• Title/Summary/Keyword: Load stimulation

Search Result 29, Processing Time 0.02 seconds

Parallel Load Techinques Application for Transcranial Magnetic Stimulation

  • Choi, Sun-Seob;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.17 no.1
    • /
    • pp.27-32
    • /
    • 2012
  • Transcranial magnetic stimulation requires an electric field composed of dozens of V/m to achieve stimulation. The stimulation system is composed of a stimulation coil to form the electric field by charging and discharging a capacitor in order to save energy, thus requiring high-pressure kV. In particular, it is charged and discharged in capacitor to discharge through stimulation coil within a short period of time (hundreds of seconds) to generate current of numerous kA. A pulse-type magnetic field is formed, and eddy currents within the human body are triggered to achieve stimulation. Numerous pulse forms must be generated to initiate eddy currents for stimulating nerves. This study achieved high internal pressure, a high number of repetitions, and rapid switching of elements, and it implemented numerous control techniques via introduction of the half-bridge parallel load method. In addition it applied a quick, accurate, high-efficiency charge/discharge method for transcranial magnetic stimulation to substitute an inexpensive, readily available, commercial frequency condenser for a previously used, expensive, high-frequency condenser. Furthermore, the pulse repetition rate was altered to control energy density, and grafts compact, one-chip processor with simulation to stably control circuit motion and conduct research on motion and output characteristics.

Starting Current Application for Magnetic Stimulation

  • Choi, Sun-Seob;Bo, Gak-Hwang;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.16 no.1
    • /
    • pp.51-57
    • /
    • 2011
  • A power supply for magnetic-stimulation devices was designed via a control algorithm that involved a start current application based on a resonant converter. In this study, a new power supply for magnetic-stimulation devices was designed by controlling the pulse repetition frequency and pulse width. The power density could be controlled using the start-current-compensation and ZCS (zero-current switching) resonant converter. The results revealed a high-repetition-frequency, high-power magnetic-stimulation device. It was found that the stimulation coil current pulse width and that pulse repetition frequency could be controlled within the range of 200-450 ${\mu}S$ and 200-900 pps, respectively. The magnetic-stimulation device in this study consisted of a stimulation coil device and a power supply system. The maximum power of the stimulation coil from one discharge was 130 W, which was increased to 260 W using an additional reciprocating discharge. The output voltage was kept stable in a sinusoidal waveform regardless of the load fluctuations by forming voltage and current control using a deadbeat controller without increasing the current rating at the starting time. This paper describes this magnetic-stimulation device to which the start current was applied.

Immediate Effects of Load Stimulation on Static Balance and Muscle Activities in Chronic Stroke Patients (부하자극이 만성뇌졸중 환자의 정적 균형, 근육 활성도에 미치는 효과)

  • Lee, Seung-Won;Shin, Won-Seob;In, Tae-Sung;Lee, Sun-Hyun;Lee, Hae-Hyun;Lee, Kyoung-Jin;Song, Chang-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.1
    • /
    • pp.19-25
    • /
    • 2009
  • Purpose: We investigated the changes that effects of load stimulation (LS) on static balance and muscle activities in normal healthy elders and chronic stroke patients. Methods: Subjects were instructed twenty normal healthy elders (8 men and 12 women) and ten chronic stroke patients (4 men and 6 women). They were tested while standing on a force platform under two conditions; LS, no LS were applied in random order. Prior to testing, adhesive surface EMG electrodes were fastened to the skin overlying the right (non-paralytic side in stroke patient) bellies of tibialis anterior (TA) and lateral gastrocnemius (LG) muscles. They were assessed on postural sway and %MVC (Maximum voluntary contraction) of TA and LG. Results: Participants showed that the application of LS brought about a decrease in postural sway as expressed by average sway path and velocity. %MVC of TA and LG were increased. The application of LS to normal and stroke patients decreases postural sway during quite stance. Conclusion: These findings the application of LS to normal and stroke patients improves static balance.

  • PDF

EGS Power Generation and Hydraulic Stimulation (EGS 지열발전과 저류층 수리자극 기술)

  • Min, Ki-Bok;Song, Yoonho;Yoon, Woon-Sang
    • Tunnel and Underground Space
    • /
    • v.23 no.6
    • /
    • pp.506-520
    • /
    • 2013
  • While geothermal energy provides the only base-load power among renewable energy sources, its development has been carried out predominantly in volcanic area. EGS (Enhanced Geothermal System) is a ubiquitous technology that can allow the geothermal power generation virtually in any area. This manuscript introduces the current state-of-the-art of EGS development in the world and presents the hydraulic stimulation technology and associated microseismicity which are key technical component in EGS. Finally this paper suggests the key research areas required in Korea for further development of EGS.

Effects of Cranial Electrotherapy Stimulation on Electrocephalogram

  • Lee, Jeongwoo;Lee, Hyejein;Park, Woongsik
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.1
    • /
    • pp.1687-1694
    • /
    • 2019
  • Background: Although cranial electrotherapy stimulation (CES) is reported to have positive effects on mental functions such as depression and sleep improvement, detailed studies regarding awakening, attention and concentration among brain waves reflecting brain activity are lacking. Objective: To examine the effects of cranial electrotherapy stimulation (CES) on various electroencephalograms (EEGs) reflecting brain activities. Design: Randomized controlled clinical trial (single blind) Methods: This study selected 30 healthy adult women in their 20s who volunteered for this experiment. A total of 30 subjects were randomly assigned to three groups (Sham group, 0.5 Hz CES group, and 100 Hz CES group). EEGs were measured before and after the single CES, and the results were compared and analyzed. Results: The relative theta, alpha, and gamma waves indicated no significant differences in the interaction effects between time and group. The relative fast alpha wave only showed significant differences in the interaction effects between time and group in P4. The relative slow beta wave only indicated statistically significant differences in the interaction effects between time and group in T3 and T4. The relative mid and fast beta waves showed statistically significant differences in the interaction effects between time and group in all areas. Conclusions: These results suggest that a CES of 0.5 Hz awakens consciousness and has a positive influence on brain activity, while a CES of 100 Hz has a positive influence on thinking activity accompanying mental load during concentrating on one subject.

A High-Voltage Compliant Neural Stimulation IC for Implant Devices Using Standard CMOS Process (체내 이식 기기용 표준 CMOS 고전압 신경 자극 집적 회로)

  • Abdi, Alfian;Cha, Hyouk-Kyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.5
    • /
    • pp.58-65
    • /
    • 2015
  • This paper presents the design of an implantable stimulation IC intended for neural prosthetic devices using $0.18-{\mu}m$ standard CMOS technology. The proposed single-channel biphasic current stimulator prototype is designed to deliver up to 1 mA of current to the tissue-equivalent $10-k{\Omega}$ load using 12.8-V supply voltage. To utilize only low-voltage standard CMOS transistors in the design, transistor stacking with dynamic gate biasing technique is used for reliable operation at high-voltage. In addition, active charge balancing circuit is used to maintain zero net charge at the stimulation site over the complete stimulation cycle. The area of the total stimulator IC consisting of DAC, current stimulation output driver, level-shifters, digital logic, and active charge balancer is $0.13mm^2$ and is suitable to be applied for multi-channel neural prosthetic devices.

Precision Speed Control of PMSM for Stimulation of the Vestibular System Using Rotatory Chair (전정기관 자극용 회전자극기를 위한 PMSM의 정밀 속도제어)

  • 이태호
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.628-631
    • /
    • 2000
  • A new control method for precision robust speed control of a PMSM(Permanent Magnet Synchronous Motor) using load torque observer is presented. With this system we can obtain more reliable eye moving singal(nystagmus) Until now rotating chair system which is called 2D-optokinetic stimulator is used to make dizzincess. However an inclined rotating chair system witch is 3D-optokinetic stimulator is needed to obtain the precise dizziness data. This 3D-optokinetic sitimulator include unbalanced load aused by unbalanced center of mass. For this case new compensation method is considered to obtain robust speed control using load torque observer. To reduce the effect of this disturbance we can use dead-beat observer which has high gain. The application of the load torque observer is published in [1] for position control. A problem of using speed information such as amplifying effect of noise is reduce by moving average process. The experimental results are depicted in this paper to show the effect of this proposed algorithm.

  • PDF

Feasibility of Optoelectronic Neural Stimulation Shown in Sciatic Nerve of Rats (흰쥐의 좌골 신경 자극을 통한 광전 자극의 가능성에 대한 연구)

  • Kim Eui tae;Oh Seung jae;Baac Hyoung won;Kim Sung june
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.611-615
    • /
    • 2004
  • A neural prostheses can be designed to permit stimulation of specific sites in the nervous system to restore their functions, lost due to disease or trauma. This study focuses on the feasibility of optoelecronic stimulation into nervous system. Optoelectronic stimulation supplies, power and signal into the implanted optical detector inside the body by optics. It can be effective strategy especially on the retinal prosthesis, because it enables the non-invasive connection between the external source and internal detector through natural optical window 'eye'. Therefore, we designed an effective neural stimulating setup by optically based stimulation. Stimulating on the sciatic nerve of a rat with proper depth probe through optical stimulation needs higher ratio of current spreading through the neural surface, because of high impedance of neural interface. To increase the insertion current spreading into the neuron, we used a parallel low resistance compared to load resistance organic interface and calculated the optimized outer parallel resistance for maximum insertion current with the assumption of limited current by photodiode. Optimized outer parallel resistance was at a range of 500Ω-700Ω and a current was at a level between 580uA and 650uA. Stimulating current efficiency from initial photodiode induced current was between 47.5 and 59.7%. Various amplitude and frequency of the optical stimulation on the sciatic nerve showed the reliable visual tremble, and the action potential was also recorded near the stimulating area. These result demonstrate that optoelectronic stimulation with no bias can be applied to the retinal prosthesis and other neuroprosthetic area.

Effects of Applying Intensity on Muscle Activity and Muscle Hardness of Upper Trapezius Muscle in Adult Males applying Transcutaneous Electrical Nerve Stimulation (경피적전기신경자극 적용 시 적용강도가 성인남성의 위등세모근의 근활성도와 근경도에 미치는 영향)

  • Kim, Chung-Yoo;Bae, Won-Sik;Cha, Young-Joo
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.1
    • /
    • pp.129-136
    • /
    • 2022
  • Purpose : The purpose of this study was to investigate the effect of applying intensity on the muscle activity and muscle hardness of the upper trapezius muscle in adult males when TENS (transcutaneous electrical nerve stimulation) was applied. In addition, this study intends to prepare the scientific basic data of TENS for the purpose of relaxation based on the experimental results. Methods : Eighty-seven healthy adult males participated in the experiment, and they were randomly divided into an experimental group and a control group. All subjects in this study were healthy subjects without musculoskeletal or nervous system damage. All subjects were subjects who voluntarily consented to the purpose and method of the experiment. All subjects were provided with a load by typing for 20 minutes, and muscle activity and muscle hardness of the upper trapezius muscle were measured immediately. Afterwards, TENS was given to each groups for 15 minutes, and the experimental group received stimulation at the motor threshold level, and the control group received a placebo stimulation. After stimulation, muscle activity and muscle hardness of the upper trapezius muscle were measured in the same method. The measured data were compared between groups through an independent t-test and dependent t-test. The statistical significance level was set at .05. Results : The application of TENS statistically significantly decreased the muscle activity and muscle hardness of the trapezius muscle in the experimental group, and the results showed a significant difference from the control group. Conclusion : Application of TENS significantly decreased the muscle activity and muscle stiffness of the upper trapezius muscle. The application of TENS of applying intensity that induces muscle contraction may induce relaxation by reducing the muscle activity and muscle hardness of the trapezius muscle.

Development of the Off-vertical Rotary Chair and Visual Stimulation system for Evaluation of the Vestibular Function (전정기능 평가를 위한 탈수직축 회전자극 시스템 및 HMD 시스템의 개발)

  • Kim Gyu-Gyeom;Ko Jong-Sun;Park Byung-Rim
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.377-380
    • /
    • 2001
  • The vestibular system located in the inner ear controls reflex body posture and movement. It has the semicircular canals sensing an angular acceleration and the otolith organs sensing a linear acceleration. With this organic signal, medical doctor decide if a person has disease or not. To obtain this data, a precision stimular system is considered. Robust control is needed to obtain eye signals induced by off-vertical axis rotation because of an unbalanced load produced by tilting the axis of the system upto 30 degrees. In this study, off-vertical axis rotatory system with visual stimulation system are developed. This system is consisted of head mounted display for generating horizontal, vertical, and three dimensional stimulus patterns. Furthermore wireless recording system using RF modem is considered for noiseless data transmission.

  • PDF