• 제목/요약/키워드: Loop current calculation

검색결과 37건 처리시간 0.028초

상시개방점 양단전압 측정값을 이용한 배전선로 루프운전 가능 여부 판단 방법 (Loop Current Calculation based on Voltage Angle Difference at Tie Switch for Switching Plan Validation in Distribution System Operation)

  • 손주환;임성일
    • 조명전기설비학회논문지
    • /
    • 제29권7호
    • /
    • pp.14-21
    • /
    • 2015
  • Distribution systems are operated in radial structure, but temporal loop structure could be founded the live load transfer. Main purposes of reconfiguration of distribution network are load balancing, loss minimization and voltage drop maintaining. In the loop structure, huge loop current can be flowed between two substations in case of large voltage angle difference. Protection devices of distribution line can be triped by this huge loop current. So, precise calculation of loop current is very important for secure switching. This paper proposes a novel calculation method of loop current using the voltage angle differences measured at the tie switches. Feasibility of the propose method has been verified by various case studies based on Matlab simulation.

배전운영 시스템에서 상시개방 연계 스위치 투입에 의한 루프 운전 중 구간전압 계산 방법 (Section Voltage Calculation while a Loop Operation by Tie-Switch Close in a Distribution Management System)

  • 서정수;임일형;박종호;신용학;최면송
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.397-403
    • /
    • 2016
  • Generally, an electrical distribution configuration is a radial system with one-way current in a distribution management system (DMS). All feeders in a DMS have tie-switches to make radial system. Sometimes, DMS should change a tie-switch for operation. In that case, the tie-switch has to be closed first; then a switch is opened as another tie-switch in order to prevent blackout for customers. At the moment when the tie-switch is closed, distribution system is operated in a loop state, not radial. Before the loop operation, DMS operator has to check any expected events for stable distribution system operation; and the most important event is a mis-operation of a protection relay. In addition, DMS operator should check voltage profile violation but a calculation method of section voltages had not been used. Thus, this paper proposes a calculation method of section voltages at a loop operation in a DMS. The proposed calculation algorithm is verified by Matlap Simulink.

An Inductance Voltage Vector Control Strategy and Stability Study Based on Proportional Resonant Regulators under the Stationary αβ Frame for PWM Converters

  • Sun, Qiang;Wei, Kexin;Gao, Chenghai;Wang, Shasha;Liang, Bin
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1110-1121
    • /
    • 2016
  • The mathematical model of a three phase PWM converter under the stationary αβ reference frame is deduced and constructed based on a Proportional-Resonant (PR) regulator, which can replace trigonometric function calculation, Park transformation, real-time detection of a Phase Locked Loop and feed-forward decoupling with the proposed accurate calculation of the inductance voltage vector. To avoid the parallel resonance of the LCL topology, the active damping method of the proportional capacitor-current feedback is employed. As to current vector error elimination, an optimized PR controller of the inner current loop is proposed with the zero-pole matching (ZPM) and cancellation method to configure the regulator. The impacts on system's characteristics and stability margin caused by the PR controller and control parameter variations in the inner-current loop are analyzed, and the correlations among active damping feedback coefficient, sampling and transport delay, and system robustness have been established. An equivalent model of the inner current loop is studied via the pole-zero locus along with the pole placement method and frequency response characteristics. Then, the parameter values of the control system are chosen according to their decisive roles and performance indicators. Finally, simulation and experimental results obtained while adopting the proposed method illustrated its feasibility and effectiveness, and the inner current loop achieved zero static error tracking with a good dynamic response and steady-state performance.

A Strategy for Balanced Power Regulation of Energy Storage Systems in a Distribution System during Closed-Loop Operation

  • Han, Yoon-Tak;Oh, Joon-Seok;Cha, Jae-Hun;An, Jae-Yun;Hyun, Seung-Yoon;Lee, Jong-Kwan;Seo, In-Yong;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2208-2218
    • /
    • 2017
  • To resolve overload in a distribution system, a distribution system operator (DSO) often performs a load transfer using normally open tie points and switches in the distribution line. During this process, the distribution system is momentarily operated in closed-loop operation. A closed-loop current in the distribution system can cause a power failure due to excess breaking current in the circuit breakers and reclosers. Therefore, it is necessary to calculate the closed-loop current exactly. However, if there are a large number of distributed generation (DG) systems in the distribution system, such as energy storage systems (ESS), they might obstruct the closed-loop operation based on bidirectional power flow. For quick and precise operation of a closed-loop system, the ESS has to regulate the power generation while satisfying closed-loop operation in the worst cases. We propose a strategy for balanced power regulation of an ESS. Simulations were carried out using PSCAD/EMTDC, and the results were compared with calculation results.

Crack width control of precast deck loop joints for continuous steel-concrete composite girder bridges

  • Shim, Changsu;Lee, Chidong
    • Advances in concrete construction
    • /
    • 제10권1호
    • /
    • pp.21-34
    • /
    • 2020
  • Precast deck joints have larger crack width than cast-in-place concrete decks. The initial crack typically occurs at the maximum moment but cracks on precast joints are significant and lead to failure of the deck. The present crack equation is applied to cast-in-place decks, and requires correction to calculate the crack width of precast deck joints. This research aims to study the crack width correction equation of precast decks by performing static tests using high strength and normal strength concrete. Based on experimental results, the bending strength of the structural connections of the current precast deck is satisfied. However it is not suitable to calculate and control the crack width of precast loop connections using the current design equation. A crack width calculation equation is proposed for crack control of precast deck loop joints. Also included in this paper are recommendations to improve the crack control of loop connections.

Complexity Reduction of an Adaptive Loop Filter Based on Local Homogeneity

  • Li, Xiang;Ahn, Yongjo;Sim, Donggyu
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제6권2호
    • /
    • pp.93-101
    • /
    • 2017
  • This paper proposes an algorithm for adaptive loop filter (ALF) complexity reduction in the decoding process. In the original ALF algorithm, filtering for I frames is performed in the frame unit, and thus, all of the pixels in a frame are filtered if the current frame is an I frame. The proposed algorithm is designed on top of the local gradient calculation. On both the encoder side and the decoder side, homogeneous areas are checked and skipped in the filtering process, and the filter coefficient calculation is only performed in the inhomogeneous areas. The proposed algorithm is implemented in Joint Exploration Model (JEM) version 3.0 future video coding reference software. The proposed algorithm is applied for frame-level filtering and intra configuration. Compared with the JEM 3.0 anchor, the proposed algorithm has 0.31%, 0.76% and 0.73% bit rate loss for luma (Y) and chroma (U and V), respectively, with about an 8% decrease in decoding time.

3상 UPS용 인버터의 강인한 비간섭 디지털제어 (Robust Decoupling Digital Control of Three-Phase Inverter for UPS)

  • 박지호;허태원;신동렬;노태균;우정인
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권4호
    • /
    • pp.246-255
    • /
    • 2000
  • This paper deals with a novel full digital control method of the three-phase PWM inverter for UPS. The voltage and current of output filter capacitor as state variables are the feedback control input. In addition, a double deadbeat control consisting of a d-q current minor loop and a d-q voltage major loop, both with precise decoupling, have been developed. The switching pulse width modulation based on SVM is adopted so that the capacitor current should be exactly equal to its reference current. In order to compensate the calculation time delay, the predictive control is achieved by the current·voltage observer. The load prediction is used to compensate the load disturbance by disturbance observer with deadbeat response. The experimental results show that the proposed system offers an output voltage with THD less than 2% at a full nonlinear load.

  • PDF

전류제어기 동특성을 고려한 산업용 서보 구동시스템의 속도제어기 설계 (Speed Controller Design Based on Current Controller Dynamics for Industry Servo Applications)

  • 석줄기;이동춘
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.166-169
    • /
    • 2002
  • The purpose of this paper is to develop systematic analysis and automatic tuning rule of PID controller for industry servo applications. Considering the coupling of inner current control loop and speed loop delay, the target plant fit into second-order plus time delay model. Based on PID controller design for high-order plus known/unknown time delay plant model, some formulars are provided for the control gain calculation and system-based theoretical analysis is developed, and it also allows an automatic controller setup to benefit the inexperienced user. In addition, the proposed design rule gives uniformly satisfactory performance and the motor speed stays on a desired response curve with minimal oscillation and settling time. This approach can be applicable in conjunction with the cascaded control loop which is widely used in practice.

  • PDF

브러시리스 DC 전동기의 직접 토오크 제어 (Direct Torque Control of Brushless DC Motor)

  • 강석주;설승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.475-478
    • /
    • 1994
  • In this paper two methods of torque control for brushless DC motor with non-ideal trapezoidal back EMF are presented. One is the method of modulating the reference current so as to give a constant torque since the torque is given by the back EMF and the. phase currents. And the current control loop includes the feedforward control of back EMF and of the neutral voltage between the neutral points of the inverter and of the machine. The other is a direct voltage calculation algorithm for a given reference torque. In the two methods, the time delay due to the calculation is compensated by one sampling current prediction. The simulation results are presented to verify the proposed methods.

  • PDF

차동기질내에서 위형 루우프 안테나의 배열에 관한 연구 (A study on the Array of Circular Loop Antenna in Moving Media)

  • 최병하
    • 대한전자공학회논문지
    • /
    • 제11권6호
    • /
    • pp.33-37
    • /
    • 1974
  • 본 논문에서는 광속에 비하여 대단히 작은 진도의 운동매질내에서 도형 루우프 안테나의 array에 대한 방사 특성 및 전류분포를 고찰하였다. 즉 운동매질내의 무형 루우프 안테나 array 상태에서 전류에 대한 적분방정식을 유도차고 이 적분방정식의 해로서 courier경수형식의 전류를 구하였다. 이 전류와 운동매질내에서의 Dayadic Green 함수로부터 전자계식을 구하고, 이들 식을 2개소자로 이루어진 강형 루우프 안테나 array에 적용하여 수치계산을 한 다음, 이를 정지매질의 경우와 비교검토한 결과 전계패턴이 운동매질내에서 매질속도와 반대방향으로 확대되고, 매질속도와 같은 방향으로는 축소되며 지향성이 편위됨을 볼 수 있었다. 이와 같은 변화의 정도는 매질속도가 클수록, 또 루우프의 반경이 클수록 현저하였다.

  • PDF