• Title/Summary/Keyword: Location analysis

Search Result 7,059, Processing Time 0.032 seconds

A Study on Combustion Characteristics of Synthetic Gas Air Lifted Premixed Flames with High Strain Rate in an Impinging Jet Combustion Field (합성가스의 충돌제트 연소장에서 고신장율 부상 예혼합화염 연소 특성 연구)

  • Kang, Ki-Joong;Park, Tae-Joon;Hwang, Cheol-Hong;Lee, Kee-Man
    • Journal of the Korean Society of Combustion
    • /
    • v.16 no.4
    • /
    • pp.31-37
    • /
    • 2011
  • This paper presents both experimental and numerical investigation of the combustion characteristics of stretched premixed lift-off flames using synthetic gas($H_2$/CO) in an impinging burner. We used "Spin code" for numerical analysis. An ICCD camera was employed to measure flame location and flame thickness. The impinging surface temperature was affected by local strain rate K, equivalence ratio, and composition ratio of fuel. In spite of the difference of boundary conditions in experimental and numerical results, the tendencies of surface temperatures were agreed. From result of this work, we also found that flame location and flame thickness directly related to surface temperature are greatly affected by local strain rate K.

A Study to investigate architectural environment caused by the location of an Elementary school - On the basis of district of building site development in Busan city - (초등학교(初等學敎) 입지(立地)에 따른 건축적(建築的) 환경(環境) 조사연구(調査硏究) - 부산시내 택지개발지구를 중심으로 -)

  • Shon, Yoon-Deuk;Lyou, Jong-Woo
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.12 no.1
    • /
    • pp.41-53
    • /
    • 2005
  • The purpose of this study is to suggest the reference materials in the selection of location of elementary school at the planning of building site development by analyzing the environment of architecture in the district of building site development. The method of investigation adapted the site investigation and drawing analysis of the elementary school, after collecting materials of the district of building site development within Busan city, under the object of investigation including 17 elementary schools within 15 districts of building site development and the object of investigation.

Assessment of Lightning Arrester Location in Combined Transmission Line Connected whth Overhead Line and Underground Cable (가공송전선로와 지중송전선로가 연계된 혼합송전선로에서 피뢰기 적정위치 검토 및 평가)

  • Ha, Che-Wung;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.443-445
    • /
    • 2000
  • This paper describes the assessment of proper location of lightning arrester in combined transmission line which is connected with overhead line and underground cable. The modeling for simulation is established using the actual system in ATP Draw and EMTP. Simulation is carried out to find out the best point to install the arrester in given the model system. And also voltage and current is analyzed on cable covering protection unit(CCPU). The simulation result demonstrated the best location of arrester in the given transmission line through the detailed analysis and its assessment.

  • PDF

Contractor Characteristics, Relationships with Wholesalers, and Wholesalers' Satisfaction (위탁생산업체의 특성, 위탁생산업체-도매업체 관계 형성 및 도매업체 만족도에 관한 연구)

  • Seo, Min-Jeong;Lee, Kyu-Hye
    • The Research Journal of the Costume Culture
    • /
    • v.18 no.3
    • /
    • pp.588-598
    • /
    • 2010
  • Purposes of this research were to examine characteristics of contractors and the relationship between contractors and wholesalers of apparel products. Influence of such variables on wholesalers' satisfaction was also assessed. Location, reputation and service were factors of contractor characteristics. Dependence, cooperation and power were three factors that were considered for contractor-wholesaler relationship variable. Survey data from 109 wholesalers located in Dongdaemun Fashion Town in Korea was used for analysis. Empirical results confirmed the importance of service factor of contractor characteristics. Service and location of the contractor had positive influence on cooperation. Location had negative influence on power. Reputation had positive direct influence on wholesaler satisfaction. Cooperation between contractors and wholesalers had significant influence on wholesaler satisfaction.

Confirmation Method of Target Detection for Vehicle Mounted Metal Detector

  • Jung, Byung-Min;Shin, Beom-Su;Chang, YuShin;Yang, DongWon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.10
    • /
    • pp.49-54
    • /
    • 2016
  • In this paper, the confirmation method of target detection for the vehicle mounted metal detector (MD) has been described. The vehicle mounted MD with the arrayed 6 coils to detect the width of 2.4 m was demonstrated. It is important and necessary to inform the location of the objects detected by the MD. The confirmation method of target detection was verified by using the MD GUI and the analysis of the receive signal processing. The receive signal processing is performed by comparing the threshold and the difference of the signal calibrated at initial location and the signal detected at present location.

Consistency preservation techniques for Location Register System in Mobile Networks

  • Kim, Jang-Hwan
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.144-149
    • /
    • 2020
  • A database called Home Location Register(HLR) plays a major role in location management in mobile cellular networks. The objectives of this paper are to identify the problems of the current HLR system through rigorous analysis, to suggest solutions to them. The current HLR backup method is a process of simply writing the changed memory SLD block to disk, which has a problem in maintaining database consistency. Since information change and backup are performed separately by separate processes, there is a risk of information inconsistency when an error restart occurs. To solve this problem, a transaction concept was introduced for subscriber-related operation functions and a recovery method through logging and checkpointing was introduced. The subscriber related functions of tasks terminated normally by the suggested process are recovered with consistency even after system restarts. Performance is also not affected seriously because disk tasks for log occur with only subscriber related functions.

Two Terminals Numerical Algorithm for Distance Protection, Fault Location and Acing Faults Recognition Based on Synchronized Phasors

  • Lee Chan-Joo;Park Jong-Bae;Shin Joong-Rin;Radojevic Zoran
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.35-41
    • /
    • 2006
  • This paper presents a new numerical algorithm for fault location estimation and for faults recognition based on the synchronized phasors. The proposed algorithm is based on the synchronized phasor measured from the synchronized PMUs installed at two-terminals of the transmission lines. In order to discriminate the fault type, the arc voltage wave shape is modeled numerically on the basis of a great number of arc voltage records obtained by transient recorder. From the calculated arc voltage amplitude it can make a decision whether the fault is permanent or transient. The results of the proposed algorithm testing through computer simulation are given.

Modeling and Analysis of Queuing Effect of Two-Level Approach to Network Localization

  • Park, Byungsung;Yoo, Jaeyeong;Kim, Hagbae
    • ETRI Journal
    • /
    • v.34 no.4
    • /
    • pp.625-628
    • /
    • 2012
  • In this letter, a novel method for localizing a user in a smart home environment is presented. We propose a two-level structure, in which the first level determines an occupant's location in the block level using RSSI in a ZigBee network, while the second level accurately estimates the occupant's location using a particle filter to handle the variations in the signal strength measurement. We devise an experimental setup with people performing significant tasks in the smart home. The results obtained from the testbed indicate that the proposed model leads to an improvement in the mean distance error.

Optimization of Pin-hole Location to Minimize Stress Concenstration around Hole in Rotating Disc under Centrifugal Force (원심력을 받는 회전원판내 원공주위 응력집중 최소화를 위한 핀홀위치 최적화)

  • Han, Geun-Jo;Kim, Tae-Hyong;Ahn, Sung-Chan;Shim, Jae-Joon;Han, Dong-Seop
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.574-578
    • /
    • 2003
  • The objective of this paper is to decide optimal location of pin-hole to minimize stress concenstation around hole in rotating disc. The focus of this investigation is to evaluate the effect of pin-hole for stress distribution around hole using optimum design technic and finite element analysis. Design variables are radial and angular location of pin-hole from center of hole, objective function is maximum stress around hole in rotating disc. We use first order method of optimization technic.

  • PDF

A Study on the Prediction of Combustion Gas Behavior Induced by Fire in a Building (건물내 화재에 의한 연소가스 거동 예측에 관한 연구)

  • Pak, H.Y.;Park, K.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.267-281
    • /
    • 1994
  • The Combustion gas behavior induced by fire in a building is numerically investigated. The typical building for this analysis is partially divided by a vertical baffle projecting from the ceiling. The solution procedure includes the low Reynolds number ${\kappa}-{\varepsilon}$ model for the turbulent flow and the discrete ordinates method is used for the calculation of radiative heat transfer equation. The effects of the location and size of fire source and baffle length on velocity and temperature distributions, species mass fraction and flame location are analyzed. As the results of this study, it is found that the case when the fire source is located at the vertical wall is more dangerous than at the bottom wall in view of the combustion products and flame location. It is also found that the radiation effect cannot be neglected in analyzing the building in fire.

  • PDF