• Title/Summary/Keyword: Local Temperature

Search Result 1,936, Processing Time 0.034 seconds

An Evaluation of Extreme Precipitation based on Local Downpour using Empirical Simulation Technique (Empirical Simulation Technique 기법을 이용한 집중호우의 극한강우 평가)

  • Oh, Tae-Suk;Moon, Young-Il
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.2B
    • /
    • pp.141-153
    • /
    • 2009
  • The occurrence causes of the extreme rainfall to happen in Korea can be distinguished with the typhoons and local downpours. The typhoon events attacked irregularly to induce the heavy rainfall, and the local downpour events mean a seasonal rain front and a local rainfall. Almost every year, the typhoons and local downpours that induced a heavy precipitation be generated extreme disasters like a flooding. Consequently, in this research, There were distinguished the causes of heavy rainfall events with the typhoons and the local downpours at Korea. Also, probability precipitation was computed according to the causes of the local downpour events. An evaluation of local downpours can be used for analysis of heavy rainfall event in short period like a flash flood. The methods of calculation of probability precipitation used the parametric frequency analysis and the Empirical Simulation Technique (EST). The correlation analysis was computed between annual maximum precipitation by local downpour events and sea surface temperature, moisture index for composition of input vectors. At the results of correlation analysis, there were revealed that the relations closely between annual maximum precipitation and sea surface temperature. Also, probability precipitation using EST are bigger than probability precipitation of frequency analysis on west-middle areas in Korea. Therefore, region of west-middle in Korea should prepare the extreme precipitation by local downpour events.

Development of MR Compatible Coaxial-slot Antenna for Microwave Hyperthermia (초고주파 가열치료를 위한 MR 호환 동축 슬롯 안테나의 개발)

  • Kim, T.H.;Chun, S.I.;Han, Y.H.;Kim, D.H.;Mun, C.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.4
    • /
    • pp.333-340
    • /
    • 2009
  • MR compatible coaxial-slot antenna for microwave hyperthermia was developed while its structure and size of each part were determined by computer simulation using finite element method(FEM). Its local heating performance was evaluated using tissue-mimic phantom and swine muscles. 2% agarose gel mixed with 6mM/$\ell$ $MnCl_2$ as a biological tissue-mimic phantom was heated by the proposed antenna driven by a 2.45GHz microwave generator. The temperature changes of the phantom were monitored using multi-channel digital thermometer at the distance of 0mm, 5mm, 10mm and 20mm from the tip center of the antenna. Also muscle tissue of swine was heated for 2 and 5minutes with 50W and 30W of microwave generator powers, respectively, to evaluate the local heating performance of the antenna. MRI compatibility was also verified by acquiring MR images and MR temperature map. MR signals were acquired from the agarose gel phantom using $T2^*$ GRE sequence with 1.5T clinical MRI scanner(Signa Echospeed, GE, Milwaukee, WI, U.S.A.) at Pusan Paik Hospital and were transferred to PC in order to reconstruct MR images and temperature map using proton resonance frequency(PRF) method and laboratory-developed phase unwrapping algorithm. Authors found that it has no severe distortion due to the antenna inserted into the phantom. Finally, we can conclude that the suggested coaxial-slot antenna has an excellent local heating performance for both of tissue-mimic phantom and swine muscle, and it is compatible to 1.5T MRI scanner.

Analysis of the Physiological Signal Measured by Oriental Medicine Instruments in the View of the Rule of Promoting and Counteracting Relation of the Five Evolutive Phases (한방기기(韓方機器)로 측정(測定)한 생리신호(生理信號)의 오행(五行) 생극제화규율적(生剋制化規律的) 해석(解析))

  • Jang, K.S.;Choi, J.W.;Jean, C.S.;Na, C.S.;So, C.H.
    • Korean Journal of Oriental Medicine
    • /
    • v.2 no.1
    • /
    • pp.84-103
    • /
    • 1996
  • The physiological signals measured by Oriental Medicine instruments have been analyzed quantitatively in the view of the rule of promoting and counteracting relation of five evolutive phases theory. We tried to reduce the physiological signals measured by EAV(Elec-tro-Acupuncture according to Voll) and IR thermography to the representation of five evelutive phases. The EAV index and local skin temperature on acupuncture points of each phases measured and normalized so that the total value of five phases became unity. We assumed that the normalized EAV index and local skin temperature mean the deficiency or excess of Qi for each phases. The state of Qi distribution for each phases were approximately agree with the diagnostic pattern of O. M. doctor. Taking account of the Qi distribution state of·or the five evolutive phases, we performed a proper needle insertion on acupuncture points to induce the distinct change of Qi for each phases. We compared the measured results with the predictions of Qi variation by the rule of pro- moting and counteracting relation over the five evolutive phases. For all cases, the variation of Qi in the own phase on which a needle insertion was performed were exactly same to the theoretical prediction and partial agreement was shown for the other four phases. The same analysis was carried to the results of skin temperature measurements at accupoints. We found that the local skin temperature at accupoints of each phases shelved a finite change by the needle insertion and the behavior- of its change were strongly correlated to the rule of promoting and counteracting relation of five evolutive phases.

  • PDF

Study on Evaluation of Local Cooling Performance using Piezoelectric and Thermoelectric Modules (압전소자와 열전소자를 이용한 국소부 냉각성능 평가에 관한 연구)

  • Oh, Hoo-suk;Choi, Byung-Hui
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.478-483
    • /
    • 2017
  • This paper investigated experimentally the performance of cooling systems using thermoelectric and piezoelectric modules for local heating and temperature control, such as a handheld electronic devices. The temperature distribution of the cooling region using thermoelectric modules was measured when the piezoelectric module was and was not with a frequency of 80Hz and 110Hz. The coefficients of performance were also calculated by the temperature results, and the thermo-flow phenomena in the cold region was visualized under the same conditions. The results of the temperature distribution measurements and the coefficient of performance showed that the cooling performance of the cooling system using thermoelectric modules can be improved by operating the piezoelectric module. In addition, when the piezoelectric module was operated based on the result of visualization in the cold region, which was formed by thermoelectric modules, the performance thermoelectric cooling was improved by the thermo-flow formed in the entire cold region as the forced convection of vibration was generated on the local cold region by the piezoelectric module.

Effect of Air Velocity on Combustion Characteristics in Small-Scale Burner

  • Laryea, Gabriel Nii;No, Soo-Young
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2005
  • This paper presents the combustion characteristics of hydrocarbon fuel from a conventional pressure-swirl nozzle of a small-scale burner. The nozzle has orifice diameters of 0.256 mm and liquid flow rates ranging from 50 to 64 mL/min were selected for the experiments. The furnace temperature distribution along the axial distance, the gas emission such as CO, $CO_2$, NOx, $SO_2$, flue gas temperature, and combustion efficiency were studied. The local furnace and flue gas temperatures decreased with an increase in air velocity. At injection pressures of 1.1 and 1.3 MPa the maximum furnace temperatures occurred closer to the burner exit, at an axial distance of 242 mm from the diffuser tip. The CO and $CO_2$concentrations decreased with an increase in air velocity, but they increased with an increase in injection pressure. The effect of air velocity on NOx was not clearly seen at low injection pressures, but at injection pressure of 1.3 MPa it decreased with an increase in air velocity. The effect of air velocity on $SO_2$ concentration level is not well understood. The combustion efficiency decreased with an increase in air velocity but it increased with an increase in injection pressure. It is recommended that injection pressure less than 0.9 MPa with air velocity not above 8.0 m/s would be suitable for this burner.

  • PDF

Characteristics of temperature change in friction between different metals (이종금속간마찰시 온도변화특성에 관한 연구)

  • 신문교;이우환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.50-58
    • /
    • 1987
  • At present it has been cleared that even carefully polished surfaces have irregularities on them which are large compared with molecular dimensions by the progress of a scanning electron microscope. When two solids are placed together, the real area of contact is very small, so that the local pressure is high and, in general, exceeds the yield pressure of the metal. Plastic flow of the solid occurs at the summits of the irregularities so that the real area of contact is proportional to the applied load. There is adhesion at local resions of contact and the friction is, in a large measure, the force required to shear them. On this view point, the friction experiment with different specimens which are carbon steel, copper and constantan was attempted to know the characteristics of temperature change in contact with different metals. Various experiments are summerized as follows; 1) With metals of high melting point, momentary 1000 .deg. C may last below $10^{-4}$ of a second. It is thought that above phenomena back up previous adhesion theory in wear. 2) As a general rule, surface temperature in contact with different metals becomes high when the load increases while it is observed that surface temperature decreases when the load increases with shapes of specimens.

  • PDF

Effect of Air Velocity on Combustion Characteristics Scale Burner

  • Laryea, Gabriel Nii;No, Soo-Young
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • v.10 no.1
    • /
    • pp.76-82
    • /
    • 2005
  • This paper presents the combustion characteristics of hydrocarbon fuel from a conventional pressureswirl nozzle of a small-scale burner. The nozzle has orifice diameters of 0.256 mm and liquid flow rates raging from 50 to 64 mL/min were selected for the experiments. The furnace temperature distribution along the axial distance, the gas emission such as CO, $CO_2,\;NOx,\;S0_2,$ flue gas temperature, and combustion efficiency were studied. The local furnace and flue gas temperatures decreased with an increase in air velocity. At injection pressures of 1.1 and 1.3 MPa the maximum furnace temperatures occurred closer to the burner exit, at an axial distance of 242 mm from the diffuser tip. The CO and $CO_2$ concentrations decreased with an increase in air velocity, but they increased with an increase in injection pressure. The effect of air velocity on NOx was not clearly seen at low injection pressures, but at injection pressure of 1.3 MPa it decreased with an increase in air velocity. The effect of air velocity $SO_2$ concentration level is not well understood. The combustion efficiency decreased with an increase in air velocity but it increased with an increase in injection pressure. It is recommended that injection pressure less than 0.9 MPa with air velocity not above 8.0 m/s would be suitable for this burner.

  • PDF

Experimental method and evaluation of the calibration capability for the national calibration centers using the platinum resistance temperature sensors (백금저항온도센서를 이용한 국가교정기관의 교정능력 평가 및 실험방법)

  • Gam, Kee-Sool;Yoo, Sung-Ho;Kim, Sung-Min;Lee, In-Sick
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.231-236
    • /
    • 2005
  • Calibration capability was evaluated using the reference-grade platinum resistance thermometer (PRT) in the temperature range of $-50^{\circ}C$ to $250^{\circ}C$ for the national calibration centers. The reference-grade PRT was calibrated at the several fixed points, which was composed by the freezing points of Sn, In, the melting point of Ga and the triple point of water and Hg, before and after the round-robin test (RRT) experiments. The temperature scale of reference-grade PRT was compared to the local standard PRT's using the system of the national calibration centers. $E_{n}$ values was calculated by the temperature difference between the reference-grade PRT and the local standard PRT, and the best measurement capability. Finally, the capability of the national calibration centers was evaluated by the $E_{n}$ values.

A Comparative Study Between Linear Regression and Support Vector Regression Model Based on Environmental Factors of a Smart Bee Farm

  • Rahman, A. B. M. Salman;Lee, MyeongBae;Venkatesan, Saravanakumar;Lim, JongHyun;Shin, ChangSun
    • Smart Media Journal
    • /
    • v.11 no.5
    • /
    • pp.38-47
    • /
    • 2022
  • Honey is one of the most significant ingredients in conventional food production in different regions of the world. Honey is commonly used as an ingredient in ethnic food. Beekeeping is performed in various locations as part of the local food culture and an occupation related to pollinator production. It is important to conduct beekeeping so that it generates food culture and helps regulate the regional environment in an integrated manner in preserving and improving local food culture. This study analyzes different types of environmental factors of a smart bee farm. The major goal of this study is to determine the best prediction model between the linear regression model (LM) and the support vector regression model (SVR) based on the environmental factors of a smart bee farm. The performance of prediction models is measured by R2 value, root mean squared error (RMSE), and mean absolute error (MAE). From all analysis reports, the best prediction model is the support vector regression model (SVR) with a low coefficient of variation, and the R2 values for Farm inside temperature, bee box inside temperature, and Farm inside humidity are 0.97, 0.96, and 0.44.

RESEARCH OF WELDING EFFECT ON STRUCTURAL INTEGRITY AT HIGH TEMPERATURE

  • Tu, Shan-Tung;Yoon, Kee-Bong
    • Proceedings of the KWS Conference
    • /
    • 1998.10a
    • /
    • pp.11-24
    • /
    • 1998
  • The invention of fusion wilding technology has brought on a revolutionary change in manufacturing industry which enables the construction of large scale high temperature plants in chemical, petrochemical and power generation industries. However, among the failure cases of high temperature components, premature failures of weldments have taken a large percentage that indicates the detrimental effect of welding on structural integrity. The accurate prediction of the high temperature behaviour of welded components is thus becoming increasingly important in order to realise an optimised design and maintenance of a plant life. In the present paper, recent research activities on high temperature behaviour of welded structures are briefly summarised. A local deformation measuring technique is proposed to determine the creep properties of weldment constituents. A damage mechanics approach is introduced to study the life reduction and ductility reduction due to the presence of a weld in high temperature structures. Finally, the high temperature creep crack growth in weldments is discussed.

  • PDF