• 제목/요약/키워드: Longitudinal Resolution

검색결과 54건 처리시간 0.022초

Chiari 1.5 Malformation : An Advanced Form of Chiari I Malformation

  • Kim, In-Kyeong;Wang, Kyu-Chang;Kim, In-One;Cho, Byung-Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권4호
    • /
    • pp.375-379
    • /
    • 2010
  • The Chiari 1.5 malformation is defined as a tonsillar hemiation within a Chiari I malformation with additional caudal descent of the brainstem through the foramen magnum. We describe a patient with Chiari I malformation who evolved to Chiari 1.5 malformation during longitudinal follow-up. A 15-year-old girl presented with neck pain during exercise for two years. She had been diagnosed with Chiari I malformation with mild hydrocephalus after minor cervical trauma at the age of six years. At that time, she was asymptomatic. After she complained of aggravated neck pain, neuroimaging (nine years after first imaging) revealed caudal descent of the brainstem and syringomyelia in addition to progression of tonsillar hemiation. Posterior fossa decompressive surgery resulted in complete resolution of neck pain. Based on neuroimaging and operative findings, she was diagnosed as Chiari 1.5 malformation. Neuroimaging performed seven months after surgery showed an increased anterior-posterior diameter of the medulla oblongata and markedly decreased syringomyelia. This case demonstrates progressive developmental process of the Chiari 1.5 malformation as an advanced form of the Chiari I malformation.

Optical Biopsy of Peripheral Nerve Using Confocal Laser Endomicroscopy: A New Tool for Nerve Surgeons?

  • Crowe, Christopher S;Liao, Joseph C;Curtin, Catherine M
    • Archives of Plastic Surgery
    • /
    • 제42권5호
    • /
    • pp.626-629
    • /
    • 2015
  • Peripheral nerve injuries remain a challenge for reconstructive surgeons with many patients obtaining suboptimal results. Understanding the level of injury is imperative for successful repair. Current methods for distinguishing healthy from damaged nerve are time consuming and possess limited efficacy. Confocal laser endomicroscopy (CLE) is an emerging optical biopsy technology that enables dynamic, high resolution, sub-surface imaging of live tissue. Porcine sciatic nerve was either left undamaged or briefly clamped to simulate injury. Diluted fluorescein was applied topically to the nerve. CLE imaging was performed by direct contact of the probe with nerve tissue. Images representative of both damaged and undamaged nerve fibers were collected and compared to routine H&E histology. Optical biopsy of undamaged nerve revealed bands of longitudinal nerve fibers, distinct from surrounding adipose and connective tissue. When damaged, these bands appear truncated and terminate in blebs of opacity. H&E staining revealed similar features in damaged nerve fibers. These results prompt development of a protocol for imaging peripheral nerves intraoperatively. To this end, improving surgeons' ability to understand the level of injury through real-time imaging will allow for faster and more informed operative decisions than the current standard permits.

Aplanat조건과 Achromatwhrjs의 Gauss괄호 표현과 Telephoto형 망언경 대물렌즈의 설계 (Gaussian Bracket Expressions of Aplanatic and Achromatic Conditions for Telephoto Type Telescope Objective Derived from the Numerical Solution)

  • 임천석
    • 한국광학회지
    • /
    • 제4권3호
    • /
    • pp.243-251
    • /
    • 1993
  • 두개의 모듈(module)로서 이루어진 telephoto형 망원경 대물렌즈의 각각의 모듈에 대해 Seidel 1차 수차중 구면수차계수와 코마계수를 영으로 하고, 또 종색수차계수를 영으로 하는 조건을 Gauss괄호를 써서 표현하고, 이어서 이들 연립방정식의 해를 구함으로서 눈으로 직접 관찰하는데 쓰이는 조준용광학계의 최초설계가 유도되었다. 이어서 눈의 분해능에 걸맞게 최적화 수치계산을 수행하여서 최종설계를 얻었다. Aplanat조건을 만족하고 색수차가 제거된 이 telephoto 형 망원경 대물렌즈의 f/${\sharp} 와 half field angle은 각각 8.5, 0.$3^{\circ}$이고 초점거리와 telephoto ratios 는 각각 30cm, 0.839이었다.

  • PDF

CFD simulation of compressible two-phase sloshing flow in a LNG tank

  • Chen, Hamn-Ching
    • Ocean Systems Engineering
    • /
    • 제1권1호
    • /
    • pp.31-57
    • /
    • 2011
  • Impact pressure due to sloshing is of great concern for the ship owners, designers and builders of the LNG carriers regarding the safety of LNG containment system and hull structure. Sloshing of LNG in partially filled tank has been an active area of research with numerous experimental and numerical investigations over the past decade. In order to accurately predict the sloshing impact load, a new numerical method was developed for accurate resolution of violent sloshing flow inside a three-dimensional LNG tank including wave breaking, jet formation, gas entrapping and liquid-gas interaction. The sloshing flow inside a membrane-type LNG tank is simulated numerically using the Finite-Analytic Navier-Stokes (FANS) method. The governing equations for two-phase air and water flows are formulated in curvilinear coordinate system and discretized using the finite-analytic method on a non-staggered grid. Simulations were performed for LNG tank in transverse and longitudinal motions including horizontal, vertical, and rotational motions. The predicted impact pressures were compared with the corresponding experimental data. The validation results clearly illustrate the capability of the present two-phase FANS method for accurate prediction of impact pressure in sloshing LNG tank including violent free surface motion, three-dimensional instability and air trapping effects.

음향광변조기를 이용한 고분해능의 헤테로다인 간섭식 열팽창 측정기술 (High resolution heterodyne interferometric technique with AOM for measuring the thermal expansion)

  • 최병일;이상현;김종철;임동건
    • 한국광학회지
    • /
    • 제13권6호
    • /
    • pp.530-536
    • /
    • 2002
  • 열팽창계수의 정확한 측정은 재료과학이나 공업기술 분야에서 가장 중요한 요구량 중의 하나이다. 음향광변조기(AOM)를 이용한 고분해능 간섭식 열팽창계를 제작하여 성능검사를 하였다. 이 계는 이중광로 헤테로다인 간섭계와 복사열 전기로로 구성되어, 정밀한 변위의 측정과 시료의 신속한 가열 및 냉각이 가능토록 하였다. 또한 레이저의 주파수 안정화를 위하여 2차 맥놀이 주파수를 이용한 3종모드 안정화 He-Ne 레이저를 제작하였으며, 이때의 주파수 안정도는 5$\times$$10^{-9}$이었다. 제작된 계의 길이 측정은 실온에서 1100k온도영역에서 나노미터 정도의 정밀도를 주었다.

Spectroscopic Detection of Alfvénic Waves in Chromospheric Mottles of a Solar Quiet Region

  • Kwak, Hannah;Chae, Jongchul
    • 천문학회보
    • /
    • 제46권2호
    • /
    • pp.78.2-78.2
    • /
    • 2021
  • We present high resolution spectroscopic observations of transverse magnetohydrodynamic (MHD) waves in mottles located near the solar disk center. Different from previous studies that used transversal displacements of the mottles in the imaging data, we investigated the line-of-sight (LOS) velocity oscillations of the mottles in the spectral data. The observations were carried out by using the Fast Imaging Solar Spectrograph of the 1.6 meter Goode Solar Telescope of Big Bear Solar Observatory. Utilizing the spectral data of the Hα and Ca II 8542 Å lines, we measure the LOS velocity of a quiet region including the mottles and rosettes that correspond to the footpoints of the mottles. Our major findings are as follows: (1) Alfvénic waves are pervasive in the mottles. (2) The dominant period of the waves is 2 to 4 minutes. (3) From the time-distance maps of the three-minute filtered LOS velocity constructed along the mottles, it is revealed that the transverse waves in the mottles are closely related to the longitudinal waves in the rosettes. Our findings support the notion that Alfvénic waves can be generated by mode conversion of the slow magnetoacoustic waves as was shown in sunspot regions by Chae et al. (2021).

  • PDF

HD-270 MLC의 소개 및 유용성평가 (Introduction and feasibility study of the HD-270 MLC)

  • 김대영;김원택;이화중;이강혁
    • 대한방사선치료학회지
    • /
    • 제15권1호
    • /
    • pp.1-9
    • /
    • 2003
  • I. 목적 MLC의 단점인 조사영역경계의 요동현상이나, 반음영의 크기를 감소시킬 수 있는 HD270 MLC에 관한 소개와 유용성에 대해 평가하였다. II 대상 및 방법 HD-270 MLC는 PRIMUS(Siemens)의 치료테이블(ZXT) 과 다엽콜리메이터(3D MLC)를 leafs면에 수직방향으로 이동시킴으로써 유효반음영과 조사영역 경계의 요동을 감소시킨다. HD-270 MLC의 효율성과 적당한 resolution을 결정하기 위해 field edge angle(Y축과 이루는 각)이 0도에서 75도까지 15도의 간격으로 된 다각형의 field를 만들고 resolution은 5mm, 3mm, 2mm로 각각의 HD-270 group을 만들어 Siemens사 선형가속기(PRIMUS)의 6MV 광자선을 사용하여 solid phantom에서 SAD 100cm, depth 1.5cm으로 X-Omat film(Kodak)에 60MU로 조사하였다. 조사된 film은 Lumiscan75(LUMISYS)로 스캔해서 RIT113(Radiological Imaging Technology Inc. USA)으로 분석하여 유효반음영과 조사영역 경계의 요동의 변화를 측정하였다. 그리고 치료테이블 움직임의 정확성을 테스트하기 위해 테이블 위에 50Kg의 인체모형팬텀을 놓고 0.001inch의 정밀도를 가진 dial gauge로 가로, 세로, 수직의 세 직각방향으로 ${\pm}5mm,\;{\pm}4mm,\;{\pm}3mm,\;{\pm}2mm$단계별로 측정하였다 III. 결과 Resolution과 field edge angle이 증가할수록 유효반음영과 조사영역 경계의 요동현상은 증가하였다. 그리고 지멘스 ZXT 치료테이블움직임의 오차범위는 ${\pm}1mm$ 이내로 양호하였다. IV. 결론 최근 많이 사용되어지고 있는 다엽콜리메이터의 문제점들을 보완 할 수 있는 HD-270 MLC를 사용함으로써 MLC의 임상적용범위를 보다 넓힐 수 있을 것이다.

  • PDF

서울 거주 산모 모유 중 PBDEs 이성질체 농도 및 노출 요인에 관한 연구 (Concentrations of PBDE Congeners in Breast Milk and Predictors of Exposure in Seoul Residents)

  • 위성욱;윤조희;민병윤
    • 한국환경보건학회지
    • /
    • 제37권6호
    • /
    • pp.440-449
    • /
    • 2011
  • Objectives: This study was designed to determine the levels of polybrominated diphenyl ethers (PBDEs) in breast milk and to evaluate the relations with factors affecting these levels. Methods: The congener levels of PBDE in 22 samples of breast milk were analyzed using a high resolution gas chromatograph with a high resolution mass detector. In accordance with our standard operating procedures, the recoveries of internal standards had to range between 68% and 118%. Since the distribution of PBDE concentrations is close to log-normal, the data were logarithmically transformed before analysis. Test subjects were healthy primipara and multipara mothers with a mean age of 32 (SD = 2.7) in 2006. Results: Seven PBDE congeners (BDE-28, 47, 99, 100, 153, 154, and 183) were detected and identified in all of the pooled breast milk samples, indicating widespread contamination from PBDEs in the environment in Korea. Residue levels of total PBDEs (sum PBDEs from tri- to hepta-BDE) ranged from 0.84-13.1 ng/g lipid with median and geometric mean levels of 2.6 ng/g lipid and 2.74 ng/g lipid, respectively. PBDE congeners 47, 99 and 153 markedly predominated and accounted for about 75% of the amount of the PBDE congeners analyzed. BDE-47 was the dominant congener in most samples, whereas BDE-153 was predominant in a few (n = 7/22). BDE-47 was highly correlated with total PBDEs (r = 0.987, p < 0.01). In analyses of the differences of the means of log transformed breast milk PBDE levels for groups of potential covariates, only breast milk BDE-47 and BDE-99 levels were significantly associated with fish (p < 0.05) and meat consumption (p < 0.01). However, we did not find significant correlations between PBDE levels and maternal age, body mass index (BMI), parity, job presence and smoking status. Conclusions: Our findings are mainly limited due to the small sampling size and low doses of PBDEs exposure. Background and human exposure data of PBDEs is lacking, and longitudinal investigations into the environment and biota are encouraged to determine the health impact on future populations in Korea.

IR-UWB를 이용한 빔 스캐닝 배열 안테나 설계 및 연구 (A Study and Design of Beam Scanning Array Antenna using IR-UWB)

  • 김근용;강은균;김진우;나극환
    • 전자공학회논문지
    • /
    • 제51권3호
    • /
    • pp.194-201
    • /
    • 2014
  • 본 논문에서는 TRM(Transmitter-Receiver Module)을 사용하여 각 안테나에 펄스의 위상을 조정함으로써 빔 패턴 각도를 조정하여 다중 경로 환경에서의 성능저하를 향상시킬 수 있다. 다중 경로 환경에서 성능저하를 향상시키는 임펄스 신호를 왜곡 없이 송 수신하는 빔 스캐닝 시스템(Beam Scanning System)을 설계 및 제작 하였다. 빔 스캐닝 시스템은 안테나 종단 부분에서 신호가 왜곡 없이 송 수신이 가능하여 하며 타 시스템에 영향을 미치지 않아야 한다. 또한 빔 조향을 통하여 표적에 대한 감지 능력도 있어야 한다. 설계한 빔 스캐닝 안테나의 분산특성은 충실도(Fidelity)를 사용하여 분석을 하고 조향과 레이더 해상도(Radar Resolution) 성능은 $1cm{\times}1cm$ 표적의 크기를 사용하여 그 성능을 확인한다. 빔 스캐닝 배열 안테나를 제작하기 위해 IR-UWB(Impulse Radio)용 비발디 안테나(Vivaldi Antenna), 삼중대역 윌킨슨 전력 분배기(Tri-Band Wilkinson power divider), TRM(Transmitter-Receiver Module), 송 수신 모듈(TRM)을 컨트롤 할 수 있는 컨트롤 보드 및 GUI 설계를 하였다. 본 연구를 통해 개발된 UWB 빔 스캐닝 시스템은 빔 패턴 각도를 조정하여 다중 경로 환경에서의 성능저하를 향상시킬 수 있으며, 네트워크 분석기를 이용한 시간영역 분석기술은 안테나 설계 시 안테나의 특성을 정확히 분석을 할 수 있고 손쉽게 빔 폭을 확인 할 수가 있다. 설계한 빔 스캐닝 시스템은 레이더 응용 분야인 지표투과 레이더, 벽 투과 레이더, 의료영상 레이더, 탐색 및 구조 레이더, 비파괴 탐상 레이더 및 무선통신 시스템에 사용 적용이 가능하다.

도로터널에서 MMS를 이용한 정밀안전진단 적용 사례 (An application of MMS in precise inspection for safety and diagnosis of road tunnel)

  • 추진호;박세준;김동석;노은철
    • 한국터널지하공간학회 논문집
    • /
    • 제26권2호
    • /
    • pp.113-128
    • /
    • 2024
  • 향상된 MMS (Mobile Mapping System)를 이용하여 도로터널 정밀안전진단 항목을 검토하고 분석하였다. MMS에 의한 적용 가능한 항목은 외관조사, 조사 및 비파괴시험, 구조안전성, 유지관리방안일 것이다. MMS의 차량속도가 너무 빠르면 점군데이터의 해상도가 낮아지고 너무 느리면 보정값 오차가 증가하는 경향을 보인다. 본 연구에 적용된 장비에서는 50 km/h 속도에서 측정이 효과적이다. MMS의 점군 자료에 근거한 균열폭을 판단하기에는 한계가 있으나 터널내 설비 현황과 방재관리기준과 부합되는지를 검토할 수있다. MMS의 3차원 점군은 횡단면 측량의 검토 및 종단면 측량의 변화에 적용될 수 있는데 이는 터널 전체에 대해 차량 한계를 직관적으로 검토할 수 있을 것이다. 시험 개수와 조사 위치를 무작위로 선정하는 현재 정밀안전진단의 측정과 비교하여 MMS의 연속된 환경조건 측정은 정밀도 높은 분석에서 효과적이며 의미가 있을 것이다.