• Title/Summary/Keyword: Local fire

Search Result 353, Processing Time 0.022 seconds

A Study on the Cause Analysis and Countermeasures of the Traditional Market for Fires in the TRIZ Method (TRIZ 기법에 의한 재래시장 화재의 원인분석과 대책에 관한 연구)

  • Seo, Yong-Goo;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.95-102
    • /
    • 2017
  • The fires in the traditional markets often occur recently with the most of them expanded into great fires so that the damage is very serious. The status of traditional markets handling the distribution for ordinary people is greatly shrunk with the aggressive marketing of the local large companies and the foreign large distribution companies after the overall opening of the local distribution market. Most of the traditional markets have the history and tradition from decades to centuries and have grown steadily with the joys and sorrows of ordinary people and the development of the local economy. The fire developing to the large fire has the characteristics of the problem that the fire possibility is high since all products can be flammable due to the deterioration of facilities, the arbitrary modification of equipment, and the crowding of the goods for sale. Furthermore, most of the stores are petty with their small sizes so that the passage is narrow affecting the passage of pedestrians. Accordingly, the traditional markets are vulnerable to fire due to the initial unplanned structural problem so that the large scale fire damage occurs. The study is concerned with systematically classifying and analyzing the result by applying the TRIZ tool to the fire risk factors to extract the fundamental problem with the fire of the traditional market and make the active response. The study was done for preventing the fire on the basis of it and the expansion to the large fire in case of fire to prepare the specific measure to minimize the fire damage. On the basis of the fire expansion risk factor of the derived traditional market, the study presented the passive measures such as the improvement of the fire resisting capacity, the fire safety island, etc. and the active and institutional measures such as the obligation of the fire breaking news facilities, the application of the extra-high pressure pump system, the divided use of the electric line, etc.

A Study on Development of Assessment Criteria for Safety City of Fire Fighting Area (소방방재분야의 안전도시 평가기준 개발에 관한 연구)

  • Choi, Kyu-Chool
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.218-228
    • /
    • 2009
  • The basic law about disaster and safety management and the fire fighting law state that the central government and the local governments are responsible for protecting the life and assets of the people. The well-fare developed nations have developed and are implementing diverse safety programs with making safe cities as their prime objective. Our nation has not yet practiced such actions. However, it is in demand to evaluate what safety policies are practiced by local governments for the people and to inform the people of those. Therefore, this research developed and suggests the assessment criteria and the assessment method to evaluate the safety level of a city by assessing the safety of buildings and facilities.

  • PDF

Simplified robustness assessment of steel framed structures under fire-induced column failure

  • Jiang, Binhui;Li, Guo-Qiang;Yam, Michael C.H.
    • Steel and Composite Structures
    • /
    • v.35 no.2
    • /
    • pp.199-213
    • /
    • 2020
  • This paper proposes a Global-Local Analysis Method (GLAM) to assess the progressive collapse of steel framed structures under fire-induced column failure. GLAM obtains the overall structural response by combining dynamic analysis of the heated column (local) with static analysis of the overall structure (global). Test results of two steel frames which explicitly consider the dynamic effect during fire-induced column failure were employed to validate the proposed GLAM. Results show that GLAM gives reasonable predictions to the test frames in terms of both whether to collapse and the displacement verse temperature curves. Besides, several case studies of a two-dimensional (2D) steel frame and a three-dimensional (3D) steel frame with concrete slabs were conducted by using GLAM. Results show that GLAM gives the same collapse predictions to the studied cases with nonlinear dynamic analysis of the whole structure model. Compared with nonlinear dynamic analysis of the whole structure model, GLAM saves approximately 70% and 99% CPU time for the cases of 2D and 3D steel frame, respectively. Results also show that the load level of a structure has notable effects on the restraint condition of a heated column in the structure.

Study on Fire Performance of Stud Connectors (스터드커넥터의 내화성능에 관한 연구)

  • Kim, Sung-Bae;Han, Sang-Hoon;Choi, Seng-Kwan
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.59-66
    • /
    • 2009
  • This research aims to conduct a pilot study for the in-fire performance of headed studs, commonly used in composite structures over the world. The robustness of the shear studs in fire appears to be a key element to govern the composite behaviour after a sudden local instability developed in structures such as trusses and cellular beams. In order to experimentally evaluate the residual strength of studs in fire, the standard push-out test was modified for a half of the original set-up to be equipped with a furnace. The adjustments allow the steel section to have a 3-sided exposure against fire. Under the Standard ISO fire, the modified push-out tests under loading were conducted to identify the failure mechanism of the studs in relation to temperature developments.

Optimization for Ventilation Capacity of Large Enclosure Considering Fire Load (화재하중을 고려한 대공간 제배연 용량 최적화 연구)

  • Ahn, Chan-Sol;Kim, A-Ram
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.478-481
    • /
    • 2011
  • This study is intended to evaluate and optimize the characteristics of smoke spreading and the appropriateness of evacuation time extended by operation of smoke control system during fire within the underground space of the building structured in compliance with the smoke control system performance criteria from the local fire safety standard, which has been currently applied to the buildings in Korea. Using the heat release per unit weight of the combustibles, a numerical analysis both in case of smoke control system in operation and the system not in operation was carried out at the several different shopping malls. From the viewpoint of securing the evacuation time, the results were compared in an attempt to assess the appropriateness of the fire safety criteria.

  • PDF

A Numerical Study on the Extinguishing Effects of CO2 in Counterflow Diffusion Flames with the Concept of Local Application System (국소방출방식 개념의 대향류 확산화염에서 CO2 소화효과에 관한 수치해석 연구)

  • Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong;Oh, Chang-Bo
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.55-62
    • /
    • 2012
  • The suppression mechanisms of carbon dioxide ($CO_2$) as a representative fire suppression agent were revisited using a counterflow diffusion flame which could be applied the concept of a local application system. To end this, the low strain rate $CH_4$/air counterflow diffusions with $CO_2$ addition in either fuel or oxidizer stream were examined numerically using detailed-kinetic chemistry. Radiative heat loss due to radiating gas species including $CO_2$ added was considered by the optically thin model (OTM). As a result, the critical $CO_2$ volume fractions in the oxidizer stream required to extinguish the flame were in good agreement with the experimental data reported in the literature, while somewhat under-prediction was observed with $CO_2$ added in the fuel stream. The surrogate agents were adopted to estimate the quantitative contribution with changing in global strain rate ($a_g$) on the flame extinguishment among pure dilution effect, thermal effects including radiation heat loss and chemical effect due to the $CO_2$ fire suppression agent.

A Study on the Improvement Plan of Domestic Fire Industry (국내 소방산업 육성방안에 관한 연구)

  • Shin, Mi-Young;Kim, Jung-Sook;Jung, Do-Young
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.60-70
    • /
    • 2011
  • Due to the city concentrated symptoms, high-rise building symptoms and diversity, the scale of fire disaster is increasing. So the economic expectation of fire disaster industry is growing. The domestic fire industry has an inadequate system, and hasn't a methodical system to foster the industry. And also most of the fire industry company are small and poor scale. So they haven't enough infrastructure like technical skill, manpower, marketing and so on. In order to drive fire industry from local fire protection industry to knowledge service, in this study, the items of human resources fostering, infrastructure and R&D were set and analyzed as detailed growth analysis factors. Also, the improvement plans were suggested and compared with IT industry which is defined as core industry in the 21st century knowledge-based economy in Korea.

Analyzing Safety Factors of Swimming Pool

  • KWON, Yeon Taek;SEO, Myung Seok;SEO, Won Jae
    • Journal of Sport and Applied Science
    • /
    • v.5 no.1
    • /
    • pp.11-15
    • /
    • 2021
  • Purpose: Swimming industry is improving faster than the other types of sport industries and populations of participating swimming are promptly increasing. Lack of recognition of fire safety in swimming facilities is issues related-studies has only recently begun to pay attention. This study is to review and extract fire safety factors for managing swimming pool. Research design, data, and methodology: The study reviewed related-ordinances, governmental documents, and studies discussing safety management of sport facility. Given the literature review, the study produced an initial construct presenting items and factors including fire safety elements and experts' review were conducted to ensure conceptual validity. Finally, the study generated the final factors and subitems representing fire safety elements for swimming pool management. Results: The study confirms factors and elements as follows: the study identifies fire safety equipments as first factors presenting fire extinguisher' place, its proper run, check list and so forth, Second factor is warning system including fire warning equipment, its proper operation, sprinkler and its proper operation, switch and lamp of emergency panel and their proper run and so on. Third factor is evacuation system including a fire exit, exit sign, broadcasting equipment, and their proper operation, and so on. The other factors are an electronic equipment and its subelements, gas management including safety management of LPG, gas valve, pipe, and fire prevention facility including a fire door and its proper operating. Conclusions: Regarding safety management of swimming pool, further discussions and implications were made, and future directions for related-studies were discussed.

A Study on the Fire Organization of the Effectiveness Life Safety Services (소방조직의 효과적인 생활안전서비스에 관한 연구)

  • Chae, Jin;Woo, Seong-Cheon;Go, Gi-Bong
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.47-55
    • /
    • 2013
  • The importance of fire safety services has increased expanding its services into prevention of danger and the reinforcement of safety services. The purpose of this study is to suggest a way for effective safety service by surveying fire fighters and residents of Gyeonggi Province and examining theories of safety services and actual status of 119 safety units. This study suggests the use of social capital by local community, establishment of cooperation between organizations, supports by citizens, cooperative activities by organizations, difference between emergency report and non emergency report and social safety net role of safety fire services.