• 제목/요약/키워드: Local Temperature

검색결과 1,925건 처리시간 0.03초

Design and control of extractive distillation for the separation of methyl acetate-methanol-water

  • Wang, Honghai;Ji, Pengyu;Cao, Huibin;Su, Weiyi;Li, Chunli
    • Korean Journal of Chemical Engineering
    • /
    • 제35권12호
    • /
    • pp.2336-2347
    • /
    • 2018
  • The azeotrope of methyl acetate methanol and water was isolated using extractive distillation with water as entrainer. The pressure-swing extractive distillation (PSED) process and vapor side-stream distillation column (VSDC) with the rectifier process were designed to separate the methyl acetate, methanol and water mixture. It was revealed that the VSDC with the rectifier process had a reduction in energy consumption than the PSED process. Four control schemes of the two process were investigated: Double temperature control scheme (CS1), $Q_R/F$ feedforward control of reboiler duty scheme for PESD (CS2), $Q_R/F$ feedback control scheme for VSDC (CS3), the feedback control scheme of sensitive plate temperature of side-drawing distillation column to dominate the compressor shaft speed (CS4). Feed flow and composition disturbance were used to evaluate the dynamic performance. As a result, CS4 is a preferable choice for separation of methyl acetate-methanol-water mixture. A control scheme combining the operating parameters of dynamic equipment with the control indicators of static equipment was proposed in this paper. It means using the sensitive plate temperature of side-drawing column to control the compressor shaft speed. This is a new control scheme for extractive distillation.

A STUDY ON EXTRACTING THE SURFACE TEMPERATURE USING THERMAL INFRARED OF ASTER IMAGES IN URBAN AREA

  • Jo Myung-Hee;Kim Hyung-Sub;Kim Sung-Jae;Yu Seong-Ok
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.717-720
    • /
    • 2005
  • Recently as large sized urban development and the city ward drifting of population are caused, the urban surface temperature is raised very seriously and rapidly. These artificial developments have destroyed the inner and outer landscapes such as topography and have changed complex local climate such as a sudden rise in temperature, the change of wind field and air pollution. In order to clarify this problem visually, the studies on extracting the thermal infrared and the characteristic analysis of local climate in urban area had been performed by using the sixth band of Landsat TM and ETM+. However, there is a need to alternate Landsat TM and ETM+ because these satellite images are not applied any more. Therefore, in this paper it is proposed to use 2 Aster image (2004.4.17 daily 2b03, 2004.10.10 night 2b03) of EOS AM and to extract the surface temperature. Also, the pattern of surface temperature in urban area and the application possibility in local climate study are proposed by verifying the correlation with A WS data. Also, IKONOS image was used to figure out the artificial development area in visual.

  • PDF

더운 환경에서 산업용 각반 착용 시 인체생리반응 (Physiological Responses of Wearing Industrial Gaiters in a Hot Environment)

  • 최정화;박준회
    • 한국의류학회지
    • /
    • 제32권7호
    • /
    • pp.1129-1136
    • /
    • 2008
  • The gaiter is one of the personal protective equipments worn in various industrial sites. This study was performed on humans to investigate the physiological strain of wearing gaiters and to compare control gaiters that are currently on the market and new gaiters that are developed for alleviating heat stress. Experiments were conducted in a climatic chamber of WBGT $30.0\pm0.7^{\circ}C$ under five differed experimental conditions: None, Control A, Control B, New A, New B. The results were as follows. The temperature inside gaiters was significantly lower in both New A and New B than in both Control A and Control B and the difference between news and controls was 1$^{\circ}C$ (p<.01). The humidity inside gaiters in both New A and New B were higher than that in Control A, and lower than that in Control B (p<.01). The outermost surface temperature of the gaiter was the lowest in None and it increased in the following order: New B < New A < Control A < Control B. Mean skin temperature was higher by 0.14$^{\circ}C$ in wearing gaiters than in no gaiters. Skin temperatures in lower body were lower in Control than in New and skin temperature in upper body were higher in Control than in New (p<.01). Local sweat rate, total weight loss and subjective sensations did not show a significant difference according to the gaiters. It was concluded that wearing gaiters affected distribution of skin temperature and local sweat rate.

Characterization of Thin Liquid Films Using Molecular Dynamics Simulation

  • Lee, Jaeil;Park, Seungho;Ohmyoung Kwon;Park, Young-Ki;Lee, Joon-Sik
    • Journal of Mechanical Science and Technology
    • /
    • 제16권11호
    • /
    • pp.1477-1484
    • /
    • 2002
  • Various characteristics of a thin liquid film in its vapor-phase are investigated using the molecular dynamics technique. Local distributions of the temperature, density, normal and tangential pressure components, and stress are calculated for various film thicknesses and temperature levels. Distributions of local stresses change considerably with respect to film thicknesses, and interracial regions on both sides of the film start to overlap with each other as the film becomes thinner. Integration of the local stresses, i.e., the surface tension, however, does not vary much regardless of the interfacial overlap. The minimum thickness of a liquid film before rupturing is estimated with respect to the calculation domain sizes and is compared with a simple theoretical relation.

고분자 전해질 연료전지의 전류밀도와 국소 함수량 관찰 (Observation of local water content and current density in the PEMFC system)

  • 고동수;문철언;최경민;김덕줄;정지환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2008
  • The local water contents and water transfer characteristics in the PEMFC system were investigated by numerical simulations and experiments. The performance of a lab-scale PEMFC is measured for fully humidified gases conditions and non-humidified ones. In order to observe the local water contents and water transfer characteristics inside PEMFC, the numerical simulation using CFD module on STAR-CD(es-pemfc) were conducted. The results show that the water content was increased as increasing current density, whereas it was decreased in high current density region. Then there was close correlation between high water content and internal temperature inside of MEA, and high current density was observed when internal temperature was dramatically increased.

  • PDF

원형이중관내의 난류유동의 열전달 특성에 관한 실험적 연구 (An Experimental Study on Heat Transfer Characteristics with Turbulent Flow in a Cylindrical Annuli)

  • 장태현;이권수
    • 한국산업융합학회 논문집
    • /
    • 제5권3호
    • /
    • pp.193-200
    • /
    • 2002
  • An experimental study was performed to study heat transfer characteristics for turbulent flow in an axisymmetric annuli. The air flow temperature and the local Nusselt number in turbulent flow were measured or calculated for Re=30,000, 40,000, 50,000, 60,000, 70,000 and 80,000. The local Nusselts number were compared to that obtained from Dittus-Boelter equation with turbulent flow. The results show that the flow enhances the heat transfer in the initial and exit portion of the test tube.

  • PDF

수평평활관내의 비공비 혼합냉매의 응축에 대한 예측모델 (A Prediction Model for Condensation of Zeotropic Refrigerant Mixtures Inside a Horizontal Smooth Tube)

  • 이상무;박병덕
    • 설비공학논문집
    • /
    • 제13권4호
    • /
    • pp.262-270
    • /
    • 2001
  • This paper deals with a prediction method for the condensation of ternary refrigerant mixture inside a horizontal smooth tube. Based on some reliable assumptions, the governing equations for the local heat and mass transfer characteristics are derived, and the prediction for the condensation of ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a, including R407C, is carried out. The local values of vapor quality, thermodynamic states at bulk vapor, vapor-liquid interface and bulk liquid, mass flux etc. are obtained for a constant wall temperature and a constant wall heat flux conditions, and the effects of the composition of HFC32/HFC125/HFC134a on heat transfer characteristics are examined. The prediction result is also compared with experimental data for condensation of ternary refrigerant mixtures. The predicted wall temperature distribution has a similar trend with experimental data but the predicted local heat transfer coefficients are 20-30% higher than the experimental data.

  • PDF

Forced Convection Boiling Heat Transfer from a Horizontal Cylinder to Subcooled Water

  • Lee, Sung-Hong;Lee, Euk-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.79-90
    • /
    • 1999
  • This investigation presents the experimental results of forced convection boiling heat transfer around a circular, electrically heated horizontal cylinder to subcooled water in cross flow. In these experiments, the following primary variables were included: heat flux, flow velocity, pressure and degree of subcooling at inlet. Local surface temperatures were measured at nine peripheral positions. Local surface temperature distributions are classified into four categories depending on the supplied heat flux. The effects of the boiling curve depending on the fluid velocity, degree of subcooling at inlet and pressure are presented.

  • PDF

지리산 개서어나무림에서의 12년간 지역기후의 변화에 따른 연간 종자생산량의 변동 (Twelve Years Changes in Local climate Factors and Annual fluctuations of Seed Production of the Carpinus tschonoskii Forest in Mt. jiri in Southern Korea)

  • 임영득;홍선기
    • The Korean Journal of Ecology
    • /
    • 제21권6호
    • /
    • pp.809-814
    • /
    • 1998
  • Changes of annual seed production related to climate change were studied for 12 years in Piagol, a riparian valley in Mt. Jiri. Sixty-four seed traps (sized 0.5 ${\times}$ 0.5 $m^{2}$) were set up on the forest floor of surveyed area. Seeds were collected from these traps at an interval of 15 days from September to November since 1984. Vegetation of the study area was mainly consisted of the naturally regenerated Carpinus tschonoskii in the tree layer. Acer mono, Quercus serrata, Carpinus laxiflora and Symplocos chinensis also appeared in the same layer. Maximum production occurred in 1984 and 1994. As a result of comparing seed production with local climate factors for 12 years, seed productivity and the year of maximum production of Carpinus forest were merely related with precipitation, air temperature and duration of sunshine among local climate factors. Duration of sunshine was, however, not contributed to periodically high productivity of seed of riparian valley carpinus forest.

  • PDF

An Experimental Study on Swirling Flow with Heat Transfer in the Horizontal Circular Annuli

  • Chang Tae-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권3호
    • /
    • pp.260-274
    • /
    • 2005
  • An experimental investigation was performed to study the characteristics of turbulent swirling flow in the cylindrical annuli. The swirl angle measurements were performed by flow visualization technique using smoke and dye liquid. By using the particle image velocimetry method. this study has found the time-mean velocity distribution and turbulent intensity with swirl for Re=20,000. 30.000. 50.000. and 70,000 along longitudinal sections. The results appear to be physically reasonable. Other experimental study was performed to investigate heat transfer characteristics of turbulent swirling air flow in axisymmetric annuli. The static pressure. the local air flow temperature, and the wall temperature with decaying swirl were measured by using thermocouples and the friction factor and the local Nusselt number were calculated for Re=30,000. 50,000 and 70000. The local Nusselt number was compared with that obtained from the Dittus-Boelter equation with swirl and without swirl, respectively. The results showed that the swirl enhances the heat transfer at the inlet and the outlet of the test tube.