• Title/Summary/Keyword: Load types

Search Result 2,095, Processing Time 0.026 seconds

Contribution of Non-Point Pollution to Water Quality and Runoff Characteristics from Agricultural Area of the Upstream Watersheds of Lake Chinyang

  • Lee, Chun-Sik;Jang, Seong-Ho
    • Journal of Environmental Science International
    • /
    • v.22 no.3
    • /
    • pp.259-267
    • /
    • 2013
  • In this study, non-point source(NPS) contribution was investigated based on flow rates and water qualities of streams into the lake during rainfall events. Event mean concentration(EMC) and the pollution loads were calculated to establish a database for NPS control measurement in the survey area, and so on. The runoff characteristics of NPS were investigated and estimated on the basis of the ratio of an agricultural to forest area in the stream of sub-catch basin during rainfall events. Non-point source pollution loads were also calculated to establish a database for NPS control measure in the upstream lake Chinyang. At a rainfall event, BOD concentrations rise sharply at the early peak time of runoff, however, peaks of TSS concentration were observed at the similar time of peak flow. This was a phenomenon shown at the watersheds caused by forest and geological types. The discharged EMC range was 2.9-4.8 mg/L in terms of BOD. The discharged EMC range was 6.2-8.2 mg/L in terms of SS. The discharged EMCs of T-N and T-P were 1.4-2.5 mg/L and 0.059-0.233 mg/L, respectively. Total BOD loading rate through the 3 tributaries to the lake Chinyang was 1,136 kg/d during dry weather. The upper watershed area of the Nam-river dam in this study was divided into 14 catchment basins based on the Korean guideline for total maximum daily load(TMDL) of water quality pollutants. The higher the agricultural land-use ratio, the more NPS loading rate discharged, but the more occupied a forest area, the lower more NPS loading rate discharged. In an agricultural land-use area more than 20%, the increase of NPS loadings might be dramatically diffused by increasing the integrated complex-use like vinyl-house facilities and fertilizer use etc. according to the effective land-use utilization. The NPS loading rates were BOD 0.3 $kg/ha{\cdot}day$, SS 0.21 $kg/ha{\cdot}day$, TN 0.02 $kg/ha{\cdot}day$, TP 0.005 $kg/ha{\cdot}day$ under less than 10% agricultural land-use. In agricultural land-use of 20%-50%, these values were investigated in the range of 0.32 $kg/ha{\cdot}day$-0.73 $kg/ha{\cdot}day$ for BOD, 0.92 $kg/ha{\cdot}day$-3.32 $kg/ha{\cdot}day$ for SS, 0.70 $kg/ha{\cdot}day$-0.90 $kg/ha{\cdot}day$ TN, 0.03 $kg/ha{\cdot}day$-0.044 $kg/ha{\cdot}day$ for TP.

Comparison of Relative Thickness of the Iliotibial Band Following Four Self-Stretching Exercises

  • Kim, Hyun-Sook;Yoon, Tae-Lim
    • Physical Therapy Korea
    • /
    • v.19 no.4
    • /
    • pp.24-31
    • /
    • 2012
  • The aim of this study was to investigate the effectiveness of self-stretching exercises for iliotibial band (ITB) (Side-lying; right hip and knee were flexed to support the pelvis while left hip was extended and adducted, Standing A; side-bending of the trunk on standing with crossed leg, Standing B; same as Standing A, except the hands were clasped overhead and shifted right side, and Standing C; same as Standing B, except moving the arms diagonally downward) to help determine the most effective self-stretching method to stretch ITB. Twenty-one healthy subjects who do not have ITB shortness from Yonsei University (14 men and 7 women) between the ages of 18 to 28 years voluntarily participated. Ultrasound was performed to measure the thickness of the ITB between the long axis of the ITB and the level parallel to the lateral femoral epicondyle during four self-stretching exercises. All data were found to approximate a normal distribution. We used a one-way repeated-measures analysis of variance (ANOVA) to compare the thickness of the ITB among all self-stretching exercises. The level of significance was set at ${\alpha}$=.05. The ANOVA was followed by Bonferroni's correction. The overall mean of ITB thickness was $1.14{\pm}.4$ mm (${\pm}$ standard deviation) in resting status. The change in the ITB thickness in percentages between the tested position of each self-stretching exercises and resting status was significant (p<.05) (Side-lying $26.62{\pm}10.18%$ with 95% confidence interval [CI]=21.99~31.25%; Standing A $29.46{\pm}16.19%$ with 95% CI=22.09~36.84%; Standing B $44.06{\pm}14.82%$ with 95% CI=37.31~50.81%; Standing C $53.76{\pm}12.1%$ with 95% CI=48.25~59.29%). Results indicated significant differences among four self-stretching exercises except Side-lying versus Standing A (p<.01). Based on these findings, the Standing C self-stretching exercise was the most effective in stretching the ITB thickness among four types of ITB self-stretching exercises. Additionally, the Side-lying self-stretching exercise using gravity to stretch the ITB is recommended as a low-load (low-intensity), long-duration stretch.

A STUDY OF CORE TYPE AND LUTING CEMENTS ON COMPLETE CAST CROWN RETENTION (코어 형태와 시멘트 종류에 따른 전부주조금관의 유지력에 관한 연구)

  • Paek, Sang-Hyun;Chang, Ik-Tae;Lee, Sun-Hyung;Yang, Jae-Ho;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.169-177
    • /
    • 2000
  • The purpose of this study was to compare the retention of complete cast crown over amalgam ores, composite resin cores, and cast gold cores when cemented with three different luting agents. Eighteen core specimens each of amalgam(Bestaloy, Dong Myung, Seoul, Korea), composite resin (Z100, 3M Dental product, st. Paul, Minn) and type IV gold alloy (Ba-4, Heesung Engelhard Corp., Korea) were made in a customized milling stainless steel die. A wax pattern with a loop attached to occlusal surface was made for each core and a type II gold alloy casting was fabricated. The castings which had clinically acceptable marginal fit were used as test samples. The following luting cements were used to cement cast crowns on each core material : (1) zinc phosphate cement (Confi-dental Products Co., USA) (2) glass-ionomer cement (Fuji Plus, GC Industrial Corp., Tokyo, Japan) (3) resin cement (Panavia 21, Kuraray Co., USA). All cements were mixed according to manufacturers' instructions. A static load of 5kg was then applied for 10 minutes on the crowns. All specimens were stored in saline solution for 24 hours at $37^{\circ}C$ and thermocycled for 500 cycles. After storage and cycling, the tensile bond strengths were measured by using a universal testing machine (Instron Corp., Canton, Mass.) at a crosshead speed of 0.5mm/min. The results were as follows 1. The retentive strength of resin cement was the highest of alt three types of cement for resin core (p<0.05). 2. There was no statistical difference among the retentive strengths of three cements for amalgam core (p>0.05). 3. The retentive strength of resin cement was higher than that of zinc phosphate for cast core, but there was no difference between the retentive strength of glass ionomer cement and those of rein and zinc phosphate cement. 4. The retentive strength of the zinc phosphate cement for amalgam core was the highest of all type of cores.

  • PDF

THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND DISPLACEMENT IN MANDIBLE ACCORDING TO TREATMENT MODALITIES OF MANDIBULAR ANGLE FRACTURES (하악각 골절의 치료 방법에 따른 하악골의 응력 분포 및 변위에 관한 삼차원 유한요소법적 연구)

  • Ku, Je-Hoon;Kim, Il-Kyu;Chang, Jae-Won;Yang, Jung-Eun;Sasikala, Balaraman;Wang, Boon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.3
    • /
    • pp.207-217
    • /
    • 2010
  • The purpose of this study was to evaluate the effects of the stress distribution and displacement in mandible according to treatment modalities of mandibular angle fractures, using a three dimensional finite element analysis. A mechanical model of an edentulous mandible was generated from 3D scan. A 100-N axial load and four masticatory muscular supporting system were applied to this model. According to the number, location and materials of titanium and biodegradable polymer plates, the experimental groups were divided into five types. Type I had a single titanium plate in the superior border of mandibular angle, type II had two titanium plates in the superior tension border and in the inferior compression border of mandibular angle, type III had a single titanium plate in the ventral area of mandibular angle, type IV had a single biodegradable polymer plate in the superior border of mandibular angle, type V had a single biodegradable polymer plate in the ventral area of mandibular angle. The results obtained from this study were follows: 1. Stress was concentrated on the condylar neck of the fractured side except Type III. 2. The values of von-Mises stress of the screws were the highest in the just-posterior screw of the fracture line, and in the just-anterior screw of Type III. 3. The displacement of mandible in Type III was 0.04 mm, and in Type I, II, IV, and V were 0.10 mm. 4. The plates were the most stable in the ventral area of mandibular angle (Type III, V). In conclusion, the ventral area of mandibular angle is the most stable location in the fixation of mandibular angle fractures, and the just- posterior and/or the just-anterior screws of the fracture line must be longer than the other, and surgeons have to fix accurately these screws, and the biodegradable polymer plate also was suitable for the treatment of mandible angle fracture.

Assessment of Impact-echo Method for Cavity Detection in Dorsal Side of Sewer Pipe (하수관거 배면 공동 탐지를 위한 충격반향법의 적용성 평가)

  • Song, Seokmin;Kim, Hansup;Park, Duhee;Kang, Jaemo;Choi, Changho
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.8
    • /
    • pp.5-14
    • /
    • 2016
  • The leakage of water under sewer pipelines is one of main sources of sinkholes in urban areas. We performed laboratory model tests to investigate the presence of cavities using impact-echo method, which is a nondestructive test method. To simulate a concrete sewer pipe, a thin concrete plate was built and placed over container filled with sand. The cavity was modeled as an extruded polystyrene foam box. Two sets of tests were performed, one over sand and the other on cavity. A new impact device was developed to apply a consistent high frequency impact load on the concrete plate, thereby increasing the reliability of the test procedure. The frequency and transient characteristics of the measured reflected waveforms were analyzed via fast Fourier transform and short time Fourier spectrum. It was shown that the shapes of Fourier spectra are very similar to one another, and therefore cannot be used to predict the presence of cavity. A new index, termed resonance duration, is defined to record the time of vibration exceeding a prescribed intensity. The results showed that the resonance duration is a more effective parameter for predicting the presence of a cavity. A value of the resonance period was proposed to estimate the presence of cavity. Further studies using various soil types and field tests are warranted to validate the proposed approach.

Analysis on Bond Characteristics of Reinforcements for UHPC Hybrid Cable-Stayed Bridge Deck Joints (초고성능 콘크리트 하이브리드 사장교 바닥판 접합부 철근의 부착 성능에 대한 해석)

  • Seonwoo, Yoon Ho;Park, Sung Kyun;Kwahk, Im Jong;Yoon, Young Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3A
    • /
    • pp.207-214
    • /
    • 2011
  • Ultra High Performance Concrete (UHPC), which is characterized by its high strength and advanced ductile behavior that is much superior to those of convention concrete, is a useful material to make thinner and longer bridges. The precast segmental construction method utilizing UHPC has been mainly studied because cast-in-place UHPC is very difficult and complicate to be achieved. As a part of those research, the structural performance evaluation of different types of joint connection method for hybrid cable-stayed bridge utilizing UHPC by using nonlinear analyses is performed in this study. The bond stress at joint is obtained by section force analyses for a 600 m cable-stayed bridge deck, and compared with the required bond stress at joint. Analysis results show that the U Type connection and straight type connection resist the highest ultimate load and bond strength, respectively. In addition, all considered joint connection systems satisfy the bond performances at joint required in the final stage of cable-stayed bridge utilizing UHPC.

Diagnosis of Development Projects and Water Quality Changes in the Environmental Management Sea Areas and Improvement of Impact Assessment (환경관리해역의 이용개발현황과 수질변화경향 및 영향평가 개선방안)

  • Jun, Eun Ju;Yi, Yong Min;Lee, Dae In;Kim, Gui Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.6
    • /
    • pp.726-734
    • /
    • 2018
  • The total number of Sea Area Utilization Consultation in the environment management sea areas reviewed from 2015 to 2017 were 60. The number of development projects in the environment conservation sea areas decreased steadily, but special management sea areas increased. Development types in environment management sea areas showed that artificial structure installation was the highest ratio, followed by fishery port development and construction of habor and coastal maintenance and sea water intake and draining. By comparing the trend of water quality changes using marine environment information system (MEIS) data in the environment management areas from 2006 to 2017, COD showed no significant changes but the environment conservation sea areas increased slightly, and the concentration of TN and TP decreased. Gwangyang and Masan bays in the special management sea areas and Gamak bay in the environment conservation sea areas displayed oxygen deficient mass in the summer. As the use of development projects of the environment management sea areas are performed continuously, an analysis of the status of sufficient water quality changes is necessary for environmental impact assessment (Sea Area Utilization Consultation) in the marine environment and should be evaluated mainly for management of contamination by diagnosing thoroughly water quality effects and the pollution of sediment. Especially, the water quality goal for the purpose of designation in each of the environment management sea areas is set clearly, connection with pollution source control and the total pollution load management system (TPLMS) should be proposed and measured to reduce the amount of contaminated water.

A Component-Based Framework for Structural Embedding of Mobile Agent System (모바일 에이전트 시스템의 구성적 임베딩을 위한 컴포넌트 기반의 프레임워크)

  • Chung, Wonho;Kang, Namhi
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.6
    • /
    • pp.33-42
    • /
    • 2012
  • Rapid evolution of wired and wireless technologies results in various types of embedded systems, and the software to be embedded into those devices now needs the flexibility rather than the fixedness which was well-known property for the embedded software in the past. Mobile agent is one of the useful distributed technologies of reducing network load and latency because of its disconnected operations and high asynchrony. In this paper, a component-based mobile agent framework, called EmHUMAN, is designed and implemented for structural embedding into the devices showing different functions and resource constraints. It consists of 3 layers of components. Based on those components, a structural embedding, considering resource constraints of required functions, amount of storage space, computing power, network bandwidth, ${\ldots} $ etc can be performed. The components in each layer can be extended with addition of new components, removing some components and modifying components. EmHUMAN plays the role of a framework for developing mobile agent based distributed systems. It is also a mobile agent system by itself. EmHUMAN provides several utilities as built-in API's, and thus high effectiveness in programming mobile agents can be achieved.

Study on the Technical Security Factor for the Implementation of Secure DB System (안정적인 DB보안 시스템 구축을 위한 보안기술요소 분석에 관한 연구)

  • Yoon, Sun-Hee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.12
    • /
    • pp.143-152
    • /
    • 2014
  • This paper introduces Database security to prevent the rapidly increasing issue of private information leakage. The Database security examined in the paper separates into DB access control area and DB encryption area which further leads the paper to analyze the factors of the two areas and suggest necessary elements for creating stable Database security. In addition, the paper examines previous DB security programs by areas and analyzes pros and cons from the tested result. The experiment indicated that while DB access control presents less degradation and reduced the need to modify the existing DBMS since the access control operates at the end point of the network, DB encryption presented strength in protecting the data from unauthorized access. On the other hand, DB access control is less useful in preventing the attack in advance which leaves the log to enable tracking afterward while DB encryption can only be operated by limited types of Database and causes degradation due to system load and shows higher percentage of failure when creating the system. This paper examines characteristics of Database security areas in order to be used as a reference for institutions or companies seeking stable Database security.

Effect of Compaction Method on Induced Earth Pressure Using Dynamic Compaction Roller (진동롤러에 의한 다짐방법이 인접구조물의 다짐토압에 미치는 영향)

  • Roh, Han-Sung
    • International Journal of Highway Engineering
    • /
    • v.3 no.4 s.10
    • /
    • pp.127-136
    • /
    • 2001
  • To increase the structural integrity of concrete box culvert good compaction by the dynamic compaction roller with bi9 capacity is as effective as good backfill materials. It is needed for effective compaction that a compaction roller closes to concrete structure with high frequency. However structural distress of the culvert could be occur due to the excessive earth pressure by great dynamic compaction load. To investigate the characteristics of Induced stress by compaction, a box culvert was constructed with changing cushion materials and compaction methods. Two types of cushion material such as tire rubber chip and EPS(Expanded Polystyrene) were used as cushion panels and they are set on the culverts before backfill construction. Laboratory test result of cushion material says that the value of dynamic elastic modulus of rubber is lesser than that of EPS. On the other hand, material damping of rubber material is greater than that of EPS. In most case, dynamic compaction rollers with 10.5 ton weights were used and vibration frequency was applied 30Hz for the great compaction energy. This paper presents the main results on the characteristics of dynamic earth pressures during compaction. The amounts of induced dynamic pressures$(\Delta\sigma\;h)$ by compaction are affected with construction condition such as compaction frequency, depth of pressure cell, distance between roller and the wall of culvert and roller direction. Based on the measured values dynamic lateral pressure on the culverts, it could be said that orthogonal direction of roller to the length of culvert is more effective to compaction efficiency than parallel direction.

  • PDF