Status of Welding Fume Concentration and Local exhaust Ventilation System at Welding Laboratory in Technical High School

공업고등학교 용접실습실의 용접흄 발생농도와 국소배기 실태

  • Hwang, Sung-Hwan (Department of Environmental Health Science, Soonchunhyang University) ;
  • Son, Bu-Soon (Department of Environmental Health Science, Soonchunhyang University) ;
  • Jang, Bong-Ki (Department of Environmental Health Science, Soonchunhyang University) ;
  • Park, Jong-An (Department of Environmental Health Science, Soonchunhyang University) ;
  • Lee, Jong-Wha (Department of Environmental Health Science, Soonchunhyang University)
  • 황성환 (순천향대학교 환경보건학과) ;
  • 손부순 (순천향대학교 환경보건학과) ;
  • 장봉기 (순천향대학교 환경보건학과) ;
  • 박종안 (순천향대학교 환경보건학과) ;
  • 이종화 (순천향대학교 환경보건학과)
  • Received : 2001.02.02
  • Accepted : 2001.03.22
  • Published : 2001.05.30

Abstract

This study was performed to evaluate a local exhaust ventilation system capability and welding fume concentration in welding laboratory at 5 technical high schools. Results of the study are as follows; 1. The personal exposure of welding fume in welding laboratory was measured. The geometric mean of 73 personal samples was $6.27mg/m^3$($3.85{\sim}9.88mg/m^3$), and 68.5% of these exceeded TLV of the Korea Ministry of Labor. 2. The geometric mean of welding fume at outside of booth was $2.27mg/m^3$($1.57{\sim}2.58mg/m^3$). All of measured concentrations were lower than TLV of the Korea Ministry of Labor. 3. Local exhaust ventilation system in welding laboratory could not remove hazardous substance effectively because of inappropriate canopy hood and absurd design. 4. The possibility of exposure risk was estimated to be high because of working point under breathing zone, misplacement of working table and insufficient supply of respiratory protector. 5. The mean values of capture velocity and transportation velocity of local exhaust ventilation system in welding laboratory were 0.38m/sec, 4.27m/sec respectively. These values were satisfied the guideline of the Korea Ministry of Labor. 6. The efficiency of performance of local ventilation system was anticipated to be decreased because of accumulated dust and alien substance on fan and duct.

Keywords