• Title/Summary/Keyword: Longitudinal Resolution

Search Result 54, Processing Time 0.024 seconds

A Study on the Measurement Methodology for Soft Tissue Deformation Using Laser Extensometer (레이저 변위계를 이용한 생체 연조직의 변형 측정법에 관한 연구)

  • 최경주;홍정화;문무성;이진희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1085-1087
    • /
    • 2002
  • Deformation of soft tissue is known inhomogeneous and non-linear in general. In this study, we propose a measurement methodology of local/global strain during soft tissue elongation precisely using laser extensometer which has high accuracy, resolution and is possible to measure global/local strain. The mechanical tensile test are performed on tibialis cranialis, flexor hallucis longus, extensor digitorum longus of swine hindlimb. In order to measure target displacement, reflective marker is attached to detect elongation on specimen using surgical adhesive. The result of this study is to show that laser extensometer is valid to measure longitudinal elongation which is inhomogeneous and non-linear fur soft tissue.

  • PDF

Reflection-type Optical Waveguide Index Profiling Technique

  • Youk YoungChun;Kim Dug Young
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.49-53
    • /
    • 2005
  • We report a new configuration of a reflection-type confocal scanning optical microscope system for measuring the refractive index profile of an optical waveguide. Several improvements on the earlier design are proposed; a light emitting diode (LED) at 650 nm wavelength instead of a laser diode (LD) or He-Ne laser is used as a light source for better index precision, and a simple longitudinal linear scanning and curve fitting techniques are adapted instead of a servo control for maintaining an optical confocal arrangement. We have obtained spatial resolution of 700 nm and an index precision of $2\times10^{-4}$. To verify the system's capability, the refractive index profiles of a conventional multimode fiber and a home-made four-mode fiber were examined with our proposed measurement method.

Analysis of Flux Distribution in 2 Phase 8 Pole HB type LPM by 3D FEM (3차원 유한요소법에 의한 2상 8극 HB형 LPM의 가동자의 자속분포 해석)

  • Lee, Dong-Ju;Lee, Eun-Woong;Kim, Sung-Hun;Kim, Sung-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.34-36
    • /
    • 1999
  • 2 phase 8 pole HB type LPM(linear pulse motor) has the suitable structure for it's microstep drive. Hence, if this LPM will be drived by this method, the limited(mechanically) step resolution can be increased further and vibration and noise can be decreased considerably. But, It is difficult that this LPM was analyzed in detail because of it's complex magnetic circuits to be composed the LF(longitudinal flux) and TF(transverse flux.) path. If LPM was analyzed by the approximate 2D model, we could not be obtained satisfactory result. Therefore, It is necessary to be analyzed the 3D model in detail for the more satisfactory results. In this paper, we obtain 3D flux distribution of the mover using by 3D FEM(finite element method)

  • PDF

Intravital Laser-scanning Two-photon and Confocal Microscopy for Biomedical Research

  • Moon, Jieun;Kim, Pilhan
    • Medical Lasers
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2021
  • Intravital microscopy is a high-resolution imaging technique based on laser-scanning two-photon and confocal microscopy, which allows dynamic 3D cellular-level imaging of various biological processes in a living animal in vivo. This unique capability allows biomedical researchers to directly verify a hypothesis in a natural in vivo microenvironment at the cellular level in a physiological setting. During the last decade, intravital microscopy has become an indispensable technique in several fields of biomedical sciences such as molecular and cell biology, immunology, neuroscience, developmental, and tumor biology. The most distinct advantage of intravital microscopy is its capability to provide a longitudinal view of disease progression at the cellular-level with repeated intravital imaging of a single animal over time by saving the images after each session.

Residual Stress Measurement on T-type Welded Specimen by Neutron Diffraction

  • Jang, D.Y.;Park, M.J.;Choi, H.D.;Kim, J.P.
    • International Journal of Korean Welding Society
    • /
    • v.1 no.2
    • /
    • pp.45-50
    • /
    • 2001
  • This paper presents application of neutron diffraction technique to the measurement of residual stresses in the T-type 20 m thick welded stainless steel plates(100$\times$50 $mm^2$ and 50$\times$50 $mm^2$). The High Resolution Powder Diffractormeter of the Korea Atomic Research Institute was utilized in the measurement. The power of nuclear reactor was 24 MWt and the measured reflection in the 220 plane (2$\theta$)was $92.66^{\circ}$. Poisson ratio of 0.265 and elastic constant of 211 GPa were applied to the calculation of stresses and strains. Three directional components such as normal, transverse, and longitudinal stresses were measured. The results showed that three components were tensile and became compressive along the y axis in the zone away from the welded center. The compressive stresses became tensile in the zone away from the center line of x axis. This may be due to the balance effect caused by the net stress to keep the specimen shape flat.

  • PDF

Comparison of high-resolution and standard zoom imaging modes in cone beam computed tomography for detection of longitudinal root fracture: An in vitro study

  • Taramsari, Mehran;Kajan, Zahra Dalili;Bashirzadeh, Parinaz;Salamat, Fatemeh
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.171-177
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the efficacy of two imaging modes in a cone beam computed tomography (CBCT) system in detecting root fracture in endodontically-treated teeth with fiber posts or screw posts by selecting two fields of view. Materials and Methods: In this study, 78 endodontically-treated single canal premolars were included. A post space was created in all of them. Then the teeth were randomly set in one of 6 artificial dental arches. In 39 of the 78 teeth set in the 6 dental arches, a root fracture was intentionally created. Next, a fiber post and a screw post were cemented into 26 teeth having equal the root fractures. High resolution (HiRes) and standard zoom images were provided by a CBCT device. Upon considering the reconstructed images, two observers in agreement with each other confirmed the presence or absence of root fracture. A McNemar test was used for comparing the results of the two modes. Results: The frequency of making a correct diagnosis using the HiRes zoom imaging mode was 71.8% and in standard zoom was 59%. The overall sensitivity and specificity in diagnosing root fracture in the HiRes mode were 71.79% and 46.15% and in the standard zoom modes were 58.97% and 33.33%, respectively. Conclusion: There were no significant differences between the diagnostic values of the two imaging modes used in the diagnosis of root fracture or in the presence of root canal restorations. In both modes, the most true-positive results were reported in the post space group.

Reconstruction Method of Spatially Filtered 3D images in Integral Imaging based on Parallel Lens Array (병렬렌즈배열 기반의 집적영상에서 공간필터링된 3차원 영상 복원)

  • Jang, Jae-Young;Cho, Myungjin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.3
    • /
    • pp.659-666
    • /
    • 2015
  • In this paper, we propose a novel reconstruction method of spatially filtered 3D images in integral imaging based on parallel lens array. The parallel lens array is composed of two lens arrays, which are positioned side by side through longitudinal direction. Conventional spatial filtering method by using convolution property between periodic functions has drawback that is the limitation of the position of target object. this caused the result that the target object should be located on the low depth resolution region. The available spatial filtering region of the spatial filtering method is depending on the focal length and the number of elemental lens in the integral imaging pickup system. In this regard, we propose the parallel lens array system to enhance the available spatial filtering region and depth resolution. The experiment result indicate that the proposed method outperforms the conventional method.

Accelerated Resting-State Functional Magnetic Resonance Imaging Using Multiband Echo-Planar Imaging with Controlled Aliasing

  • Seo, Hyung Suk;Jang, Kyung Eun;Wang, Dingxin;Kim, In Seong;Chang, Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.4
    • /
    • pp.223-232
    • /
    • 2017
  • Purpose: To report the use of multiband accelerated echo-planar imaging (EPI) for resting-state functional MRI (rs-fMRI) to achieve rapid high temporal resolution at 3T compared to conventional EPI. Materials and Methods: rs-fMRI data were acquired from 20 healthy right-handed volunteers by using three methods: conventional single-band gradient-echo EPI acquisition (Data 1), multiband gradient-echo EPI acquisition with 240 volumes (Data 2) and 480 volumes (Data 3). Temporal signal-to-noise ratio (tSNR) maps were obtained by dividing the mean of the time course of each voxel by its temporal standard deviation. The resting-state sensorimotor network (SMN) and default mode network (DMN) were estimated using independent component analysis (ICA) and a seed-based method. One-way analysis of variance (ANOVA) was performed between the tSNR map, SMN, and DMN from the three data sets for between-group analysis. P < 0.05 with a family-wise error (FWE) correction for multiple comparisons was considered statistically significant. Results: One-way ANOVA and post-hoc two-sample t-tests showed that the tSNR was higher in Data 1 than Data 2 and 3 in white matter structures such as the striatum and medial and superior longitudinal fasciculus. One-way ANOVA revealed no differences in SMN or DMN across the three data sets. Conclusion: Within the adapted metrics estimated under specific imaging conditions employed in this study, multiband accelerated EPI, which substantially reduced scan times, provides the same quality image of functional connectivity as rs-fMRI by using conventional EPI at 3T. Under employed imaging conditions, this technique shows strong potential for clinical acceptance and translation of rs-fMRI protocols with potential advantages in spatial and/or temporal resolution. However, further study is warranted to evaluate whether the current findings can be generalized in diverse settings.

Vortex behavior in the inertial flow of viscoelastic fluids past a confined cylinder

  • Kim, Ju Min;Kim, Chongyoup;Chung, Changkwon;Ahn, Kyung Hyun;Lee, Seung Jong
    • Korea-Australia Rheology Journal
    • /
    • v.16 no.3
    • /
    • pp.117-128
    • /
    • 2004
  • The effect of molecular parameters on the steady vortex behaviors in the inertial viscoelastic flow past a cylinder has been investigated. FENE-CR model was considered as a constitutive equation. A recently developed iterative solution method (Kim et al., (in press)) was found to be successfully applicable to the computation of inertial viscoelastic flows. The high-resolution computations were carried out to understand the detailed flow behaviors based on the efficient iterative solution method armed with ILU(0) type pre-conditioner and BiCGSTAB method. The discrete elastic viscous split stress-G/streamline upwind Petrov Galerkin (DEVSS-G/SUPG) formulation was adopted as a stabilization method. The vortex size decreased as elasticity increases. However, the vortex enhancement was also observed in the case of large extensibility, which means that the vortex behavior is strongly dependent upon the material parameters. The longitudinal gradient of normal stress was found to retard the formation of vortex, whereas the extensional viscosity played a role in the vortex enhancement. The present results are expected to be helpful for understanding the inertial vortex dynamics of viscoelastic fluids in the flow past a confined cylinder.

Surface measurements of the 5 June 2013 damaging thunderstorm wind event near Pep, Texas

  • Gunter, W. Scott;Schroeder, John L.;Weiss, Christopher C.;Bruning, Eric C.
    • Wind and Structures
    • /
    • v.24 no.2
    • /
    • pp.185-204
    • /
    • 2017
  • High-resolution wind measurements at 2.25 m in height were used to investigate the mean and turbulence properties of an extreme thunderstorm wind event in West Texas. These data were combined with single Doppler scans from the Texas Tech University Ka-band mobile Doppler radars systems (TTUKa) to provide meteorological context over the surface measurement stations for portions of the outflow. Several features characteristic of a severe wind event were noted in the radar data, including a bowing portion of the thunderstorm complex and a small circulation on the leading edge. These features were reflected in the surface wind time histories and provided natural separation between various regions of the outflow. These features also contributed to the peak 1-s gust at all measurement stations. The turbulence characteristics of each outflow region were also investigated and compared. Reduced values of running turbulence intensity and elevated values of longitudinal integral scales were noted during the period of peak wind speed. Larger scales of turbulence within the outflow were also suggested via spectral analysis.