• Title/Summary/Keyword: Long wavelength infrared

Search Result 66, Processing Time 0.026 seconds

Design and Analysis of an Optical System for an Uncooled Thermal-imaging Camera Using a Hybrid Lens (Hybrid 렌즈를 이용한 비냉각 열상장비 광학계 설계 및 분석)

  • Ok, Chang-Min;Kong, Hyun-Bae;Park, Hyun-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.5
    • /
    • pp.241-249
    • /
    • 2017
  • This paper presents the design and evaluation of the optical system for an uncooled thermal-imaging camera. The operating wavelength range of this system is from $7.7{\mu}m$ to $12.8{\mu}m$. Through optimization, we have obtained a LWIR (Long Wave Infrared) optical system with a focal length of 5.44 mm, which consists of four aspheric surfaces and two diffractive surfaces. The f-number of the optical system is F/1.2, and its field of view is $90^{\circ}{\times}67.5^{\circ}$. The hybrid lens was used to balance the higher-order aberrations, and its diffraction properties were evaluated by scalar diffraction theory. We calculated the polychromatic integrated diffraction efficiency, and the MTF drop generated by background noise. We have evaluated the thermal compensation of a LWIR fixed optical system, which is optically passively athermalized to maintain MTF performance in the focal depth. In conclusion, these design results are useful for an uncooled thermal-imaging camera.

Optical Design of a Reflecting Omnidirectional Vision System for Long-wavelength Infrared Light (원적외선용 반사식 전방위 비전 시스템의 광학 설계)

  • Ju, Yun Jae;Jo, Jae Heung;Ryu, Jae Myung
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.2
    • /
    • pp.37-47
    • /
    • 2019
  • A reflecting omnidirectional optical system with four spherical and aspherical mirrors, for use with long-wavelength infrared light (LWIR) for night surveillance, is proposed. It is designed to include a collecting pseudo-Cassegrain reflector and an imaging inverse pseudo-Cassegrain reflector, and the design process and performance analysis is reported in detail. The half-field of view (HFOV) and F-number of this optical system are $40-110^{\circ}$ and 1.56, respectively. To use the LWIR imaging, the size of the image must be similar to that of the microbolometer sensor for LWIR. As a result, the size of the image must be $5.9mm{\times}5.9mm$ if possible. The image size ratio for an HFOV range of $40^{\circ}$ to $110^{\circ}$ after optimizing the design is 48.86%. At a spatial frequency of 20 lp/mm when the HFOV is $110^{\circ}$, the modulation transfer function (MTF) for LWIR is 0.381. Additionally, the cumulative probability of tolerance for the LWIR at a spatial frequency of 20 lp/mm is 99.75%. As a result of athermalization analysis in the temperature range of $-32^{\circ}C$ to $+55^{\circ}C$, we find that the secondary mirror of the inverse pseudo-Cassegrain reflector can function as a compensator, to alleviate MTF degradation with rising temperature.

nBn Based InAs/GaSb Type II Superlattice Detectors with an N-type Barrier Doping for the Long Wave Infrared Detection (InAs/GaSb 제2형 응력 초격자 nBn 장적외선 검출소자 설계, 제작 및 특성평가)

  • Kim, Ha Sul;Lee, Hun;Klein, Brianna;Gautam, Nutan;Plis, Elena A.;Myers, Stephen;Krishna, Sanjay
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.6
    • /
    • pp.327-334
    • /
    • 2013
  • Long-wave infrared detectors using the type-II InAs/GaSb strained superlattice (T2SL) material system with the nBn structure were designed and fabricated. The band gap energy of the T2SL material was calculated as a function of the thickness of the InAs and GaSb layers by the Kronig-Penney model. Growth of the barrier material ($Al_{0.2}Ga_{0.8}Sb$) incorporated Te doping to reduce the dark current. The full width at half maximum (FWHM) of the $1^{st}$ satellite superlattice peak from the X-ray diffraction was around 45 arcsec. The cutoff wavelength of the fabricated device was ${\sim}10.2{\mu}m$ (0.12 eV) at 80 K while under an applied bias of -1.4 V. The measured activation energy of the device was ~0.128 eV. The dark current density was shown to be $1.0{\times}10^{-2}A/cm^2$ at 80 K and with a bias -1.5 V. The responsivity was 0.58 A/W at $7.5{\mu}m$ at 80 K and with a bias of -1.5 V.

Determination of individual sugars in different varieties of persian grape using Near Infrared spectroscopy

  • Kargosha, Kazem;Azad, Jila;Lary, Abas Motamed
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1527-1527
    • /
    • 2001
  • Glucose, fructose and sucrose being the main sugars that can be found in natural fruit juice. Many instrumental methods, such as GC, LC, electrochemical or spectrometric methods provide information about both the total content of sugars and the specific concentration of each carbohydrate[1]. The simplicity of sample handling and measurement in the near IR(NIR) wavelength region, which allows the use of long pathlength, optical glass cells and optical fibers, makes NIR a good alternative for sugar determination [2]. In the present study, six varieties of persian grapes were harvested at intervals through august to october and analysed for sugars by NIR. The results were processed by principal component regression (PCR) and partial least squares (PLS) analysis. Sample juice was prepared by squeezing through gauze from crashed grape. This solution was treated by zinc ferrocyanide prior to analysis in order to eliminate colored compounds and all optically active nonsugar substances. For glucose and fructose the most characteristic wavelengths were 1456nm corresponding to the first harmonic O-H stretching and the second at 2062nm corresponding to O-H stretching and deformation; secondary characteristic combination bands were also seen at 2265 nm (O-H and C-C stretching) and at 2240 nm (C-H and C-C stretching). However these spectra were taken over a wavelength range from 1100-2500nm at room temperature of 25-$30^{\circ}C$. To test the accuracy of the described procedure, samples of six varieties of grape were analysed by the proposed NIR and a standard method[2]. Good agreement were found between these two sets of the results. To perform the recovery studies , samples of grape juices previously analysed by the proposed method, were spiked with known amounts of each individual sugars and then analysed again. Relative standard deviations varied from 1.4 to 1.8% for six independent measurements of individual and total sugar concentration. In the analysis of real and synthetic samples, precise and accurate results were obtained , providing accuracy errors lower than 1.9% in all cases. Average recoveries of ${97}{\pm}{4%}$ for total sugar and between ${95}{\pm}{5%}$ and ${99}{\pm}{2%}$ for sing1e sugars demonstrate the applicability of the methodology developed to the direct analysis of grape Juice.

  • PDF

$1{times}8$ Array of GaAs/AlGaAs quantum well infrared photodetector with 7.8$\mu\textrm{m}$ peak response ($1{times}8$ 배열, 7.8 $\mu\textrm{m}$ 최대반응 GaAs/AlGaAs 양자우물 적외선 검출기)

  • 박은영;최정우;노삼규;최우석;박승한;조태희;홍성철;오병성;이승주
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.6
    • /
    • pp.428-432
    • /
    • 1998
  • We fabricated 1$\times$8 array of GaAs/AlGaAs quantum well infrared photodetectors for the long wavelength infrared detection which is based on the bound-continuum intersubband transition, and characterized its electrical and optical properties. The device was grown on SI-GaAs(100) by the molecular beam epitaxy and consisted of 25 period of 40 ${\AA} $ GaAs well and 500 ${\AA} $ $Al_{0.28} Ga_{0.72}$ As barrier. To reduce the possibility of interface states only the center 20 ${\AA} $ of the well was doped with Si ($N_D=2{\times}10^{18} cm^{-3}$). We etched the sample to make square mesas of 200$\times$200 $\mu\textrm{m}^2$ and made an ohmic contact on each pixel with Au/Ge. Current-voltage characteristics and photoresponse spectrum of each detector reveal that the array was highly uniform and stable. The spectral responsivity and the detectivity $D^*$ were measured to be 180,260 V/W and $4.9{\times}10^9cm\sqrt{Hz}/W$ respectively at the peak wavelength of $\lambda$ =7.8 $\mu\textrm{m}$ and at T=10 K.

  • PDF

A Review of SERS for Biomaterials Analysis Using Metal Nanoparticles (바이오 물질 분석을 위한 금속 나노입자를 이용한 SERS 분석 연구동향)

  • Jang, Eue-Soon
    • Ceramist
    • /
    • v.22 no.3
    • /
    • pp.281-300
    • /
    • 2019
  • Surface enhanced Raman scattering (SERS) was first discovered in 1974 by an unexpected Raman signal increase from Pyridine adsorbed on rough Ag electrode surfaces by the M. Fleishmann group. M. Moskovits group suggested that this phenomenon could be caused by surface plasmon resonance (SPR), which is a collective oscillation of free electrons at the surface of metal nanostructures by an external light source. After about 40 years, the SERS study has attracted great attention as a biomolecule analysis technology, and more than 2500 new papers and 500 review papers related to SERS topic have been published each year in recently. The advantages of biomaterials analysis using SERS are as follows; ① Molecular level analysis is possible based on unique fingerprint information of biomolecule, ② There is no photo-bleaching effect of the Raman reporters, allowing long-term monitoring of biomaterials compared to fluorescence microscopy, ③ SERS peak bandwidth is approximately 10 to 100 times narrower than fluorescence emission from organic phosphor or quantum dot, resulting in higher analysis accuracy, ④ Single excitation wavelength allows analysis of various biomaterials, ⑤ By utilizing near-infrared (NIR) SERS-activated nanostructures and NIR excitation lasers, auto-fluorescence noise in the visible wavelength range can be avoided from in vivo experiment and light damage in living cells can be minimized compared to visible lasers, ⑥ The weak Raman signal of the water molecule makes it easy to analyze biomaterials in aqueous solutions. For this reason, SERS is attracting attention as a next-generation non-invasive medical diagnostic device as well as substance analysis. In this review, the principles of SERS and various biomaterial analysis principles using SERS analysis will be introduced through recent research papers.

Structural and Optical Properties of SnS Thin Films Deposited by RF Magnetron Sputtering (RF 마그네트론 스퍼터링법으로 제조한 SnS 박막의 구조적 및 광학적 특성)

  • Hwang, Donghyun
    • Journal of Surface Science and Engineering
    • /
    • v.51 no.2
    • /
    • pp.126-132
    • /
    • 2018
  • SnS thin films with different substrate temperatures ($150 {\sim}300^{\circ}C$) as process parameters were grown on soda-lime glass substrates by RF magnetron sputtering. The effects of substrate temperature on the structural and optical properties of SnS thin films were investigated by X-ray diffraction (XRD), Raman spectroscopy (Raman), field-emission scanning electron microscopy (FESEM), energy dispersive X-ray spectroscopy (EDS), and Ultraviolet-visible-near infrared spectrophotometer (UV-Vis-NIR). All of the SnS thin films prepared at various substrate temperatures were polycrystalline orthorhombic structures with (111) planes preferentially oriented. The diffraction intensity of the (111) plane and the crystallite size were improved with increasing substrate temperature. The three major peaks (189, 222, $289cm^{-1}$) identified in Raman were exactly the same as the Raman spectra of monocrystalline SnS. From the XRD and Raman results, it was confirmed that all of the SnS thin films were formed into a single SnS phase without impurity phases such as $SnS_2$ and $Sn_2S_3$. In the optical transmittance spectrum, the critical wavelength of the absorption edge shifted to the long wavelength region as the substrate temperature increased. The optical bandgap was 1.67 eV at the substrate temperature of $150^{\circ}C$, 1.57 eV at $200^{\circ}C$, 1.50 eV at $250^{\circ}C$, and 1.44 eV at $300^{\circ}C$.

Design and Fabrication of SiO2/TiO2 Multi Layer Thin Films on Silicon Encapsulation of LED Deposited by E-beam Evaporation for NIR Narrow Band Pass Filter Application (NIR 협대역 투과 필터 응용을 위한 LED 실리콘 봉지재 위에 직접 E-beam으로 증착 된 SiO2/TiO2 다층 박막 설계 및 제작)

  • Kim, Dong Pyo;Kim, Kyung-Seob;Kim, Goo-Cheol;Jeong, Jung-Chae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.2
    • /
    • pp.165-171
    • /
    • 2022
  • The SiO2/TiO2 multilayer thin films used for narrow band pass filter were fabricated using E-beam evaporation method. The narrow band pass filter was used to enhance the resolution of spectroscopy and sensor applications with near infrared (NIR) light source. The narrow band pass filter with multilayer thin films were designed with Essential Macleod program. The multilayers of SiO2/TiO2 with 32 layers were deposited on the silicon encapsulation of IR with peak wavelength (λp) of 660 nm and NIR LEDs with λp of 830 nm, 880 nm, and 955 nm. After NIR light passed through the narrow band pass filter, the full width of half maximum of 33.4~48.6 nm became narrow to 20~24 nm owing to the absorption of photons with short or long wavelength of designed band of 20 nm. The SiO2/TiO2 band pass filter fabricated in this study can be used for sensor, optoelectronics, and NIR spectroscopy applications.

Effect of CuO on the Optical and Structural Properties of Phosphate Glass for Near-Infrard Filter (근적외선 필터용 인산계 유리의 광학적 특성 및 구조적 특성에 미치는 CuO 의 영향)

  • Kim, Seong-Il;Hwang, Jong-Hee;Lim, Tae-Young;Kim, Jin-Ho;Kim, Young-Ho;Lee, Jong-Hwa;Choi, Deuk-Kyun
    • Korean Journal of Materials Research
    • /
    • v.19 no.12
    • /
    • pp.657-660
    • /
    • 2009
  • Optical characteristics and structural changes depending on CuO content in phosphate glasses that are used in near-infrared (near-IR) filters were investigated. With phosphate glasses that contain 1-9 mol% CuO, changes in optical transmittance, optical absorption, and color coordinate were measured with a UV-VIS spectrophotometer. An XPS (X-ray photoelectron spectroscopy) analysis was performed to determine valence of copper ion that influences optical characteristics in near-IR filter glasses. Structural changes in glasses depending on CuO content were also analyzed by FT-IR (Fourier transform infrared) and Raman spectrophotometers. From the UV-VIS spectrophotometer results, strong absorption peaks at 220 & 900 nm were found and transmittance was decreased. The color coordinates of the glasses were shifted to the green color direction with CuO addition for increasing absorption of long wavelength range spectra, in spite of the amount of $Cu^{2+}$, which gives a blue color to glasses, and which was increased in XPS results. Also, structural de-polymerization of glasses with CuO addition were found by FT-IR and Raman results.

High School Student Perception of the Relationships between Solar and Visible Radiation and between Terrestrial and Infrared Radiation (태양 복사와 가시광선 복사 및 지구 복사와 적외선 복사의 관계에 대한 고등학생들의 인식)

  • Lee, Jong-Jin;Seo, Eun-Kyoung;Ahn, Yumin
    • Journal of the Korean earth science society
    • /
    • v.43 no.2
    • /
    • pp.312-323
    • /
    • 2022
  • This study began with the hypothesis of whether "solar radiation" and "terrestrial radiation" can be replaced by "visible radiation" and "infrared radiation", respectively. To this end, we investigated the perceptions of high school students who completed the Earth Science I course through a questionnaire to reveal how they perceived each concept. We also analyzed the descriptions and illustrations of textbooks that may have affected their perceptions. All of the students who participated in the questionnaire recognized solar radiation as radiation emitted only in the visible light region. About 35% of the students recognized convection, conduction, and latent heat as energy transfer by radiation in the Earth's heat budget. By analyzing six types of Earth Science I textbooks in the 2015 revised curriculum, we observed that two types introduced the terms "shortwave radiation" and "longwave radiation" but had no explanation for them, while the other two described solar radiation as "radiation mainly in the visible light region" or "radiation in short wavelengths". Regarding solar and terrestrial radiation in the last two types, there was no explanation for the wavelength regions, or ambiguous terms such as "short wavelength" and "long wavelength" were used. In addition, the two textbooks contained some errors in the illustration of the energy budget. Considering that textbooks described solar and terrestrial radiation without defining the exact terms for shortwave and longwave radiation, learners are likely to recognize solar and terrestrial radiation as visible and infrared radiation, respectively. This finding implies that vague statements or errors in textbooks can cause or reproduce students' misconceptions. The discussion in this study is expected to be used as a helpful reference material for teaching and learning processes regarding the Earth's radiation equilibrium and heat budget, and thereby contribute to proposing reasonable description plans for future textbook writing.