• Title/Summary/Keyword: Long pulse

Search Result 444, Processing Time 0.027 seconds

The Mobile Health-Care Garment System for Measurement of Cardiorespiratory Signal (ECG와 호흡 측정이 가능한 모바일 헬스케어 의류 시스템)

  • Kim, Jeong-Do;Kim, Kap-Jin;Chung, Gi-Su;Lee, Jung-Hwan;Ahn, Jin-Ho;Lee, Sang-Goog
    • The KIPS Transactions:PartA
    • /
    • v.17A no.3
    • /
    • pp.145-152
    • /
    • 2010
  • Most wearable system for mobile healthcare applications consists of three parts. The first part is the sensing elements based on bio-signal, the second is the circuit module for control, data acquisition and wireless communication and control and the third is garment with a built-in electrodes and circuits. The existing healthcare garment systems have to find a solution to signal-wire and uncomfortable and inappropriate electrode to long-term attachment. Even if the wireless communication is used for healthcare garment system, the interface between sensors and circuits have to use wires. To solve these problems, this paper use electrode using PEDOT coated PVDF nanoweb for ECG signal and PVDF film sensor for respiratory signal. And, we constructed garment network using digital yarn of 10um, and transmitted ECG and respiratory signal to mobile phone through the integrated circuit with bluetooth called station To evaluate feasibility of the proposed mobile healthcare garment system, we experimented with transmission and measurement of ECG and respiratory signal using nanoweb electrode and digital yarn. We got a successful result without noise and attenuation.

Pump Light Power of Wideband Optical Phase Conjugator using HNL-DSF in WDM Systems with MSSI (MSSI 기법을 채택한 WDM 시스템에서 HNL-DSF를 이용한 광대역 광 위상 공액기의 펌프 광 전력)

  • Lee Seong real;Cho Sung eun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.3A
    • /
    • pp.168-177
    • /
    • 2005
  • In this paper, we numerically investigated the optimum pump light power resulting best compensation of pulse distortion due to both chromatic dispersion and self phase modulation (SPM) in long-haul 3×40 Gbps wavelength division multiplexing (WDM) systems. We used mid-span spectral inversion (MSSI) method with path-averaged intensity approximation (PAIA) as compensation approach, which have highly nonlinear dispersion shifted fiber (HNL-DSF) as nonlinear medium of optical phase conjugator (OPC) in the mid-way of total transmission line. We confirmed that HNL-DSF is an useful nonlinear medium in OPC for wideband WDM transmission, and in order to achieve the excellent compensation the pump light power is selected to equal the conjugated light power into the latter half fiber section with the input light power of WDM channel depending on total transmission length. Also we confirmed that compensation degree of WDM channel with small conversion efficiency is improved by using pump light power increasing power conversion ratio upper than 1.

A Study of Clinical Research Acupuncture Treatment on Post-stroke Cognitive Disorder (뇌졸중 후 인지장애의 침 치료에 대한 임상적 연구 고찰)

  • Jin, San-long;Yun, Jong-min;Moon, Byung-soon
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.3
    • /
    • pp.389-404
    • /
    • 2018
  • Objective: The aim of this study was to investigate acupuncture therapy for post-stroke cognitive disorder to suggest the methods of a study about acupuncture therapy. Methods: Several academic databases were used in this study, including National Digital Science Library (NDSL), National Assembly Library of Korea, Korean Traditional Knowledge Portal, Research Information Sharing Service (RISS), Korean studies Information Service System (KISS), Korean Medical Database (KMBASE), Korea Med, Oriental Medicine Advanced Searching Integrated System (OASIS), PubMed, MEDLINE with Full Text, and China National Knowledge Infrastructure (CNKI). Keywords used were "중풍", "뇌졸중", "인지장애", "침", "acupuncture", and "cognitive disorder". Results: Ultimately, 28 papers were investigated. that were mainly published in 2012 and 2016. Of these, More than two-thirds received a score of one or less on the Jadad scale. Acupuncture points such as GV20, GV24, PC6, EX-HN1, SP6, and GV26 were most frequently used. The treatment duration was mostly 30 minutes or less, and the treatment cycle was mostly for four weeks. Dilatational wave was generally used in pulse wave form, and amplitude of electricity was increased until patients were able to endure. G6805 was generally used in electric acupuncture apparatus. According to results of acupuncture treatment, assessments such as the MMSE (Mini Mental State Examination) and the Montreal Cognitive Function Assessment Scale (MoCA) showed statistically significant improvements in 28 studies. Conclusions: Future research is needed to standardize the treatment of acupuncture, and more diversified high quality papers should be published to help clarify the therapeutic effects of acupuncture and the mechanisms of cognitive disorder post-stroke.

A Simulation Study of a Chopping System for Extracting a Pulsed Beam from a Cyclotron

  • Kim, Jae-Hong;Hong, Seong-Gwang;Kim, Mi-Jeong;Kim, Seong-Jun;Kim, Myeong-Jin;Kim, Do-Gyun;Yun, Jong-Cheol;Kim, Jong-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.537-537
    • /
    • 2013
  • Cyclotron-accelerated ion beams are used for various researches, such as nuclear physics, nuclear chemistry, biotechnology, and material sciences including radio-isotope production. Recently considerable applications are asked to the cyclotron development undertaken to meet user requirements of various ions'energies, intensities, and their pulsed beams. For instance, a cocktail beam acceleration technique rapidly changing the ion species and energies was developed to irradiating integrated circuit chips. Also a chopping system in a cyclotron injection line is considered for producing a pulsed ion beam with a relatively long period compared with that generated by the resonance frequency. For the research in neutron time-of-flight measurement, a single-pulsed beam with a repetition interval of the order of mili-seconds or longer is necessary to have a good resolution and to remove background events. In this paper a feasibility of pulsed beam with an external ion source is simulated by adopting a combination system of a chopper accompanying with a bunching stage in the injection line and an additional chopper after the exit of the cyclotron in order to produce beam pulses with a range of $1{\mu}s{\sim}1ms$ periods from a resonance RF cycle. The pulseperiod will be adjusted by chopping the number of beam bunches from the injected pulses in the injection line. However, the longer pulses will have reduced number of beam pulses and sacrificed beam currents. Because the beam users need an intense single pulsed beam, a careful tuning of the acceleration phase and a high-intense external ion source are necessary to achieve an intense single-pulsed beam from the cyclotron. It is essential to strictly match the acceleration phase of injected beams in the central region of the cyclotron to improve its efficiency. An effect of space charge at each pulse from the ion source will be also considered.

  • PDF

A Study of High Temperature Filtration Performance Test on Low Density Cylindrical Ceramic Filters (저밀도 원통형 세라믹 필터의 고온 여과 성능시험 연구)

  • 이동섭;홍민선;최종인
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.2
    • /
    • pp.213-222
    • /
    • 2001
  • Cylindrical type ceramic filers, that is 60 O.D$\times$10t$\times$600L and 60 O.D$\times$10t$\times$1,000L were manufactured by vacuum forming processes using ceramic ray materials. For cylindrical type ceramic filters, porosity and bulk density were measured for, 80 to 90% and 0.3 to 0.4 g/㎤, respectively at uniform pore size of 41 to 45${\mu}{\textrm}{m}$. Bench scale candle filters (60$\psi$ $\times$10t$\times$600L) were tested using different dusts collected from many industries including chemical processing, glass processing and metal manufacturing pants. Collection efficiencies found out to range from 99.87% to 99.90%, while resistance coefficients from 1.1$\times$10(sup)11/$m^2$ to 1.7$\times$10(sup)11/$m^2$ . Full scale low density ceramic filters (60$\psi$ $\times$10t$\times$1,000L) were also tested at 1 atm, $600^{\circ}C$ to reveal the filtration efficiency, conditioning, and resistance coefficients using two different types of dust as chemical processing and metal refined processing. Darcys law resistance coefficients were measured to range 1.44$\times$10(sup)11/$m^2$ to 2.74$\times$10(sup)11/$m^2$, and collection efficiencies on the range 99.84 to 99.96%, Finally, results of long term performance test showed that filters were conditioned after 170hrs. Experimental conditions for effective filtration were examined under the condition 10 cm/sec face velocity, 3kg/$\textrm{cm}^2$ pulsing pressure, 5 min filtration cycle, and 300msec pulse opening time.

  • PDF

Ship Positioning Estimation Using Phased Array Antenna in FMCW Radar System for Small-Sized Ships (소형 선박용 FMCW 레이더 시스템에서의 위상 배열 안테나를 사용한 선박의 위치 추정)

  • Lee, Seongwook;Lee, Seong Ro;Kim, Seong-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.6
    • /
    • pp.1130-1141
    • /
    • 2015
  • Conventionally, a pulse radar is used for middle-sized or large-sized ships to detect other ships or obstacles located at a long distance. However, it is hardly equipped for most of the small-sized ships due to mounting and maintenance costs. Therefore, FMCW(frequency modulated continuous wave) radar is suggested as an alternative for the small-sized ships. Since it operates with low power and has good range resolution for relatively close objects, it is eligible for the small-sized ships. In previously proposed FMCW radar system, it only estimates distance and velocity of a target ship placed in the direction of main beam and is hard to detect several ships simultaneously. Thus, we suggest the method for detecting several ships at the same time by applying MUSIC(multiple signal classification) algorithm to FMCW radar signal received by a phased array antenna. In addition, by combining digital beam forming with the MUSIC algorithm, better angle resolution is achievable.

Photoluminescence and Long-phosphorescent Characteristics of SrAl2O4:Eu2+,Dy3+ Phosphor by Glycine-nitrate Combustion Method (글리신-질산염 연소법으로 합성된 SrAl2O4:Eu2+,Dy3+ 형광체의 발광 및 장잔광 특성)

  • Lee, Young-Ki;Kim, Jung-Yeul;Lee, You-Kee
    • Korean Journal of Materials Research
    • /
    • v.20 no.7
    • /
    • pp.364-369
    • /
    • 2010
  • A $SrAl_2O_4:Eu^{2+},Dy^{3+}$ phosphor powder with stuffed tridymite structure was synthesized by glycine-nitrate combustion method. The luminescence, formation process and microstructure of the phosphor powder were investigated by means of X-ray diffraction (XRD), scanning electron microscopy (SEM) and photoluminescence spectroscopy (PL). The XRD patterns show that the as-synthesized $SrAl_2O_4:Eu^{2+},Dy^{3+}$ phosphor was an amorphous phase. However, a crystalline $SrAl_2O_4 $ phase was formed by calcining at $1200^{\circ}C$ for 4h. From the SEM analysis, also, it was found that the as-synthesized $SrAl_2O_4:Eu^{2+},Dy^{3+}$ phosphor was in irregular porous particles of about 50 ${\mu}m$, while the calcined phosphor was aggregated in spherical particles with radius of about 0.5 ${\mu}m$. The emission spectrum of as-synthesized $SrAl_2O_4:Eu^{2+},Dy^{3+}$ phosphor did not appear, due to the amorphous phase. However, the emission spectrum of the calcined phosphor was observed at 520 nm (2.384eV); it showed green emission peaking, in the range of 450~650 nm. The excitation spectrum of the $SrAl_2O_4:Eu^{2+},Dy^{3+}$ phosphor exhibits a maximum peak intensity at 360 nm (3.44eV) in the range of 250~480 nm. After the removal of the pulse Xe-lamp excitation (360 nm), also, the decay time for the emission spectrum was very slow, which shows the excellent longphosphorescent property of the phosphor, although the decay time decreased exponentially.

Effect of Clerodendron trichotomum Thunberg tea on anti-hypertension (누리장나무차가 항고혈압에 미치는 영향)

  • Choo, Han-Na;Lee, Soong-In;Kim, Jeong-Sang;Jeong, Jong-Kil
    • The Korea Journal of Herbology
    • /
    • v.30 no.4
    • /
    • pp.129-135
    • /
    • 2015
  • Objectives : Clerodendron trichotomumThunberg grows wild fields and mountains in South Korea and China. They have been used for anti-hypertension disease. This study was performed in order to observe the effects ofClerodendron trichotomumThunberg tea on anti-hypertension.Methods : For the study ofClerodendron trichotomumThunberg tea, we had divided male SHR (Spontaneously Hypertensive Rat) to ten groups. Control group is SHR. The treatment group is SHR which is administered tea extract at dose of 200 mg/kg/day and 500 mg/kg/day orally for 8 weeks. We measured systolic blood pressure, diastolic blood pressure, number of pulse, body weight, total cholesterol and triglyceride from blood serum.Results : The level of systolic and diastolic blood pressure were significantly decreased by 12.5% and 44.9% inClerodendron trichotomumThunberg tea groups than control group. Heart rate ofClerodendron trichotomumThunberg tea groups, 24.5%, was significantly lower than control group. We found that treatment with the water extract fromClerodendron trichotomumThunberg leave and flower significantly decreased weight of body, total cholesterol and triglyceride to 20.4% and 27.7% compared to untreated control group, significantly (P< 0.05).Conclusions : These results suggest that leaf and flower tea ofClerodendron trichotomumThunberg tea is effective in prevention and treatment of hypertension and decreasing cholesterol. Long term consumption ofClerodendron trichotomumThunberg leaf and flower tea can be help in lowering high systolic and blood diastolic pressure, heart rate and blood serum in SHR.

Design and Implementation of Transformerless 40W LED Light Driver Circuit for Ships (선박용 변압기 없는 40W LED 조명 구동회로의 설계 및 구현)

  • Song, Jong-Kwan;Park, Jang-Sik;Yoon, Byung-Woo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.3
    • /
    • pp.485-490
    • /
    • 2012
  • In this paper, driver circuit of LED lights for ships is designed and implemented to replace conventional lights with filament which have short life time due to vibration of ships. The driver of LED module is switching circuit without transformer to reduce volume and cost. As switch circuit controls input 220 VAC with PWM, LED module is reliably driven. Power factor is improved by using valley-fill PFC compensation circuit which is handled to pulse current of switching circuit. Serial-parallel LED circuit is applied to reduce change period of lights of long-term navigation ships. Array of serial-parallel can operate even if some of LEDs is damaged. It is suitable for ships that power consumption and power factor of lights including developed drive circuit have 39Watt and 0.925 respectively.

An Effect of Guided Imagery on Pain (통증에 대한 지시적 심상요법의 효과 - 대학생을 중심으로 -)

  • Kim Joo-Hyun
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.5 no.1
    • /
    • pp.20-38
    • /
    • 1999
  • This study is conducted to test an effect of the guided Imagery program on artificially induced pain and to develop an effective nursing intervention for patients with pain. The subjects of this study were 37 normal female university students. The data were collected from September 1998 to December 1998. And two group non-equal quasi -experimental research with pre and post design was used in this study, The data were analyzed with the SPSS $PC^+$ program with percentage, t-test, paired t-test and ANCOVA. The results of this study were as follows : 1. There are no significant differences of systolic blood pressure between groups. 2. The experimental group showed significantly lower diastolic blood pressure than control group after treatment. 3. There are no significant differences of pulse rate between groups. 4. The experimental group showed significantly higher body temperature than control group after treatment. 5. There are no significant differences of pain intensity between groups. 6. There are no significant differences of pain sensation between groups. 7. There are no significant differences of perceived pain tolerance time between groups. 8. The experimental group showed significantly longer real pain tolerance time than control group after treatment. 9. There are no significant differences of anxiety scores between groups. 10. There are no significant differences of Self-esteem scores between groups. 11. There are no significant differences of Self-esteem scores between groups. 12. There are no significant differences of imagability scores between groups. 13. The post-experimental group showed significantly higher relaxation rate than pre -experimental group. 14. There are no significant differences of imaging depth degree between pre-experimental group and post-experimental group. From the above results, it can be concluded that 1. This guided imagery program could be recommenced as an effective nursing intervention to relieve pain. 2. A follow up study is needed to identify long-term effects.

  • PDF