• Title/Summary/Keyword: Load types

Search Result 2,095, Processing Time 0.031 seconds

Formulation of General Equations for Plastic Collapse Loads of Grillages under a Lateral Point Load (집중하중을 받는 Grillage의 소성 붕괴하중 산정 및 일반식 도출)

  • Hong, Ki-Sup;Kim, Ki-Sung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.41 no.6
    • /
    • pp.91-101
    • /
    • 2004
  • For the grillage which is common types of structures in marine and land-based structural system, the elastic response and design methods are usually applied. However, plastic analysis and design methods are considered Tn those structures to maintain the structural stability at the limit states. In grillage design, the central intersection point load may be used as a worst loading condition. However, a point load may often move around on the grid system. in such case, the worst load point would not necessarily be at the central point. To investigate the variation of plastic collapse load according to the location of moving load between intersections, the plastic collapse loads are obtained for the three types of grillages with simply-supported ends. From the result of each case, it is confirmed that the worst load point is located between intersections. General formulae related with plastic collapse loads for the three groups of grillages with simply-supported boundaries are derived. Those plastic collapse formulae for the grillages are applied to the design of pontoon deck, and optimum design procedure is illustrated. Consequently, general formulae for the plastic collapse of grillages derived from this study can be easily applied to the plastic analysis and optimum design of similar grillages.

A Study on the Electrical Load Matching Analisys for the optimal utilization of grid-conntected PV system in Apartment Complex (공동주택의 태양광시스템 적용성 평가를 위한 전기부하 매칭 해석연구)

  • Yoon, Jong-Ho;Park, Jae-Sung;Shin, U-Cheul;Park, Jae-Wan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.49-54
    • /
    • 2008
  • This study is to investigate an optimal size and position of PV system for apartment complex enough the electrical load matching analysis. The 4 types of arrangements of apartment buildings are considered as follows; ㅡtype, alternative ㅡtype, ㄱtype and ㅁtype. We assume that the studied site is composed of 9 buildings. Firstly, solar access evaluation of roof and facade in apartment buildings was performing with the hourly simulations of total received insolation on each surface considering the hading effect of buildings. Electrical load profile of typical Korean apartments was investigated for the lad matching analysis. To calculate an annual total PV output, we used MERIT program which is a sourly based load matching tool developed by ESRU. TRY weather data of Daejeon are applied for this analysis. Result shows that approximately 11% of total electric load of the site can be supplied by the PV system in the case of full installation of PV system at the whole south-face roof area of 9 buildings in this stuided apartment complex. Depending of a various installation option of roof and facade area, the possible ratio of PV supply in total electrical load varies from 9% to 42%. Among the 4 arrangement types, the ㅡ type revealed the best option for the maximum output of PV system.

  • PDF

Evaluation of CPT-based Pile Load Capacity Factors with Cylindrical and Taper Pile (원통형 및 테이퍼말뚝의 하중-침하특성 및 CPT지지력상관계수)

  • Lee, Jun-Hwan;Paik, Kyu-Ho;Kim, Dae-Hong;Kim, Min-Kee;Hwang, Sung-Wuk
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.59-68
    • /
    • 2007
  • In this study, evaluation of load capacity and CPT-load capacity parameters were performed using calibration chamber tests for different types of piles including straight-side and tapered piles. Various soil conditions were considered in the investigation, aiming at establishing design procedure for foundation of electronic transmission tower structures. Test results show that no significant difference of total load capacity from straight-side and tapered piles, while individual components of base and shaft load capacities were quite different. Based on the test results, values of CPT-load capacity correlation parameters for different pile types were analyzed for the evaluation of both base and shaft load capacities.

Ultimate Load and Load Distribution of Ground Anchor in Waste Landfill (쓰레기 매립층에서 그라운드 앵커의 극한하중 및 하중분포)

  • Kim, Sung-Kyu;Cho, Kyu-Wan;Kim, Woong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1434-1441
    • /
    • 2005
  • For anchored system applications, each ground anchor is tested after installation and prior to being put into service to loads that exceed the design. This load testing methodology, combined with specific acceptance criteria, is used to verify that the ground anchor can carry the design load without excessive deformations and that the assumed load transfer mechanisms have been properly developed behind the assumed critical failure surface. After acceptance, the ground anchor is stressed to a specified load and the load is locked-off. The two types of load tests conducted during the research program included performance test and creep test which were carried out in accordance with testing procedures by AASHTO(AASHTO 1990) and FHWA(Weatherby 1998) at Samsung-Dong 00 Site. Form the measurements, ultimate load and creep rate of anchors are proposed for straight shaft pressured grouted anchors in waste landfill. The load distribution on the grout was obtained from the measured strain data at each fraction of the ultimate load during the load tests.

  • PDF

Valve Support Design for Improved Flexural Rigidity Against Strong Earthquake (강진 대비 굽힘 강성 향상을 위한 밸브지지대 형상 설계)

  • Kim, Dae Jin;Kim, Hyoung Eun;Seok, Chang Sung
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.75-80
    • /
    • 2017
  • In this study, seismic performance of various types of valve supports in terms of flexural rigidity are evaluated by FEA using equivalent static load method. Flexural rigidity of the existing two types of valve supports can be effectively improved by simply adding one more bracket on the other side of support. New types of polygonal valve supports with a concept of fully stressed beam theory are suggested and it is verified that the new supports are rigid enough to withstand stronger earthquake which we should be prepared for.

Statistical Analysis of Longitudinal Load Effects in Girder Bridges (거더교량의 종방향 하중효과의 확률론적 분석)

  • Oh, Byung-Hwan;Lew, Young;Choi, Young-Chul;Lee, Jun-Hyuk;Kim, Kwang-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.865-870
    • /
    • 2001
  • An effective live load model for analyzing probable maximum live load effects in longitudinal direction such as moment and shear was developed. The main procedure of this live load model is composed of two parts. Firstly, determination of the appropriate influence lines, and secondly, application of the characteristics of vehicles and traffic patterns. Through this procedure, probabilistic distributions of maximum probable load effects are deduced in the form of probability density function (PDF) or cumulative density function (CDF). The proposed live load model is not limited by bridge types(number of spans or girders) and can consider local or global deterioration of bridges in the analysis. Besides, load effects can be determined at any section without restrictions.

  • PDF

Earth Pressures Acting on the Rigid Wall under Incremental Load (점증하중에 의한 강성벽체에 작용하는 토압)

  • Chon, Yong-Baek;Kwon, Uk-Hwa
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.3
    • /
    • pp.247-254
    • /
    • 2002
  • This study has researched the following conclusion to compare to the existing theory and to examine lateral earth pressure, which have measured to add incremental load on sandy soil, and were different in types of compaction by modeling earth pressure test. Lateral earth pressure by incremental load shows that it is increasing at depth forty four centimeters as 2/3H point for wall high, and under 2/3 H point the variation of earth pressure on incremental load is not conspicuous. Therefor, the more a position of surcharge load is close with fixed wall, the more a variation of lateral earth pressure marks considerably. According to relative compaction density of soil, lateral earth pressure turns up larger effective value for layer compaction test to a thickness of thirty three centimeters than layer compaction test to a thickness of twenty centimeters by the roller.

  • PDF

Analysis of the Travel Distance in the Multiple-load Carrying Automated Guided Vehicle Systems (다부하를 운반하는 무인운반차시스템에서 운반거리의 분석)

  • Chang Suk-Hwa
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.28 no.1
    • /
    • pp.55-63
    • /
    • 2005
  • This paper is to analyze the travel distance and the transport size of the vehicle when the AGV carries multiple-load in the tandem automated guided vehicle systems. The size of multiple-load represents the number of load that the AGV can carry simultaneously. The AGV can carry simultaneously multiple-load that load types are different. The transport system of the manufacturing system is a tandem configuration automated guided vehicle system, which is based on the partitioning of all the stations into several non-overlapping single closed loops. Each loop divided has only one vehicle traveling unidirectionally around it. The AGV of each loop has to have sufficient transport capacity that can carry all loads for given unit time. In this paper, the average loaded travel distance and the size of feasible multiple-load of the vehicle are analyzed. A numerical example is shown.

A Comparison of Operating Characteristics for Industrial Water Cooler with Variation of Control Methods (제어방식에 따른 산업용 수냉각기의 운전 특성 비교)

  • Baek, Seung-Moon
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.99-105
    • /
    • 2014
  • This paper presents a comparison of operating characteristics for industrial water cooler with variation control methods. The performance analysis regarding the characteristics of condensation capacity, evaporation capacity, compressor load, COP of an on-off type cooler, a hot gas-bypass control type cooler and an inverter control type cooler with respect to the system load is reviewed, respectively. The primary results are as following: the variation of required compressor load of an on-off type cooler with respect to load is 5%, that of hot gas-bypass type is 18% and 66% for an inverter control type cooler. As the result shows, an inverter control type yields relatively huge difference of required compressor load compared to other types of control system. In terms of partial load, COP of an inverter control type cooler presents the highest value, and is considered as the optimized type for the used of the system involving frequent partial load.

A Study on the Structural Safety of Tower Crane Telescoping Work according to Wind Speed and Load (타워크레인 텔레스코핑 작업의 풍속 및 하중에 대한 구조 안전성 연구)

  • Jung, Sung-Lyoung;Lee, Do-Geun;Paik, Shinwon;Shin, Sang-Yeon
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.1
    • /
    • pp.9-17
    • /
    • 2021
  • This study analyses the load imbalance of the tower crane used in telescoping work for structural safety, owing to the difference in wind speed and balance weight position. This is because wind speed and position of the balance weight have a significant impact on the structural stresses of a tower crane during telescoping work. Therefore, structural analysis was performed on the 290HC model, which is often used at construction sites and has only one cylinder installed. Moreover, two models were classified to determine the load acting on the connecting part of the telescopic cage to slewing platform and the cylinder. Five types of balance weight positions were applied at regular intervals from jibs; moreover, four types of wind load criteria were differently applied. Hence, the telescopic cage columns were destroyed at all balance weight positions at a wind speed of 30 m/s and only at certain locations at a wind speed of 20 m/s. Furthermore, failures occurred for cylinders, torsional, and bending at wind speeds of 30 m/s and 20 m/s, load imbalances above the allowable thresholds considering the safety factor. In addition, the load imbalance in the telescoping work also varied depending on the position of the balance weights. The results of these studies have validated that the current standards of adjusting the appropriate position of the balance weights on the jib are completely valid, with the telescoping work to be executed only at wind speeds of less than equal to 10 m/s.