• Title/Summary/Keyword: Load variations

Search Result 839, Processing Time 0.022 seconds

Reliability Assessments and Design Load Factors for Reinforced Concrete Containment Structures of Nuclear Power Plant

  • Han, Bong-Koo
    • Nuclear Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.444-450
    • /
    • 1997
  • The current ASME code for reinforced concrete containment structures are not based on probability concepts. The stochastic nature of natural hazard or accidental loads and the variations of material properties require a probabilistic approach for a rational assessment of structural safety and performance. The paper develops design load factors for the serviceability limit state of reinforced concrete containment structures. The target limit state probability is determined and the load factors are calculated by the numerical analysis. Design load factors are proposed and carried out the reliability assessments.

  • PDF

A Voltage Regulation System for Independent Load Operation of Stand Alone Self-Excited Induction Generators

  • Kesler, Selami;Doser, Tayyip L.
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1869-1883
    • /
    • 2016
  • In recent years, some converter structures and analyzing methods for the voltage regulation of stand-alone self-excited induction generators (SEIGs) have been introduced. However, all of them are concerned with the three-phase voltage control of three-phase SEIGs or the single-phase voltage control of single-phase SEIGs for the operation of these machines under balanced load conditions. In this paper, each phase voltage is controlled separately through separated converters, which consist of a full-bridge diode rectifier and one-IGBT. For this purpose, the principle of the electronic load controllers supported by fuzzy logic is employed in the two-different proposed converter structures. While changing single phase consumer loads that are independent from each other, the output voltages of the generator are controlled independently by three-number of separated electronic load controllers (SELCs) in two different mode operations. The aim is to obtain a rated power from the SEIG via the switching of the dump loads to be the complement of consumer load variations. The transient and steady state behaviors of the whole system are investigated by simulation studies from the point of getting the design parameters, and experiments are carried out for validation of the results. The results illustrate that the proposed SELC system is capable of coping with independent consumer load variations to keep output voltage at a desired value for each phase. It is also available for unbalanced consumer load conditions. In addition, it is concluded that the proposed converter without a filter capacitor has less harmonics on the currents.

Neural network-based load intensive controller design for DC motor (직류전동기의 부하변동을 보상하는 신경회로망 제어기의 설계)

  • 임종광;손재현;이광석;남문현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.628-631
    • /
    • 1992
  • The position control for DC motor under the unpredictable load variations is presented. Neural network controller trained to deal with this problem provide the estimates of system parameters. Pole placement is also performed in accordance with them. The proposed method is validated through computer simulation.

  • PDF

A Study on Air-Lubricated Spherical Tilting Pad Bearings (공기윤활 구면틸팅패드베어링에 대한 연구)

  • 김성국;김경웅
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.160-165
    • /
    • 1998
  • A theoretical analysis has been undertaken to show the influence of bearing geometry on the steady state characteristics of air lubricated spherical tilting pad bearings. The geometry variations considered are the number of pads, the eccentricity ratio, the direction of load, and the preloading.

  • PDF

Economical Installations and Regulations of Shunt Capacitors in A Distribution Line (배전선로에 있어서의 병렬 Coudenser의 경제적 설치 및 조정에 관한 연구)

  • 박영문
    • 전기의세계
    • /
    • v.15 no.5
    • /
    • pp.25-31
    • /
    • 1966
  • This paper derives the useful formulas for computing annual profits, and economical size, locations and regulating values of parallel shunt capacitors in case that they are installed in a distribution line. Inparticular, the derived formulas consider the influence of load variations in order to represent the actual load situations.

  • PDF

A study on the short-term load forecasting expert system considering the load variations due to the change in temperature (기온변화에 의한 수요변동을 고려한 단기 전력수요예측 전문가시스템의 연구)

  • Kim, Kwang-Ho;Lee, Chul-Heui
    • Journal of Industrial Technology
    • /
    • v.15
    • /
    • pp.187-193
    • /
    • 1995
  • In this paper, a short-term load forecasting expert system considering the load variation due to the change in temperature is presented. The change in temperature is an important load variation factor that varies the normal load pattern. The conventional load forecasting methods by artificial neural networks have used the technique where the temperature variables were included in the input neurons of artificial neural networks. However, simply adding the input units of temperature data may make the forecasting accuracy worse, since the accuracy of the load forecasting in this method depends on the accuracy of weather forecasting. In this paper, the fuzzy expert system that modifies the forecasted load using fuzzy rules representing the relations of load and temperature is presented and compared with a conventional load forecasting technique. In the test case of 1991, the proposed model provided a more accurate forecast than the conventional technique.

  • PDF

Dynamic Voltage Restorer (DVR) for 6.6[kV]/60[Hz] Power Distribution System Using Two Quasi Z-Source AC-AC Converters (두 개의 Quasi Z-소스 AC-AC 컨버터에 의한 6.6[kV]/60[Hz] 배전계통의 동적 전압 보상기(DVR))

  • Oum, Jun-Hyun;Jung, Young-Gook;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.199-208
    • /
    • 2012
  • This paper proposes a quasi Z-source DVR(Dynamic Voltage Restorer) system with a series connection of the output terminals, to compensate the voltage variations in the 6.6[kV]/60[Hz] power distribution system. The conventional DVR using one quasi Z-source AC-AC converter has the advantage which it can compensate the voltage variations without the need for the additional energy storage device such as a battery, but it is impossible to compensate for the 50[%] under voltage sags. To solve this problem, a DVR system using two quasi Z-source AC-AC converters with the series connection of the output terminals is proposed. By controlling the duty ratio D in the buck-boost mode, the proposed system can control the compensation voltage. For case verification of the proposed system, PSIM simulation is achieved. As a result, in case that the voltage sags-swells occur 10[%], 20[%], 60[%] in power distribution system, and, in case that the 50[%] under voltage sags-swells continuously occur, all case could compensate by the proposed system. Especially, the compensated voltage THD was examined under the condition of the 10[%]~50[%] voltage sags and the 20[${\Omega}$]~100[${\Omega}$] load changes. The compensated voltage THD was worse for the higher load resistances and more severe voltage sags. Finally, In case of the voltage swells compensation, the compensation factor has approached nearly 1 regardless of the load resistance changes, while the compensation factor of voltage sags was related to the load variations.

Assessment of the Ultimate Load-Carrying Capacity of RC Beams (RC보의 극한 내하력 평가)

  • Youn, Seok-Goo;Kim, Eun-Kyum;Seol, Dae-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.331-334
    • /
    • 2005
  • Three RC beams are fabricated and tested to assess the ultimate load-carrying capacity. Depending on the crackings, the flexural stiffness of the RC beams are changed. However, these variations of the flexural stiffness do not influenced on the ultimate load-carrying capacity of the tested beams. Based on the behaviors of RC beams, the validation of the current assessment codes to discussed.

  • PDF

A Novel Voltrol Method of Three-Phase PWM Inverter for UPS Application (UPS 응용을 위한 3상 PWM 인버터의 새로운 전압 제어 방법)

  • 이영조;박남주;임철우;정세교
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.260-265
    • /
    • 1999
  • This paper describes a novel control method of a three-phase PWM inverter for uninterruptible power supply(UPS) applications. To obtain the fast dynamics and excellent harmonic characteristics, a new state feedback control technique is proposed. The proposed control consists of the inner-loop current and outer-loop voltage controllers with a load current estimator to reduce the effects of the load variations and nonlinearity. In order to verify the effectiveness of the proposed control, the simulation is carried out for various load condition.

  • PDF

A Study on Indoor Environment of Interior with Ventilation

  • Kang, Tae-Wook;Koh, Jae-Yoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.267-274
    • /
    • 2006
  • There are no solar loads through windows and heat transfer from outer walls of the building to the interior This study analyzes indoor air temperature and air flow distribution for the interior of buildings or vessels occupying space. Numerical method is adopted to visualize the indoor side environmental situation. that is without heat transmission to outside the building in various cooling load conditions; supply ventilation lighting. occupancy and infiltration in conditioned spaces. Reaching time of an air conditioner is predicted theoretically by cooling load variations. Theoretical modelling of the reaching time shows good agreement with experimental results.