• Title/Summary/Keyword: Long Axis

Search Result 733, Processing Time 0.022 seconds

Anthropometry of Nose in Korean Twenties (20대 한국인 코의 계측치)

  • Bae, Tae Hui;Yu, Young Il;Kim, Woo Seob;Kim, Han Koo
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.2
    • /
    • pp.61-66
    • /
    • 2009
  • Purpose: The aim of this study is to establish anatomical dimension of the nose and nostril shape in Korean twenties. Methods: Authors measured anthropometry of nose in Korean youths 1,000 individuals (male 363, female 637) and analyzed stastically them. Results: The mean measurements are as follows. 1. The shape of nostrils was classified into 7 types by the angle between both long axis of nostril (male / female). Type I ($<40^{\circ}$)1.7% / 1.72%, Type II ($41-70^{\circ}$) 26.17% / 29.35%, Type III ($71-100^{\circ}$) 39.94% / 38.77%, Type IV (unclassified) 3.85% / 5.80%, Type V ($101-130^{\circ}$) 20.93% / 17.89%, Type VI ($131-180^{\circ}$) 7.43% / 5.96%, Type VII ($>180^{\circ}$) 0% / 0.47% 2. Lengths (male/female) Width of nasal root: $25.29{\pm}2.25mm/24.72{\pm}2.40mm$ Width of nose: $37.63{\pm}2.46mm/34.77{\pm}2.11mm$ Width of columella: $7.18{\pm}0.92mm/6.92{\pm}0.86mm$ Width of alar: $4.99{\pm}1.00mm/4.74{\pm}0.91mm$ Width of nostril floor: $10.98{\pm}1.40mm/10.13{\pm}1.73mm$ Protrusion of nasal tip: $17.12{\pm}1.95mm/16.88{\pm}1.84mm$ Length of alar: $27.10{\pm}2.21mm/24.66{\pm}2.18mm$ Length of nasal root: $17.37{\pm}2.51mm/16.08{\pm}2.90mm$ Depth of nasal root: $7.83{\pm}1.63mm/6.82{\pm}1.36mm$ Length of columella: $8.13{\pm}1.40mm/7.30{\pm}1.46mm$ Height of nose: $60.50{\pm}8.90mm/59.14{\pm}9.22mm$ Height of nasal bridge: $52.68{\pm}7.49mm/50.57{\pm}7.71mm$ 3. Angles Nasofacial angle: $30.19{\pm}3.43^{\circ}/29.13{\pm}6.31^{\circ}$ Nasofrontal angle: $134.88{\pm}7.25^{\circ}/139.94{\pm}6.33^{\circ}$ Nasolabial angle: $95.08{\pm}8.95^{\circ}/95.80{\pm}8.93^{\circ}$ 4. Nasal index: $72.60{\pm}9.57%/68.21{\pm}7.03%$ Nasal tip protrusion-nasal height index: $45.64{\pm}5.21%/47.09{\pm}5.21%$ Nasal tip protrusion-nasal width index: $32.61{\pm}6.83%/31.63{\pm}6.71%$ Conclusion: These data could be useful reference for anthropometry of nose in Korean twenties.

Molecular Cloning, Tissue Distribution and Segmental Ontogenetic Regulation of b0,+ Amino Acid Transporter in Lantang Pigs

  • Zhi, Ai-Min;Feng, Ding-Yuan;Zhou, Xiang-Yan;Zou, Shi-Geng;Huang, Zhi-Yi;Zuo, Jian-Jun;Ye, Hui;Zhang, Chang-Ming;Dong, Ze-Min;Liu, Zhun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.8
    • /
    • pp.1134-1142
    • /
    • 2008
  • Cationic amino acid transporter $b^{0,+}AT$ (HGMW-approved gene symbol SLC7A9, solute carrier family 7, member 9) plays a crucial role in amino acid nutrition. In the present study, we describe the cloning and sequencing of porcine $b^{0,+}AT$. Based on the sequence of porcine $b^{0,+}AT$ deposited in the NCBI (National Center for Biotechnological Information), we identified a putative porcine homologue. Using rapid amplification of cDNA ends (RACE), the full-length cDNA encoding porcine $b^{0,+}AT$ was isolated. The porcine $b^{0,+}AT$ cDNA was 1,680 bp long, encoding a 487 amino acid trans-membrane protein. The predicted amino acid sequence was found to have 88.9% and 87.1% identity with human and mouse $b^{0,+}AT$, respectively. Real-time RT-PCR indicated porcine $b^{0,+}AT$ transcripts expressed in heart, kidney, muscle and small intestine. The small intestine had the highest $b^{0,+}AT$ mRNA abundance while the muscle had the lowest (p<0.05). Along the longitudinal axis, the ileum had the highest $b^{0,+}AT$ mRNA abundance while the colon had the lowest (p<0.05). The $b^{0,+}AT$ mRNA level was highest on day 7 and 90 in the duodenum (p<0.05). It increased from day 1 to day 26 in the jejunum (p>0.05) and had the highest abundance on day 60 (p<0.05). There was, however, no difference between day 1, 7, 26, 30, 90 and 150 (p>0.05). The strongest $b^{0,+}AT$ expression appeared on day 7 in the ileum before weaning, and then decreased till day 30 but rose gradually again from day 60 to 150 (p<0.05).

THE INVESTIGATION OF MICROVASCULATURE CHANGES IN OSSEOUS REGENERATION BY GUIDED TISSUE REGENERATION PROCEDURE (골재생유도술에 의한 골재생시 미세혈관 구축 양상)

  • Choi, Du-Hee;Ryoo, Hyun-Mo;Shin, Hong-In
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.3
    • /
    • pp.257-265
    • /
    • 1999
  • To investigate the sequential changes in microvascular architecture and osseous regeneration during the bony healing after an application of the guided tissue regeneration method, we made artificial defects measuring $0.7cm{\times}0.3cm$ in size on femoral bones of rats measuring about 200gm and applied non-absorbable TEFE membrane at experimental sites but not at control sites. Then we observed the sequential changes and correlations between new vacuolation and bony regeneration using microvascular corrosion cast method and routine light microscopic observation at 1, 2 and 3 weeks after operation, respectively. The results showed that there were close relationships between regeneration of microvasculature and bone. In early phase, the invasion of granulation tissue at control sites delayed bony regeneration, however, in later phase, there was no remarkable differences in bony regeneration between control and experimental sites. The placement of barrier also affected in revascularization of regenerating bony defects. This is, the experimental sites showed parallel arranged nutritional vessels along long axis with well developed retiform plexus whereas the control revealed vertical invasion of microvasculature from outside of marrow space through bony defects which was also rearrange with time into parallel pattern with a vertical plexus but lesser organized than that of experimental sites. These findings suggest that the reconstruction of regenerating vasculature within the marrow cavity only may be sufficient and/or more be efficient in regeneration of bony defects.

  • PDF

Effect of different adhesive systems and post surface treatments on the push-out bond strengths of fiber-reinforced post (다양한 접착 시스템 및 포스트의 표면 처리가 섬유 강화 포스트의 접착 강도에 미치는 영향)

  • Kim, Min-Woo;Ahn, Jin-Hee;Kim, Lee-Kyoung;Shim, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.218-225
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate the push-out bond strength of glass-fiber post cemented with different adhesive systems and surface treatments. Materials and methods: 160 tooth samples made from 48 human maxillary single-rooted teeth with similar root length were divided into 4 groups according to the adhesive system (no adhesive, Adper Single Bond 2, Clearfil SE Bond, Clearfil S3). Each group had 4 subgroups according to the post surface treatment methods (no treatment, sandblast, silane, sandblast and silane). Posts (Parapost Fiber White) were cemented with Rely X Unicem. The teeth were sectioned perpendicular to their long axis into 1-mm thick sections. The push-out tests was performed at a speed of 0.5 mm/min. The results were evaluated by 2-way ANOVA, 1-way ANOVA and multiple comparison procedures (Tukey test) (${\alpha}=0.05$). Results: Tukey test showed that the adhesive system significantly influenced the push-out strength. The Clearfil SE Bond group showed the highest value. Post surface treatments showed no significant effect. Conclusion: Bond strength of glass-fiber post cemented with self-adhesive resin cement using Clearfil SE Bond showed significantly higher values compared to other adhesive systems.

Study on a Propulsion Control of the Roller Coasters Train based on Air Cored Linear Synchronous Motor (공심형 선형동기전동기 기반의 궤도열차 추진제어에 관한 연구)

  • Jo, Jeong-Min;Han, Young-Jae;Lee, Jin-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8187-8194
    • /
    • 2015
  • To accelerate a heavy roller coaster train with over 1G force, a lot of thrust is required and linear synchronous motor(LSM) as propulsion method is suitable for this kind of system. To increase the propulsion efficiency of LSM, precise and real-time position information of vehicle is required for accurate phase control. However, the discontinuous position information with relatively long time interval is usually transmitted from the hall-sensors on the track every magnet length. In this paper, the basic motor model based on traditional dq-axis equations is described and the motor dynamic model is produced by considering the cogging force and friction loss. To improve the position accuracy, the position estimator is also proposed for LSM control system. Simulations were performed to check the characteristics of the torque control system which includes the position estimator based on the motor model. Simulation results based on the linearized model show that this control system has an enough bandwidth and phase margin and the executed algorithm achieves an ideal effect to follow the real-time position signal. Therefore, the feasibility of position estimator is also confirmed.

FRACTURE STRENGTH AND FRACTURE MODE OF RESIN ROOT ANALOGS RESTORED WITH VARIOUS POST AND CORE MATERIALS

  • Lee, Byung-Chul;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho;Lee, Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.3
    • /
    • pp.287-295
    • /
    • 2002
  • Statement of Problem. Endodontically treated teeth frequently required posts and cores to provide retention and resistance form for crowns. In spite of excellent mechanical properties of metal post and core, its metallic color can be detected through all ceramic restorations occasionally. To solve esthetic problems of metal post and core zirconia post system has been introduced recently. Purpose. The purpose of this study was to examine the fracture strength and mode of resin root analogs restored with zirconia, gold and titanium posts with resin, ceramic and metal cores after cementation with metal crowns. Materials and methods. To avoid the morphological variations of natural teeth, 40 root analogs were fabricated with composite resin. Forty resin root analogs were randomly assigned to four groups according to post and core materials: Group A: cast gold post and core and complete cast crowns, as control. Group B: titanium posts (Parapost, Coltent/Whaledent Inc., NJ, USA) and composite resin cores. Group C: zirconia posts (Cosmopost, Ivoclar AG, Schaan/Liechtenstein) and composite resin cores Group D: zirconia posts and heat-pressed ceramic cores (IPS Empress Cosmo Ingots, Ivoclar AG) After thermocycling ($5^{\circ}C{\sim}55^{\circ}C$, 30 sec.), cyclic loading was applied at 3mm below the incisal edge on the palatal surfaces at an angle of 135 degree to the long axis (2Hz, 50N, 50000cycles). Fracture strength was measured by universal testing machine (Instron, High Wycombe, UK) and fracture pattern of restored resin root analogs was also evaluated. Results and conclusion. Within the limitations of this study following results were drawn. 1. Resin root analogs restored with zirconia posts and composite resins demonstrated lowest fracture strength among tested groups. 2. There was no significant difference in the fracture strength between zirconia posts and heat pressed glass ceramic cores and cast gold posts and cores 3. The fracture strength of resin root analogs restored with titanium posts and composite resin cores was lower than that of gold posts and cores. 4. The deep oblique fracture lines were dominantly observed in root analogs restored with cast gold post and core and zirconia post and heat-pressed ceramic core groups.

FINITE ELEMENT ANALYSIS OF THE INFLUENCE OF ESTHETIC POSTS ON INCISORS (심미 포스트가 전치에 미치는 응력과 변위에 관한 삼차원 유한요소법적 분석)

  • Kwon Tae-Hoon;Hwang Jung-Won;Kim Sung-Hun;Shin Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.5
    • /
    • pp.582-595
    • /
    • 2003
  • Statement of problem : Most posts are metallic, but in response to the need for a post that possesses optical properties compatible with an all-ceramic crown. an esthetic post has been developed. Although there have been many studies about the esthetic post materials, 3-dimensional finite element studies about the stress distribution of them are in rare. Purpose : The purpose of this study is to investigate comparatively the distribution of stresses of the restored, endodontically treated maxillary incisors with the esthetic post materials and the displacement on the cement layer on simulated occlusal loading by using a 3-dimensional finite element analysis model. Material and method : Four 3-dimensional finite element models were constructed in a view of a maxillary central incisor, a post, a core, and the supporting tissues to investigate the stresses in various esthetic posts and cores and the displacement on the cement layer (Model 1 ; Cast gold post and core, Model 2 ; Glass fiber post with composite core, Model 3 ; Zirconia post with composite core. Model 4 ; Zirconia post with ceramic core). Force of 300N was applied to the incisal edge and the cingulum (centric stop point) with the angle of 135-degree to the long axis of the tooth. Results : 1. The stresses and displacement on the incisal edge were higher than on the cingulum 2. The stresses in dentin were the highest in Model 2 (Glass fiber post with composite core), and the second was Model 3, the third Model 1, and the lowest Model 4. 3. The stresses in post and core were the highest in Model 4 (Zirconia post with ceramic core), and the second was Model 1, the third Model 3, and the lowest Model 2. 4. The displacement on the cement layer was the highest in Model 2 (Glass fiber post with composite core), and the second was Model 3, the third Model 1, and the lowest Model 4. Conclusion : When a functional maximum bite force was applied, the distribution of stresses or the esthetic post and core materials and the displacement on the cement layer were a little different. It seems that restoring extensively damaged incisors with esthetic post and core materials would be decided according to the remaining tooth structure.

Gender Differences in Achievement of Earth and Environmental Area in PISA 2000 (OECD 주관 학생 성취도 국제 비교 연구(PISA 2000) 지구 환경 과학 영역 성취도에서의 성(性) 차이)

  • Shin, Dong-Hee;Park, Chung;Ro, Koog-Hyang
    • Journal of The Korean Association For Science Education
    • /
    • v.22 no.1
    • /
    • pp.40-53
    • /
    • 2002
  • This study was based on the analysis of earth and environmental science items in PISA 2000 data. The purpose of this study was to identify i) gender differences in scientific literacy, ii) item characteristics that favored either female or male, and iii) misconceptions that 15-years-old Korean students have in the field of earth and environmental science. The results revealed significant gender differences. Overall, male students demonstrated higher level of achievement than female students. On the other hand, amongst high ability students, female students outperformed male students in open-constructed items. Female students tended to score higher on items that required long answers or items related to scientific processes, whereas male students outperformed female students in science knowledge or items that required data interpretation. The study also revealed that a majority of Korean students had misconceptions in fundamental earth and environmental science knowledge, such as the direction of earth's axis and equator, and the causes of Greenhouse Effect.

The compressive fracture strength of ceromer crown by the difference of occlusal thickness (Ceromer crown의 교합면 두께에 따른 압축 파절 강도의 비교)

  • Kim, Jee-Yeon;Park, Ha-Ok;Yang, Hong-So
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.205-215
    • /
    • 2002
  • This study investigated the compressive fracture strength of Targis ceromer crown by the difference of occlusal thickness on a maxillary first premolar. Control group was a castable IPS-Empress all-ceramic crown with occlusal thickness of 1.5 mm constructed by layered technique. Experimental groups were Targis crowns having different occlusal thicknesses of 1.0 mm, 1.5 mm, 2.0 mm, 2.5 mm, respectively. The classification of Targis group is T10, T15, T20, T25 and T15N (for no-thermocycling and occlusal thickness of 1.5mm). Ten samples were tested per each group. Except occlusal thickness, all dimension of metal die is same with axial inclination of $10^{\circ}$and marginal width 0.8mm chamfer. All crowns were cemented with Panavia F and thermocycled 1,000 times between $5^{\circ}$ and $55^{\circ}$ water bath with 10 sec dwelling time and 10 sec resting time. The compressive fracture strength was measured by universal testing machine. The results were as follows : 1. Fracture strength was increased as the occlusal thickness increased : compressive fracture strength of Group T10, T15, T20, T25 was $66.65{\pm}4.88kgf$, $75.04{\pm}3.01kgf$, $87.07{\pm}7.06kgf$ and $105.03{\pm}10.56kgf$, respectively. 2. When comparing material, Targis crown had higher fracture strength than IPS-Empress crown : the mean compressive strength of group T15 was $75.04{\pm}3.01kgf$ and the value of group Control was $37.66{\pm}4.28kgf$. 3. Fracture strength was decreased by thermocycling : the compressive fracture strength of T15 was $75.04{\pm}3.01kgf$, which is lower than $90.69{\pm}6.88kgf$ of group T15N. 4. The fracture line of crowns began at the loading point and extended along long axis of tooth. IPS-Empress showed adhesive failure pattern whereas Targis had adhesive and cohesive failure. In the SEM view, stress was distributed radially from loading point and the crack line was more prominent on Targis crown.

Detection of Subsurface Ancient Remains in Sooseong Dang Area, Buan Using Ground Penetration Radar Technique (지하투과레이다 기법을 이용한 부안 수성당 지역의 지하 유적 탐사)

  • Lee, Hyoun-Jae;Jeon, Hang-Tak;Yun, Sul-Min;Hamm, Se-Yeong
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.553-563
    • /
    • 2019
  • In order to survey archaeological sites, drilling and excavation are carried out at the final stage. However, at the preliminary stage, non-excavation geophysical prospection is used for assessing underground archaeological ruins. Among the geophysical prospecting techniques, Ground Penetration Radar (GPR) prospection has effectively been applied to historical sites due to its high resolution at shallow depths. In this study, the GPR prospection was conducted to find underground ruins near Suseong-Dang, the place of ancient rituals in Buan area, Korea. First, the GPR prospection was conducted at three sites (Site-1, 2, and 3), and subsequently, the GPR prospection was carried out at Site-3 in more detail. As a result of the prospection, the underground layered structure of the survey area consists of three layers, which are soil layer, weathered rock, and sound rock from the surface. And the GPR anomaly to the archaeological structure was clearly identified at around 100-cm depth showing est-west direction that is parallel to the long-axis array. This GPR anomaly of irregular geomorphological features and intermittent distribution may be related to the ritual remains found in Suseong Dang. The GPR prospection could be effectively used to detect archaeological sites or remains buried in the ground.