• 제목/요약/키워드: Local earthquake

검색결과 359건 처리시간 0.025초

동일본대지진 시 공급된 프리패브건축협회 및 종합건설사의 응급가설주택 특성에 관한 연구 - 이시노마키시(石巻市) 카이세이(開成)단지 및 오하시(大橋)단지를 중심으로 - (A Study of the Characteristics of Emergency Housing from Japan Prefabricated Construction Suppliers and Manufacturers Association and General Construction Companies Provided during the Great East Japan Earthquake - focusing on the Kaisei and Ohashi Complexes of Ishinomaki City -)

  • 이상희;김봉애
    • 대한건축학회논문집:계획계
    • /
    • 제36권4호
    • /
    • pp.61-70
    • /
    • 2020
  • The purpose of this study is to provide data for planning future temporary housing in Korea by comparing and analyzing the characteristics of emergency housing rapidly supplied by Japan Prefabricated Construction Suppliers and Manufacturers Association(JPA) and general construction companies, according to the supply subject in times of natural disasters in Japan. Literature reviews and on-site field investigations are conducted as research methods during the period of August 4th~9th, 2019. As subjects of study, the characteristics of two housing complex built in Ishinomaki City with different supply subjects were compared and analyzed. As a result of this study, Japan has a clear distinction of terms for emergency housing, which are divided into rental and construction types. With the close cooperation between the government, local governments and construction companies, providing a prompt systematic supply is possible. The characteristics of emergency housing are differ depending on supply subjects. The emergency housing of JPA has diversity of plane, two rooms facing south, and fast construction time, while the emergency housing of the general construction company has a flexible spatial transformation and excellence of materials.

Seismic progressive collapse mitigation of buildings using cylindrical friction damper

  • Mirtaheri, Masoud;Omidi, Zobeydeh;Salkhordeh, Mojtaba;Mirzaeefard, Hamid
    • Earthquakes and Structures
    • /
    • 제20권1호
    • /
    • pp.1-12
    • /
    • 2021
  • The occurrence of progressive collapse induced by the removal of the vertical load-bearing element in the structure, because of fire or earthquake, has been a significant challenge between structural engineers. Progressive collapse is defined as the complete failure or failure of a part of the structure, initiating with a local rupture in a part of the building and can threaten the stability of the structure. In the current study, the behavior of the structures equipped with a cylindrical friction damper, when the vertical load-bearing elements are eliminated, is considered in two cases: 1-The load-bearing element is removed under the gravity load, and 2-The load-bearing element is removed due to the earthquake lateral forces. In order to obtain a generalized result in the seismic case, 22 pair motions presented in FEMA p 695 are applied to the structures. The study has been conducted using the vertical push down analysis for the case (1), and the nonlinear time-history analysis for the second case using OpenSEES software for 5,10, and 15-story steel frames. Results indicate that, in the first case, the load coefficient, and accordingly the strength of the structure equipped with cylindrical friction dampers are increased considerably. Furthermore, the results from the second case demonstrate that the displacements, and consequently the forces imposed to the structure in the buildings equipped with the cylindrical friction damper substantially was reduced. An optimum slip load is defined in the friction dampers, which permits the damper to start its frictional damping from this threshold load. Therefore, the optimum slip load of the damper is calculated and discussed for both cases.

Dynamic characteristics of single door electrical cabinet under rocking: Source reconciliation of experimental and numerical findings

  • Jeon, Bub-Gyu;Son, Ho-Young;Eem, Seung-Hyun;Choi, In-Kil;Ju, Bu-Seog
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2387-2395
    • /
    • 2021
  • Seismic qualifications of electrical equipment, such as cabinet systems, have been emerging as the key area of nuclear power plants in Korea since the 2016 Gyeongju earthquake, including the high-frequency domain. In addition, electrical equipment was sensitive to the high-frequency ground motions during the past earthquake. Therefore, this paper presents the rocking behavior of the electrical cabinet system subjected to Reg. 1.60 and UHS. The high fidelity finite element (FE) model of the cabinet related to the shaking table test data was developed. In particular, the first two global modes of the cabinet from the experimental test were 16 Hz and 24 Hz, respectively. In addition, 30.05 Hz and 37.5 Hz were determined to be the first two local modes in the cabinet. The high fidelity FE model of the cabinet using the ABAQUS platform was extremely reconciled with shaking table tests. As a result, the dynamic properties of the cabinet were sensitive to electrical instruments, such as relays and switchboards, during the shaking table test. In addition, the amplification with respect to the vibration transfer function of the cabinet was observed on the third floor in the cabinet due to localized impact corresponding to the rocking phenomenon of the cabinet under Reg.1.60 and UHS. Overall, the rocking of the cabinet system can be caused by the low-frequency oscillations and higher peak horizontal acceleration.

성능스펙트럼법을 이용한 기존 학교 건축물의 내진성능평가 및 보강효과 검증 (An Evaluation of Seismic Performance for Existing School Building Using Capacity Spectrum Method)

  • 장정현;황지훈;양경석;;최재혁
    • 공학기술논문지
    • /
    • 제5권1호
    • /
    • pp.11-18
    • /
    • 2012
  • Large scale earthquake was occurred in different parts of the world like Japan (in 1995), Republic of Pakistan (2005), in China (2008) etc and enormous structures were damaged. As a result of collapse of school buildings structures numerous students are died and it had a big impact on the international community. Therefore, the interest of preparing the seismic resistant school building structures in our country is increases as school building are used as emergency shelter for local residents. But the current standard of seismic design ratio of 3.7% is applied for school building in Korea which is only significant earthquake damage is expected. In order to overcome the current situation, seismic performance evaluation is carried out for the existing school building and an accurate and appropriate seismic retrofit is required based on performance evaluation to upgrade the existing school buildings. In this paper, nonlinear analysis on existing school buildings for ATC-40(Applied Technology Council, ATC) and FEMA-356(Federal Emergency Management Agency, FEMA) are carried out using the capacity spectrum method to evaluate seismic performance and to determine the need for retrofitting. In addition, after reinforcement to enhance the seismic performance is applied the seismic performance evaluation is carried out to verify the effectiveness of seismic retrofit.

부분구조추정법을 이용한 대형구조물의 효율적인 구조안전도 모니터링 (Efficient Structral Safety Monitoring of Large Structures Using Substructural Identification)

  • 윤정방;이형진
    • 한국지진공학회논문집
    • /
    • 제1권2호
    • /
    • pp.1-15
    • /
    • 1997
  • 본 논문에서는 대형구조물에서 구조물의 안전성 평가와 관련하여 구조물이 국부손상도를 추정하기 위한 효율적인 부분구조추정(Substructural Identification) 기법에 대하여 연구하였다. 먼저, 부분구조 추정법을 위한 모형식을 설정하기 위하여 운동방정식으로부터 부분구조에 대한 계측오차를 처리하기 위한 모형을 포함한 추계론적 자동회귀-이동평균(ARAMX) 모형식을 유도하였다. 추정된 모형식의 계수는 유도된 관계식을 이용하면, 구조손상 평가에 이용될 수 있는 강성행렬로 환산될 수 있다. 본 논문에서 유도된 부분구조 추정법의 가장 큰 장점은 매우 안정되고 정확도가 우수한 구조추정법인 ARMAX 모형식에 기반한 순차적 예측오차 방법을 사용함으로써 다른 방법에 비해 추정의 안정성 및 정확도가 뛰어나다는 것이다. 다음으로는 개발된 부분구조 추정법을 이용하여 구조 손상도 추정이 수행되었다. 손상도 추정을 위하여 앞서 순차적 예측오차 방법을 이용하여 추정된 구조계 현상태의 강성행렬을 바탕으로, 최소지승법을 이용하여 구하는 간접법이 제시되었다. 제시된 방법들의 검증을 위하여 예제해석이 수행되었다. 트러스 및 연속교 모형 그리고 실험적 예제에 적용하여 구조의 강성행렬 및 감쇠행렬을 추정하였다. 이를 바탕으로 손상도 추정방법이 검증되었다. 해석결과로부터, 개발된 방법이 효율적이고 정확도 및 안정성의 측면에서 우수한 성질이 있음을 확인할 수 있다.

  • PDF

수도권 열섬 중심으로부터 교외까지의 거리 및 국지적 지표특성이 야간 기온분포에 미치는 영향 (Impact of the Local Surface Characteristics and the Distance from the Center of Heat Island to Suburban Areas on the Night Temperature Distribution over the Seoul Metropolitan Area)

  • 이채연;김규랑;안승만;최영진
    • 한국지리정보학회지
    • /
    • 제17권1호
    • /
    • pp.35-49
    • /
    • 2014
  • 서울과 주변을 포함하는 수도권에서 발생하는 열섬현상의 특성들을 정량적으로 이해하기 위하여 GIS 및 AWS 관측 자료들을 이용하여 여름과 겨울 야간 기온분포의 공간 경향 그래프를 작성하였다. 또한 기온 변동성에 영향을 미치는 요인들과 31개 AWS 지점들의 야간 평균기온과의 상관성을 분석을 하였다. 그 결과, 야간 평균기온(2004년~2011년) 최고지점과 최저지점의 차이는 여름 $4.5^{\circ}C$, 겨울 $7.1^{\circ}C$ 임을 확인하였다. AWS 지점들 주변의 국지적 지표특성과 기온과의 상관성 분석 결과, 지점별 야간 평균 기온과 반경 1km 이내의 인공피복의 상관계수가 여름(0.84)과 겨울(0.78) 모두에서 높게 나타나 지표면 피복이 중규모적인 도시 열환경 관리에 있어 다른 요인들보다 더 큰 영향을 주는 요인임을 확인하였다. 한편 수도권 야간기온에 대한 회귀모형을 변수선택법을 이용하여 개발한 결과 1km 규모에서 보다 200m 규모에서 상세한 지표특성 변수가 선택됨을 알 수 있었는데, 규모에 따른 모형의 설명력에는 큰 차이가 없었다. 따라서 200m 정도의 상세한 지표특성 자료를 이용하는 기후분석 모델의 구현이 가능함을 알 수 있었으며, 모델의 설명력은 1km 수준으로 분석하였을 때와 비슷한 수준인 57%(겨울)~72%(여름)이었다.

유전자알고리즘을 이용한 스마트 면진시스템의 퍼지제어 (Fuzzy Control of Smart Base Isolation System using Genetic Algorithm)

  • 김현수
    • 한국지진공학회논문집
    • /
    • 제9권2호통권42호
    • /
    • pp.37-46
    • /
    • 2005
  • 현재까지 많은 스마트 면진시스템이 제안되었고 연구되어 왔다. 본 연구에서는 스마트 면진시스템의 면진장치와 보조감쇠 장치로서 새로운 형태의 마찰진자시스템(FPS)과 MR 감쇠기를 각각 사용한다. 퍼지로직제어기(FLC)가 고유의 견실성과 비선형 및 불확실성을 쉽게 다룰 수 있는 능력이 있기 때문에 MR 감쇠기의 감쇠력을 조절하는데 FLC를 사용한다. 또한 FLC의 성능을 최적화 하기 위해서는 유전자알고리즘(GA)을 사용한다. GA를 사용함으로써 소속함수의 형상을 조절하는 것뿐만 아니라 적절한 퍼지제어규칙을 결정할 수 있다. 이를 위하여 본 연구에서는 부분개선 유전자알고리즘을 사용하였다. 이 방법은 유전자의 특정부분을 향상시키는데 효율적이다. FPS와 MR 감쇠기의 동적거동을 표현하기 위해서는 뉴로?퍼지 모델을 사용한다. FLC의 최적설계를 위하여 본 연구에서 제안된 방법의 효율성은 여러 가지 역사지진을 사용하여 계산된 동적응답을 기초로 하여 평가한다. 예제해석결과 제안된 방법은 적절한 퍼지규칙을 찾을 수 있고 GA로 최적화된 FLC는 수동제어기 뿐만 아니라 전문가의 지식에 기반한 FLC와 전통적인 준능동제어기보다 더 좋은 성능을 발휘한다.

재해 지역의 기록화 사례 연구 - 한신·아와지 대지진 기록관리 사례를 중심으로 - (A Case Study on the Documentation in a Disaster Area - On the Basis of Great Hanshin-Awaji Earthquake -)

  • 이미영
    • 기록학연구
    • /
    • 제21호
    • /
    • pp.85-116
    • /
    • 2009
  • 기록은 지역에 대한 공동기억을 담고 있는 사회적 기억장치로, 공공기록만으론 사회의 모든 모습을 담거나 재현할 수는 없다. 일본은 '한신 아와지 대지진'을 겪으면서 비록 체계적인 도큐멘테이션 전략에 의한 것은 아니었지만 기관간 협력수집의 가능성과 적극적인 기록 생산 수집 노력을 보여주었다. 이 과정에서 나타난 특징은 다음과 같이 정리될 수 있다. 첫째, 수집에 있어 적극적인 협력 및 분담 노력이다. 특히 공공기관 보다 민간의 활동이 돋보이는데 기관간 협력 노력은 더 많은 사회기억과 역사기록을 다음 세대로 전하는 단초가 되었다. 둘째, 적극적인 관련기록의 생산과 수집이다. 민간단체도 여러 활동의 기록을 스스로 남기기도 하였다. 경험을 구체적으로 기록하여 후세에 남기는 것은 살아남은 이들의 책임이라고 인식했는데, 지진이라는 큰 사건을 겪으면서 스스로의 체험을 기록화해야 한다는 사명감과 역사의식이 성장했음을 인정하지 않을 수 없다. 셋째, 기록의 수집범위에 한계가 없었다는 점이다. '한 점이라도 많은 기록자료를 후세에 전달하자', '일상적인 것들이어서 자료나 기록이라고 생각하지 못했던 것들도 당시의 상황을 나타내는 귀중한 "삶의 정보"로 후세에 남길 가치가 있다'라는 몇몇 기관의 구호처럼 재해 지역이라는 울타리 안에 있던 사람과 장소에 대한 모든 기록은 수집대상이었다. 이 사례에서 우리는 사회의 무엇을, 어떻게, 왜 다음 세대에게 전할 것인가에 대한 특정 계층의 뛰어넘은 의지와 열정을 확인할 수 있었는데, 이는 민간영역의 기록화를 모색해야 하는 우리에게 시사하는 바가 많다.

볼팅 고정 채널 형강 보강재를 이용한 비좌굴 Knee Bracing System의 내진성능에 대한 실험 연구 (Experimental Study on Buckling Restrained Knee Bracing Systems Using Bolted Channel Sections)

  • 이진;이기학;이성민;신지욱;김영민
    • 한국지진공학회논문집
    • /
    • 제13권2호
    • /
    • pp.37-46
    • /
    • 2009
  • 본 연구에서는 1층 1경간 실제크기의 가력 프레임에서 내진보강에 적합한 비좌굴 knee brace을 설치하여 주기하중을 통해 가새의 지진저항능력을 실험하였다. 볼트 고정 채널이 이용된 비좌굴 knee brace는 지진력에 저항하는 코어와 두 개의 철골 플레이트로 만들어졌고 단면의 형태는 코어의 국부좌굴과 횡좌굴에 저항하도록 하였다. 비좌굴 kneebrace는 현장에서 조립이 용이하고, 시공방법 또한 간단하여 공간에 제약이 있는1층에 필로터를 가진 중저층 RC건물의 내진 보수/보강에 효과적으로 사용할 수 있다. 각 실험체에 대한 변수로 중심코어의 크기와 외부 보강재의 크기, 가이드 플레이트의 유무 등으로 정하였으며, 실험을 통해 얻어진 힘-변위 이력곡선을 통해 중심코어의 크기가 가장 큰 영향을 미치는 것으로 나타났다. 또한 가이드 플레이트의 유무에 따라 압축강도 수정계수와 파괴형태가 달라지는 것을 알 수 있었다. 각 실험체에 대한 결과는 AISC 2005 Seismic Provisions 규정에서 제시한 누적 연성도와 누적 소산에너지 측면에서도 충분한 효과를 발휘하는 것으로 나타났다.

Quanterra 기록계의 실시간 이벤트 패킷을 이용한 진앙 추정 (Epicenter Estimation Using Real-Time Event Packet of Quanterra digitizer)

  • 임인섭;신동훈;신진수;정순기
    • 지구물리와물리탐사
    • /
    • 제12권4호
    • /
    • pp.316-327
    • /
    • 2009
  • 1999년 국내 지진관측소 표준안이 제안된 이후로, 주요 지진관측 기관 대부분의 관측소에는 Quanterra 기록계가 설치되어 운영되고 있다. Quanterra 기록계에서는 실시간 이벤트 패킷과 데이터 패킷이 생성, 전송된다. 이벤트 패킷의 특성과 각 성분별 데이터 패킷의 데이터 센터 도착 시간을 분석하였다. 초당 100샘플의 속도 자료 기반 실시간 이벤트 패킷의 신호 대 잡음비와 신호 주기를 이용하여 실제 지진의 P파와 연관이 있는 패킷 선택 기준을 도출하였다. 선택된 이벤트 패킷의 시간 정보를 이용, 진앙을 추정하고 분석하였다. 시험 운영 결과 이벤트 패킷은 데이터 패킷에 비해 평균 3~4초 빨리 도착하며, 그 개수도 데이터 패킷에 비해 0.3%에 불과하다. 전체 이벤트 패킷 중 약 5% 만이 실제 지진의 P파와 연관된 이벤트 패킷으로 선택되었다. 선택된 이벤트 패킷을 이용하여 내륙에서 발생한 규모 2.5 이상의 지진에 대해서는 20초 이내에 10 km 이내의 오차로 진앙을 결정할 수 있었다.