• Title/Summary/Keyword: Long-rod

Search Result 203, Processing Time 0.029 seconds

Design of Dual Power Controller for Power Control System in Nuclear Power Plant (원자로 출력 제어계통 개발용 이중화 전력 제어기 설계)

  • Kim, Choon-Kyung;Lee, Jong-Moo;Park, Min-Kook;Kwon, Soon-Man
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.269-272
    • /
    • 2006
  • In this paper we describe the design of a Dual Power Controller(DPC) for Power Control System(PCS) in Nuclear Power Plant. The PCS also provides information regarding rod motion, rod position, and status of the Rod Control System. It has Hot/Stand-by type, and also has the function of fault detection for controller itself and power modules. We have implemented the various functions with the dual Power Controller. Due to the developed DPC, we are assured that the commmecial use by this controller be made before long.

  • PDF

Shape Modification for Decreasing the Spring Stiffness of Double-plated Nozzle Type Spacer Grid Spring (이중판 노즐형 지지격자 스프링의 지지 강성감소를 위한 형상 개선)

  • Kang, H.S.;Song, K.N.;Lee, J.H.;Lee, K.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.400-405
    • /
    • 2001
  • Nozzle of the double-plated grid plays the role of the spring to support a fuel rod as well as to provide the coolant path in grid. The nozzle was known to be necessary to reduce the spring stiffness for supporting performance. In this study the contact analysis between the fuel rod and the nozzle type spacer grid was performed by using ABAQUS standard to propose the preferable shape in tenn of spring performance. Two small cuts at the upper and lower part of the nozzle appeared to have a minor effect in decreasing the nozzle stiffness. A long slot at the center of the nozzle was turned out not only to decrease the spring constant as desired but also to increase the elastic displacement.

  • PDF

A Study on the Oil Lubrication Characteristics of Pin Bush for a Connecting Rod (커넥팅로드용 핀부시의 윤활특성 해석에 관한 연구)

  • Kim, Chung-Kyun
    • Tribology and Lubricants
    • /
    • v.25 no.3
    • /
    • pp.157-162
    • /
    • 2009
  • In this paper, the hydrodynamic pressure and minimum oil film thickness of a pin bush bearing for a connecting rod have been analyzed as functions of the number of oil grooves and an arc length of oil grooves. The lubrication characteristic of a pin bush is governed by oil groove design factors, which are considered in this study. The most influential design parameter is a number of oil grooves, which is three oil grooves with an arc length of oil groove, 1/6($60^{\circ}$). This means that oil groove with a long arc length of a pin bush does not contribute to the hydrodynamic pressure development. Thus the optimal design of a pin bush is necessary with an increased number of oil grooves and a reduced arc length.

Development of Power Controller for Control Rod Drive Mechanism in Reactor (원자로 제어봉 구동장치 제어시스템용 전력제어기 개발)

  • Kim, Choon-Kyung;Cheon, Jong-Min;Lee, Jong-Moo;Kwon, Soon-Man
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.575-579
    • /
    • 2003
  • In this paper, we describe a Duplex Power Controller for Control Rod Control System(CRCS). A Duplex Power Controller has the various functions for the reliable operations of Control Rod Drive Mechanism(CRDM). Also we have implemented the diverse functions by utilizing the developed Duplex Power Controller. Due to the developed Duplex Power Controller, we are assured that the commercial operation by this system be made before long.

  • PDF

Additional Surgical Method Aimed to Increase Distractive Force during Occipitocervical Stabilization : Technical Note

  • Antar, Veysel;Turk, Okan
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.2
    • /
    • pp.277-281
    • /
    • 2018
  • Objective : Craniovertebral junctional anomalies constitute a technical challenge. Surgical opening of atlantoaxial joint region is a complex procedure especially in patients with nuchal deformity like basilar invagination. This region has actually very complicated anatomical and functional characteristics, including multiple joints providing extension, flexion, and wide rotation. In fact, it is also a bottleneck region where bones, neural structures, and blood vessels are located. Stabilization surgery regarding this region should consider the fact that the area exposes excessive and life-long stress due to complex movements and human posture. Therefore, all options should be considered for surgical stabilization, and they could be interchanged during the surgery, if required. Methods : A 53-year-old male patient applied to outpatients' clinic with complaints of head and neck pain persisting for a long time. Physical examination was normal except increased deep tendon reflexes. The patient was on long-term corticosteroid due to an allergic disease. Magnetic resonance imaging and computed tomography findings indicated basilar invagination and atlantoaxial dislocation.The patient underwent C0-C3-C4 (lateral mass) and additional C0-C2 (translaminar) stabilization surgery. Results : In routine practice, the sites where rods are bound to occipital plates were placed as paramedian. Instead, we inserted lateral mass screw to the sites where occipital screws were inserted on the occipital plate, thereby creating a site where extra rod could be bound.When C2 translaminar screw is inserted, screw caps remain on the median plane, which makes them difficult to bind to contralateral system. These bind directly to occipital plate without any connection from this region to the contralateral system.Advantages of this technique include easy insertion of C2 translaminar screws, presence of increased screw sizes, and exclusion of pullout forces onto the screw from neck movements. Another advantage of the technique is the median placement of the rod; i.e., thick part of the occipital bone is in alignment with axial loading. Conclusion : We believe that this technique, which could be easily performed as adjuvant to classical stabilization surgery with no need for special screw and rod, may improve distraction force in patients with low bone density.

A Research on the Classified Structural System in Long-Span Structures (대공간 구조형식 분류체계에 관한 연구)

  • Yang, Jae-Hyuk
    • Journal of Korean Association for Spatial Structures
    • /
    • v.2 no.3 s.5
    • /
    • pp.81-92
    • /
    • 2002
  • The objective of this paper is to help to make decision of the appropriate structural types in long span structured building due to range of span. For the intention, based on 7 forces of structural element, it is analized the relationships among 6 configurations of structural element(d/1), 25 structural types, 4 materials, and span-length known with 186 sample from 1850 to 1996. 1) bending forces: $club(1/100{\sim}1/10),\;plate(1/100{\sim}1/10),\;rahmen(steel,\;10{\sim}24m)\;simple\;beam(PC,\;10{\sim}35m)$ 2) shearing forces: $shell(1/100{\sim}1/1000)\;hyperbolic\;paraboloids(RC,25{\sim}97m)$ 3) shearing+bending forces: plate, folded $plate(RC21{\sim}59m)$ 4) compression axial forces: club, $arch(RC,\;32{\sim}65m)$ 5) compression+tension forces: shell, braced dome $shell(RC,\;40{\sim}201m),\;vault\;shell(RC,\;16{\sim}103m)$ 6) compression+tension axial forces: $rod(1/1000{\sim}1/100)$, cable(below 1/1000)+rod, coble+rod+membrane(below 1/1000), planar $truss(steel,\;31{\sim}134m),\;arch\;truss(31{\sim}135m),\;horizontal\;spaceframe(29{\sim}10\;8m),\;portal\;frame(39{\sim}55m),\;domical\;space\;truss(44{\sim}222m),\;framed\;\;membrane(45{\sim}110m),\;hybrid\;\;membrane\;(42{\sim}256m)$ 7) tension forces: cable, membrane, $suspension(60{\sim}150m),\;cable\;\;beam(40{\sim}130m),\;tensile\;membrane(42{\sim}136m),\;cable\;-slayed(25{\sim}90m),\;suspension\;membrane(24{\sim}97m),\;single\;layer\;pneumatic\;structure(45{\sim}231m),\;double\;layer\;pneumatic\;structures(30{\sim}44m)$

  • PDF

Experimental Measurement of the Thermal-hydraulic Characteristics of subchannels in $6{\times}6$ rod bundles using LSVF mixing vanes (LSVF 혼합날개를 이용한 $6{\times}6$ 봉다발의 부수로에서의 열수력적 특성에 관한 실험적 측정)

  • Seo, Jeong-Sik;Bae, Kyoung-Keun;Choi, Young-Don
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.188-193
    • /
    • 2006
  • In present study, the thermal-hydraulic characteristics of the subchannels are investigated as measuring single-phase heat transfer coefficients and the cross sectional velocity field using LDV in the downstream of support grid in $6{\times}6$ rod bundles. Support grid with mixing vanes make enhancing heat transfer in rod bundles by generating turbulent flow. But this turbulent flow only is reserved in a short distance. Support grid with LSVF mixing vanes keep the turbulent flow a long distance. The experiments are performed at the nominal Reynolds number 30,000 and 50,000. The heat transfer coefficients are measured using heated and unheated copper sensor. In this study, the comparison of local heat transfer coefficients for LSVF mixing vane and split mixing vane is represented.

  • PDF

A study on the measurement and tendency of heterophoria using Von Graefe test and Maddox rod test (프리즘 분리법과 마독스 로드 검사법을 이용한 사위측정과 경향 연구)

  • Oh, Hyun-Jin;Doo, Ha-Young;Oh, Seung-Jin
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.485-491
    • /
    • 2012
  • To investigate the difference in the value of horizontal heterophoria measured in phoria test of about normal 72 college students, using both Von Graefe test and Maddox rod test. We used two different methods which are Von Graefe test and Maddox rod test on full correction condition at the long distance. Using Von Graefe test of horizontal heterophoria Measurement, We measured 21 patients(29%) for orthophoria, 36 patients(50%) for exophoria and 15 patients(21%) for esophoria at distance. Using Maddox rod test of horizontal heterophoria Measurement, We measured 36 patients(50%) for orthophoria, 26 patients(36%) for exophoria and 10 patients(14%) for esophoria at distance. Each test average were $0.93{\Delta}$ BI for Von Graefe test, $0.96{\Delta}$ BI for Maddox rod test. We could not find the definite difference about the value of horizontal heterophoria aby testing method. Furthermore, heterphoria AC/A ratio was found to vary from 1.0 to 8.8 and its relationship to refractive error could not be determined.

Longitudinal Bonding Strength Performance Evaluation of Larch Lumber (낙엽송 소경각재의 종접합 성능평가)

  • Lee, In-Hwan;Pack, Ju-hyun;Song, Da-bin;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.1
    • /
    • pp.85-92
    • /
    • 2018
  • In order to use glued built up timber beam as a structural member for post and beam construction, it must be possible to manufacture long-span lumber. In this study, the researchers conducted a performance evaluation for longitudinal bonding of lumber (cross-section $89{\times}120mm$) made from larch. The specimens were prepared in six different forms using the longitudinal bonding method. The bonding strength of these specimens was tested through tensile strength tests and bending strength tests. The tensile strength test result of the longitudinally bonded parts was better than that of the double lap specimens. And, the tensile strength value of the scarf specimen was better than that of the hooked scarf specimen. The tensile strength of the GFRP (Glass Fiber Reinforced Plastic) rod insertion bonding specimen was 3.6 MPa, which was the highest. As for the bending strength test result of the longitudinally bonded part, the average MOR (modulus of rupture) of the specimen where a GFRP rod was inserted and bonded measured 29 MPa, while the specimens of other bonded parts showed a MOR no more than 11 MPa. Toughness destruction was observed in specimens where a GFRP rod was insertion-bonded. The rest of the specimens showed brittle destruction. The average MOR strength of the Rod + Lap specimen was 30.5 MPa, which was the highest among all longitudinally bonded specimens. The bending strength of the Rod + Lap specimens showed an effective strength that was 66% of that of the control group which were not longitudinally bonded.

The Diffusion of Boron from Borate Rod through Pinus densiflora and Pinus koraiensis (소나무와 잣나무에서 붕산염 막대로부터 붕소의 확산)

  • Oh, Choong-Sup;Kim, Jae-Jin;Kim, Gyu-Hyeok
    • Journal of Conservation Science
    • /
    • v.7 no.2
    • /
    • pp.60-67
    • /
    • 1998
  • The effects of moisture content (MC) and diffusion period on the diffusion of boron from borate rod through Pinus densiflora and P. koraiensis were investigated as a preliminary research of integrated remedial treatment for heritage wooden structures using borate rod. After equilibrating MCs of samples (15, 25, and 40%), borate rod (1,000 mg) was inserted into the sample, and stored for diffusion of boron at room temperatures ($23^{\circ}C$) for 2, 4, 8, and 12 weeks. Wafers were serially cut at constant intervals from rod treatment point and the boron penetration through longitudinal and transverse direction was measured by staining with boron indicator. For boron diffusion, MC above fiber saturation point was needed, and the diffusion rates increased with time. The fastest rates of diffusion were observed in longitudinal direction, followed by the radial and then the tangential direction. The rates of diffusion in all directions were the fastest in P. koraiensis. In P. densiflora, the diffusion rates through heartwood was faster than that in sapwood in longitudinal direction and vice versa in transverse direction. Based on the best result of this study, optimal space between rod insertion points could be recommended as follows; approximately 120 mm for P. koraiensis and heartwood of P. densiflora, 60 mm for sapwood of P. densiflora in longitudinal direction, and approximately 30 mm for all species tested in transverse direction. However, the effect of rod size and long-term exposure for diffusion on boron movement should be fully investigated for the accurate evaluation of optimal space between rod holes.

  • PDF