• Title/Summary/Keyword: Long Axis

Search Result 732, Processing Time 0.03 seconds

Seed Morphological Characteristics and Dormancy type of Eranthis stellata Maxim., Korea Rare Plant. (희귀식물 너도바람꽃(Eranthis stellata Maxim.) 종자의 형태특성 및 휴면유형 분석)

  • Inhwan Chae;Geon Hui Ryu;Se-kyu Song;Jin-Woo Kim;Gi Ho Kang;Hayan Lee
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2020.08a
    • /
    • pp.20-20
    • /
    • 2020
  • Eranthis stellata Maxim. is a perennial plant that grows around the valley. E. stellata is concerned about the decline in natural habitats due to climate change in KOREA, continues to be observed and protected as an endangered species (Least Concrned, LC). Nevertheless, studies on the characteristics of the seeds of E. stellata are insufficient. So, this study analyzed the morphological characteristics and dormancy types of seeds. Seeds of E. stellata was collected in April at Gyeongsangbuk-do Arboretum and kept at 5 ℃ until using. To investigate the morphology of seeds, an optical microscope and a scanning electron microscope (SEM) were used. GA3 treated or untreated seeds (4 replicates of 25 seeds each) were observed germination and embryo growth for 1 month at 5 ℃ and 25/15 ℃ (12h day/12h night). The seed surface of E. stellata, light brown, was observed as a common characteristic of Eranthis genus, reticulate. The short axis of seeds was 1.11~1.77mm (average 1.44mm), and the long axis was 1.27~1.91mm (average 1.63mm), which was investigated in a slightly round shape (subglose). While no germination was observed at all conditions, Embryo growth was observed at 5 ℃ both in the control group and with GA3treated groups. Thus, seeds of E. stellata are classified as morphological physiological dormancy (MDP), which requires embryonic development and dormant break at the same time. These results can be useful information for determining morphological physiological seed dormancy and germination, and will be an important basic data for seed propagation of E. stellata as a resource.

  • PDF

LOXL1-AS1 Aggravates Myocardial Ischemia/Reperfusion Injury Through the miR-761/PTEN Axis

  • Wenhua He;Lili Duan;Li Zhang
    • Korean Circulation Journal
    • /
    • v.53 no.6
    • /
    • pp.387-403
    • /
    • 2023
  • Background and Objectives: Myocardial ischemia and reperfusion injury (MIRI) has high morbidity and mortality worldwide. We aimed to explore the role of long noncoding RNA lysyl oxidase like 1 antisense RNA 1 (LOXL1-AS1) in cardiomyocyte pyroptosis. Methods: Hypoxia/reoxygenation (H/R) injury was constructed in human cardiomyocyte (HCM). The level of LOXL1-AS1, miR-761, phosphatase and tensin homolog (PTEN) and pyroptosis-related proteins was monitored by quantitative real-time polymerase chain reaction or western blot. Flow cytometry examined the pyroptosis level. Lactate dehydrogenase (LDH), creatine kinase-MB and cardiac troponin I levels were detected by test kits. Enzyme-linked immunosorbent assay measured the release of inflammatory cytokines. Dual-luciferase assay validated the binding relationship among LOXL1-AS1, miR-761, and PTEN. Finally, ischemia/reperfusion (I/R) animal model was constructed. Hematoxylin and eosin staining assessed morphological changes of myocardial tissue. NOD-like receptor pyrin domain-containing protein 3 (NLRP3) and casepase-1 expression was determined by immunohistochemistry. Results: After H/R treatment, LOXL1-AS1 and PTEN were highly expressed but miR-761 level was suppressed. LOXL1-AS1 inhibition or miR-761 overexpression increased cell viability, blocked the release of LDH and inflammatory cytokines (interleukin [IL]-1β, IL-18), inhibited pyroptosis level, and downregulated pyroptosis-related proteins (ASC, cleaved caspase-1, gasdermin D-N, NLRP3, IL-1β, and IL-18) levels in HCMs. LOXL1-AS1 sponged miR-761 to up-regulate PTEN. Knockdown of miR-761 reversed the effect of LOXL1-AS1 down regulation on H/R induced HCM pyroptosis. LOXL1-AS1 aggravated the MIRI by regulating miR-761/PTEN axis in vivo. Conclusions: LOXL1-AS1 targeted miR-761 to regulate PTEN expression, then enhance cardiomyocyte pyroptosis, providing a new alternative target for the treatment of MIRI.

LncRNA PART1 Attenuates Myocardial Ischemia-Reperfusion Injury by Regulating TFAP2C/DUSP5 Axis via miR-302a-3p

  • Min Zeng;Xin Wei;Jinchao Zhou;Siqi Luo
    • Korean Circulation Journal
    • /
    • v.54 no.5
    • /
    • pp.233-252
    • /
    • 2024
  • Background and Objectives: Myocardial ischemia-reperfusion injury (MIRI) refers to the damage of cardiac function caused by restoration of blood flow perfusion in ischemic myocardium. However, long non-coding RNA prostate androgen regulated transcript 1 (PART1)'s role in MIRI remain unclear. Methods: Immunofluorescence detected LC3 expression. Intermolecular relationships were verified by dual luciferase reporter assay. 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide, flow cytometry and transferase-mediated dUTP nick-end labeling (TUNEL) assays analyzed cell viability and apoptosis. The release of lactate dehydrogenase was tested via enzyme-linked immunosorbent assay (ELISA). Left anterior descending coronary artery surgery induced a MIRI mouse model. Infarct area was detected by 2,3,5-triphenyltetrazolium chloride staining. Hematoxylin and eosin staining examined myocardial injury. ELISA evaluated myocardial marker (creatine kinase MB) level. Results: PART1 was decreased in hypoxia/reoxygenation (H/R) induced AC16 cells and MIRI mice. PART1 upregulation attenuated the increased levels of Bax, beclin-1 and the ratio of LC3II/I, and enhanced the decrease of Bcl-2 and p62 expression in H/R-treated cells. PART1 upregulation alleviated H/R-triggered autophagy and apoptosis via miR-302a-3p. Mechanically, PART1 targeted miR-302a-3p to upregulate transcription factor activating enhancer-binding protein 2C (TFAP2C). TFAP2C silencing reversed the protected effects of miR-302a-3p inhibitor on H/R treated AC16 cells. We further established TFAP2C combined to dual-specificity phosphatase 5 (DUSP5) promoter and activated DUSP5. TFAP2C upregulation suppressed H/R-stimulated autophagy and apoptosis through upregulating DUSP5. Overexpressed PART1 reduced myocardial infarction area and attenuated MIRI in mice. Conclusion: PART1 improved the autophagy and apoptosis in H/R-exposed AC16 cells through miR-302a-3p/TFAP2C/DUSP5 axis, which might provide novel targets for MIRI treatment.

Comparison of defect size measured by transthoracic and transesophageal echocardiography with balloon occlusive diameter measured during transcatheter closure of atrial septal defect (경피적 심방중격결손 폐쇄술 시 경흉부 및 경식도 초음파 검사 상의 결손의 크기와 풍선 폐쇄 직경과의 관계)

  • Hur, Kyong;Kim, Jeong Eun;Kim, Yuria;Kwon, Hae Sik;Yoo, Byung Won;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.10
    • /
    • pp.970-975
    • /
    • 2007
  • Purpose : Accurate measurement of defect size is important in transcatheter closure of atrial septal defect (ASD). We performed this study to analyze the difference between the measured ASD size and balloon occlusive diameter (BOD) by transthoracic (TTE) or transesophageal echocardiography (TEE). Methods : We investigated 78 patients who underwent transcatheter closure of ASD. The defect size and the distance between the surrounding structures were measured by TTE and TEE. The BOD was measured by TEE during cardiac catheterization. Clinical characteristics and echocardiographic data were compared and analyzed. Results : The difference between BOD and diameter by TTE was $4.8{\pm}3.6mm$ on short axis view, $5.4{\pm}3.2mm$ on long axis view. The difference between BOD and diameter by TEE was $3.6{\pm}2.2mm$ on short axis view, $4.2{\pm}3.1mm$ on long axis view. The difference between BOD and the diameter of defects on TTE, TEE had statistically significant positive correlations with the age of the patients, distance between the, defect and posterior atrial septal wall, the distance between the defect and the mitral valve leaflet, and the diameter of defects and the length of the atrial septum on TTE (P<0.05). Conclusion : BOD of ASD can be estimated by the diameter on TTE and TEE. BOD is expected to measure larger, depending on the size of defects, the distance from surrounding structures and the location of defects on echocardiography. Our data offers important information on details of transcatheter ASD closure which can be helpful in predicting suitability and judging the procedural appropriateness during the procedure.

EVALUATION OF CONDYLAR DISPLACEMENT USING COMPUTER TOMOGRAPHY AFTER THE SURGICAL CORRECTION OF MANDIBULAR PROGNATHISM (전산화단층촬영법을 이용한 하악전돌증 환자의 외과적 악교정술후 하악과두 위치 변화 검토)

  • Lee, Ho-Kyung;Jang, Hyun-Jung;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.3
    • /
    • pp.191-200
    • /
    • 1998
  • This study was intended to perform the influence of condyle positional change after surgical correction of skeletal Class III malocclusion after orthognathic surgery in 37 patients(male 13, female 24) using computed tomogram that were taken in centric occlusion before, immediate after, and long term after surgery and lateral cephalogram that were taken in centric occlusion before, 7 days within the period of intermaxillary fixation, at the 24 hours later removing intermaxillary fixation and long term after surgery. 1. Mean intercondylar distance was $84.42{\pm}5.30mm$ and horizontal long axis of condylar angle was $12.79{\pm}4.92^{\circ}$ on the right, $13.53{\pm}5.56^{\circ}$ on the left side. Condylar lateral poles were located about 12mm and medial poles about 7mm away from the reference line(AA') on the axial tomogram. Mean intercondylar distance was $83.15{\pm}4.62mm$ and vertical axis angle of condylar angle was $76.28{\pm}428^{\circ}$ on the right, $78.30{\pm}3.79^{\circ}$ on the left. 2. In amount of set back, We found the condylar change(T2C-T1C) which had increasing tendency in group III (amount of setback : 10-15mm). but there was no statistical significance(p>0.05). 3. There was some correlation between condylar change(T2C-T1C) and TMJ dysfunction. It seemed that postoperative condylar change had influenced postoperative TMJ dysfunction, through there was no statistical significance (p>0.05). As we have observed the change of condylar axis in the group that complained of TMJ dysfunction in cases of large amount of mandibular setback. So we consider that the more trying to conserve condylar position will decrease occurrence rate of post operational TMJ dysfunction.

  • PDF

Application of the Equivalent-Field Method for Output Calculation: Is it safe for elongated x-ray fields\ulcorner (출력인자 계산에 이용되는 등가면법의 타당성 연구 : 장방형 X-선 조사면에 대해서 안전한가\ulcorner)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.195-200
    • /
    • 1998
  • Purpose: When an elongated x-ray field is used for treating a patient, the equivalent- field method is commonly used for the output calculation. This study is intended for investigating potential factors such as, beam quality, field elongation ratio, and depth of measurement, which might effect on the applicability of the equivalent square technique for output calculation. The derivation of a 'rule of thumb' for the application criteria of the equivalent-field method is also aimed. Materials and Methods: Three x-ray beams, 4-, 6- and 10-MV, were employed for this study. Width of the rectangular field was ranged from 5-40 cm and the elongation ratio (length/width) 1:0 to 10:0. An elongation effect was measured in a water phantom at three different depths, dmax, 5-cm, and 10-cm. For an elongated field and its equivalent square field, the output factor was measured and the difference in the output factor were examined between two fields. Results and Discussions: As the elongation ratio increases, a larger discrepancy in outputs is observed between the elongated rectangular field and its corresponding equivalent square field. Output was measured larger for an elongated field than for its corresponding equivalent square field and the maximal difference over 10 % was found. The difference was found larger for the smaller field with the same elongation ratio. The effect of the beam quality and the depth of measurement on the output difference was minimal. Conclusion: Based on the study, there is criteria for the application of the method for output calculation. For the combination of long axis and elongation ratio whose relationship satisfies Elongation ratio < (0.48) (Long axis) - 0.5, the equivalent-field method is valid for output calculation within 2 % for the field whose long axis < 25-cm. For other combinations, instead of using the equivalent-field method, direct output measurement is recommended. This criteria can be applied for 4-10 MV x-ray beams up to 10-cm depth.

  • PDF

INFLUENCES OF APICOECTOMY AND RETROGRADE CAVITY PREPARATION METHODS ON THE APICAL LEAKAGE (치근단절제 및 역충전와동 형성방법이 치근단누출에 미치는 영향)

  • Yang, Jeong-Ok;Kim, Sung-Kyo;Kwon, Tae-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.537-549
    • /
    • 1998
  • The purpose of this study was to evaluate the influence of root resection and retrograde cavity preparation methods on the apical leakage in endodontic surgery. To investigate the effect of various root resection and retrograde cavity preparation methods on the apical leakage, 71 roots of extracted human maxillary anterior teeth and 44 mesiobuccal roots of extracted human maxillary first molars were used. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. Three millimeters of each root was resected at a 45 degree angle or perpendicular to the long axis of the tooth according to the groups. Retrograde cavities were prepared with ultrasonic instruments or a slow-speed round bur, and occlusal access cavities were filled with zinc oxide eugenol cement. Three coats of clear nail polish were placed on the lateral and coronal surfaces of the specimens except the apical cut one millimeter. All the specimens were immerged in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using two-way ANOVA and Duncans Multiple Range Test. The results were as follows: 1. No statistically significant difference was observed between ultrasonic retrograde cavity preparation method and slow-speed round bur technique, without apical bevel (p>0.05). 2. Ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, with bevel (p<0.0001). 3. No statistically significant difference was found between beveled resected root surface and non-beveled resected root surface, with ultrasonic technique (p>0.05). 4. Non-beveled resected root surface showed significantly less apical leakage than beveled resected root surface, with slow-speed round bur technique (p<0.0001). 5. No statistically significant difference in apical leakage was found between the group of retrograde cavity prepared parallel to the long axis of the tooth and the group of one prepared perpendicular to the long axis of the tooth (p>0.05). 6. Regarding isthmus preparation, ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, in the mesiobuccal root of maxillary molar, without bevel (p<0.0001).

  • PDF

Evaluation of bonding state of tunnel shotcrete using impact-echo method - numerical analysis (충격 반향 기법을 이용한 숏크리트 배면 접착 상태 평가에 관한 수치해석적 연구)

  • Song, Ki-Il;Cho, Gye-Chun;Chang, Seok-Bue
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.2
    • /
    • pp.105-118
    • /
    • 2008
  • Shotcrete is one of the main support materials in tunnelling. Its bonding state on excavated rock surfaces controls the safety of the tunnel: De-bonding of shotcrete from an excavated surface decreases the safety of the tunnel. Meanwhile, the bonding state of shotcrete is affected by blasting during excavation at tunnel face as well as bench cut. Generally, the bonding state of shotcrete can be classified as void, de-bonded, or fully bonded. In this study, the state of the back-surface of shotcrete is investigated using impact-echo (IE) techniques. Numerical simulation of IE technique is performed with ABAQUS. Signals obtained from the IE simulations were analyzed at time, frequency, and time-frequency domains, respectively. Using an integrated active signal processing technique coupled with a Short-Time Fourier Transform (STFT) analysis, the bonding state of the shotcrete can be evaluated accurately. As the bonding state worsens, the amplitude of the first peak past the maximum amplitude in the time domain waveform and the maximum energy of the autospectral density are increasing. The resonance frequency becomes detectable and calculable and the contour in time-frequency domain has a long tail parallel to the time axis. Signal characteristics with respect to ground condition were obtained in case of fully bonded condition. As the ground condition worsens, the length of a long tail parallel to the time axis is lengthened and the contour is located in low frequency range under 10 kHz.

  • PDF

Finite element stress analysis according to the point and surface occlusal loads on the implant prosthesis (임플란트 보철물의 점하중과 면하중에 따른 유한요소법적 응력 분석)

  • Choi, Min-Ho;Kang, Jae-Suek;Boo, Soo-Bung;Oh, Snag-Ho;An, OK-Ju;Kang, Dong-Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.2
    • /
    • pp.83-94
    • /
    • 2004
  • The purpose of this study was to compare the distributing pattern of stress according to the types of occlusal load on the finite element models of the splinted implant prostheses. The finite element model was designed with the parallel placement of two fixtures ($4.0mm{\times}11.5mm$) on mandibular first and second molars. The cemented crowns for mandibular first and second molars were made. Three-dimensional finite element model was created with the components of the implant, surrounding bone and cemented crowns. Two types of occlusal load, the point load and the surface load within 0.5 mm radius circle, were applied to the finite element models with 200N magnitude in axial(along the long axis of the implant and oblique(angulation of $30^{\circ}$ to the long axis) directions perpendicular to cuspal incline. Loads were positioned from the center of central fossa and to distance of 2 mm and 4 mm apart from the center of central fossa. Von-Mises stresses were recorded and compared in the fixtures and sections. The results were as following : 1. Under axial loading at the central fossa, the stress was distributed along the fixture except for the apical portion, not relative to both point & surface contacts. 2. With offset distance increasing, the highest stresses were concentrated in the neck portion of the fixture. 3. The maximum von Mises stress under the oblique load was greater than that under the axial load. 4. Under the oblique load, the highest stress were concentrated in the buccal side and lingual neck portion of the fixture with offset distance increasing. The results had a tendency to increase the stress on the neck portion of fixture with the offset and oblique loads increasing. The design of occlusal scheme should be allowed to distribute stress axially in maximum intercuspation and to decrease the angulation of cuspal incline.

Studies on the Elasticity, Young Modulus, and Breaking Tension of the Tympanic Membrane in Dog (고막(鼓膜)의 탄성도(彈性度)와 파열장력(破裂張力)에 관(關)한 연구(硏究))

  • Lee, Young-Shik
    • The Korean Journal of Physiology
    • /
    • v.2 no.1
    • /
    • pp.39-45
    • /
    • 1968
  • Recently, in this department, pressure-displacement curve and breaking tension of dog and human tympanic membrane were studied using intact, fresh or dried tympanic membrane attached to external auditory meatus. However, physical property, proper elasticity-Young Modulus, of the tympanic membrane has not been clarified yet. Present study is attempted to further clarify proper Young Modulus of tympanic membrane, and to distinguish possible difference between layer of stratum radiatum and layer of stratum circulare of tympanic membrane in breaking tension and in Young Modulus. Tympanic membrane was excised from sacrificed dog, and preparation was made into the size of approximately 1 mm in width and 3 mm in length. In fresh or dried tympanic membrane, which was dried at $80^{\circ}C$ for 24 hrs., some preparations were made along the long axis parallel to the fibers of radial direction, and others were made along the long axis perpendicular to the radial fibers-circular direction. Breaking tension and displacement according to loading, were measured and Young Modulus was calculated in tympanic membrane preparations under the different experimental conditions. Results obtained are summarized as follows : 1. Young Modulus of fresh tympanic membrane in radial direction was $6.57{\times}10^8\;dyne/cm^2$, and that of fresh preparation in circular direction was $1.68{\times}10^8\;dyne/cm^2$. The Young Modulus of fresh tympanic membrane in radial direction resembles to that of silk and whale moustache. In dried tympanic membrane, Young Modulus of preparation of radial direction was $30.2{\times}10^8\;dyne/cm^2$ and that of preparation in circular direction was $25.0{\times}10^8\;dyne/cm^2$. 2. Breaking tension of fresh tympanic membrane was 44.9 gm/mm in radial preparation, and 7.9 gm/mm in circular preparation. In dried tympanic membrane, breaking tension was 46.7 gm/mm in preparation of radial direction, and 17.2 gm/mm in preparation of circular direction. 3. Much smaller breaking tension of the circular preparation-one fifth to the radial preparation-seemed to be responsible for the higher incidence of circular fiber breaking in tympanic membrane performation caused by trauma or sudden change in atmospheric pressure. 4. The correlation seemed to be very close between breaking tension and Young Modulus in tympanic membrane.

  • PDF