• 제목/요약/키워드: Load efficiency

검색결과 3,185건 처리시간 0.029초

기계실 위치 변화가 고효율 갠트리 크레인의 안정성에 미치는 영향 분석 (The Effect of Machinery House Location on the Stability of High Efficiency Gantry Crane)

  • 이성욱;한근조;심재준;한동섭;권순규;김태형
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1605-1608
    • /
    • 2005
  • This study was carried out to analyze the effect of machinery house location on the stability of high efficiency gantry crane which can improve the productivity of the container transportation wok by reducing cycle time. The wind load was evaluated according to 'Load Criteria of Building Structures' enacted by the ministry of construction & transportation. The uplift forces of high efficiency gantry crane under this wind load were calculated by analyzing reaction forces at each supporting point. And variation of reaction forces at each supporting point was analyzed according to machinery house location.

  • PDF

Light-load에서 고효율을 가지는 PFM 전류모드 DC-DC Buck 변환기 (A Current-Mode DC-DC Buck Converter with PFM to Improve the Light-Load Efficiency)

  • 안영국;남현석;노정진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.601-602
    • /
    • 2008
  • This paper presents pulse-frequency modulation(PFM) to improve the light-load efficiency. The proposed circuit is designed by using the device parameter of standard $0.13{\mu}m$ CMOS process. The performance of proposed circuit is evaluated by HSPICE simulation Measured efficiency in a light-load is measured 78-90 % for 0.1 to 100mA output current.

  • PDF

압전특성 및 부하변화에 따른 압전트랜스포머의 전기적 특성 (Electrical Characteristics of the Piezoelectric Transformer as a Function of Piezoelectric Properties and Load Variations)

  • 민석규;윤광희;류주현
    • 한국전기전자재료학회논문지
    • /
    • 제14권4호
    • /
    • pp.289-296
    • /
    • 2001
  • The piezoelectric transformers of 2.0x10x48 ㎣ size were fabricated with PSN-PMN-PZT(T10 and PNW-PMN-PZT(T2) composition ceramics. Effects of micro structural and piezoelectric properties on the electrical characteristics of the piezoelectric transformers were investigated. Under the fixed output power of 6 W, temperature rise of T1 transformer at the optimum load was smaller than T2 one because of fine grain size effect. Voltage step-up ratio of T1 transformer showed higher value than T2 one T1 transformer showed an excellent properties with voltage step-up ratio of 12.41, efficiency of 95.23% and temperature rise of 7.2$^{\circ}C$ at 200㏀ load resistance. And also, T2 transformer showed an excellent properties with voltage step up ratio of 9.81, efficiency of 95.51% and temperature rise of 9$^{\circ}C$ at 150㏀ load resistance.

  • PDF

가중효율을 적용한 2-Stage Boost 컨버터 최적효율 운전 연구 (Optimal Efficiency Operation of 2-Stage Boost Converter With Weighted Efficiency)

  • 김승민;김동희
    • 전력전자학회논문지
    • /
    • 제26권4호
    • /
    • pp.285-293
    • /
    • 2021
  • An optimal operation method based on weighted efficiency for a two-stage boost converter is proposed in this study. Detailed loss analysis of the converter is performed to derive the optimal operation method according to the load and input voltage fluctuations, and the optimal DC-bus voltage is derived by applying the weighted efficiency method. The proposed method can satisfy optimal efficiency in the main operation region without a complicated control method. Using 1kW typical two-stage boost converter and is verified three types of weighted efficiency formulas and loss analysis are utilized to derive high-efficiency optimal DC-bus voltage from each load range.

대학교 기숙사의 전력소비량과 BIPV시스템의 발전효율·부하부담율에 관한 연구 (A Study on the Power Consumption and the Generation Efficiency and Load Rate of the Building Integrated Photovoltaic System in University Dormitories)

  • 서원덕;이강국;홍원화
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.87-93
    • /
    • 2011
  • This study examines building's power consumption unit cost and Building Integrated Photovoltaic (BIPV)'s generation efficiency and load rate with the subjects of university dormitory buildings in order to suggest foundational data for new and recycled energy use and management to plan and operate university dormitories afterwards. Thereby, this research gained the following findings. 1. The quantity of solar radiation and efficiency change in the BIPV system applied to the research subject buildings after the lapse of time was averagely 8.7%, and it is thought that temperature increase determines conversion efficiency with the influence of surrounding outside temperature and the module's temperature. 2. The generation efficiency of the BIPV system in the research subject buildings was averagely 10.9%. In May, it was 13.9%, and in January, it was the lowest as 10.25%. Considering the fact that power consumption reduces during an intermediate period, it will be necessary to establish measures for equipment and power consumption load balancing. 3. The monthly load rate of the BIPV system was averagely 4.09%. In May, it was the highest as 4.94%, and in July, it was the lowest as 3.24%. 4. It is intended to conduct constant follow-up research on estimating university dormitory building's power consumption unit cost and examining the generation efficiency and load rate of the BIPV system.

AC PDP에서 CLHS 구동 방법에 의한 ITO Gap에 따른 방전 특성 (The Characteristics of the Discharge According to ITO Gap by the CLHS Driving Method in AC PDP)

  • 신재화;최명규;김근수
    • 전기학회논문지
    • /
    • 제62권1호
    • /
    • pp.83-89
    • /
    • 2013
  • In order to reduce the power consumption in international standard IEC62087, the luminance efficiency should be improved at the low discharge load rather than at the high discharge load. Thus, this paper analysed the characteristics of the discharge at the panels with ITO Gap of $65{\mu}m$, $80{\mu}m$, and $100{\mu}m$ in 50-inch PDP with FHD resolution. It was well known that the long gap panel improves the luminance and the luminous efficiency. However, it is very difficult to drive the panel due to high driving voltage. When the normal driving method was applied at the panel with ITO gap of $100{\mu}m$, the phenomenon of the double peak was generated in the sustain period. We confirmed that main factor of the double peak is the self-erasing discharge. When the CLHS driving method was applied at the panel with ITO gap of $100{\mu}m$, the self-erasing discharge was improved in the sustain period. Also, the $V_S$ and $V_A$ minimum voltage of the CLHS driving method decreased about 9V and 12V compared with those of the normal driving method. Moreover, when the CLHS driving method was applied to the panel with ITO gap of $100{\mu}m$, the luminance and the luminous efficiency increased compared with those of the normal driving method. The luminance and the luminous efficiency greatly increased at the low discharge load. The less discharge load, the higher increase rate of the luminance and the luminous efficiency. Especially, the luminous efficiency at ITO gap of $100{\mu}m$ increased about 26.3% at the discharge load of 4% compared with that at ITO gap of $65{\mu}m$.

생물막공법을 이용한 도시하수처리에 관한 연구 (A Study on the Municipal Wastewater Treatment Using Biofilm Process)

  • 곽병찬;탁성제;김남천;황용우
    • 상하수도학회지
    • /
    • 제14권1호
    • /
    • pp.62-75
    • /
    • 2000
  • Most of biological treatment to remove contaminants in municipal wastewater have been conducted by activated sludge process. But, the process have several probIems such as enormous site needed for construction of treatment facilities, unstable treatment due to limited ability to control load fluctuation, frequent sludge bulking and appearance of lots of surplus sludge. In this study, the experiments were performed through submerging biofilm of PEPP media in existing aeration tank with raw water from municipal wastewater treatment plant and then submerging PVDC and PEPP media, different from shape and chemical peculiarity in anoxic reactor. Throughout the experience, nutrient removal efficiency according to HRT, nitrogen phosphorous removal efficiency, behavior of nitrogen and dewatering efficiency have been compared and analysed with those of activated sludge process. As the results, BOD removal efficiency according to BOD volumetric load and F/M ratio was not found any differency in two processes, but was decreased below 90% as going along the condition of high load in activated sludge process. Kinetic coefficient was $K_{max}=1.162day^{-1}$, $K_s=53.77mg/L$, $Y=0.166mgVSS/mgBOD_{rem}$. and $K_d=0.019day^{-1}$. It was found that the removal efficiency, even though in aerobic condition, in biofilm process equipped anoxic reactor was higher than the one in activated sludge process within the range of 70~80%, and became better as HRT increased. Phosphorous removal efficiency was not found any differency in two processes. In biofilm process, treament efficiency even in conditions of high load was not decreased, because the biomass concentration could be maintained in high condition compared with activated sludge process. As HRT increased, suspended and attached biomass was increased and the other hand, F/M ratio was decreased as biomass' increasing. Biomass thickness was increased. from $10.43{\mu}m$ to $10.55{\mu}m$ as HRT increased and density of biomass within $40.79{\sim}41.16mg/cm^2$. The results also present that the dewatering efficiency of sludge generated in biofilm process was higher than in activated sludge process, and became better as HRT increased.

  • PDF

부하 임피던스 변화에 따른 6.78MHz 전류모드 D급 전력증폭기 특성 해석 (Performance Analysis of 6.78MHz Current Mode Class D Power Amplifier According to Load Impedance Variation)

  • 고석현;박대길;구경헌
    • 한국항행학회논문지
    • /
    • 제23권2호
    • /
    • pp.166-171
    • /
    • 2019
  • 본 논문은 6.78 MHz무선전력전송 송신기의 전송 효율을 높이고 송수신 코일 간격 변화에도 안정적 특성을 확보하기 위해 전류 모드 클래스 D 전력증폭기를 설계한다. 선형증폭기의 이론적인 효율을 제한하는 트랜지스터의 기생 커패시터 성분에 의한 손실을 적게 만들어 전력증폭기의 효율을 향상시킨다. 회로 설계 시뮬레이터를 이용하여 고효율 증폭기를 설계하고 부하 임피던스 변화에 따른 전력 출력, 효율 특성을 시뮬레이션하여 검증하였다. 시뮬레이션에서 DC 바이어스 30 V일 때 42.1 dBm의 출력과 95%의 효율을 갖도록 설계하였다. 전력증폭기를 제작하여 42.1 dBm (16 W)의 출력에서 91%의 효율을 보였다. 드론 무선전력전송에 적용될 송수신 코일을 제작하였으며, 송수신 코일 간격에 따른 부하변화에 따라 전력부가효율이 최대 88% 이고 출력전력 $42.1dBm{\pm}1.7dB$의 특성을 나타내었다.

A 82.5% Power Efficiency at 1.2 mW Buck Converter with Sleep Control

  • Son, Chung Hwan;Byun, Sangjin
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권6호
    • /
    • pp.842-846
    • /
    • 2016
  • This paper presents a DC-DC buck converter which uses a sleep control to improve the power efficiency in a few mW light load condition. The sleep control turns off analog controller building blocks to reduce the static power losses during the off-duty period of pulse width modulation. For verification, a buck converter has been implemented in a $0.18{\mu}m$ CMOS process. The power efficiency has been improved from 76.7% to 82.5% with a 1.2 mW load. The maximum power efficiency is 95% with a 9 mW load.

시계열 모델을 이용한 행동기반 에너지 효율화 프로그램의 고객기준부하 산정 방안 (Customer Baseline Load Calculation using Time Series Prediction Technique in Energy Efficiency Programs)

  • 고세현;주성관;이재희;문국현;위영민
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.19-26
    • /
    • 2019
  • As global demand for energy, energy prices, and power generation has increased worldwide, the government is turning to supply-oriented electricity supply and demand policies, such as behavior-based energy efficiency programs. In order to measure the implementation effect of the behavior-based energy efficiency program, the energy reduction must be accurately calculated by calculating the customer baseline load.