HCFC - 123 inside Horizontal Smooth Tube (HCFC-123의 수평 평활관내 응축 전열 특성에 관한 연구)

  • 권옥배;오후규;오종택;김성규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.3
    • /
    • pp.24-32
    • /
    • 1993
  • Experimental data on the heat transfer characteristics of HCFC-123 and CFC-11 during condensation in horizontal smooth tube are presented. The experimental apparatus consisted of a closed working fluid loop, coolant loop, and measuring system. The major components of the working fluid loop made of a refrigerant pump, boiler, superheater, refrigerant flow meter, receiver and test section. The tube-in-tube type test section was made of smooth tube which were constructed form 9.52 mm outer diameter of smooth copper tube with 50 mm outside diameter of PVC tube duct. The ranges of parameter, such as refrigerant mass velocity, coolant flow rate, and quality were 90-325kg/($m^2$.s), 60-360kg/h, 5-95% respectively. Data were obtained under steady state condition for annular flow. As a result of these, the condensation heat transfer coefficients for HCFC-123 were slightly lower than those of CFC-11 from 8% to 15% inside horizontal smooth tube. Furthermore, a new generalized correlation for the heat transfer coefficients of HCFC-123 and CFC-11 during condensation inside horizontal smooth tube is proposed.

  • PDF

A Filtered-X LMS Algorithm by New Error Path Identification Method for Adaptive Active Noise Control (적응 능동소음제어를 위한 오차경로 인식 방법을 통한 filtered-X LMS 알고리듬)

  • 권기룡;송규익;김덕규;이건일
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.8
    • /
    • pp.1528-1535
    • /
    • 1994
  • In this paper, a filtered-X LMS algorithm by new error path identification method is proposed for active noise control system. The proposed algorithm identifies accurately the error path transfer function using three microphones and the control of error signal through double loop scheme with on-line. In the computer simulation using the sinusoidal and the practical duct noise, the proposed algorithm reduces noise level about 29.1dB and 10.4dB, respectively. We can observe the improvement of about 0.5dB and 2.5dB in noise level compared with that obtained using the filtered-X LMS algorithm of Eriksson model.

  • PDF

Honeycomb and Laminated Mesh as Open Volumetric Solar Receiver : Performance of Heat Transfer and Pressure Drop (고온 태양열 공기식 흡수기의 충진재 변화에 따른 열전달 및 압력강하 성능 분석)

  • Cho, Ja-Hyun;Lee, Ju-Han;Kang, Kyung-Mun;Seo, Tae-Beom
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.11
    • /
    • pp.760-766
    • /
    • 2008
  • The characteristics of heat transfer and pressure drop of several different porous materials which can be used as inserts inside solar volumetric air receivers were experimentally investigated. Generally, porous materials were inserted into solar volumetric air receivers to increase the thermal performance. In the present work, honeycomb (diameter: 100 mm, thickness: 30 mm), laminated mesh (diameter: 100 mm, thickness: 1 mm) are considered as the inserts for the experiment. The experimental apparatus consists mainly of a cylindrical ceramic duct as a receiver and an electric heater as an energy source. This system is an intake open loop, which used as air of working fluid. The temperatures inside the ceramic tube are measured by thermocouples, which are installed at each layer of the porous materials. The pressure-drop experimental apparatus is fabricated alike the above experimental equipment. An acrylic tube is used like as the ceramic tube, which has the same specifications of the ceramic tube. The pressure drop of porous materials inserted in the acrylic tube is measured between front and rear of those by transmitter. The results show that the laminated mesh surpasses the honeycomb of heat transfer and pressure drop increase as the porous material thickness and Reynolds number.

A Study on Quality and Economical Analysis of B-WLL and Optical Transmission Systems for Substituting M/W Relay System (M/W 중계장치 대체를 위한 B-WLL 및 광전송 장치의 품질과 경제성 분석에 대한 연구)

  • Suh Kyoung-Whoan;Choi Yong-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.9
    • /
    • pp.809-819
    • /
    • 2004
  • In this paper, in order to exclude the expansion of M/W relay frequency or its new frequency assignment possibly, we analyzed a possibility of substituting M/W system by B-WLL or optical fiber network regarding service quality and economical points. To define the target of service quality, pre-condition and analysis method for the selected media have been derived to compare each other. E1 transmission with BER 10$^{-1}$ was chosen as a reference capacity, and service distance was calculated f3r the selected media as a function of availability. Also from the economical point we considered 3 systems such as optical fiber, M/W, and B-WLL based upon basic system structure, and analyzed them for various line configurations of fiber optic and B-WLL according to service period, system capacity, transmission distance, and data rate. It was confirmed that B-WLL can provide quality of service with 99.999 % availability within 1.6 km cell radius, and for optical fiber substitution, the leased fiber conduit on an electric pole is more economical than M/W system irrespective of service period, but in case of directly digging for underground conduit, it turned out ineffective regardless of cabling duct types.