• Title/Summary/Keyword: Load-pull

Search Result 272, Processing Time 0.036 seconds

Pull-out Behaviors of Headed Bars with Different Details of Head Plates (Head 플레이트 상세에 따른 Headed Bars의 인발거동에 관한 연구)

  • Park, Hyun-Gyoo;Yoon, Young-Soo;Ryoo, Young-Sup;Lee, Man-Seop
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.2 s.5
    • /
    • pp.95-104
    • /
    • 2002
  • This paper presents the pull-out failure mode on Headed Bars and prediction of tensile capacity, as governed by concrete cone failure. 17 different plate types, three different concrete strengths and three different welding types of specimens were simulated. Test variables are the reinforcing bar diameters connected to headed plate (e.g., 16mm, 19mm and 22mm), the head plate shapes (e.g., circular, square, rectangular), the dimensions of head plates (e.g., area and thickness), the types of welding scheme for connection of reinforcing bars and head plates (e.g., general welding and friction welding). Headed Bars were manufactured in different areas, which shape and thickness are based on ASTM 970-98. Calculation of Embedment length in concrete is based on CSA 23.3-94, and static tensile load was applied. Pullout capacities tested were compared to the values determined using current design methods such as ACI-349 and CCD method. If compare experiment results and existings, Headed bar expressed high strength and bigger breakdown radious than standard by wide plate area and anomaly reinforcing rod unlike anchor.

Experimental Study on Bond Strength of AFRP Rebar in Normal Strength Concrete (AFRP 보강근의 부착강도에 대한 실험적 연구)

  • Choi, June-Ho;Park, Kyung-Chan;Lee, Young-Hak;Kim, Hee-Cheul;Lee, Jae-Sam
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.9-16
    • /
    • 2009
  • For reinforced concrete members, bond strength is one of the important factors between the two materials: the concrete and the reinforcing element. The bond strength of Aramid Fiber Reinforced Polymer (AFRP) rebar was tested using the pull-out method. Presented were comparison results of the bond strength between AFRP rebar and deformed steel bars from the test. Embedded lengths and diameters of the rebar were taken into account as parameters. The bond stress-slip responses and failure modes of AFRP rebar were evaluated. It was found that the bond stress-slip responses of AFRP rebar were similar to those of deformed steel bars. As the diameter of rebar increased, the pull-out load increased. In addition, it was shown that the bond strength of an AFRP rebar was approximately 54% compared with that of a deformed steel bar.

Characteristics of Soil-Nailing Applied to Extension-Grouting Method (확장그라우팅 공법이 적용된 쏘일네일링의 거동특성)

  • Lee, Hyoungkyu;Lee, In
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.3
    • /
    • pp.53-62
    • /
    • 2010
  • In the early 1990s, it was first introduced the soil nailing method for the slope stability and ground excavation and widely used as method of reinforcement. Also the application of soil nailing has been improved and developed. Most recently used for grout soil nailing greatly improve the methods and techniques for self-improvement techniques are classified as soil nailing. As the representative for the grout pressure method to improve the join method pressure grouting and improved method for the self-drilled soil nailing, removable soil nailing, extension grout method. Three dimensional finite difference analysis was used to evaluate characteristics of pull-out behavior of extension grout method. In this paper, it was described a characteristics of pull-out behavior of soil nailing with extension grout method through the result of numerical method.

Three-dimensional numerical analysis of nonlinear phenomena of the tensile resistance of suction caissons

  • Azam, Arefi;Pooria, Ahad;Mehdi, Bayat;Mohammad, Silani
    • Geomechanics and Engineering
    • /
    • v.32 no.3
    • /
    • pp.255-270
    • /
    • 2023
  • One of the main parameters that affect the design of suction caisson-supported offshore structures is uplift behavior. Pull-out of suction caissons is profoundly utilized as the offshore wind turbine foundations accompany by a tensile resistance that is a function of a complex interaction between the caisson dimensions, geometry, wall roughness, soil type, load history, pull-out rate, and many other parameters. In this paper, a parametric study using a 3-D finite element model (FEM) of a single offshore suction caisson (SOSC) surrounded by saturated soil is performed to examine the effect of some key factors on the tensile resistance of the suction bucket foundation. Among the aforementioned parameters, caisson geometry and uplift loading as well as the difference between the tensile resistance and suction pressure on the behavior of the soil-foundation system including tensile capacity are investigated. For this purpose, a full model including 3-D suction caisson, soil, and soil-structure interaction (SSI) is developed in Abaqus based on the u-p formulation accounting for soil displacement (u) and pore pressure, P.The dynamic responses of foundations are compared and validated with the known results from the literature. The paper has focused on the effect of geometry change of 3-D SOSC to present the soil-structure interaction and the tensile capacity. Different 3-D caisson models such as triangular, pentagonal, hexagonal, and octagonal are employed. It is observed that regardless of the caisson geometry, by increasing the uplift loading rate, the tensile resistance increases. More specifically, it is found that the resistance to pull-out of the cylinder is higher than the other geometries and this geometry is the optimum one for designing caissons.

Experimental and numerical study on the failure of sandwich T-joints under pull-off loading

  • Nguyen, Khanh-Hung;Park, Yong-Bin;Kweon, Jin-Hwe;Choi, Jin-Ho;Shul, Chang-Won;Yang, Myung-Seog;Jun, Seung-Moon
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.2
    • /
    • pp.229-237
    • /
    • 2012
  • In this study, the failure mechanism of sandwich-to-laminate T-joints under pull-off loading was investigated by experiment and the finite element method. A total of 26 T-joint specimens were manufactured and tested in order to investigate the effects of both adhesive thickness (0.4, 2.0, and 4.0 mm) and environmental conditions on the failure of the joints. The results showed that failure occurred mainly as intralaminar failure in the first layer of the sandwich face, which was contacted to the paste adhesive. The failure load did not significantly change with increasing adhesive thickness in both RTD (Room Temperature and Dry) and ETW (Elevated Temperature and Wet) conditions. In the case of ETW conditions, however, the failure load increased slightly with an increase in adhesive thickness. The joints tested in ETW conditions had higher failure loads than those tested in RTD conditions. In addition to the experiment, a finite element analysis was also conducted to investigate the failure of the joint. The stress inside the first ply of the sandwich face was of interest because during the experiment, failure always occurred there. The analysis results showed good agreement with the trend of experimental results, except for the case of the smallest adhesive thickness. The highest stress was predicted in the regions where initial failure was observed in the experiment. The maximum stress was almost constant when the adhesive thickness was beyond 2 mm.

Design of High-Reliability Differential Paired eFuse OTP Memory for Power ICs (Power IC용 고신뢰성 Differential Paired eFuse OTP 메모리 설계)

  • Park, Young-Bae;Jin, Li-Yan;Choi, In-Hwa;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.2
    • /
    • pp.405-413
    • /
    • 2013
  • In this paper, a high-reliability differential paired 24-bit eFuse OTP memory with program-verify-read mode for PMICs is designed. In the proposed program-verify-read mode, the eFuse OTP memory can do a sensing margin test with a variable pull-up load in consideration of programmed eFuse resistance variation and can output a comparison result through a PFb (pass fail bar) pin by comparing a programmed datum with its read one. It is verified by simulation results that the sensing resistance is lower with $4k{\Omega}$ in case of the designed differential paired eFuse OTP memory than $50k{\Omega}$ in case of its dual-port eFuse OTP memory.

Design of a RF power amplifier using distributed network syntheses (분포정수 회로합성을 이용한 RF 전력 증폭기 설계)

  • Kim Nam-Tae;Lee Min-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.602-607
    • /
    • 2006
  • In this paper, the distributed network synthesis, which is useful to the design of wireless power amplifiers, is proposed, and a RF power amplifier is designed using the technique. The transfer function of distributed matching circuits is derived by Chebyshev approximation, and network element values for a specified topology are given as a function of minimum insertion losses and ripples. As an example, after a power transistor is modeled by load-pull data, the synthesis for distributed matching networks is applied to a power amplifier design, which has the electrical performance of 17dB gain and less IM3 than -43dBc at the 20W output power between 800 to 900MHz frequency range. Experimental results from a fabricated amplifier are shown to approach the design performance in the operating frequency range. The design of impedance matching networks by the transfer function synthesis is a useful method for the design of RF power amplifiers.

  • PDF

Design of ISM-band Folded Dipole Active Integrated Antenna (ISM 대역용 접힌 다이폴 능동 집적 안테나의 설계)

  • 이재홍;서종수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11B
    • /
    • pp.1612-1619
    • /
    • 2001
  • This paper examines the design, implementation characteristics of a folded dipole active integrated antenna. Our goal was to minimize the physical size of RF circuit and its insertion loss, and to make the high frequency tuning easier by directly integrating the ISM(Industrial Scientific & Medical) band power amplifier and antenna. Non-linear model has been used for highly accurate simulation of the power amplifier. The maximum power level was found by using the Load pull method before an impedance matching was achieved. It is found that the total power-added efficiency(PAE) including the driving amplifier was 31.5% and that the transmit power was 13.7 dBm. We also found that the proposed scheme with the smaller antenna as compared with the existing dipole antenna has 23.7 dB total gain including the antenna gain. The suppression of the second harmonic signal to the fundamental signal with respect to the fundamental signal was found to be more than 30 dBc.

  • PDF

A Design of Amplifier Using Harmonic Termination Impedance Matching Tuner and Bias Line (고조파 차단 특성을 가지는 정합용 튜너와 바이어스 선로를 이용한 증폭기 설계)

  • Lee Jin-Kuk;Kim Su-Tae;Lim Jong-Sik;Jeong Yong-Chae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.12 s.103
    • /
    • pp.1186-1193
    • /
    • 2005
  • In this paper, a new 3 dB branch line hybrid using asymmetric spiral-shaped defected ground structure(DGS) microstrip is proposed. The proposed branch line hybrid suppresses the 2nd and the 3rd harmonic component effectively. Also a DGS $\lambda$/4 bias line that can suppress high frequency harmonics as well as low frequency intermodulation component is proposed. With the harmonic termination tuner using the proposed hybrid and the harmonic blocking bias line, the 2nd and the 3rd harmonic components of the fabricated amplifier that operated in IMT-2000 basestation transmitting band were suppressed up 25 dB and 27 dB, respectively. The proposed harmonic load-pull setup of amplifier is more easily accomplished with proposed circuits than the previous.

Failure of composite sandwich joints under pull-out loading (풀아웃 하중을 받는 복합재 샌드위치 체결부의 파손거동 연구)

  • Park, Yong-Bin;Yang, Hyeon-Jeong;Kweon, Jin-Hwe;Choi, Jin-Ho;Cho, Hyun-Il
    • Composites Research
    • /
    • v.24 no.1
    • /
    • pp.17-23
    • /
    • 2011
  • The failure of composite sandwich joints was experimentally investigated. A total of 30 joint specimens of 5 different types were tested with various fastening methods and core materials. In the NomexTM core sandwich joints, the core shear buckling was commonly observed in all the specimens which was followed by the slope change of the load-displacement curve. After the shear buckling, however, the joints carried additional loads of 50~200% over the buckling loads and then finally failed in the upper face breakage. The joints of PMI foam core showed the shear failure of the core instead of shear buckling and experienced the sharp drop of the carried load. Considering the failure modes, while both the core and face properties are important in the $Nomex^{TM}$ core joints, core shear strength seems to be the critical factor for the foam core joints.