• Title/Summary/Keyword: Long pulse

Search Result 443, Processing Time 0.028 seconds

Harmonically mode-locked semiconductor-fiber ring laser and the output pulse compression (고차 조화 모드록킹된 반도체-광섬유 레이저 구성과 출력 광펄스의 압축)

  • 김동환
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.1
    • /
    • pp.58-63
    • /
    • 1999
  • A 10 GHz harmonically mode-locked semiconductor-fiber ring laser was implemented using a semiconductor optical amplifier at $1.5\mu\textrm{m}$ The laser pulse has 13~18 ps pulse duration, 0.4~0.6 nm spectral width and was positively chirped. The output pulse with an average power of 4 dBm was compressed to 6.8 ps using 2 km long standard single mode optical fiber.

  • PDF

Numerical Analysis of Through Transmission Pulsed Eddy Current Testing and Effects of Pulse Width Variation

  • Shin, Young-Kil;Choi, Dong-Myung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.3
    • /
    • pp.255-261
    • /
    • 2007
  • By using numerical analysis methods, through transmission type pulsed eddy current (PEC) testing is modeled and PEC signal responses due to varying material conductivity, permeability, thickness, lift-off and pulse width are investigated. Results show that the peak amplitude of PEC signal gets reduced and the time to reach the peak amplitude is increased as the material conductivity, permeability, and specimen thickness increase. Also, they indicate that the pulse width needs to be shorter when evaluating the material conductivity and the plate thickness using the peak amplitude, and when the pulse width is long, the peak time is found to be more useful. Other results related to lift-off variation are reported as well.

Analog Adaptive Pulse shaping and Line Equalizer For 400Mb/s data rate on 50m STP Cable

  • Lee, Hoon;Kwisung Yoo;Gunhee Han
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.887-890
    • /
    • 2003
  • High Speed data transmission over a long length of cable is limited due to the limited bandwidth of a cable which introduces ISI(Inter Symbol Interference). In order to compensate for the loss and phase dispersion in the cable, a pulse shaping in a transmitter and a line equalizer in receiver can be used. This paper presents a low-power and small-ana analog adaptive pulse shaping circuit and line equalizer, The design was fabricated in a 0.25${\mu}{\textrm}{m}$ mixed-signal CMOS process. The proposed pulse shaping circuit and equalizer operate at 400Mb/s on 50m STP(Shielded Twisted Pair) cable. It consumes 28.5${\mu}{\textrm}{m}$ with a 2.5-V power supply and occupies only 0.098 $\textrm{mm}^2$.

  • PDF

Gabor Pulse-Based Matching Pursuit Algorithm : Applications in Waveguide Damage Detection (가보 펄스 기반 정합추적 알고리즘 : 웨이브가이드 결함진단에서의 응용)

  • 선경호;홍진철;김윤영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.969-974
    • /
    • 2004
  • Although guided-waves are very efficient for long-range nondestructive damage inspection, it is not easy to extract meaningful pulses of small magnitude out of noisy signals. The ultimate goal of this research is to develop an efficient signal processing technique for the current guided-wave technology. The specific contribution of this investigation towards achieving this goal, a two-stage Gabor pulse-based matching pursuit algorithm is proposed : rough approximations with a set for predetermined parameters characterizing the Gabor pulse and fine adjustments of the parameters by optimization. The parameters estimated from the measured signal are then used to assess not only the location but also the size of a crack existing in a rod. To validate the effectiveness of the proposed method, the longitudinal wave-based damage detection in rods is considered. To estimate the crack size, Love's theory for the dispersion of longitudinal waves is employed.

  • PDF

The 3- dimensional analysis for the discharge of PDP according to the pulse width of voltage applied to the address electrode during sustain period (Sustain 구간중 Address 전극에 인가되는 전압 펄스 폭에 따른 3차원 방전형상 분석)

  • Kwon, Hyoung-Seok;Choi, Hoon-Young;Lee, Seung-Gol;Lee, Seok-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1830-1833
    • /
    • 2002
  • We measured 3-dimensional temporal behavior of the light emitted from AC plasma display panel(PDP) at various auxiliary voltage pulse width supplied to the address electrode in sustain period using scanned point detecting system. In the case of applying an auxiliary address voltage pulse, the light emission starts at the inner edges of the cathode so the larger discharge volume toward address electrode can be obtained compared with the normal sustain discharge. Especially, when the auxiliary voltage pulse width is the $2{\mu}s$, the maximum luminance and long emission time can be obtained.

  • PDF

A study on the reason that pulse-feeling method of meridians diagnosis flows into diagnostic method by taking pulse of setting six region for Chon(寸), Gwan(關) and Cheok(尺), i.e. the Chon[寸] spot pulse -A study on the transition of pulse-feeling method- (경맥진단(經脈診斷)의 맥진법(脈診法)이 기구맥(氣口脈)의 촌관척(寸關尺) 육부정위맥진법(六部定位脈診法)으로 연변(演變)된 연유(緣由)에 관(關)한 연구(硏究) -경맥학설(經脈學說) 및 맥진법(脈診法)의 상관성(相關性)-)

  • Lim, Han-je;Yoon, Jong-hwa
    • Journal of Acupuncture Research
    • /
    • v.21 no.1
    • /
    • pp.1-20
    • /
    • 2004
  • Pulse-feeling took its origin from making a diagnosis along meridians in the course of discovering and forming meridians and for a long time its meaning was mixed with meridians in the course of recognizing "The Pulse" then was separated from meridians in the early days of Western Han Dynasty. Ancient pulse-feeling methods are pulse-feeling method by the twelve regular meridians, pulse-feeling method by three regions and nine modes, pulse-feeling method by Inyeong(人迎) and Chon-gu(寸口), etc. Pulse-feeling was changed in proportion to diagnostic purpose and method of treating and if method and region of pulse-feeling is arranged, we will infer correlation between meridians and pulse-feeling and will infer transitional system of past pulse-feeling and will forecast transition of future pulse-feeling. As the result that I study the transition of the above three pulse-feeling methods of meridians diagnosis: 1. Three pulse-feeling methods of meridians diagnosis flowed into diagnostic method by taking pulse of setting six region for Chon(寸), Gwan(關) and Cheok(尺), i.e. the Chon[寸] spot pulse of $\ll$Nan-gyeong$\gg$ and were changed into diagnostic method being fit for use of five Su points, The Front-Mo points and Back-Su points that grasp the pathology of mutual internal organs and treat the disease. 2. Today it is suggesting the transition of another pulse-feeling method that do not apply diagnostic method by taking pulse of setting six region for Chon(寸), Gwan(關) and Cheok(尺), i.e. the Chon[寸] spot pulse of $\ll$Nan-gyeong$\gg$ to 19C Sasang(四象) Constitutional Medicine or 20C Eight Constitutional Medicine.

  • PDF

Development of 3.6 MW, 4 ${\mu}s$, 200 pps Pulse Modulator for a High power magnetron (고출력 마그네트론 구동용 3.6 MW, 4 ${\mu}s$, 200 pps 펄스모듈레이터 개발)

  • Son, Y.G.;Jang, S.D.;Oh, J.S.;Cho, M.H.;NamKang, W.;Lee, H.K.;Bae, Y.S.;Lee, K.T.;Son, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1778-1780
    • /
    • 2004
  • Microwave heating system of KSTAR consists of ECH and LHCD. ECH and LHCD offer the reliability of operation in the beginning of plasma formation and non-inductive current drive for long time steady state operation with maintaining MHD stability, respectively. LHCD demands 5 GHz of frequency and consists of c-band waveguide, 4-port circuitor, dry dummy load, dual directional coupler, E-bend, arc detector. Our system is a lineup type pulse modulator that has 45 kV of output pulse voltage, 90 A of pulse current, 4 us of pulse width. 1:4 step-up pulse transformer, 7 stages of PFN and thyratron tube (E2V, CX1191D) are used in this modulator. The purpose of this paper is to show the modulator design and experimental result.

  • PDF

A Study on the Performance of Pulse Jet Cleaning in High Temperature Filter (고온 세라믹필터의 펄스젯 탈진 성능에 관한 연구)

  • Kim Byong Ryol;Park Seung Chul;Park Byoung Chul;Cho Hynu Joon;Oh Hyoung Mo;Hwang Tae Won;Shin Sang Woon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.1
    • /
    • pp.9-16
    • /
    • 2005
  • To evaluate parameters influencing on the dust removal of the High Temperature Filter(HTF) system, a computer simulation of fluid dynamics inside the system had been performed. The results showed that the optimum pulse jet periods were 50ms and 90ms for the 1000mm and 1500mm long filter elements respectively. Dust removal effect was very excellent under the pulse jet pressure of 3 bar. But the distance between the pulse jet nozzle and the venturi of a filter element had no meaningful effect on the performance with the variation from 5mm to 10mm. Compared to the dispersion mode of pulse jet, the collective mode of pulse jet flow was preferable in maintaining the pressure inside the system stable.

  • PDF

Pressure Control of a Variable Thrust Solid Propulsion System Using On-Off Controllers (On-Off 제어기를 이용한 가변추력 고체추진 기관의 압력제어)

  • Kwon, Soon-Kyu;Kim, Young-Seok;Ko, Sang-Ho;Suh, Seok-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.942-948
    • /
    • 2011
  • Solid propulsion systems have simple structures compared to other propulsion systems and are suitable for long-term storage. However the systems generally have limits on control of thrust levels. In this paper we introduce controllers for combustion chamber pressure using on-off control techniques which have been known for relatively easy implementation and energy efficiency. For this, we use a simple pressure change model by considering only mass conservation within the combustion chamber and we design a classical controllers and on-off controllers with are Pulse Width Modulation(PWM) and Pulse Width Pulse Frequency Modulation (PWPFM). Then we compare the performance results of the controllers through numerical simulations.

  • PDF

Performance Analysis of the M-PPAM DS-UWB Communication systems (M-PPAM DS-UWB 통신시스템의 성능해석)

  • Cho, Kyung-Ryong;Park, Jang-Woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.8
    • /
    • pp.1656-1662
    • /
    • 2005
  • This paper introduces M-PPAM(M-ary Pulse Position and Amplitude Modulation) architecture, combined PPM(Pulse Position Modulation) with PAM(Pulse Amplitude Modulation). Since M-PPAM can transmit several bits using one pulse, it is mon effective than PPM or PAM. Also, to obtain the same data transmission rate with PPM or PAM, M-PPAM can use a long pulse repetition period. This method will be able to use in the multi-path fading environment such as indoor condition. To accomodate multiple users, direct sequence technique is used. This paper has provided the modeling method of the M-PPAM DS-UWB receiver covering multi-user interference(MUI) with the Standard Gaussian Approximation under Gaussian channel. The performance of the receiver is simulated.