• Title/Summary/Keyword: Local volume fraction

Search Result 74, Processing Time 0.023 seconds

Local nanofiller volume concentration effect on elastic properties of polymer nanocomposites

  • Shin, Hyunseong;Han, Jin-Gyu;Chang, Seongmin;Cho, Maenghyo
    • Multiscale and Multiphysics Mechanics
    • /
    • v.1 no.1
    • /
    • pp.65-76
    • /
    • 2016
  • In this study, an influence of local variation of nanoparticulate volume fraction on the homogenized elastic properties is investigated. It is well known that interface effect is dependent on the radius and volume fraction of reinforced nanofillers. However, there is no study on the multiscale modeling and analysis of polymer nanocomposites including polydispersed nanoparticles with consideration of interphase zone, which is dependent on the volume fraction of corresponding nanoparticles. As results of numerical examples, it is confirmed that an influence of local variation of nanoparticulate volume fraction should be considered for non-dilute system such as cluster of nanoparticles. Therefore representative volume element analysis is conducted by considering local variation of nanoparticle volume fraction in order to analyze the practical size of cell including hundreds of nanoparticles. It is expected that this study could be extended to the multiparticulate nanocomposite systems including polydispersed nanoparticles.

MHD Boundary Layer Flow and Heat Transfer of Rotating Dusty Nanofluid over a Stretching Surface

  • Manghat, Radhika;Siddabasappa, Siddabasappa
    • Kyungpook Mathematical Journal
    • /
    • v.60 no.4
    • /
    • pp.853-867
    • /
    • 2020
  • The aim of this study was to analyze the momentum and heat transfer of a rotating nanofluid with conducting spherical dust particles. The fluid flows over a stretching surface under the influence of an external magnetic field. By applying similarity transformations, the governing partial differential equations were trans-formed into nonlinear coupled ordinary differential equations. These equations were solved with the built-in function bvp4c in MATLAB. Moreover, the effects of the rotation parameter ω, magnetic field parameter M, mass concentration of the dust particles α, and volume fraction of the nano particles 𝜙, on the velocity and temperature profiles of the fluid and dust particles were considered. The results agree well with those in published papers. According to the result the hikes in the rotation parameter ω decrease the local Nusselt number, and the increasing volume fraction of the nano particles 𝜙 increases the local Nusselt number. Moreover the friction factor along the x and y axes increases with increasing volume fraction of the nano particles 𝜙.

Study on the Shape of Free Surface Waves by the Scheme of Volume Fraction (Volume Fraction 기법에 의한 자유표면파 형상 연구)

  • Kwag, Seung-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1215-1220
    • /
    • 2008
  • To obtain the shape of the free surface more accurately, computations are carried out by a finite volume method using unstructured meshes and an interface capturing method. Free-surface flow, which is very important in the fields of ship and marine engineering, is numerically simulated for flows of both water and air. Control volumes are used with an arbitrary number of faces and allows a local mesh refinement. The integration is of second order, with a midpoint rule integration and linear interpolation. The method is fully implicit and uses quadratic interpolation. The solution method of pressure-correction type solves sequentially equations of momentum, continuity, conservation, and two-equations turbulence model. Comparison are quantitatively made between the computation and experiment in order to confirm the solution method.

Tomographic Reconstruction of Asymmetric Soot Structure from Multi-angular Scanning (다각 주사법을 이용한 비대칭 매연분포의 재구성)

  • Lee, Sang-Min;Hwang, Jun-Young;Chung, Suk-Ho
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.3
    • /
    • pp.24-30
    • /
    • 2003
  • A convolution algorithm combined with Fourier transformation has been applied to the tomographic reconstruction of asymmetric soot structure to identify the local soot volume fraction distribution. Line-of-sight integrated data from light extinction measurement with multi-angular scanning formed basic information for the deconvolution. Multi-peak following interpolation technique was applied to obtain the effect of increasing number of scanning angles. Height-by-height reconstructed soot volume fraction distribution was compared with laser-induced incandescence signals.

  • PDF

Experimental study on hydrogen behavior and possible risk with different injection conditions in local compartment

  • Liu, Hanchen;Tong, Lili;Cao, Xuewu
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1650-1660
    • /
    • 2020
  • Comparing with the large containment, the gas can not flow freely within the local compartment due to the small volume of the compartment in case of serious accident, which affects the hydrogen flow distribution, and it will determines the location where high concentration occurs in compartment. In this paper, hydrogen distribution and possible hydrogen risk in the vessel under the different conditions are investigated. The results show that when the initial gas momentum is increased, the ability of gas enters into the upper region of the vessel will be strengthened, and the hydrogen volume fraction in the upper region of the vessel is higher. Comparing with horizontal source direction, when source direction is vertically towards upper space, hydrogen is more likely to accumulate in the upper region of the vessel. With the increasing of steam mass flow, the dilution effect of steam on the hydrogen volume fraction will be strengthened, while the pressure in the vessel is also increased. When steam flow is decreased, the hydrogen explosion risk is higher in the vessel. The experiment data can provide technical support for the validation of the CFD software and the mitigation of hydrogen risk in the containment compartment.

Effect of Fiber Volume Fraction on the Stress Intensity Factors for Multi Layered Composites Under Arbitrary Anti-Plane Shear Loading

  • Kim, Sung-Ho;Lee, Kang-Yong;Joo, Sung-Chul
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.9
    • /
    • pp.920-927
    • /
    • 2000
  • A multi-layered orthotropic material with a center crack is subjected to an anti-plane shear loading. The problem is formulated as a mixed boundary value problem by using the Fourier integral transform method. This gives a Fredholm integral equation of the second kind. The integral equation is solved numerically and anti-plane shear stress intensity factors are analyzed in terms of the material orthotropy for each layer, number of layers, crack length to layer thickness and the order of the loading polynomial. Also, the case of monolithic and hybrid composites are investigated in terms of the local fiber volume fraction and the global fiber volume fraction.

  • PDF

A Study on the Characteristics of Two-Phase Flow by Driven Bubbles (기포운동에 따른 2상유동 특성에 관한 연구)

  • 서동표;오율권
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.268-273
    • /
    • 2003
  • In the present study, the characteristics of upward bubble flow were experimentally investigated in a liquid bath. An electro-conductivity probe was used to measure local volume fraction and bubble frequency. Since the gas is concentrated at the near nozzle, the flow parameters are high near the nozzle. In general their axial and radial values tended to decrease with increasing distance. For visualization of flow characteristics, a Particle Image Velocimetry (P.I..V) and a thermo-vision camera were used in the present study. The experimental results show that heat transfer from bubble surface to water is largely completed within z=10mm from the nozzle, and then the temperature of bubble surface reaches that of water rapidly. Due to the centrifugal force, the flow was more developed near the wall than at bubble-water plume. Vortex flow in the bottom region was relatively weaker than that in the upper region.

A Study on the Characteristics of Two-Phase Flow by Driven Bubbles in a Liquid Bath

  • Oh, Yool-Kwon;Seo, Dong-Pyo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.1
    • /
    • pp.44-50
    • /
    • 2005
  • In the present study, the characteristics of upward bubble flow were experimentally investigated in a liquid bath. An electro-conductivity probe was used to measure local volume fraction and bubble frequency. Since the gas was concentrated at the near the nozzle, the flow parameters were high near the nozzle. In general their axial and radial values tended to decrease with increasing distance. For visualization of flow characteristics, a Particle Image Velocimetry (PIV) and a thermo-vision camera were used in the present study. The experimental results showed that heat transfer from bubble surface to water was largely completed within z = 10 mm from the nozzle, and then the temperature of bubble surface reached that of water rapidly. Due to the centrifugal force, the flow was more developed near the wall than at bubble-water plume. Vortex flow in the bottom region was relatively weaker than that in the upper region.

THE ENVIRONMENTAL DEPENDENCE OF THE FRACTION OF 'UNCONVENTIONAL' GALAXIES: FAINT RED AND LUMINOUS BLUE

  • Deng, Xin-Fa;Zhang, Fuyang;Song, Jun;Chen, Yi-Qing;Jiang, Peng
    • Journal of The Korean Astronomical Society
    • /
    • v.45 no.3
    • /
    • pp.59-64
    • /
    • 2012
  • Using the volume-limited Main galaxy sample constructed from the Sloan Digital Sky Survey Data Release 7 (SDSS DR7), we explore the environmental dependence of the fraction of 'unconventional' galaxies: luminous blue and faint red. It is found that the fraction of faint red increases apparently with increasing local density, and the fraction of luminous blue declines substantially with increasing local density, which shows that there is an environmental dependence for color beyond that for luminosity.

Helical tomotherapy for spine oligometastases from gastrointestinal malignancies

  • Choi, Yun-Seon;Kim, Jun-Won;Lee, Ik-Jae;Han, Hee-Ji;Baek, Jong-Geal;Seong, Jin-Sil
    • Radiation Oncology Journal
    • /
    • v.29 no.4
    • /
    • pp.219-227
    • /
    • 2011
  • Purpose: This study evaluated the treatment effectiveness and proper radiation dose of helical tomotherapy (HT) in spine oligometastases from gastrointestinal cancers. Materials and Methods: From 2006 to 2010, 20 gastrointestinal cancer patients were treated with HT for spine oligometastases (31 spine lesions). The gross tumor volume (GTV) was the tumor evident from magnetic resonance imaging images fused with simulation computed tomography images. Clinical target volume (CTV) encompassed involved vertebral bodies or dorsal elements. We assumed that the planning target volume was equal to the CTV. We assessed local control rate after HT for 31 spine metastases. Pain response was scored by using a numeric pain intensity scale (NPIS, from 0 to 10). Results: Spine metastatic lesions were treated with median dose of 40 Gy (range, 24 to 51 Gy) and median 5 Gy per fraction (range, 2.5 to 8 Gy) to GTV with median 8 fractions (range, 3 to 20 fraction). Median biologically equivalent dose (BED, ${\alpha}/{\beta}$ = 10 Gy) was 52 $Gy_{10}$ (range, 37.5 to 76.8 $Gy_{10}$) to GTV. Six month local control rate for spine metastasis was 90.3%. Overall infield failure rate was 15% and outfield failure rate was 75%. Most patients showed pain relief after HT (93.8%). Median local recurrence free survival was 3 months. BED over 57 $Gy_{10}$ and oligometastases were identified as prognostic factors associated with improved local progression free survival (p = 0.012, P = 0.041). Conclusion: HT was capable of delivering higher BED to metastatic lesions in close proximity of the spinal cord. Spine metastases from gastrointestinal tumors were sensitive to high dose radiation, and BED (${\alpha}/{\beta}$ = 10 Gy) higher than 57 $Gy_{10}$ could improve local control.