• Title/Summary/Keyword: Loop Filter

Search Result 651, Processing Time 0.028 seconds

Moving target detection by using the hierarchical spatiotemporal filters with orientation selectivity (방향성 계층적 시공간 필터에 의한 움직이는 물체의 검출)

  • 최태완;김재창;윤태훈;남기곤
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.9
    • /
    • pp.135-143
    • /
    • 1996
  • In this paper, we popose a neural network that detects edges of moving objects in an image using a neural network of hierarchical spatial filter with orientation selectivity. We modify the temporal difference network by adding a self loop to each neuraon cell to reduce the problems of phantom edge detected by the neural network proposed by kwon yool et al.. The modified neural network alleviates the phantom edges of moving objects, and also can detect edges of miving objects even for the noisy input. By computer simulation with real images, the proposed neural netowrk can extract edges of different orientation efficiently and also can reduce the phantom edges of moving objects.

  • PDF

Pull-in Characteristics of Delay Switching Phase-Locked Loop (Delay Switching PLL의 Pull-in 특성)

  • 장병화;김재균
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.15 no.5
    • /
    • pp.13-18
    • /
    • 1978
  • A delay switching PLL (DSPLL) is proposed for improvement of the frequency acquisition Performance (pull-in range) while keeping a narrow bandwidth LPF. It has, between the phase detector and the LPF, just a simple RC delay circuit, a switch and another phase detector controlling the switching time. For the common second order PLL, the pull-in capability of the DSPLL is analyzed approximately, without considering additive white noise effect, and verified experimentally. It is shown that the delay switching extends the pull-in range significantly, as much as a half of lock-range. At the phase tracking mode, the delay switching does not function, to make the DSPLL be a normal PLL.

  • PDF

Adaptive Control of Uncertain Systems without Knowing Perfect Uncertainty Bounds (불확실한 시스템의적응제어)

  • Hong-Seok Kim;Chong-Ho Choi
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.11
    • /
    • pp.905-912
    • /
    • 1989
  • An adaptive control scheme is presented for uncertain systems whose uncertainties are upper-bounded by a linear combination of unknown constants and known continuous functions. The state of the closed-loop system is proven to be ultimately bounded. The proposed method modifies the method of Corless and Leitmann in the following two respects. First, the linear region of the saturation function in controller is fixed. Second, the intergration from in parameter estimator is replaced by a low pass filter form. These modifications prevent performance degradation and destabilization of the control system more effectively. The norm of the system states can be made sufficiently small by an appropriate choice of design parameters in the control law. The applicability of the proposed scheme is demonstrated in the position control of a simple pendulum via simulation.

Online Compensation of Parameter Variation Effects for Robust Interior PM Synchronous Motor Drives

  • Shrestha, Rajendra L.;Seok, Jul-Ki
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.713-718
    • /
    • 2011
  • This paper presents an online voltage disturbance estimator to achieve precise torque control of IPMSMs over a high speed operating region. The proposed design has a type of state-filter based on a Luenburger-style closed loop stator current vector observer. Utilizing the frequency response plot (FRF) approach, the estimation accuracy and the parameter sensitivities are analyzed. Accurate torque control and improved efficiency are provided with the decoupling of the effect of the parameter variations. The feasibility of the presented idea is verified by laboratory experiments.

Improvement of PLL performance for three-phase unbalanced voltage source using full order state observer (전차원 상태관측기를 이용한 3상 불평형 전원의 PLL 성능 개선)

  • Kim, Hyeong-Su;Choi, Jong-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.305-308
    • /
    • 2007
  • 본 논문에서는 전력품질 향상용 전력전자기기의 제어에 중요한 정보인 전원의 위상각을 검출하는 기존의 방법들에 대해서 먼저 알아보고, 그 중 불평형한 전원단 전압조건에서도 정확한 위상각을 검출할 수 있는 전차원 상태관측기를 이용한 정상분 전압 추출 PLL(Phase Locked Loop) 방법을 제안한다. 제안된 PLL 방법은 기존의 전역 통과 필터(APF, All Pass Filter)를 이용한 정상분 전압추출기 대신 전차원 상태관측기를 사용함으로써 불평형사고 발생 시 과도상태 응답특성을 개선하였다. 기존의 정상분 전압 추출 PLL 방법과 본 논문에서 제안된 PLL 방법의 성능을 비교하기 위해, 전원단 전압에 불평형 사고 발생시 위상각을 검출하는 모의실험과 실험을 하였고, 이를 통해 기존의 전역 통과 필터를 이용한 정상분 전압 추출 PLL 방법보다 제안된 전차원 상태관측기를 이용한 정상분 전압 추출 PLL 방법의 과도상태 응답특성이 개선됨을 입증하였다.

  • PDF

Modulated Finite Control Set - Model Predictive Control for Harmonic Reduction in a Grid-connected Inverter

  • Nguyen, Tien Hai;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.268-269
    • /
    • 2017
  • This paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. Distorted grid condition is undesirable due to negative effects such as power losses and heating problem in electrical equipments. To enhance the power quality of distributed generation systems under such a condition, a modulated finite control set - model predictive control (MFCS-MPC) scheme will be proposed, in which the optimal switching signals of inverter are chosen by online basis using the principle of current error minimization. In addition, the moving average filter (MAF) is used to improve the phase-lock loop in order to obtain the harmonic-free reference currents on the stationary frame. The usefulness of the proposed MFCS-MPC method is proved by the comparative simulation results under different operating conditions.

  • PDF

A study on properties optical transparency effect and Hysteresis of transparent PLZT (투광성 PLZT의 HYSTERESIS와 광투과 효과에 과한 연구)

  • Lee, H.G.;Kim, S.Y.;Song, J.T.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.21-23
    • /
    • 1993
  • In this study PLZT was selected which has the excellent quadratic electro-optic property and slim-loop. It was fabricated by the methods of vacuum hot-pressing and sintering. The electrode of color filter was evaporated using the interdigital type masks. Through XRD have we investigated the molecular structure composition formular. Hysteresis and transmission characteristics were measured, The transmission of RGB was envestigated. We are going to study the correlation of coercive field and the nontransmited field.

  • PDF

Sensorless Control of Three Phase Converter using estimated Input Phase-Voltage and DC-link Voltage (전원전압과 DC-link 전압 추정에 의한 3상 컨버터 센서리스 제어)

  • Chu Hung-Seok;Cheon Chang-Gun;Ahn Jin-Woo;Kim Cheul-U
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.227-230
    • /
    • 2001
  • A new control method of three phase converter without measuring input Phase-voltage and DC-link voltage is Proposed. Input Phase-voltage of these required voltages is estimated using EKF(Extended Kalman Filter) and DC-link voltage is estimated from the measured line currents and the estimated input phase-voltage. This control method is achieved without PLL(Phase Locked Loop) which senses the angle of input phase-voltage and DC-link voltage sensor. In additon, the proposed method controls high power factor and DC-link voltage utilizing the estimated phase angle. This paper describes the effectiveness of the proposed estimated algorithm through simulations.

  • PDF

Design of Wireless Lock-in Amplifier using RF Transmission System (RF 통신을 이용한 무선 Lock-in Amplifier 제작)

  • Park, Hyun-Soo;Lee, Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.131-136
    • /
    • 2008
  • System을 통해 출력되는 신호를 측정할 때 정확한 측정을 방해하는 요소로 잡음이 있다. 이런 신호 측정의 방해 요소인 잡음을 제거 하는 방법 중의 하나로 Lock-in Amp(LIA)가 사용되고 있다. 본 논문에서는 잡음 신호의 제거를 위해 사용 하는 LIA를 제작 하고 특성을 파악 하였으며 RF통신을 이용하여 무선 형태로 제작 하였다. 현재 상용화된 LIA는 프로브를 통한 유선으로 측정신호의 입력을 받게 되지만 본 논문에서 제작된 LIA는 무선신호 형태로 입력 하게 된다. RF통신의 케리어 주파수는 447.9[MHz]로 Digital GMSK 변복조방식을 이용하였다. LIA의 제작은 Dual Phase Sensitive Detecter을 사용하였으며, 주요 구성 요소인 Phase Locked Loop, Phase Shifter, Phase Sensitive Detector, Low Pass Filter등의 구조와 특성을 조사하였다.

  • PDF

Enhanced Dynamic Response of SRF-PLL System in 3 Phase Grid-Connected Inverter (3상 계통연계형 인버터를 위한 SRF-PLL 시스템의 동특성 개선)

  • Choi, Hyeong-Jin;Song, Seung-Ho;Jeong, Seung-Gi;Choi, Ju-Yeop;Choy, Ick
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.71-73
    • /
    • 2008
  • 급변하는 전압 변동 상황에서 전력 제어를 수행하기 위해서 기존의 동기좌표 위상각 검출 제어기의 특성을 보완할 수 있는 방법을 제시하였다. 실질적인 SRF (Synchronous Reference Frame) - PLL(Phase Locked Loop) 시스템에서 계통 전압은 이상적이지 않고 센서 노이즈 등의 저감을 위하여 측정된 전압에 LPF(Low Pass Filter)를 사용하고 있는데 이러한 LPF의 특성을 고려하여 위상각 제어기의 PI게인을 설정하는 방법을 제시하였으며 가변 게인과 LPF 차단주파수 변동방식을 이용하여 전원 전압 사고의 종류에 따라 위상과 전압이 급변하는 경우에 대하여 시뮬레이션과 실험을 통해 제한된 방법으로 동특성이 개선되고 원하는 응답속도로 설계가 가능함을 보였다.

  • PDF