• 제목/요약/키워드: Long-range operation

검색결과 279건 처리시간 0.028초

스마트 폰 기반의 마우스와 키보드 제어 어플리케이션 (The Mouse & Keyboard Control Application based on Smart Phone)

  • 임양미
    • 한국멀티미디어학회논문지
    • /
    • 제20권2호
    • /
    • pp.396-403
    • /
    • 2017
  • In recent years, the use of touch screens has expanded, and devices such as remote controllers have been developed in various ways to control and access contents at long range. The wireless-based touch screen is used in classroom, seminar room, and remote video conversation in addition to the TV remote control. The purpose of the study is to design a smart phone-based intuitive interface that can perform the role of a wireless mouse and a wireless keyboard at range using Bluetooth and to develop an application that integrates functions of a mouse and a keyboard. Firstly, touch interaction model for controlling software such as PowerPoint by connecting to a general PC on a smart phone has been studied. The most simple touch operation interface is used to reproduce the function of existing devices and design more simply. The studies of the extension of interfaces with various functions are important, but development of optimized interfaces for users will become more important in the future. In this sense, this study is valuable.

Improvement of lower hybrid current drive systems for high-power and long-pulse operation on EAST

  • M. Wang;L. Liu;L.M. Zhao;M.H. Li ;W.D. Ma;H.C. Hu ;Z.G. Wu;J.Q. Feng ;Y. Yang ;L. Zhu ;M. Chen ;T.A. Zhou;H. Jia;J. Zhang ;L. Cao ;L. Zhang ;R.R. Liang;B.J. Ding ;X.J. Zhang ;J.F. Shan;F.K. Liu ;A. Ekedahl ;M. Goniche ;J. Hillairet;L. Delpech
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.4102-4110
    • /
    • 2022
  • Aiming at high-power and long-pulse operation up to 1000 s, some improvements have been made for both 2.45 GHz and 4.6 GHz lower hybrid (LH) systems during the recent 5 years. At first, the guard limiters of the LH antennas with graphite tiles were upgraded to tungsten, the most promising material for plasma facing components in nuclear fusion devices. These new guard limiters can operate at a peak power density of 12.9 MW/m2. Strong hot spots were usually observed on the old graphite limiters when 4.6 GHz system operated with power >2.0 MW [B. N. Wan et al., Nucl. Fusion 57 (2017) 102019], leading to a reduction of the maximum power capability. With the new limiters, 4.6 GHz LH system, the main current drive (CD) and electron heating tool for EAST, can be operated with power >2.5 MW routinely. Long-pulse operation up to 100 s with 4.6 GHz LH power of 2.4 MW was achieved in 2021 and the maximal temperature on the guard limiters measured by an infrared (IR) camera was about 540 ℃, much below the permissible value of tungsten material (~1200 ℃). A discharge with a duration of 1056 s was achieved and the 4.6 GHz LH energy injected into the plasma was up to 1.05 GJ. Secondly, the fully-active-multijunction (FAM) launcher of 2.45 GHz system was upgraded to a passive-active-multijunction (PAM), for which the density of optimum coupling was relatively low (below the cut-off value). Good coupling with reflection coefficient ~3% has been achieved with plasma-antenna distance up to 11 cm for the new PAM. Finally, in order to eliminate the effect of ion cyclotron range of frequencies (ICRF) wave on 4.6 GHz LH wave coupling, the location of the ICRF launcher was changed to a port that is located 157.5° toroidally from the 4.6 GHz LH system and is not magnetically connected.

잠김 금속판을 이용한 하지의 전이성 병적 골절에 대한 치료 (Metastatic Pathologic Fractures in Lower Extremities Treated with the Locking Plate)

  • 서창영;정성택
    • 대한골관절종양학회지
    • /
    • 제16권2호
    • /
    • pp.80-86
    • /
    • 2010
  • 목적: 골격계는 전이성 암에 의해 흔히 영향을 받는 부위이다. 본 연구를 통해 하지에서 발생한 전이성 병적 골절에 대한 치료로서 잠김 금속판을 이용한 치료 결과에 대해 알아보고자 한다. 대상 및 방법: 2004년부터 2010년까지 하지에 발생한 전이성 암에 의한 병적 골절에 대하여 잠김 금속판을 이용하여 치료받은 12명(13예)의 환자를 대상으로 평가를 시행하였다. 평균 환자 나이는 62.2세(50-81세)였으며, 골절은 각각 근위 대퇴골 2예, 대퇴골 간부 3예, 원위 대퇴골 3예, 근위 경골 4예, 원위 대퇴골 1예에서 발생하였다. 치료 결과로서 휠체어 보행 가능 시기, 통증 완화 정도 및 합병증을 평가하였으며, 또한 수술 시간 및 술 후 실혈량에 대하여 평가하였다. 결과: 수술 후부터 휠체어 보행까지는 평균 3.2일(1-6일)이 소요되었다. 평균 시각 통증 척도는 수술 전 8.1점(7-9점)에서 술 후 1주일째 2.7점(2-4점)으로 호전되었으며, 수술과 연관된 조기 합병증은 발생하지 않았다. 평균 수술 시간은 88.4분(70-105분)이었으며, 술후 평균 실혈량은 246.5 ml (130-320 ml)이었다. 결론: 하지의 전이성 병적 골절에 대한 치료로서, 잠김 금속판을 이용한 내고정술은 심한 골 파괴나 골 결손을 보이는 장골의 골간단부 혹은 골간부 병변에 효과적인 치료 방법이며, 또한 조기 보행을 가능하게 하고, 통증 및 술후 합병증 감소에 도움을 줄 수 있을 것이다.

The Effectiveness of Mapping Biopsy in Patients with Extramammary Paget's Disease

  • Kim, Byung Jun;Park, Shin Ki;Chang, Hak
    • Archives of Plastic Surgery
    • /
    • 제41권6호
    • /
    • pp.753-758
    • /
    • 2014
  • Background Extramammary Paget's disease (EMPD) is an intraepithelial carcinoma usually occurring on the skin or mucosa of the perineum. Clinically, it resembles eczema or dermatitis, and misdiagnosis and treatment delays are common. The treatment of choice for EMPD is a wide excision with adequate margins. Wide excision with intraoperative frozen biopsy and Mohs micrographic surgery are common methods; however, these are associated with a high recurrence rate and long operation time, respectively. Methods Between January 2010 and June 2013, 21 patients diagnosed with EMPD underwent mapping biopsy. Biopsy specimens were collected from at least 10 areas, 2 cm from the tumor margin. When the specimens were positive for malignancy, additional mapping biopsy was performed around the biopsy site of the positive result, and continued until no cancer cells were found. Based on the results, excision margins and reconstruction plans were established preoperatively. Results The patients (18 male, 3 female) had a mean age of 66.5 years (range, 50-82 years). Almost all cases involved in the perineal area, except one case of axillary involvement. Permanent biopsy revealed one case (4.8%) of positive cancer cells on the resection margin, in which additional mapping biopsy and re-operation was performed. At the latest follow-up (mean, 27.4 months; range, 12-53 months), recurrence had not occurred. Conclusions Preoperative mapping biopsy enables accurate resection margins and a preoperative reconstructing plan. Additionally, it reduces the operation time and risk of recurrence. Accordingly, it represents an effective alternative to Mohs micrographic surgery and wide excision with intraoperative frozen biopsy.

The Ross Procedure in Pediatric Patients: A 20-Year Experience of Ross Procedure in a Single Institution

  • Yoon, Dong Woog;Yang, Ji-Hyuk;Jun, Tae-Gook;Park, Pyo Won
    • Journal of Chest Surgery
    • /
    • 제50권4호
    • /
    • pp.235-241
    • /
    • 2017
  • Background: The Ross/Ross-Konno procedure is considered a good option for irreparable aortic valve disease in pediatric patients because of its hemodynamic performance and potential for growth of the pulmonary autograft. This study is a review of the long-term results of our 20-year experience with the Ross and Ross-Konno operations in a single institution. Methods: Between June 1995 and January 2016, 16 consecutive patients (mean age, $6.0{\pm}5.9years$; range, 16 days to 17.4 years) underwent either a Ross operation (n=9) or a Ross-Konno operation (n=7). The study included 12 males and 4 females, with a median follow-up period of 47 months (range, 6 to 256 months). Results: There were no cases of in-hospital or late mortality. Six reoperations were performed in 5 patients. Four patients underwent right ventricular-pulmonary artery (RV-PA) conduit replacement. Two patients underwent concomitant replacement of the pulmonary autograft and RV-PA conduit 10 years and 8 years after the Ross operation, respectively. The rate of freedom from adverse outcomes of the pulmonary autograft was 88% and 70% at 5 and 10 years, respectively. The rate of freedom from valve-related reoperations was 79% and 63% at 5 and 10 years, respectively. Conclusion: Pulmonary autografts demonstrated good durability with low mortality. The Ross/Ross-Konno procedure is a good option that can be performed safely in pediatric patients with aortic valve disease, even in a small-volume center.

흉추 추간판 탈출증에서 흉강경하 흉추간판 절제술 (Thoracoscopic Discectomy of the Herniated Thoracic Discs)

  • 이상호;임상락;이호연;전상협;한영미;정병주
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권12호
    • /
    • pp.1577-1583
    • /
    • 2000
  • Objectives : Among the various types of minimally invasive spine surgeries, thoracoscopic surgery is becoming more widely accepted and increasingly utilized. This report delineates our clinical experience using thoracoscopy to resect herniated thoracic discs in 16 patients who suffered from myelopathy or intolerable radiculopathy. Patients and Methods : Between Mar. 1997 and Sep. 1999, 16 consecutive patients underwent thoracoscopic discectomy for treatment of herniated thoracic discs. There were 12 men and 4 women(mean age 43.5 years ; range 18-61 years). Eleven patients presented with myelopathic signs and symptoms from spinal cord compression and 5 patients had incapacitating thoracic radicular pain without myelopathy. The surgical level was varied between T3 and T12. The pathology of specimen were 11 hard discs and 5 soft discs herniations. Thoracoscopic techniques were performed with long narrow spine instruments and high speed drill through 3 or 4 ports under one lung ventilated general anesthesia. During the operation three patients were converted to open thoracotomy due to intolerable one lung ventilation, excessive bleeding and inadequate operation field. The mean operation time was 264min.(range : 100-420min.), and postoperative mean admission period was 11 days. Results : Clinical and neurological outcomes were good in all patients(mean follow-up period 20 months). Among the eleven myelopathic patients, 8 improved neurologically, and 3 stabilized. Among the five radiculopathic patients, 4 recovered completely and no patient had worsened. Postoperative complications were pleural effusion in one case, intercostal neuralgia in one, delayed hemopneumothorax in one, prolonged air leakage in one and pneumonia in one case. Conclusions : Thoracoscopic discectomy needs a steep learning curve to be familiar to anatomical space and handling of endoscopic instruments. However, it is technically feasible and can be effectively performed with acceptable results.

  • PDF

무지 다지증 III, IV형의 치료에 Bilhaut-Cloquet 방법의 적극적 이용 (Extended Indications of Bilhaut-Cloquet Procedure for Type III and IV of Duplicated Thumb)

  • 임영빈;설정현;남현재;우상현
    • Archives of Plastic Surgery
    • /
    • 제38권6호
    • /
    • pp.821-828
    • /
    • 2011
  • Purpose: The authors applied Bilhaut-Cloquet procedure to Wassel type III and IV duplicated thumb, which was limited to patients with Wassel type I, II. This procedure was applied in order to improve the growth potential, range of joint motion, joint stability and cosmetic outcome. Methods: Sixteen patients received Bilhaut-Cloquet procedures to correct duplicated thumbs from May, 2005 to December, 2010. Seven patients were Wassel type III, nine patients were type IV. This procedure was applied not only to balanced type, but also unbalanced type or convergent type. Five patients were balanced type and eleven patients were unbalanced type. Convergent type of Wassel type IV was three. Sex ratio was the same, mean age at the operation was 20.1 months old (8~52 months old). Angular deformity, joint stability and range of joint motion and cosmetic outcome were considered together and estimated in Tada score. Also, postoperative subjective satisfaction score of the parents was evaluated by a 100-points scale. Results: Mean subjective satisfaction scored 75 points at 28 months after the operation. Radiologic study showed bony union of proximal phalangeal bone and stable joint in all patients. Range of motion was mean 20 degrees in interphalangeal joint and mean 73 degrees in metacarpophalangeal joint. Tada score showed 'good' in eleven patients (68.8%), 'fair' in three patients (18.7%) and 'poor' in two patients (12.5%). In seven patients those who were able to follow up for a long term showed no significant difference in length of proximal and distal phalangeal bones compared to the opposite thumb. Conclusion: Bilhaut-Cloquet procedure can be applied not only to balanced type of Wassel type III, IV duplicated thumb, but also to unbalanced type or convergent type that focused on functional reconstruction and cosmetic improvement.

Compliant Ultrasound Proximity Sensor for the Safe Operation of Human Friendly Robots Integrated with Tactile Sensing Capability

  • Cho, Il-Joo;Lee, Hyung-Kew;Chang, Sun-Il;Yoon, Euisik
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.310-316
    • /
    • 2017
  • The robot proximity and tactile sensors can be categorized into two groups: grip sensors and safety sensors. They have different performance requirements. The safety sensor should have long proximity range and fast response in order to secure enough response time before colliding with ambient objects. As for the tactile sensing function, the safety sensor need to be fast and compliant to mitigate the impact from a collision. In order to meet these requirements, we proposed and demonstrated a compliant integrated safety sensor suitable to human-friendly robots. An ultrasonic proximity sensor and a piezoelectric tactile sensor made of PVDF films have been integrated in a compliant PDMS structure. The implemented sensor demonstrated the maximum proximity range of 35 cm. The directional tolerance for 30 cm detection range was about ${\pm}15^{\circ}$ from the normal axis. The integrated PVDF tactile sensor was able to detect various impacts of up to 20 N in a controlled experimental setup.

해안방어 무기체계 효과분석 방법론: 사례연구를 중심으로 (A Case Study on Analysis Methodology of Costal Defence Weapon System)

  • 신상욱;최봉완;오천균;조한무
    • 한국군사과학기술학회지
    • /
    • 제22권1호
    • /
    • pp.124-134
    • /
    • 2019
  • As the types of North Korea's provocation are diverse and unexpectable in the costal area, ROK navy needs to develop countermeasures, such as costal defence guided rockets. Recently ROK navy developed the PKX-B which is equipped with the new 130 mm guided rocket. The most popular rockets are LOGIR for short range targets, 130 mm guided rocket for middle range targets and Spike-NLOS for long range targets. As various guided rockets are developed, it is required to develop a guided rocket analysis model and it's analysis methodology. In addition, these guided rockets can be installed on any platforms; ground vehicle, aircraft and warship. The paper proposes systematic methodology to estimate the operational effectiveness of costal defence guided rockets. A case study exploiting the ARENA simulation model is explained to demonstrate the implementation of the proposed methodology.

단배부 절개를 이용한 무지 외반증 수술 (Single Dorsal Incision Technic for Hallux Valgus Surgery)

  • 송경원;박인헌;김갑래;이승용;현윤석;서은호
    • 대한족부족관절학회지
    • /
    • 제11권1호
    • /
    • pp.35-38
    • /
    • 2007
  • Purpose: In this study, we introduced a newly developed technique of operation for hallux valgus. We used a single dorsal incision to correct major components of Bunion in stead of two or three incisions, which had been used by most of surgeons for long time. Materials and Methods: Between 2003 and 2005, 27 feet with hallux valgus deformity were operated through single dorsal incision. 10 out of 17 patients underwent operation on both feet, 5 patient underwent operation on left feet, remaining 2 underwent operation on right. There were 16 women and 1 man. Average age of patients was 45 (range, 21-59). Post operatively all feet were evaluated by physical examination, Maryland Foot score profile, radiographic measurements and complication. Results: Maryland foot score profile increased from preoperative 67/100 to postoperative 95/100. Most patients satisfied pain relieve and cosmesis. Average preoperative intermetatarsal angle was 15 degrees, which were decreased to 9 degrees after operation and average preoperative hallux valgus angle was 32 degrees, which were decreased to 12 degrees after operation. Conclusion: According to our experience, the single dorsal incision technic for correction of moderate to severe hallux valgus deformities was rather safe and easily performed without noticeable complication with almost same results as multiple incisions technics. We highly recommend this technic to be tried by foot surgeons without hesitation.

  • PDF