• Title/Summary/Keyword: Long-term deterioration

Search Result 328, Processing Time 0.025 seconds

electrical Damage of Metallized Film Capacitors (필름 Capacitor의 전기적Damage에 관한 연구)

  • ;Chathan M. Cooke
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.6
    • /
    • pp.574-581
    • /
    • 1991
  • Damage in film capacitors has been investigated, using FTIR and ESCA, aiming to elucidate the nature of electrode removal and the possibility of base films to be damaged. Also, tests were conducted to investigate the effect of a long-term thermal aging at elevated temperatures. Unsuccessful clearing or grape-clustering processes can induce a long-term degradation which involves the chemical and morphological changes. Major changes are the oxidation and the decrease in surface crystallinity possibly arising from the corona discharge. An immediate deterioration of BOPP film may occur when the air entrapped between the film layers induces an extensive autocatalytic oxidative degradation. This type of immediate damage may result in a premature failure at an early stage of qualification test. As far as the nature of electrode removal is concerned, a permanent removal of electrode materials was observed in the main erosion area.

  • PDF

An Estimation of the Long-Term Properties of Epoxy Used for Reinforcing Surface in Concrete (콘크리트 표면강화 에폭시의 장기특성 평가)

  • 김성욱;김도겸;이장화;김근경;김상조
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.183-186
    • /
    • 1999
  • Up to date, it is difficult to estimate the consistence of properties on the epoxy liner in service time because an estimation of the long term environment-deterioration with aging has not been processed. In the study, the estimation on epoxy liner is carried by the physical test 7 rounds. There are the elongation the and the crack bridging test in the part of physical tests. An elongation test is carried out with epoxy membrane and a crack bridging test is carried out with specimen painted epoxy on concrete. The subjects of test and estimation are a containment quality system and a fibre-glass reinforced system. The materials of these systems are a Robber added Epoxy, a Silica added Epoxy, and a Fiber reinforced Epoxy. Ensuring the test data, properties of epoxy liner was estimated and the change of properties was predicted on epoxy liners.

  • PDF

Prediction of Depth of Concrete Carbonation According to Microenvironmental Conditions (미세 환경조건에 따른 콘크리트 탄산화 깊이 예측)

  • Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.158-159
    • /
    • 2021
  • When the porous concrete is exposed to the external environment, the internal relative humidity changes from time to time due to the inflow and outflow of moisture. This change in moisture is affected by temperature. The temperature and humidity of concrete is dominant in the carbonation rate, the largest cause of deterioration of concrete. In this study, actual weather data were used as boundary conditions. A carbonization model of concrete temperature and humidity and calcium hydroxide was constructed to perform long-term analysis. There is a slight error in the carbonation formula of the Japanese Academy of Architecture applying the Kishtani coefficient, a representative experimental formula related to carbonization, and the analysis result values. However, considering that it behaves very similarly, it is thought that a fairly reliable numerical analysis model has been established. A slight error is believed to be due to the fact that the amount of residual calcium hydroxide in the carbonated site has not yet been clearly identified.

  • PDF

A Study on the Investigation Technique for Deterioration State of Window·Door and Tile of Apartment Houses (공동주택 창호 및 타일의 열화상태 조사기법에 관한 연구)

  • Lee, Jung-Hun;Bae, Kee-Sun;Lee, Seong-Bok;Oh, Sang-Keun;Choi, Soo-Kyung;Seo, Chi-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.27-30
    • /
    • 2011
  • Analysis data of basics which are used for LCC(Life Cycle Cost) analysis of buildings and maintenance plan, are demanded to secure according as replacement cycle of repairs of apartment houses has come. However, investigation techniques and systems for investigating condition of deterioration of apartment houses, have not been made yet in Korea. For this reason, this study was wanted to make investigation techniques and systems, so the process for maintenance of apartment houses was researched and the required quality and deterioration factors of interior/exterior materials were investigated. As a result Check-List for investigating condition of deterioration, was made. if this is used during a nonscheduled, a routine, a regular and a urgency check, the methodical investigation will be achieved. Furthermore, if this is used for maintenance of apartment houses, it will be helped to select the repair cycle and the long-term repair plan.

  • PDF

A Study on the Deterioration Diagnosis of 600V Shielded Twisted Pair Control/Measurement Cable using Resonance Frequency (케이블 공진을 이용한 600V 제어/계측용 꼬임쌍선 차폐 케이블의 열화상태 진단에 대한 연구)

  • Shin, JaeYoung;Kim, KwangHo;Nah, WanSoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1768-1775
    • /
    • 2015
  • Recent major domestic facilities, such as nuclear power plants, many control cables are installed and are degraded by long-term use, but research on deterioration diagnosis is lacking. In the event of a fault in the cable due to deterioration can be developed into a major accident such as the main plant is stopped, so the deterioration diagnostic techniques of high reliability for the cable is required. In this paper, proposes a methodology using a cable resonance that can effectively diagnose the deterioration of the cable. Prior to the test, we developed a setup for stable measuring the characteristics of the cable and it verified the suitable of the measurement set-up in terms of interactivity and reliability, also measured S-parameters applying verified measurement set-up to the cables that deterioration degree is different. Then, we had amplified the difference in resonance frequency between the healthy state and the deteriorated state using connection in a series of measured S-parameters. In a result from the method, we have verified that the more deteriorate the cables is, the more decrease the resonance frequency is. Measured results are justified by inducing the resonance frequency calculation of the cable from the S- parameters represented by the hyperbolic function formula. VNA(Vector Network Analyzer) for S-parameter measurements used in this study is Agilent E5061B and shielded twisted-pair cables was used for deterioration diagnostic test.

Status and Problems of Buildings Neglected for Long Period after Discontinuance of Construction in Jeju (제주도내 공사중단 장기방치 건축물 현황과 문제점)

  • Kim, Doo-Seong;Han, In-Deok;Jang, Myunghoun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.153-154
    • /
    • 2023
  • Neglected buildings for long period can seriously reduce the durability of the building due to rust in rebars and deterioration in concrete quality due to exposure to outside air, and the seriousness of suspended buildings such as safety accidents and social crimes is emerging due to poor management. In this study, various problems such as the occurrence of safety accidents were analyzed through a fact-finding survey of buildings that have not been maintained due to long-term neglect in all areas of Jeju. In order to reuse a building that has been discontinued, the safety of the building structure itself must be checked. After securing safety through durability investigation, construction should be resumed or converted into a normal building through re-purposing, dismantling, remodeling, etc.

  • PDF

Test-bed Development for Long-term Monitoring of Small Bridge Asset Management (소규모 교량 자산관리를 위한 계측 테스트베드 구축)

  • Park, Jae-Woo;Chae, Myung-Jin;Lee, Giu;Cho, Moon-Young
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.6
    • /
    • pp.13-23
    • /
    • 2012
  • While Category 1 and Category 2 bridges are intensively inspected and carefully managed, many small bridges that are not in the Category 1 and 2 are often forgotten until they decay in serious condition. Since many of these small bridges located in the populated city, failure of them would cause huge negative impact on the community. This paper focuses on the small size concrete bridges for timely repair and rehabilitation work for the effective operation and management. Test bed is developed to define the key parameters to forecast the long term performance of the bridges, mostly concrete box bridges. Key parameters suggested in this paper are cumulative fatigue due to repetitive heavy traffic loads and the acid attacks for concrete material deterioration. The cumulative fatigue is measured by the use of the mileage concept. For the long term data collection and inspection, stable and easy to use data collection system is installed as a test bed. The contribution of this research work is on the development of the test bed to define the key parameters of bridge deterioration.

Study on the correlation between long-term exposure tests and accelerated corrosion tests by the combined damage of salts (염해 및 복합열화에 의한 부식촉진시험과 장기폭로 시험의 상관성에 관한 연구)

  • Park, Sang Soon;Lee, Min Woo
    • Corrosion Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.214-223
    • /
    • 2014
  • Interest in the durability assessment and structural performance has increased according to an increase of concrete structures in salt damage environment recent years. Reliable way ensuring the most accelerated corrosion test is a method of performing the rebar corrosion monitoring as exposed directly to the marine test site exposure. However, long-term exposure test has a disadvantage because of a long period of time. Therefore, many studies on reinforced concrete in salt damage environments have been developed as alternatives to replace this. However, accelerated corrosion test is appropriate to evaluate the critical chlorine concentration in the short term, but only accelerated test method, is not easy to get correct answer. Accuracy of correlation acceleration test depends on the period of the degree of exposure environments. Therefore, in this study, depending on the concrete mix material, by the test was performed on the basis of the composite degradation of the salt damage, and investigate the difference of corrosion initiation time of the rebar, and indoor corrosion time of the structure, of the marine environment of the actual environments were inuestigated. The correlation coefficient was derived in the experiment. Long-term exposure test was actually conducted in consideration of the exposure conditions submerged zone, splash zone and tidal zone. The accelerated corrosion tests were carried out by immersion conditions, and by the combined deterioration due to the carbonation and accelerated corrosion due to wet and dry condition.

Estimation and Adjustment Model Considering Time Value of Money for Long-Term Maintenance Cost of Apartment House (시간적 가치를 고려한 공동주택 장기수선충당금 산정 및 조정 모델)

  • Koo, Seonkeun;Kim, Jonghyeob;Jun, Inyeong;Kim, Yeongjin;Yoon, Yousang;Hyun, Changtaek
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.3
    • /
    • pp.12-21
    • /
    • 2017
  • From 1960, the government decided to build apartment houses on a large scale in order to resolve the rising housing problems. However, the maintenance issues that have arisen from the deterioration of housing has not received adequate attention. The policy focuses only on the supply of housing. By passing new laws, the durable period during which buildings allowed reconstruction was increased, and long term maintenance plans were treated as important issues. The government was then obligated to establish certain long term maintenance plans and costs by legislating a Housing Act and requiring it be adjusted every three years. However, when planning long-term repair costs, doing so without considering the time value of money would become a problem. In addition, if differences between the planned repair costs and actual costs occur, it becomes necessary to adjust the long-term repair costs but, as of yet, the criteria to adjust such things does not exist. For these reasons, if there is lack of money to execute large-scale repair work, a building is unlikely to respond to deterioration of housing; on the other hand, an unnecessary reserve or pool of money can lead to conflict among residents. Therefore, this paper will propose estimation and adjustment models considering the time value of money for long term maintenance costs of apartment houses.

Characteristics of High Early Strength Concrete using Regulated Set Cement (초속경시멘트를 사용한 보수용 조기강도 콘크리트의 특성)

  • Won, Jong-Pil;Kim, Hyun-Ho
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.193-197
    • /
    • 2001
  • The growth in concrete structures repair has prompted major efforts to develop high early strength concrete. The internal or external restraint of thermal shrinkage movements could thus generate tensile stresses in concrete structures if it is used rapid setting repair concrete. Restrained shrinkage and thermal stresses could produce microcracks in concrete which increase its permeability and accelerate its long-term deterioration under weathering and load effects. This study aims at evaluation and increase of the engineering properties of high early strength concrete using regulated set cement.

  • PDF