• 제목/요약/키워드: Long pulse

검색결과 444건 처리시간 0.043초

IGBT 기반 고압 펄스전원장치 (Pulsed Power Modulator based on IGBTs)

  • Ryoo, H.J.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.43-46
    • /
    • 2007
  • In this paper, a novel new pulse power generator based on IGBT stacks is proposed for pulse power application. Proposed scheme consists of series connected 9 power stages to generate maximum 60kV output pulse and one series resonant power inverter to charge DC capacitor voltage. Each power stages are configured as 8 series connected power cells and each power cell generates up to 850VDC pulse. Finally pulse output voltage is applied using total 72 series connected IGBTs. The synchronization of gating signal is important for series operation of IGBTs. For gating signal synchronization, full bridge inverter and pulse transformer generates on-off signals of IGBT gating and specially designed gate power circuit was used. Proposed scheme has lots of advantages such as long lifecyle, compact size, flat topped pulse forming, small weight, protection for arc, high efficiency and flexibility to generate various kinds of pulse output.

  • PDF

후방 충돌 펄스와 NCAP 펄스 차이로 인한 목상해 특성 비교 (Compare Characteristics of Neck Injuries between Rear Impact Pulse and NCAP Pulse)

  • 김종곤;박종호
    • 자동차안전학회지
    • /
    • 제9권3호
    • /
    • pp.7-12
    • /
    • 2017
  • The whiplash is the most important issue of low speed rear-impact. So auto makers are committed to developing a seat to improve whiplash injury. Most NCAP tests have been used by same pulse (Mid Velocity 16kph). Only Euro NCAP uses different pulse that consists of Low, Mid, High velocity. But Euro NCAP also uses same pulse in Mid velocity as other NCAP test. That Mid velocity NCAP pulse was made by rear impact that has 90's vehicle structure properties. That pulse was used until now days. However these days, auto maker use more high tensile steel than 90's as customer and society demand more fuel efficiency and light vehicle with good safety structure. So modern vehicles have different pulse patterns of rear impact than NCAP pulse and 90's vehicle crash properties. In this paper, the test was conducted by following condition. Target car was impacted by the rigid barrier with certain velocity. Finally target vehicle gained delta V 16kph which was same velocity as NCAP Mid Velocity pulse. It is critical velocity which occur long period neck injury. It is very different pulse that was gained by real car impact from NCAP pulse. And it has higher peak G with high fluctuation and short duration than NCAP pulse.

USB Driver 전송시스템 기반의 맥파 측정 시스템에 관한 연구 (A Study on Pulse Wave Measurement System Based on USB Driver Transmission System)

  • 김은근;박미경;한승신;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1914-1915
    • /
    • 2007
  • The period and strength of the pulse on the radial artery are important physiological factors, and they have been used to diagnosis in both Western and Eastern countries for a long time and has been developed as a unique method of diagnosis at each countries. Recently, there are a lot of systems which can give diagnosis information by recording the pulse wave and analyzing the characteristics of the pulse shape. This study describes the Pulse-Wave Measurement System which is able to measure the pulse wave signal using piezoresistive sensor and the pulse wave signal measured by the developed system is transmitted to a computer on the basis of the USB Driver. It has finally shown the the pulse wave signal measured by the sender is appeared to the host PC in real time. The Pulse-Wave Measurement System used the piezoresistive sensor to measure the pulse wave signal and the differential amplifier(AD620) to amplify the pulse wave signal which is small signal. And it used the ADC to convert analog to digital for the measured analog signal and the interface with a computer. It transmitted the measured pulse signal through USB transmission module to the host computer and Labview tool shows it. This Pulse-Wave measurement system will afford comvenience of detecting pulse wave to user related to oriental medicine.

  • PDF

한국에 서식하는 곤박쥐 Rhinolophus ferrumequinum, 집박쥐 Pipistrellus abramus, 큰발윗수염박쥐 Myotis macrodactylus의 반향정위 형태 (General Patterns in Echolocation Call of Greater Horseshoe Bat Rhinolophus ferrumequinum, Japanese Pipistrelle Bat Pipistrellus abramus and Large-Footed Bat Myotis macrodactylus in Korea)

  • 정철운;한상훈;임춘우;김성철;이화진;권용호;김철영;이정일
    • 한국환경과학회지
    • /
    • 제19권1호
    • /
    • pp.61-68
    • /
    • 2010
  • In this study, we analyzed the pulse-duration, pulse-interval and peak-frequency of echolocation call in three species as Rhinolophus ferrumequinum, Pipistrellus abramus, and Myotis macrodactylus. The peak frequency and pulse duration for above mentioned species were 69 kHz, 47 kHz and 49 kHz and $69.39{\pm}8.76\;ms$, $4.95{\pm}0.77\;ms$ and $3.09{\pm}0.48\;ms$ for R. ferrumequinum, P. abramus and M. macrodactylus, respectively. The pulse intervals for R. ferrumequinum, P. abramus and M. macrodactylus were $103.61{\pm}9.05\;ms$, $67.59{\pm}3.47\;ms$ and $66.35{\pm}4.96\;ms$, respectively. The pulse pattern of R. ferrumequinum was setting into a short FM call and linked to long CF call and went through the short FM call again. The pulse pattern of M. macrodactylus was comprised with serial short FM call and the CF call was not checked up in accordance with the spectrogram analysis. The long FM call and short CF call got join together for the P. abramus and the peak frequency was checked up at the pulse ending as CF call.

부분방전 교정펄스 발생기의 표준화 시스템구축과 불확도 (Setup and Uncertainty of Standard System for Calibrating Pulse Generator of Partial Discharge)

  • 김광화;이상화;이헌진;강동식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1355_1357
    • /
    • 2009
  • This paper describes the standard system for calibrating pulse generator of partial discharge(PD) and its uncertainty. The system is consisted of digital pulse generator, digital recorder and evaluation software. The uncertainty requirement of calibrator charge is less than $\pm$ (0.1pC + 0.03q) and that of pulse duration is less than $\pm$ 10 %. The system can generate various kind of calibration pulses such as single pulse, double pulses, oscillation pulse, long-duration pulse, random pulses and evaluate their uncertainty.

  • PDF

Effect of Auxiliary Address Pulse on Face-to-face Sustain Electrode Structure in AC-PDP

  • Kim, Bo-Sung;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.605-608
    • /
    • 2007
  • The discharge characteristics of the face-to-face sustain electrode structure employing auxiliary address pulse are investigated under a sustain driving frequency of 20 kHz and various auxiliary address pulse widths (500 ns, $1{\mu}s$, $2\;{\mu}s$) in the 6-in. test panel (42-in. Full HD grade) with a pressure of 450 Torr and a 4 % Xe-content. The luminance and the luminous efficiency at the auxiliary address pulse width of 500 ns are improved more than these of $1\;{\mu}s$ and $2\;{\mu}s$. At the auxiliary address pulse width of 500 ns, the luminous efficiency shows about 0.96 lm/W at the auxiliary pulse of 90 V and the sustain voltage of 260 V.

  • PDF

Smart passive control of buildings with higher redundancy and robustness using base-isolation and inter-connection

  • Murase, Mitsuru;Tsuji, Masaaki;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • 제4권6호
    • /
    • pp.649-670
    • /
    • 2013
  • It is known that a base-isolated building exhibits a large response to a long-duration, long-period wave and an inter-connected system without base-isolation shows a large response to a pulse-type wave. To compensate for each deficiency, a new hybrid passive control system is investigated in which a base-isolated building is connected to another building (free wall) with oil dampers. It is demonstrated that the present hybrid passive control system is effective both for pulse-type ground motions and long-duration and long-period ground motions and has high redundancy and robustness for a broad range of disturbances.

인영촌구비교맥진(人迎寸口比較脈診)에 관한 연구 (A Study on Comparative Pulse Diagnosis of Renying Pulse(人迎脈) and Cunkou Pulse(寸口脈))

  • 윤창열
    • 대한한의학원전학회지
    • /
    • 제32권4호
    • /
    • pp.35-46
    • /
    • 2019
  • Objectives : While Comparative Pulse Diagnosis of Renying pulse(人迎脈) and Cunkou pulse(寸口脈) is one of the three major pulse diagnostic methods in "Huangdineijing" along with Three Positions and Nine Indicators Pulse Diagnosis(三部九候脈診法) and Cunkou Pulse Diagnosis(寸口脈診法), it has died out in later periods. This study aims to examine this lost method. Methods : Annotations of "Huangdineijing" were examined along with descriptions of the author's own experience. Results & Conclusions : Renying is the Renying(人迎) point from the Stomach Channel(ST), while Cunkou is the Taiyuan(太淵) point from the Lung Channel(LU). These two points are compared in order to determine the deficiency and excess of the Zangfu(臟腑). Normal pulses(平脈) are Soft(軟脈) or Moderate(緩脈), while Stirred pulses(躁脈) are Stringy(弦脈), Tight(緊脈), Slippery(滑脈) or Long(長脈). If the Renying is once active where Shaoyang pulse is active, purge the Gallbladder and supplement the Liver. If there is Stirred pulse, purge the Triple Burner and supplement the Pericardium. If the Renying is twice active where Taiyang pulse is active, purge the Bladder and supplement the Kidney. If there is Stirred pulse, purge the Small Intestine and supplement the Heart. If the Renying is three times active, where Yangming pulse is active, purge the Stomach and supplement the Spleen. If there is Stirred pulse, purge the Large Intestine and supplement the Lung. If the Cunkou is once active where the Jueyin pulse is active, purge the Liver and supplement the Gallbladder. If there is Stirred pulse, purge the Pericardium and supplement the Triple Energizer. If the Cunkou is twice active where the Shaoyin pulse is active, purge the Kidney and supplement the Bladder. If there is stirred pulse, purge the Heart and supplement the Small Intestine. If the Cunkou is three times active where the Taiyin pulse is active, purge the Stomach and supplement the Spleen. If there is Stirred pulse, purge the Lung and supplement the Large Intestine.

Effect of auxiliary electrode on the discharge characteristics in AC PDP with long sustain-gap

  • Park, Sang-Dae;Lee, Seung-Hun;Shin, Nam-Hoon;Lee, Kyo-Sung;Park, Sung-Yun;Kim, Sang-Ho;Shin, Bhum-Jae;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.109-112
    • /
    • 2004
  • The effect of auxiliary electrode on the discharge characteristics in AC PDP with long sustain-gap was investigated. The auxiliary electrode was placed between scan and common electrode. When the pulse was applied to the auxiliary electrode during sustain period, the luminance of Ne + 13%Xe gas-mixture discharge increased and the discharge current decreased. The auxiliary pulse plays a role of improving electron excitation efficiency. When the auxiliary pulse was applied during address period, the address discharge time lag of Ne + 13%Xe gas-mixture could be reduced remarkably.

  • PDF

MEASUREMENT OF LONG IMPULSE RESPONSE BY USING A TIME-STRETCHED PULSE

  • Kim, Hack-Yoon;Asano, Futoshi;Suzuki, Yoiti;Sone, Toshio
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.867-872
    • /
    • 1994
  • The transfer function of an acoustic system, in general, often exhibits a wide dynamic range and a very long impulse response. The time-stretched pulse (TSP) proposed by Aoshima (ATSP) has a small peak-factor and is accordingly suitable for the measuring impulse responses. The pulse is not so suitable, however, for the measurement of impulse responses over a wide frequency range. In this paper, we try to generalize and optimize this method (OATSP). This makes the method applicable for measuring of impulse responses longer than the length of the TSP. An analysis of error in such a case is also shown. Finally, we discuss how to implement this technique in specific measurement conditins.

  • PDF