• Title/Summary/Keyword: Local dust

Search Result 176, Processing Time 0.028 seconds

Characteristics of Air Quality over Korean Urban Area due to the Long-range Transport Haze Events (장거리 수송 연무 발생과 연관된 우리나라 대도시 대기질 특성)

  • Jo, Hyun-Young;Kim, Cheol-Hee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.1
    • /
    • pp.73-86
    • /
    • 2011
  • Haze phenomena were analyzed to assess the impact of long range transport process on the air quality of Seoul and Busan. We statistically classified haze days observed in both Seoul and Busan into two types of haze cases: stagnant case and long-range transport case, and analyzed the air pollutant levels comparatively for each of the two cases for the period of 2000~2007. The results showed that the long-range transport haze case occurs less frequently with the occurrence frequency of 35.5% than stagnant case with the occurrence frequency of 64.5%. During the observed all haze days, all pollutants have high concentration in comparison with those under other meteorological conditions (Rain, Mist, Dust, Clear, Rain+Mist) except for only $PM_{10}$ of Dust case where its level shows highest among total 6 categorized conditions. The long range transport haze case shows similar levels of $PM_{10}$ and $NO_2$, but higher $SO_2$ and lower $O_3$ compared with stagnant haze cases, suggesting the importance of sulfur chemistry for long range transport haze case and local photochemistry for stagnant haze case. In addition, by employing the NOAA/HYSPLIT-4 backward trajectory model, we subdivided the long range transport haze cases into two different sources: urban anthropogenic high emission areas of central China, and natural emission sources over north China and/or Mongolia. The former long range transport haze case shows higher occurrence (with Seoul 70% and Busan 85%) than the latter haze case (with Seoul 30% and Busan <10%). This is also implying that the long haze phenomena occurred over Korea have been influenced by not only the anthropogenic emissions but also the natural dust emissions. These both emission sources can be good contributors in calculating the source-receptor relationship over Korean atmospheric environment.

MONTE-CARLO RADIATIVE TRANSFER MODEL OF THE DIFFUSE GALACTIC LIGHT

  • Seon, Kwang-Il
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.1
    • /
    • pp.57-66
    • /
    • 2015
  • Monte-Carlo radiative models of the diffuse Galactic light (DGL) in our Galaxy are calculated using the dust radiative transfer code MoCafe, which is three-dimensional and takes full account of multiple scattering. The code is recently updated to use a fast voxel traversal algorithm, which has dramatically increased the computing speed. The radiative transfer models are calculated with the generally accepted dust scale-height of 0.1 kpc. The stellar scale-heights are assumed to be 0.1 or 0.35 kpc, appropriate for far-ultraviolet (FUV) and optical wavelengths, respectively. The face-on optical depth, measured perpendicular to the Galactic plane, is also varied from 0.2 to 0.6, suitable to the optical to FUV wavelengths, respectively. We find that the DGL at high Galactic latitudes is mostly due to backward or large-angle scattering of starlight originating from the local stars within a radial distance of r < 0.5 kpc from the Earth. On the other hand, the DGL measured in the Galactic plane is mostly due to stars at a distance range that corresponds to an optical depth of $${\sim_\sim}$$ 1 measured from the Earth. Therefore, the low-latitude DGL at the FUV wavelength band would be mostly caused by the stars located at a distance of $r{\leq}0.5$ kpc and the optical DGL near the Galactic plane mainly originates from stars within a distance range of $1{\leq}r{\leq}2kpc$. We also calculate the radiative transfer models in a clumpy two-phase medium. The clumpy two-phase models provide lower intensities at high Galactic latitudes compared to the uniform density models, because of the lower effective optical depth in clumpy media. However, no significant difference in the intensity at the Galactic plane is found.

Far-ultraviolet study of the GSH006-15+7: A local Galactic supershell

  • Jo, Young-Soo;Min, Kyoung-Wook;Seon, Kwang-Il
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.61.1-61.1
    • /
    • 2014
  • GSH 006-15+7 is a Milky Way supershell discovered by Moss et al. (2012). This supershell shows large shell-like structures in H I velocity maps. We have analyzed FUV emission for the supershell regions based on the FIMS and GALEX observations. Bright FUV flux at the boundaries of the supershell is mostly originated from dust scattering of FUV photons by dust clouds which was also observed at the boundaries of the supershell. We could find the distance to the supershell can be closer more than 30% compared with the distance of 1500 pc suggested by Moss et al. (2012) from the dust scattering simulation. And we also found the albedo and the phase function asymmetry factor of interstellar grains were 0.30 and 0.40, respectively. The confidence range for the albedo covers the theoretical value of 0.40, but g-factor is rather smaller than the theoretical value of 0.65. The small g-factor might mean the environment of turbulent ISM of the supershell. Meanwhile, the excess of C IV and X-ray emissions in the inside of the supershell can support the existence of hot gas and cooling in the supershell. And the C IV and X-ray emissions are monotonically decrease as away from the center of the SNR. This indicates the size of the hot bubble has considerably shrunk. We applied a simple simulation model to the PDR candidate region of the lower part of the supershell and obtained a H2 column density N(H2) = 1017.0-18.0 cm-2 and total hydrogen density nH ${\geq}$ 10 cm-3. This result shows the PDR candidate region represents a transition region from the warm phase to the cool phase in the PDR.

  • PDF

Far-ultraviolet Observations of the Taurus-Perseus-Auriga Complex

  • Lim, Tae-Ho;Min, Kyoung-Wook;Seon, Kwang-Il
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.98.2-98.2
    • /
    • 2012
  • We firstly present the unified Far-UV continuum map of the Taurus-Auriga-Perseus (TPA) complex, one of the largest local associations of dark cloud located in (l, b)=([154,180], [-28, -2]), by merging both FIMS and GALEX. The FUV continuum map shows that dust extinction correlate well with the FUV around the complex. It shows strong absorption in FUV toward the dense Taurus cloud while it does not in California cloud. It turned out that it is related to the relative location of each cloud and Perseus OB2 association. We also present some results of dust scattering simulation based on Monte Carlo Radiative Transfer technique (MCRT). Through this dust scattering simulation, we have derived the scattering parameter for this region, albedo(a)=$0.42^{+0.05}{_{-0.05}}$, asymmetry factor(g)=$0.47^{+0.11}{_{-0.27}}$. The optical parameters we obtained seem reasonable compared to the theoretical model values ~0.40 and ~0.65 for the albedo and the phase function though the phase function is rather small. Using the result of simulation, we figured out the geometries of each cloud in the complex region, especially their distances and thicknesses. Our predictions from the results are in good agreement with the previous studies related to the TPA complex. For example, the Taurus cloud is within ~200pc from the Sun and the Perseus seems to be multi-layered, at least two. The California cloud is more distant than the other cloud on average at ~350 pc and Auriga cloud seems to be between the Taurus cloud and the eastern end of the California cloud. We figured out that across the TPA complex region, there might be some correlation between the LSR velocity and the distance to each cloud in the complex.

  • PDF

Exposure Assessment of Tile Manufacturing Workers to Crystalline Silica (타일 제조 작업자의 결정형 유리규산 노출평가 사례)

  • Won-Seok Cha;Eun-Young Kim;Dae-Ho Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.3
    • /
    • pp.291-297
    • /
    • 2023
  • Objectives: An epidemiological investigation was requested for a worker who developed COPD and IPF after long-term molding and firing at a domestic tile manufacturing site. We would like to share the results of the exposure assessment and the estimation of past work. Methods: The content of crystalline silica in four raw materials was analyzed, and the respirable fraction of crystalline silica and dust generated in the air from molding and firing workers and other processes were measured. The measurement and analysis method referred to the NIOSH method. Results: The crystalline silica content of the raw material was 24~47%. The concentration of crystalline silica in the molding and firing process workers and the surrounding area was at the level of the exposure standards set by the Ministry of Employment and Labor and ACGIH, and the respirable and total dust exposure levels were generally low. The crystalline silica concentration of the area samples measured to estimate past work was about twice as high as the exposure standard of the Ministry of Employment and Labor (0.05 mg/m3), and the exposure levels of respirable dust were also quite high at 0.903 and 1.332 mg/m3. Conclusions: It was confirmed that tile molding and firing workers are currently exposed to a fairly high level of crystalline silica, and a high level is also confirmed in area samples to estimate past work. In the past, it is judged that the level of exposure would have been much higher due to differences in production volume, working method, presence/absence of local ventilation facilities, and process layout. When working in such a working environment for a long time, respiratory diseases such as lung cancer, COPD, and IPF can occur.

A Study of Local Ventilation Design on PC Programm (국소환기 설계의 전산화에 관한 연구)

  • Yoon, Myong Cho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.2
    • /
    • pp.213-226
    • /
    • 1993
  • The purpose of this study is to computerize the design of single source for a duct work system which is essential for the improvement of working places. There are different types of hood, such as general hood, push pull hood and canopy hood. And out of these three types, general hood and canopy hood were used as subjects of this study. The software used here was Quattro Pro 123 programm, and the hardware was IBM PS/SX(type 5510-SK4 S/N 83-05164). And the results are tabulated in

    and
    . All of the hazardous factors of working places, except for physical factors, such as noise, vibration, illumination and etc, are control measurement related. In order words, workiong places that have problems with toxic gas, mist, fume, dust, odors, biological factors or wetness can be improved by means of the local ventilation design. However, the reqires very complicate processes, and in the case of canopy hood, particularly, one runs into difficulties due to frequent discrepancies generated from calculations through many processes. Recently, progress of the computer hardware technics has been dazzling, and also the software is development rapidly. As proven in the results of this study, it is good that designs for industrial ventilation systems are readily available for easy use. It is hopeful that young scholars will develop easier and quicker methods for local ventilation designs in the future.

  • PDF
  • Status of Welding Fume Concentration and Local exhaust Ventilation System at Welding Laboratory in Technical High School (공업고등학교 용접실습실의 용접흄 발생농도와 국소배기 실태)

    • Hwang, Sung-Hwan;Son, Bu-Soon;Jang, Bong-Ki;Park, Jong-An;Lee, Jong-Wha
      • Journal of Korean Society of Occupational and Environmental Hygiene
      • /
      • v.11 no.1
      • /
      • pp.1-8
      • /
      • 2001
    • This study was performed to evaluate a local exhaust ventilation system capability and welding fume concentration in welding laboratory at 5 technical high schools. Results of the study are as follows; 1. The personal exposure of welding fume in welding laboratory was measured. The geometric mean of 73 personal samples was $6.27mg/m^3$($3.85{\sim}9.88mg/m^3$), and 68.5% of these exceeded TLV of the Korea Ministry of Labor. 2. The geometric mean of welding fume at outside of booth was $2.27mg/m^3$($1.57{\sim}2.58mg/m^3$). All of measured concentrations were lower than TLV of the Korea Ministry of Labor. 3. Local exhaust ventilation system in welding laboratory could not remove hazardous substance effectively because of inappropriate canopy hood and absurd design. 4. The possibility of exposure risk was estimated to be high because of working point under breathing zone, misplacement of working table and insufficient supply of respiratory protector. 5. The mean values of capture velocity and transportation velocity of local exhaust ventilation system in welding laboratory were 0.38m/sec, 4.27m/sec respectively. These values were satisfied the guideline of the Korea Ministry of Labor. 6. The efficiency of performance of local ventilation system was anticipated to be decreased because of accumulated dust and alien substance on fan and duct.

    • PDF

    A Survey on Elementary Students' Perceptions about Global and Local Environmental Issues (초등학생의 전지구적 및 지역적 환경 문제에 대한 인식 조사)

    • Jang, Bo-Ra;So, Keum-Hyun;Shim, Kew-Cheol;Yeau, Sung-Hee
      • Journal of Korean Elementary Science Education
      • /
      • v.28 no.2
      • /
      • pp.142-153
      • /
      • 2009
    • The purpose of this study was to survey primary students' perception of the global and local environmental issues. The subjects were 853 fifth primary students in Seoul, Busan, Daejeon, Anyang, Gimpo and Cheongju. The results were as follows: First, the perception level of the global environmental issues were global warming (M=3.99), drinking-water pollution (M=3.92), acid rain (M=3.77), yellow dust (M=3.66), ozone depletion (M=3.57), deforestation in tropical areas (M=3.52), desertification (M=3.36), biodiversity (M=3.40) and their perception level of local environmental issues were waste disposal (M=3.87), air pollution (M=3.74), bad smell (M=3.70), noise (M=3.61), river pollution (M=3.57), soil pollution (M=3.44). Second, it was shown that the metropolitan students' perception levels of environmental issues were higher than the non-metropolitan students'. There wasn't a significant difference in the perception levels of two scale environmental issues and characteristics for sex (p>.05). Third, the result of analyzing on the effects between characteristics was that the factors like 'environmental interest' and 'impact on personal life' had a strong influence on the 'behavior will' to solve the global environmental issues, and 'environmental interest' and 'personal knowledge' had a strong influence on the 'behavior will' to solve the local environmental issues. Fourth, the result of analyzing on the characteristics according to the types of the environmental issues showed that 'personal knowledge', 'environmental interest' and 'behavior will' were high in the global environmental issues (p<.01) and 'virtual contamination', 'human responsibility' and 'impact on personal life' were high in the local environmental issues (p<.05).

    • PDF

    A Study on Feasibility and Applicability of Pneumatic Waste Collection System (쓰레기 수송관로 방식의 적용사례 및 실용에 관한 연구)

    • 민병균;이재영;최상일
      • Journal of Korea Soil Environment Society
      • /
      • v.2 no.1
      • /
      • pp.109-117
      • /
      • 1997
    • The dust chute was a part of equipment in apartment which have been settled down as new residential style in this country since 1960s. However, the dust chute was destructed by results of social discussion, and it ended up old remains which cannot be found in new towns. Nowadays, chute was substituted a collecting system from extra collecting sites which were prepared near residential area. This phenomenon was caused by the poor separating collection. Since the early part of 1995, the whole vocal operating the volume-base charge system has been placed as the institution capable of recycling and separating collection of residential wastes in this country. People pursue the residential quality which is suitable to the Greenround period. Such a diverse effort corresponding to the social change can be also accomplished in the field of waste collecting transportation. In this paper, the local heating system and waste combustion site and hollow are already applied to the new residential area in the form of housing development. After investigating of the waste collecting transportation method in other countries related to such facilities, this paper represents the feasibility and applicability of pneumatic waste collection system which is used practically in the new housing complex and large facilities in other countries.

    • PDF

    Fine dust(PM10) emission calculated of Dong-Hae harbor around area using inverse modeling technique (역모델링 기법을 이용한 동해항 주변지역 미세먼지 배출량 산출)

    • Kim, Ji-Hyun;Park, Young-Koo
      • Journal of the Korean Applied Science and Technology
      • /
      • v.32 no.4
      • /
      • pp.649-660
      • /
      • 2015
    • Data obtained from the Calpuff inverse modeling estimate the emission amount of pollutants, and enable to establish the aim for reduction through the comparison of various cases. This study pursued to accumulate the fundamental data by the Calpuff inverse modeling for five areas in the vicinity of Donghae harbor, which focused on reduction of atmospheric fine dust. As a result of evaluation of the allowed emission amount for local sites, site-D required the most reduction, $4.95{\mu}g/m^2{\cdot}S$, based on the atmospheric guideline, $50{\mu}g/m^3$. The theoretical mitigation could decrease the average concentration of PM10 to $42.6{\mu}g/m^3$ for the study field (Donghae waste water treatment plant). Modeling only for site-A emission showed the potential concentration around the residential area of Donghae harbor, $40{\sim}50{\mu}g/m^3$. However, it will rise over $50{\mu}g/m^3$ with the addition of background level. Therefore no more emission would be allowed. Site-B including commercial area and unpaved field required the reduction of $0.11{\mu}g/m^2{\cdot}S$ due to vehicles and fugitive dust. Site-C and E did not emit additional pollutants.


    (34141) Korea Institute of Science and Technology Information, 245, Daehak-ro, Yuseong-gu, Daejeon
    Copyright (C) KISTI. All Rights Reserved.