• Title/Summary/Keyword: Load.

Search Result 36,288, Processing Time 0.065 seconds

Bond strength of fiber reinforced composite after repair (섬유 강화 컴포지트의 수리 후 접합 강도)

  • Kim, Min-Jung;Kim, Kyung-Ho;Choy, Kwang-Chul
    • The korean journal of orthodontics
    • /
    • v.36 no.3 s.116
    • /
    • pp.188-197
    • /
    • 2006
  • Fiber reinforced composite (FRC) is usually used as a connector joining a few teeth into one unit in orthodontics. However, fracture often occurs during the two to three years of the orthodontic treatment period due to repeated occlusal loading or water sorption in the oral environment. We simulated the repair by overlapping and attaching portions of two FRC strips in the middle and performed a three-point bending test to investigate the changes of the repair strength among the different FRC groups. The specimens were grouped according to the overlapping lengths of the two FRC strips, which were 1, 2, 3 and 4 mm (group E1, E2, E3 and E4, respectively) and the control group consisted of unrepaired, intact FRC strips. Each group consisted of 6 specimens and were cured with a light emitting diode curing unit. Group E4 showed the highest maximum loads of 2.67 N, then the control group (2.39 N), group E3 (2.35 N), E2 (2.10 N), and E1 (1.75 N) in decreasing order. Group E4 also showed the highest stiffness, which was 2.32 N/mm, however, the stiffness of group E3 (2.06N/mm) was higher than that of the control group (1.88 N/mm). According to the visual examination, the specimens tended to be bent rather than being fractured into two pieces with an increased length of overlapping portions. The above results suggest that a minimum overlapping length of 3 mm was necessary to obtain an adequate repair of a 10 mm length of FRC connector. In addition, the critical section adjacent to the joint area, where the thickness decreased abruptly, should be reinforced with flowable resin to minimize the bending tendency.

Limitations on Exclusive Rights of Authors for Library Reprography : A Comparative Examination of the Draft Revision of Korean Copyright Law with the New American Copyright Act of 1976 (저작권법에 준한 도서관봉사에 관한 연구 -미국과 한국의 저자재산권의 제한규정을 중시으로-)

  • 김향신
    • Journal of Korean Library and Information Science Society
    • /
    • v.11
    • /
    • pp.69-99
    • /
    • 1984
  • A dramatic development in the new technology of copying materials has presented us with massive problems on reconciling the conflicts between copyright owners and potential users of copyrighted materials. The adaptation to this changing condition led some countries to revise their copyright laws such as in the U. S. in 1976 and in Korea in 1984 for merging with the international or universal copyright conventions in the future. Copyright defined as exclusive rights given to copyright owners aims to secure a fair return for an author's creative labor and to stimulate artistic creativity for the general public good. The exclusive rights on copyrightable matters, generally for reproduction, preparation of derivative works, public distribution, public performance, and public display, are limited by fair use for scholarship and criticism and by library reproduction for its preservation and interlibrary loan. These limitations on the exclusive rights are concerned with all aspects of library services and cause a great burden on librarian's daily duty to provide balance between the rights of creators and the needs of library patrons. The fair use as one of the limitations on it has been coupled with enormous growth of a new technology and extended from xerography to online database systems. The implementation of the fair use and library reprography in Korean law to the local practices is examined on the basis of the new American copyright act of 1976. Under the draft revision of Korean law, librarians will face many potential problems as summarized below. 1. Because the new provision of 'life time plus 50 years' will tie up substantial bodies of material longer than the old law, until that date librarians would need permissions from the owners and should pay attention to the author's death date. 2. Because the copyright can be sold, distributed, given to the heirs, donated, as a whole or a part, librarians should chase down the heirs and other second owners. In case of a derivative work, this is a real problem. 3. Since a work has its protection from the moment of its creation, the coverage of copyrightable matter would be extended to the published or the unpublished works and librarian's work load would be heavier. Without copyright registration, no one can be certain that a work is in the public domain. Therefore, librarians will need to check with an authority. 4. For implementation of limitations on exclusive rights, fair use and library reproduction for interlibrary loan, there can be no substantial aggregate use and there can be no systematic distribution of multicopies. Therefore, librarians should not substitute reproductions for subscriptions or purchases. 5. For the interlibrary loan by photocopying, librarians should understand the procedure of royalty payment. 6. Compulsory licenses should be understood by librarians. 7. Because the draft revision of Korean law is a reciprocal treaty, librarians should take care of other countries' copyright law to protect foreign authors from Korean law. In order to solve the above problems, some suggestions are presented below. 1. That copyright clearinghouse or central agency as a centralized royalty payment mechanism be established. 2. That the Korean Library Association establish a committee on copyright. 3. That the Korean Library Association propose guidelines for each occasion, e.g. for interlibrary loan, books and periodicals and music, etc. 4. That the Korean government establish a copyright office or an official organization for copyright control other than the copyright committee already organized by the government. 5. That the Korean Library Association establish educational programs on copyright for librarians through seminars or articles written in its magazines. 6. That individual libraries provide librarian's copyright kits. 7. That school libraries distribute subject bibliographies on copyright law to teachers. However, librarians should keep in mind that limitations on exclusive rights are not for an exemption from library reprography but as a convenient access to library resources.

  • PDF

Heating Performance of Hot Water Supplying System in Greenhouse (온수배관을 이용한 온실의 난방성능)

  • Yoon, Yong-Cheol;Shin, Yik-Soo;Kim, Hyeon-Tae;Bae, Seoung-Beom;Choi, Jin-Sik;Suh, Won-Myung
    • Journal of Bio-Environment Control
    • /
    • v.21 no.2
    • /
    • pp.79-87
    • /
    • 2012
  • This research was conducted to obtain basic data with regard to the heating performance that would be produced by installing an aluminum hot water pipe inside the greenhouse with the goal of reducing the heating energy in greenhouse. The research results are summarized as follows. The degree of difference in relation to the temperature by height within the greenhouse during the entire experiment was significant - within the range of 4.0~$7.0^{\circ}C$. The temperature difference between incoming and outgoing water was about $3.3^{\circ}C$ greater when FCU was activated compared to when it was not activated. Meanwhile, the amount of energy consumed increased about 36.2~40.1%. The amount of pyrexia per hour also increased by 44.6~52.0%. During the experiment period, circulated flux was within the range of 0.48~$0.49L{\cdot}s^{-1}$ while average fluid speed was 1.53~$1.56m{\cdot}s^{-1}$. The average temperature difference between incoming and outgoing water was 6.24~$11.50^{\circ}C$. The amount of heating value by each set temperature within the minimum outdoor temperature range of -14.0~$-0.6^{\circ}C$ was 135,930~307,150 kcal, and the range was within the 9,610~$19,630kcal{\cdot}h^{-1}$ per hour. This demonstrated that about 23~53% heating energy of the maximum heating load could be supplied. Total radiating value and amount of energy consumed were 2,548,306 kcal and 3,075.7 kWh, respectively. When heating takes place using oil, which is a fossil fuel, the total amount of light oil consumed was 281.6 L while the cost was 321,000 won. When the electricity cost for farms is applied, the total cost was about 110,730 won, which is about 33.5% of the cost required compared to oil consumption. The temperature at in the experiment area was about 8.3~$14.6^{\circ}C$ higher compared to that of the control area.

Channel Changes and Effect of Flow Pulses on Hydraulic Geometry Downstream of the Hapcheon Dam (합천댐 하류 하천지형 변화 예측 및 흐름파가 수리기하 변화에 미치는 영향)

  • Shin, Young-Ho;Julien, Pierre Y.
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.7
    • /
    • pp.579-589
    • /
    • 2009
  • Hwang River in South Korea, has experienced channel adjustments due to dam construction. Hapcheon main dam and re-regulation dam. The reach below the re-regulation dam (45 km long) changed in flow regime, channel width, bed material distribution, vegetation expansion, and island formation after dam construction. The re-regulation dam dramatically reduced annual peak flow from 654.7 $m^3$/s to 126.3 $m^3$/s and trapped the annual 591 thousand $m^3$ of sediment load formerly delivered from the upper watershed since the completion of the dam in 1989. An analysis of a time series of aerial photographs taken in 1982, 1993, and 2004 showed that non-vegetated active channel width narrowed an average of 152 m (47% of 1982) and non-vegetated active channel area decreased an average of 6.6 km2 (44% of 1982) between 1982 and 2004, with most narrowing and decreasing occurring after dam construction. The effects of daily pulses of water from peak hydropower generation and sudden sluice gate operations are investigated downstream of Hapcheon Dam in South Korea. The study reach is 45 km long from the Hapcheon re-regulation Dam to the confluence with the Nakdong River. An analysis of a time series of aerial photographs taken in 1982, 1993, and 2004 showed that the non-vegetated active channel width narrowed an average of 152 m (47% reduction since 1982). The non-vegetated active channel area also decreased an average of 6.6 $km^2$ (44% reduction since 1982) between 1982 and 2004, with most changes occurring after dam construction. The average median bed material size increased from 1.07 mm in 1983 to 5.72 mm in 2003, and the bed slope of the reach decreased from 0.000943 in 1983 to 0.000847 in 2003. The riverbed vertical degradation is approximately 2.6 m for a distance of 20 km below the re-regulation dam. It is expected from the result of the unsteady sediment transport numerical model (GSTAR-1D) steady simulations that the thalweg elevation will reach a stable condition around 2020. The model also confirms the theoretical prediction that sediment transport rates from daily pulses and flood peaks are 21 % and 15 % higher than their respective averages.

Power Generation Performance Evaluation according to the Vehicle Running on the Hybrid Energy Harvesting Block (하이브리드 에너지하베스팅 블록의 차량주행 발전성능 평가)

  • Kim, Hyo-Jin;Park, Ji-Young;Jin, Kyu-Nam;Noh, Myung-Hyun
    • Land and Housing Review
    • /
    • v.7 no.4
    • /
    • pp.307-314
    • /
    • 2016
  • Energy harvesting technique is to utilize energy that is always present but wasted. In this study, we have developed the energy harvester of the hybrid method utilizing both vibration and pressure of the vehicle traveling a road or parking lot. In the previous study, we have developed a prototype energy harvester, improved hybrid energy harvester, and developed a final product that offers improved performance in the hybrid module. The results were published in the previous paper. In this study, we installed the finally developed hybrid module in the actual parking lot. And we measured the power generation performance due to pressure and vibration, and the running speed of the vehicle when the vehicle is traveling. And we compared the results with those obtained in laboratory conditions. In a previous study performed in laboratory conditions the maximum power of the energy block was 1.066W when one single time of vibration, and 1.830W when succession with 5 times. On the other hand, in this study, we obtained the average power output of 0.310W when the vehicle is running at an average 5 km/h, 0.670W when at an average 10 km/h, and 1.250W when at an average 20 km/h, and 2.160W when at an average 5 km/h. That is, the higher the running speed of the vehicle has increased power generation performance. However, when compared to laboratory conditions, the power generation performance of the energy block in driving speed by 20km/h was lower than those in laboratory conditions. In addition, when compared to one time of vibration of laboratory conditions, power generation performance was higher when the running speed 20km/h or more and when five consecutive times in laboratory conditions, it was higher when the running speed 30km/h or more. It could be caused by a difference of load conditions between the laboratory and the actual vehicle. Thus, applying the energy block on the road would be more effective than that on the parking lot.

Water quality prediction of inflow of the Yongdam Dam basin and its reservoir using SWAT and CE-QUAL-W2 models in series to climate change scenarios (SWAT 및 CE-QUAL-W2 모델을 연계 활용한 기후변화 시나리오에 따른 용담댐 유입수 및 호내 수질 변화 예측)

  • Park, Jongtae;Jang, Yujin;Seo, Dongil
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.10
    • /
    • pp.703-714
    • /
    • 2017
  • This paper analyzes the impact of two climate change scenarios on flow rate and water quality of the Yongdam Dam and its basin using CE-QUAL-W2 and SWAT, respectively. Under RCP 4.5 and RCP 8.5 scenarios by IPCC, simulations were performed for 2016~2095, and the results were rearranged into three separate periods; 2016~2035, 2036~2065 and 2066~2095. Also, the result of each year was divided as dry season (May~Oct) and wet season (Nov~Apr) to account for rainfall effect. For total simulation period, arithmetic average of flow rate and TSS (Total Suspended Solid) and TP (Total Phosphorus) were greater for RCP 4.5 than those of RCP 8.5, whereas TN (Total Nitrogen) showed contrary results. However, when averaged within three periods and rainfall conditions the tendencies were different from each other. As the scenarios went on, the number of rainfall days has decreased and the rainfall intensities have increased. These resulted in waste load discharge from the basin being decreased during the dry period and it being increased in the wet period. The results of SWAT model were used as boundary conditions of CE-QUAL-W2 model to predict water level and water quality changes in the Yongdam Dam. TSS and TP tend to increase during summer periods when rainfalls are higher, while TN shows the opposite pattern due to its weak absorption to particulate materials. Therefore, the climate change impact must be carefully analyzed when temporal and spatial conditions of study area are considered, and water quantity and water quality management alternatives must be case specific.

Location Service Modeling of Distributed GIS for Replication Geospatial Information Object Management (중복 지리정보 객체 관리를 위한 분산 지리정보 시스템의 위치 서비스 모델링)

  • Jeong, Chang-Won;Lee, Won-Jung;Lee, Jae-Wan;Joo, Su-Chong
    • The KIPS Transactions:PartD
    • /
    • v.13D no.7 s.110
    • /
    • pp.985-996
    • /
    • 2006
  • As the internet technologies develop, the geographic information system environment is changing to the web-based service. Since geospatial information of the existing Web-GIS services were developed independently, there is no interoperability to support diverse map formats. In spite of the same geospatial information object it can be used for various proposes that is duplicated in GIS separately. It needs intelligent strategies for optimal replica selection, which is identification of replication geospatial information objects. And for management of replication objects, OMG, GLOBE and GRID computing suggested related frameworks. But these researches are not thorough going enough in case of geospatial information object. This paper presents a model of location service, which is supported for optimal selection among replication and management of replication objects. It is consist of tree main services. The first is binding service which can save names and properties of object defined by users according to service offers and enable clients to search them on the service of offers. The second is location service which can manage location information with contact records. And obtains performance information by the Load Sharing Facility on system independently with contact address. The third is intelligent selection service which can obtain basic/performance information from the binding service/location service and provide both faster access and better performance characteristics by rules as intelligent model based on rough sets. For the validity of location service model, this research presents the processes of location service execution with Graphic User Interface.

Changes of Heart Rate During Marathon Running (장거리 (마라톤)선수에서의 전 경기중 심박동수의 변화)

  • Kim, In-Kyo;Lee, Jung-Woo;Hah, Jong-Sik;Ryu, Yun-Hee;Choi, Jung-Ok;Kim, Ki-Ho
    • The Korean Journal of Physiology
    • /
    • v.13 no.1_2
    • /
    • pp.1-12
    • /
    • 1979
  • To evaluate the present status of physical fittness of Korean long distance runners, body fat, pulmonary functions, maximal oxygen intake and oxygen debt were measured in 5 elite marathoners (A group), 6 college student runners (B group) and 3 middle school student runners (C group). After laboratory tests, full course marathon running was performed in 2 elite marathoners during which their heart rates were monitored continuously. The results are summerized as follows: 1) Total body fat in all three groups are in the range of 13-15% of their body weight. 2) In all three groups, average values of various pulmonary functions were within the normal limits, but those of tidal volume were higher and respiratory rate were lower in comparison to normal values. These phenomena may represent respiratory adaptations against training. The average resting oxygen consumptions in A,B and C were $322{\pm}23$, $278{\pm}14$ and $287{\pm}16$m1/min, respectively. 3) In all three groups, resting blood pressures were in the normal range, but the resting heart rate was slightly lower in groups A $(56{\pm}3\;beats/min)$ and B $(64{\pm}2\;beats/min)$ and higher in group C $(82{\pm}9\;beats/min)$ in comparison to normal values. These changes in cardiovascular functions in marathoners may also represent adaptive phenomena. 4) During treadmill running the minute ventilation and oxygen consumption of the runners increased lineally with work load in all three groups. When the oxygen consumption was related to heart rate, it appeared to be a exponential function of the heart rate in all three groups. 5) The average maximal heart rates during maximal work were $196{\pm}3$, $191{\pm}3$ and $196{\pm}5\;beats/min$ for groups A,B and C, respectively. Maximal oxygen intakes were $84.2{\pm}3.3\;ml/min/kg$ in group A, $65.2{\pm}1.1\;ml/min/kg$ in group B and $58.7{\pm}0.4\;ml/min/kg$ in group C. 6) In all three groups, oxygen debts and the rates of recovery of heart rate after treadmill running were lower than those of long ditsance runners reported previously. 7) The 40 km running time in 2 elite marathoners was recorded to be $2^{\circ}42'25'$, and their mean speed was 243 m/min (ranged 218 to 274 m/min). The heart rate appeared to increase lineally with running speed, and the total energy expenditure during 40 km running was approximately 1360.2 Calories. From these it can be speculated that if their heart rates were maintained at 166 beats/min during the full course of marathon running, their records would be arround $2^{\circ}15'$. Based on these results, we may suspect that a successful long distance running is, in part, dependent on the economical utilization of one's aerobic capacity.

  • PDF

Material Characteristics and Deterioration Assessment of the Stone Buddhas and Shrine in Unjusa Temple, Hwasun, Korea (화순 운주사 석조불감의 재질특성과 풍화훼손도 평가)

  • Park, Sung-Mi;Lee, Myeong-Seong;Choi, Seok-Won;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.24
    • /
    • pp.23-36
    • /
    • 2008
  • The stone Buddhas and Shrine of Unjusa temple (Korea Treasure No. 797) in Hwasun formed in Koryo Dynasty are unique style which the Buddha faces each other the back parts of south and north within the stone Shrine. The stone Buddhas and Shrine are highly evaluated in historical, artistic and academic respects. But, the stone properties have been exposed in the open system various aspects of degradations weathered for a long time without specific protective facilities. The rock materials of the stone Buddhas and Shrine are about 47 blocks, and total press load is about 56.6 metric ton. The host rocks composed mainly of white grey hyaline lithic tuff and rhyolitic tuff breccia. In addition, biotite granite used as part during the restoration works. The chemical index of alteration for host tuffaceous rocks and the replacement granites range from 52.1 to 59.4 and 50.0 to 51.0, respectively. Weathering types for the stone Buddhas and Shrine were largely divided with physical, chemical and biological weathering to make a synthetic deterioration map according to aspects of damage, and estimate share as compared with surface area. Whole deterioration degrees are represented that physical weathering appeared exfoliation. Chemical weathering is black coloration and biological weathering of grey lichen, which show each lighly deterioration degrees. According to deterioration degree by direction of stone Buddhas and Shrine, physical weathering mostly appeared by 39.1% on the sorthern part, and chemical weathering is 61.2% high share on the western part. Biological weathering showed 38.3% the largest distribution on the southern part. Therefore, it is necessary to try hardening for the parts with serious cracks or exfoliations, remove secondary contaminants and organisms through regular cleaning. Also necessary to make a plan to remove moisture of the ground which causes weathering, and estimate that need established and scientific processing through clinical demonstration of conservation plan that chooses suitable treatment.

  • PDF

Comparison of Construction Costs for Bridge Foundation with Optimization of Steel and PHC Embedded Piles (강관 및 PHC 매입말뚝의 최적화에 따른 교량기초의 공사비 비교)

  • Yun, Jung-Mann;Yea, Geu-Guwen;Kim, Hong-Yeon;Kim, Dong-Min;Kim, Soo-Lo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.4
    • /
    • pp.71-78
    • /
    • 2016
  • In this study, execution costs of the foundation system are compared with PHC and steel pile in the same soil layers and load condition. Steel piles installed on the thin weathered rock are reduced as 12.5% in comparison with the number of PHC piles. Steel piles installed on the soft rock through weathered rock with 1.7m of thickness reduce the number of piles as 35.7% (STK 400) and 46.4% (STK 490), respectively, in comparison with PHC piles installed on the weathered rock. Also, they reduce the number of piles as 26.5% (STK 400) and 38.8% (STK 490), respectively, in comparison with steel piles (STK 400) installed on the weathered rock. When the thickness of footings is constant, steel piles installed on the soft rock may reduce the area of footings up to 12.2% (STK 400) and 45.4% (STK 490), respectively, in comparison with PHC piles installed on the weathered rock. Total cost of foundation system installed on the soft rock with steel piles (STK 400) increases as 12%, whereas in case of replaced with steel piles (STK 490), it reduces as 16% in comparison with PHC piles installed on the weathered rock. This is because the cost reduction due to the number of piles and footing area is more effective despite high cost of steel piles (STK 490). When the thickness of weathered rock is less than 5m, installing steel piles (STK 490) on the soft rock through it is more economic in comparison with installing PHC piles on the weathered rock.