• 제목/요약/키워드: Locking

검색결과 993건 처리시간 0.023초

Seed 레이저용 정상분산 영역에서 발진하는 간단한 구조의 이터븀 기반 모드 잠금 광섬유 레이저 (A Simple Yb-Doped Mode-Locked Fiber Oscillator under Normal Dispersion as a Seed Laser)

  • 김병권;주기남
    • 한국정밀공학회지
    • /
    • 제31권9호
    • /
    • pp.805-811
    • /
    • 2014
  • In this investigation, we constructed and demonstrated a simple Yb-doped fiber laser, of which longitudinal modes are mode-locked without any additional devices to compensate the dispersion caused by optical components. Non-linear polarization rotation (NPR) was adopted for the mode-locking mechanism and a polarization controller (PC) was used for a kind of spectral filters to restrict the bandwidth for mode-locking. As the result, the laser was successfully operated as mode-locked with the repetition rate of 42.2 MHz and the spectrum was broadened up to approximately 16 nm at 1033 nm center wavelength when the laser was mode-locked. In this paper, the operation of the developed Yb-doped mode-locked laser is explained with the concept of Lyot filter realized by a PC, which enables mode-locking under normal dispersion. In the industrial applications, this laser can be used as a seed laser of the high power lasers for optical manufacturing.

전단건물을 이용한 와류발산현상 파악 (Investigation of the Vortex Shedding with the Shear Building)

  • 이상호
    • 한국산학기술학회논문지
    • /
    • 제11권5호
    • /
    • pp.1785-1790
    • /
    • 2010
  • 와류발산현상을 파악하기 위한 풍동과 2층 전단건물을 제작하였다. 풍동은 풍속이 24m/s까지 구현되도록 제작하였으며, 전단건물은 고유 진동수가 풍동에서 구현 할 수 있는 와류 진동수 범위에 속하도록 설계되었다. 원통형 실린더를 부착한 전단건물의 풍동실험을 수행하여 locking-on 현상에 의한 공명현상을 관찰하였다. 또한 관찰된 결과로부터 와류발산하중은 실린더의 진폭과 진동수의 영향이 작용하는 것을 파악하였다.

곁인대가 파열되고 주관절이 탈구된 개에서 이중 Locking-loop 봉합법의 치료효과 (Therapeutic Effect of a Double Locking-loop Suture Pattern on the Elbow Luxation with Rupture of Collateral Ligament in a Dog)

  • 이재영;김중현;김소섭;이승근;최석화
    • 한국임상수의학회지
    • /
    • 제21권4호
    • /
    • pp.406-408
    • /
    • 2004
  • A nine-month-old male Jindo with non weight-bearing on the right forelimb in flexed position, pain and edema of the elbow, and resist elbow extension was brought to the Veterinary Teaching Hospital, Chungbuk National University. Elbow radiographs showed loss of humeroradial joint space and lateral displacement of the radius and ulna. Closed reduction was reported the best therapy in most cases of luxation of the elbow but conservative reduction was impossible. Open reduction of the luxated elbow was performed and ruptured collateral ligaments were identified. Displaced elbow was required bloody surgical operation and gentle reduction to restore elbow joint. Internal reduction of choice for elbow luxation with rupture of collateral ligament in the dog was a double locking-loop suture pattern. To ensure secure grasping of parallel bundles of ligament fibers to transverse bites of each suture were placed superficial to the longitudinal bites. All ligaments were repaired with 3-metric (size 2 USP) monofilament polypropylene suture. No complications have been noted during a five-month follow up.

측파대 광 주입 락킹 기법을 이용한 밀리미터파 신호생성 및 실험적 분석 (Experimental Analyses and Millimeter Wave Signal Generation Using Sideband Injection Locking Method)

  • 김정태
    • 한국정보통신학회논문지
    • /
    • 제14권12호
    • /
    • pp.2769-2774
    • /
    • 2010
  • 본 논문에서는 밀리미터파 대역의 신호 발생을 위한 헤테로다인 방식인 sideband injection locking 방법을 제안하고 실험적으로 분석하였다. 향후, 무선 이동통신, 초고속 광대역 통신망 등에 사용되어질 밀리미터파 신호는 전기적 요소의 한계로 광학적인 요소에 의해 신호를 생성하는 방법이 많이 연구되고 있으며 광학적 기술에 기초한 소자기술 등이 발전되고 있다. 따라서 본 논문에서는 향후 밀리미터파 대역에서 사용되어질 LMDS(Local Multi-point Distribution Service) 등의 시스템에서 수십기가 헤르츠급의 광원으로 응용 가능한 헤테로다인 방식을 이용한 밀리미터파 대역의 신호생성에 대한 이론적 방법 및 실험적 고찰을 통하여 검증하였다.

Locking Time과 Jitter 특성의 개선을 위한 PLL 설계에 관한 연구 (A Study on the Design of PLL for Improving of Characteristics of Locking Time and Jitter)

  • 박재범;박윤식;김화영;성만영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1188-1191
    • /
    • 2003
  • In this paper, we focus our attention on the improvement of locking time and jitter parameter and propose the new structure of PLL which combined with the FVC, FOVI Matcher(FVC-Output and VCO-input Matching Circuit), Control Circuit and the conventional charge pump PLL. Using fast operation characteristics of the FVC, the circuit matching FVC-Output and VCO-input (FOVI Matcher) made to synchronize very fast. Fast locking time is usually required for application where the PLL has to settle rapidly if they switch from an idle mode to a normal mode and to track high-frequency data bit rate in data recovery systems. After a fast acqusition is achieved by the using the FVC, the conventional PLL operates for removing the phase error between the reference signal and the feedback signal. Therefore this structure can improve the trade-off between acquisition behavior and locked behavior.

  • PDF

연동도표 작성 및 검토 자동화 프로그램 (Automation Program for Drawing and Examination of Locking Sheet)

  • 장승호;유근수;한창우;이영수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1285-1293
    • /
    • 2008
  • Locking sheet is to display the contents of interlocking equipment for safe train drive in stations. It is being used as a basic information for interlocking equipment and for route control condition and the discussion for train operation between related parties. In spite of importance of this, there was no other way except depending on the work by hands from each stage(drawing, examination, discussion, approval) due to non-existing any tool. It is written it takes 30days from drawing to approval by procedures. However, it is required over the days in real time due to argument of each party. Furthermore on drawing of locking sheet, special conditions applied in accordance with situations of each station occasionally are different depending on the person in charge. Therefore, it is urgent to make up Logic Tree to accept special conditions of all stations. Automation Program for Drawing and Examination of Locking Sheet is to improve inefficient interlocking operation which was operated by hands in accordance with custom as automated system. The target of this program is to minimize the processing time and potential errors by personal work and set up standards for Logic Tree of special condition.

  • PDF

A Wide-range Tunable Wavelength-stabilization Technique for Semiconductor Lasers

  • Chen, Han;Qiao, Qinliang;Min, Jing;He, Cong;Zhang, Yuanyuan
    • Current Optics and Photonics
    • /
    • 제5권4호
    • /
    • pp.384-390
    • /
    • 2021
  • This paper presents a wide-range tunable wavelength-locking technology based on optoelectronic oscillation (OEO) loops for optical fiber sensors and microwave photonics applications, explains the theoretical fundamentals of the design, and demonstrates a method for locking the relative wavelength differences between a leader semiconductor laser and its follower lasers. The input of the OEO loop in the proposed scheme (the relative wavelength difference) determines the radio-frequency (RF) signal frequency of the oscillation output, which is quantized into an injection current signal for feedback to control the wavelength drift of follower lasers so that they follow the wavelength change of the leader laser. The results from a 10-hour continuous experiment in a field environment show that the wavelength-locking accuracy reached ±0.38 GHz with an Allan deviation of 6.1 pm over 2 hours, and the wavelength jitter between the leader and follower lasers was suppressed within 0.01 nm, even though the test equipment was not isolated from vibrations and the temperature was not controlled. Moreover, the tunable range of wavelength locking was maintained from 10 to 17 nm for nonideal electrical devices with limited bandwidth.

선박용조타기의 Hydraulic Locking Alarm용 Hall Effect Sensor 개발에 관한 연구 (A Study on the Development of Hall Effect Sensor for Hydraulic Locking Alarm in Ship's Steering Gear)

  • 이정민;정원지;임동재;최경신
    • 한국기계가공학회지
    • /
    • 제18권1호
    • /
    • pp.116-121
    • /
    • 2019
  • The LVDT (Linear Variable Displacement Transducer) type sensor used for the existing ship's steering gear is simple on / off that does not perform proportional control operation to the control & unloading device. When the main spool is located at both extremes, It is reflected in the price by using an expensive sensor for import. In this paper, the Hall Effect Sensor is applied to Hydraulic Locking Alarm to analyze classification rules, structure, characteristics and operation principle of valves, and research on localization development in terms of cost reduction. The comparative analysis of the existing prototypes and the cause analysis of the problems were carried out, and the structural analysis showed satisfactory results within the allowable stress range. In addition, it was verified through experiments that the actual operation is realized by applying the actual developed product, and it was confirmed that the load on the maximum value exceeds the allowable maximum load even in the case of the universal tensile test in preparation for the departure of the rod casing.

Anatomical Locking Plate with Additional K-wire Fixation for Distal Clavicle Fracture

  • Nam, Woo-Dong;Moon, Sung-Hoon;Choi, Ki-Yong
    • Clinics in Shoulder and Elbow
    • /
    • 제20권4호
    • /
    • pp.230-235
    • /
    • 2017
  • Background: Neer type II distal clavicle fractures have the drawback of coracoclavicular instability and insufficient distal bony fragment, thereby making it difficult to achieve adequate fixation. Although various surgical treatments have been described for Neer type II fracture, the optimal treatment remains controversial. This study reports the clinical results and usefulness of anatomical locking plate with additional K-wire fixation. Methods: A totally of 21 patients with type II distal clavicle fracture were included in the study. The surgical procedure reduced the fracture temporarily; it included insertion of one or two K-wire from the lateral margin of the distal fragment to the proximal fragment through the fracture site, followed by application and fixation of the locking plate. The bony union and migration of K-wire was evaluated in the follow-up radiography. The coracoclavicular distance and acromioclavicular joint arthrosis were assessed at the final follow-up. The Constant Score (CS) and Korean Shoulder Score (KSS) were evaluated for clinical scoring. Results: Bone union was achieved in all cases. At the final follow-up, coracoclavicular distance of the injured shoulder was increased, as compared to the intact shoulder (p=0.002), with no accompanying clinical symptoms. No K-wire migration was observed. At the final follow-up, K-wire irritation was observed in two cases and acromioclavicular arthrosis in one case, with no other adverse effects. Pain visual analogue scale, CS, and KSS were improved in all cases. Conclusions: The method of anatomical locking plate with additional K-wire fixation could be useful in achieving beneficial clinical results.

Internal Fixation with a Locking T-Plate for Proximal Humeral Fractures in Patients Aged 65 Years and Older

  • Yum, Jae-Kwang;Seong, Min-Kyu;Hong, Chi-Woon
    • Clinics in Shoulder and Elbow
    • /
    • 제20권4호
    • /
    • pp.217-221
    • /
    • 2017
  • Background: The purpose of this study was to evaluate the clinical and radiographic outcomes of internal fixation with locking T-plates for osteoporotic fractures of the proximal humerus in patients aged 65 years and older. Methods: From January 2007 through to December 2015, we recruited 47 patients aged 65 years and older with osteoporotic fractures of the proximal humerus. All fractures had been treated using open reduction and internal fixation with a locking T-plate. We classified the fractures in accordance to the Neer classification system; At the final follow-up, the indicators of clinical outcome-the range of motion of the shoulder (flexion, internal rotation, and external rotation) and the presence of postoperative complications-and the indicators of radiographic outcome-the time-to-union and the neck-shaft angle of the proximal humerus-were evaluated. The Paavolainen method was used to grade the level of radiological outcome in the patients. Results: The mean flexion was $155.0^{\circ}$ (range, $90^{\circ}-180^{\circ}$), the mean internal rotation was T8 (range, T6-L2), and the mean external rotation was $66.8^{\circ}$ (range, $30^{\circ}-80^{\circ}$). Postoperative complications, such as plate impingement, screw loosening, and varus malunion were observed in five patient. We found that all patients achieved bone union, and the mean time-to-union was 13.5 weeks of the treatment. The mean neck-shaft angle was $131.4^{\circ}$ at the 6-month follow-up. According to the Paavolainen method, "good" and "fair" radiographic results each accounted for 38 and 9 of the total patients, respectively. Conclusions: We concluded that locking T-plate fixation leads to satisfactory clinical and radiological outcomes in elderly patients with proximal humeral fractures by providing a larger surface area of contact with the fracture and a more rigid fixation.