• 제목/요약/키워드: Local Temperature

검색결과 1,925건 처리시간 0.026초

Local bond-slip behavior of fiber reinforced LWAC after exposure to elevated temperatures

  • Tang, Chao-Wei
    • Structural Engineering and Mechanics
    • /
    • 제73권4호
    • /
    • pp.437-445
    • /
    • 2020
  • The microstructure and mechanical properties of concrete will degrade significantly at high temperatures, thus affecting the bond strength between reinforcing steel and surrounding concrete in reinforced concrete members. In this study, the effect of individual and hybrid fiber on the local bond-slip behavior of lightweight aggregate concrete (LWAC) after exposure to elevated temperatures was experimentally investigated. Tests were conducted on local pullout specimens (150 mm cubes) with a reinforcing bar embedded in the center section. The embedment lengths of the pullout specimens were 4.2 times the bar diameter. The parameters investigated included concrete type (control group: ordinary LWAC; experimental group: fiber reinforced LWAC), concrete strength, fiber type, and targeted temperature. The test results showed that for medium-strength LWACs exposed to high temperatures, the use of only steel fibers did not significantly increase the residual bond strength. Moreover, the addition of individual and hybrid fiber had little effect on the residual bond strength of the high-strength LWAC after exposure to a temperature of 800℃.

Statistical Characteristics of Local Circulation Winds Observed using Climate Data in the Complex Terrain of Chilgok, Gyeongbuk

  • Ha-Young Kim;Soo-Jin Park;Hae-Dong Kim
    • 한국환경과학회지
    • /
    • 제32권5호
    • /
    • pp.375-384
    • /
    • 2023
  • Climate data were obtained over an eight-year period (July 2013 to June 2021) using an automatic weather observation system (AWS) installed at the foot of Mt. Geumo in Chilgok, Gyeongbuk. Using climate data, the statistical and meteorological characteristics of the local circulation between the Nakdong River and Mt. Geumo were analyzed. This study is based on automatic weather observation system data for Dongyeong, along with comparative climate data from the Korea Meteorological Administration (Chilgok) and the Gumi meteorological observatory. Over the eight- years, mountain and valley winds have occurred 48 times a year on average, with the highest occurring in May and the weakest winds in June and December. When mountain winds occurred, the temperature in the nearby lowland region more strongly decreased than when valley winds blew. However, the potential to use mountain winds to improve urban thermal environments is limited because mountain winds occur infrequently in summer when a drop in nighttime temperature is required.

Biochemical Characterization of a Psychrophilic Phytase from an Artificially Cultivable Morel Morchella importuna

  • Tan, Hao;Tang, Jie;Li, Xiaolin;Liu, Tianhai;Miao, Renyun;Huang, Zhongqian;Wang, Yong;Gan, Bingcheng;Peng, Weihong
    • Journal of Microbiology and Biotechnology
    • /
    • 제27권12호
    • /
    • pp.2180-2189
    • /
    • 2017
  • Psychrophilic phytases suitable for aquaculture are rare. In this study, a phytase of the histidine acid phosphatase (HAP) family was identified in Morchella importuna, a psychrophilic mushroom. The phytase showed 38% identity with Aspergillus niger PhyB, which was the closest hit. The M. importuna phytase was overexpressed in Pichia pastoris, purified, and characterized. The phytase had an optimum temperature at $25^{\circ}C$, which is the lowest among all the known phytases to our best knowledge. The optimum pH (6.5) is higher than most of the known HAP phytases, which is fit for the weak acidic condition in fish gut. At the optimum pH and temperature, MiPhyA showed the maximum activity level ($2,384.6{\pm}90.4{\mu}mol{\cdot}min^{-1}{\cdot}mg^{-1}$, suggesting that the enzyme possesses a higher activity level over many known phytases at low temperatures. The phytate-degrading efficacy was tested on three common feed materials (soybean meal/rapeseed meal/corn meal) and was compared with the well-known phytases of Escherichia coli and A. niger. When using the same amount of activity units, MiPhyA could yield at least $3{\times}$ more inorganic phosphate than the two reference phytases. When using the same weight of protein, MiPhyA could yield at least $5{\times}$ more inorganic phosphate than the other two. Since it could degrade phytate in feed materials efficiently under low temperature and weak acidic conditions, which are common for aquacultural application, MiPhyA might be a promising candidate as a feed additive enzyme.

Release of Calcein from Temperature-Sensitive Liposomes in a Poly(N-isopropylacrylamide) Hydrogel

  • Han Hee Dong;Kim Tae Woo;Shin Byung Cheol;Choi Ho Suk
    • Macromolecular Research
    • /
    • 제13권1호
    • /
    • pp.54-61
    • /
    • 2005
  • We prepared temperature-sensitive liposomes (TS-liposomes) modified with a thermo sensitive polymer, such as poly(N-isopropylacrylamide) (PNIPAAm), to increase the degree of drug release from liposomes at the hyperthermic temperature. A PNIPAAm hydrogel containing TS-Iiposomes was also prepared to obtain a hydrogel complex at body temperature. In addition, a depot system for local drug delivery using the polymer hydrogel was developed to enhance therapeutic efficacy and prevent severe side effects in the whole body. The PNIPAAm-mod­ified TS-liposome was fixed into the PNIPAAm hydrogel having a high temperature-sensitivity. The release behavior of calcein, a model drug, from TS-liposomes in the PNIPAAm hydrogel was then initiated by external hyperthermia; the results indicated that sustained release as a function of temperature and time was caused by the thermosensitivity of the liposome surface and diffusion of the drug into the PNIPAAm hydrogel. Our results indicated that TS-liposomes in a PNIPAAm hydrogel represented a plausible system for local drug delivery.

토지이용 및 토지피복과 국지온도 간 관계 분석: 미시공간에서의 통합모델 구축을 중심으로 (Analyzing Relationship between the Local Temperature, Land Usage and Land Coverage: Focused on the Integrated Model in the Microspace)

  • 박유나;이건원;정윤남;김세용
    • KIEAE Journal
    • /
    • 제14권5호
    • /
    • pp.123-130
    • /
    • 2014
  • In order for effective heat island reduction policies to be proposed, this research made use of the land usage and land coverage and Temperature of cities, Coordinate axis data within 500 meters of nationwide automatic weather stations (478 points) in order to analyze the correlation of summertime temperatures through multiple regression analysis. This research also developed a model and empirically analyzed the urban heat island reduction effect of factors that affect regional temperatures. Heat islands cause environment deterioration and therefore can harm citizens' health, and also affects the city's metabolism process. Thus in order to restrain regional temperature rises the conclusion was drawn that consideration to increase forest areas on part of land usage planning is needed. Appropriate policy measures to regulate traffic related factors are also needed to restrain regional temperature rises. In order for future heat island reduction this research proposes a way to set up more effective policies and urban sustainability improvement strategies, and is significant in that it makes use of detailed data such as land usage and land coverage, Temperature of cities, Coordinate axis in analyses.

단열재 개선을 통한 PKG-A Water Jet Room 온도저감 연구 (A Study on the Internal Temperature Reduction of PKG-A Water-jet-room by Substituting Heat Insulation Materials)

  • 정영인;최상민
    • 품질경영학회지
    • /
    • 제47권3호
    • /
    • pp.425-435
    • /
    • 2019
  • Purpose: The purpose of this study was to resolve the Naval ship's Local Operation Panel(LOP) malfunction problems which caused by overheating in summer season and dispatching to equatorial regions. Methods: Instead of using dual type heat insulation materials(consist with ceramic wool and glass wool), aerogel heat insulation materials were used for decreasing heat emissions from gas-turbine heat waste steam pipes passing water-jet- room. Experiment and Computational analysis of heat flow were conducted to analyze the internal room temperature changes. Results: The results of this study are as follows; The aerogel heat insulation materials suppress heat emission more efficiently than dual type insulation materials. The cold surface temperature of insulation was far more decreased and internal room, LOP surface temperature also showed significant results too. Conclusion: The substituted heat insulation materials appeared remarkable performance in decreasing room temperature that it could be used for suppressing the LOP overheatings and malfunctions.

원형 실린더 주위의 전도-대류 열전달 (Wall Heat Conduction and Convection Heat Transfer from a Cylinder in Cross Flow)

  • 이상봉;이억수;김시영
    • 한국해양공학회지
    • /
    • 제15권3호
    • /
    • pp.1-8
    • /
    • 2001
  • With uniform heat generation within the wall of the cylinder placed in a cross flow, heat flows by conduction in the circumferential direction due to the asymmetric nature of the fluid flow around the perimeter of the cylinder. The circumferential heat flow affects the wall temperature distribution to such an extent that in some cases significantly different results may be obtained for geometrically similar surfaces. In the present investigation, the effects of circumferential wall heat conduction on local convective heat transfer is investigated for the case of forced convection around horizontal cylinder in cross flow of air. Two-dimensional temperature distribution $T_w$/(${\gamma}$,${\theta}$) is presented through the numerical analysis. The one-dimensional and two-dimensional solutions are in good agreement with experimental results of local heat transfer coefficients.

  • PDF

저온 주사 레이저 및 홀소자 현미경을 이용한 GdBCO와 YBCO 초전도 선재의 국소적 특성 분석 (Analysis of the Local Properties in GdBCO and YBCO Coated Conductors using Low-temperature Scanning Laser and Hall Probe Microscopy)

  • 박상국;이형철
    • Progress in Superconductivity
    • /
    • 제13권3호
    • /
    • pp.169-177
    • /
    • 2012
  • Distribution of the local properties in GdBCO and YBCO coated conductors was investigated using Low-temperature Scanning Laser and Hall Probe Microscopy (LTSLHPM). We prepared GdBCO and YBCO coated conductors to study the spatial distribution of the current density in a single bridge. Inhomogeneity of the ${T_c}^{max}$ in the bridge was analyzed from experimental results of Scanning Laser Microscopy (SLM) near the superconducting transition. The local transport and screening current in the bridge were also investigated using Scanning Hall Probe Microscopy (SHPM). A series of line scans of SLM of the GdBCO and YBCO sample showed that lines with more inhomogeneous distributions of ${\delta}V$ had more inhomogeneous distributions of ${T_c}^{max}$. The defect of the superconducting layer of the GdBCO sample caused by damage to the substrate affected the current flow. And we could analyze the redistribution of the current density using SLM and SHPM.

원통형 축냉조내 구형캡슐들의 축냉에 관한 실험 연구 (Experimental Study on the Cold Storage of Spherical Capsules in the Cylindrical Tank)

  • 조금남;정갑용
    • 대한기계학회논문집
    • /
    • 제19권10호
    • /
    • pp.2647-2656
    • /
    • 1995
  • The present work was performed to axially and radially investigate the local cold storage performance in the cylindrical tank with the spherical capsules inserted n-Tetradecane as a new cold storage material. The local cold storage performance of the capsules in the tank was experimentally investigated for the inlet temperature of -7, -5, -3, 0.deg. C, for the flow rate of 0.95, 1.89, 2.84, 6.00 l/min, and for the diameter ratio of 4.9, 9.0, 13.1. The local cold storage performance in the case of using water applied for the commercial ice-ball system was axially investigated by changing the flow rate only with the inlet temperature of -7.deg. C and the diameter ratio of 9.0 in order to compare with the performance in the case of using n-Tetradecane. For the case of using n-Tetradecane, the difference of cold storage period between the first and the seventh story was increased as the inlet temperature was increased and the flow rate was decreased. The capsules at the center of the tank showed the supercooling and the increased cold storage period compared with the capsules at the wall of the tank due to the small porosity and insufficient cold storage performance at the center of the tank as the diameter ratio is increased. The case using water showed worse cold storage performance due to comparatively large supercooling than the case using n-Tetradecane.

미세 원형 충돌수제트의 부분 대류비등에 있어서 자유표면/잠입 제트의 국소 열전달 특성 (Local Heat Transfer Characteristics in Convective Partial Boiling by Impingement of Free-Surface/Submerged Circular Water Jets)

  • 조형희;우성제;신창환
    • 설비공학논문집
    • /
    • 제14권6호
    • /
    • pp.441-449
    • /
    • 2002
  • Single-phase convection and partial nucleate boiling in free-surface and submerged jet impingements of subcooled water ejected through a 2-mm-diameter circular pipe nozzle were investigated by local measurements. Effects of jet velocity and nozzle-to-imping-ing surface distance as well as heat flux on distributions of wall temperature and heat transfer coefficients were considered. Incipience of boiling began from far downstream in contrast with the cases of the planar water jets of high Reynolds numbers. Heat flux increase and velocity decrease reduced the temperature difference between stagnation and far downstream regions with the increasing influence of boiling in partial boiling regime. The chance in nozzle-to-impinging surface distance from H/d=1 to 12 had a significant effect on heat transfer around the stagnation point of the submerged jet, but not for the free-surface jet. The submerged jet provided the lower cooling performance than the free-surface jet due to the entrainment of the pool fluid of which temperature increased.