• Title/Summary/Keyword: Load cycle

Search Result 1,008, Processing Time 0.026 seconds

Analysis of Mechanical Properties and Stress Crack Behavior of HOPE Geomembranes by Laboratory Installation Damage Test (실내 시공시 손상시험에 의한 HDPE 지오멤브레인의 기계적 특성 및 응력균열거동 해석)

  • Khan, Belas Ahmed;Park, Ju-Hee;Kim, Sung-Hee;Chang, Yong-Chai;Oh, Tae-Hwan;Lyoo, Won-Seok;Jeon, Han-Yong
    • Polymer(Korea)
    • /
    • v.35 no.3
    • /
    • pp.203-209
    • /
    • 2011
  • Two smooth and textured surfaced HDPE geomembranes (GMs) were cut into dumbbell shape and notched where depth of the notch produced a ligament thickness of 10% to 90% of the nominal thickness with the specimen at 10% interval. A series of laboratory simulation test for installation damage were carried out at different loading cycles on HDPE GMs in accordance with ISO 10722 test method and the effect of number of loading cycle on installation damage was compared. It was found that yield stress and elongation at yield point decreased gradually as the notch depth was increased. Both installation damaged and notched, GMs were used to understand stress crack behavior and this behavior was observed through NCTL test at $50{\pm}1^{\circ}C$ at different yield stresses immerging in pH 4 and pH 12 buffer solutions. Over 35% tensile load, GMs became vulnerable to stress cracking. Both damaged and notched GMs showed the same trend. Especially, notched GMs showed less strength than installation damaged GMs at every stress cracking test condition.

Design of Indoor Electric Moving and Lifting Wheelchair with Minimum Rotation Radius and Obstacle Overcoming (최소 회전반경 및 장애물 극복형 실내 전동 이·승강 휠체어의 설계)

  • Kim, Young-Pil;Ham, Hun-Ju;Hong, Sung-Hee;Ko, Seok-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.415-424
    • /
    • 2019
  • In this paper, a minimum rotation radius was designed and fabricated to overcome the threshold so that elderly or disabled people who have difficulty moving can move and transfer safely and conveniently in a narrow room. In the indoor environment, where the sedentary culture develops, this study aimed to provide convenience for passengers with fracture diseases, geriatric diseases, and other knee and waist diseases. First, links, seats, armrests, covers, motors, batteries, chargers, controllers, etc. were attached to the frame so that they could be moved and lifted indoors. The product design and structure were designed considering the user's environment and physical characteristics, and IoT functions were added. A driving experiment was performed to confirm the operating performance of the manufactured indoor moving and lifting wheelchair. The performance tests, such as continuous running time, turning radius, maximum actuator load, maximum lift height, sound pressure level, minimum sensing distance of the driving aid sensor, interworking of server and app programs, device compatibility, and duty cycle error rate, were performed. As a result of the test, the built-in wheelchair could achieve the performance test target of each item and operate successfully.

International Research Status on Spent Nuclear Fuel Structural Integrity Tests Considering Vibration and Shock Loads Under Normal Conditions of Transport (정상운반조건의 진동 및 충격하중을 고려한 사용후핵연료의 구조적 건전성 시험평가 해외연구현황)

  • Lim, JaeHoon;Cho, Sang Soon;Choi, Woo-seok
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.2
    • /
    • pp.167-181
    • /
    • 2019
  • Currently, the development of evaluation technology for vibration and shock load characteristics and spent nuclear fuel structural integrity under normal conditions of transport is being conducted in the Republic of Korea. This is the first such research conducted in the Republic of Korea and, thus, previous international studies need to be investigated and will be referred to in the ongoing project. Before 2000, several studies related to measurement of vibration and shock loads on spent nuclear fuel were conducted in the US. US national research institutes conducted uniaxial fuel assembly shaker tests, concrete block tests, and multi-axis fuel assembly tests between 2009 and 2016. In 2017, multi-modal transportation tests including road, sea, and rail transport were also performed by research institutes from the US, Spain and the Republic of Korea. Therefore, test preparation procedures, acceleration and strain measurement results, and finite-element and multi-body dynamics analysis were investigated. Based on the measured strain data, the preliminary conclusion was obtained that the measured strain was too small to cause damage to spent nuclear fuel rods. However, this conclusion is a preliminary conclusion that only reviews part of the results; a detailed review is being conducted in the US. The investigation of international studies on spent nuclear fuel structural integrity tests considering vibration and shock loads under normal conditions of transport in the US will be useful data for the project being conducted in the Republic of Korea.

Effect of Voltage Range and Number of Activation Cycles in the Activation Process of a Polymer Electrolyte Fuel Cell (고분자 전해질 연료전지의 활성화과정에서 전압 범위 및 활성화 횟수의 영향)

  • Donggeun Yoo;Sohyeong Oh;Sunggi Jung;Jihong Jeong;Kwonpil Park
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.58-61
    • /
    • 2023
  • The activation process is essential for PEMFC to improve initial performance. The most commonly used activation method is a voltage change (load change) method, which may accompany degradation of the electrode catalyst if excessively performed. In many activation processes, the voltage change range is activated in a wide range from 0.4 V to OCV, and research is needed to reduce the voltage change range in order to prevent electrode catalyst degradation and shorten the activation time. Therefore, in this study, when the activation voltage range was 0.4~0.6 V, 0.4~0.8 V, and 0.4~OCV, we tried to research and develop an effective activation method by analyzing the performance and characteristics of the electrode and polymer membrane. The performance improvement was the lowest in the activation with a wide voltage range from 0.4 V to the highest OCV, and the performance decreased by 10% when activated for 56 cycles. The 0.4~0.6 V activation cycle showed the highest performance improvement up to 20% and the smallest decrease in performance due to overactivation, indicating that it is optimal method.

Microbial Growth in Dried Fishes During Preservation (건어물 저장 중 미생물 증식상태에 관한 연구)

  • 이현자;김종군;이수정;조한옥
    • Journal of Food Hygiene and Safety
    • /
    • v.8 no.3
    • /
    • pp.135-140
    • /
    • 1993
  • Dried fishes such as dried pollack, dried sliced squid, dried white bait, dried anchoy) and dried cod used to cook Korean traditional foods were airpacked in polyethylene tube and irradiated with 7 kGy of gamma-ray source. The effect of gamma irradiation on microbial growth in dried fishes was investigated during storage at ambient temperature for 12 months. The total aerobic bacteria in the control group were contaminated by $3.9{\times}10^{3}\;cells/g$ in dried pollack, $5.6{\times}10^{5}\;cells/g$ in dried sliced squid, $1.2{\times}10^{5}\;cells/g$ in dried white bait, $1.2{\times}10^{4}\;cells/g$ in dried anchovy and $1.2{\times}10^{4}\;cells/g$ in dried cod and 7 kGy irradiation could eliminate the bacteria and also reduce aerobic bacterial load to 1~3 log cycle and no apparent growth of microorganisms occurred during storage. Molds in the control group were contaminated by $4.0{\times}10^{2}\;cells/g$ in dried pollack, $$1.3{\times}10^{2}\;cells/g$ in dried sliced squid, $2.5{\times}10^{2}\;cells/g$ in dried white bait, 90 cells/g in dried anchovy and $2.0{\times}10^{2}\;cells/g$ in dried cod, respectively. 7 kGy irradiation could sterilize the molds and the growth of molds of nonirradiated samples were slightly decreased during storage. Yeasts in the control group were contaminated by $1.4{\times}10^{3}\;cells/g$ in dried poUack, 75 cells/g in dried sliced squid, $1.1{\times}10^{3}\;cells/g$ in dried white bait, 50 cells/g in dried anchovy, $1.6{\times}10^{2}\;cells/g$ in dried cod, respectively and irradiation could sterilize the yeasts and growth of yeasts was slightly decreased in dried pollack and dried white bait but increased in order of dried anchovy, dried cod and dried sliced squid. Coliforms in all sample were sterilized by irradiation and its growth was decreased during storage except dried anchovy.

  • PDF

The Effects of Eco-friendly Design of Dishwashing Detergent on Product's Carbon Emission Reduction (친환경 설계로 제조된 주방세제의 탄소배출량 감축 효과)

  • Kim, Jong Seok;Kim, Won Chan;Lee, Yong Ju;Kim, Heung Sik;Park, Heon Young;Yang, Bong Sig;Kim, Wan Soo;Park, Pil Ju;Hong, Eun Ah
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.2
    • /
    • pp.87-91
    • /
    • 2015
  • As negative effects of climate change have been visualized and its direct damages to economy have been realized, the global efforts to respond to climate change by reducing greenhouse gas emission were accelerated. Korea's Carbon Footprint Labeling gets a lot of attention as one of the effective methods to contribute to national GHG reduction goal, and for enterprises to show customers how much effort the company put into global warming prevention. Consumers' interest on low-carbon products has been increasing. This study uses Life Cycle Assessment method to calculate the amount of carbon emission of dishwashing detergent, LG Household & Healthcare, which reduced carbon emissions by using raw materials that has relatively lower environment load. Life Cycle Assessment Method is based on guidelines of Carbon Footprint Labeling, Ministry of Environment, and pre-manufacturing, manufacturing, and disposal phase are included while use phase of the product is excluded from assessment. In order to understand the effects of eco-design on carbon emissions, the dishwashing detergent's carbon emissions are compared before and after the change of main raw materials. The result shows the improvement from $0.47kgCO_2eq/kg$ to $0.38kgCO_2eq/kg$ per product, and this means the main raw materials' carbon emissions could be reduced by around 9.4%, which is equivalent to 916tons of GHG emissions per year.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Clinical Characteristics and Comparison of the Various Methods Used for the Diagnosis of the New Influenza A Pandemic in Korea (한국에서의 2009 신종 인플루엔자 A의 임상양상과 다양한 진단 방법들의 비교)

  • Kwon, Min Jung;Lee, Chang Kyu;Roh, Kyoung Ho;Nam, Myung Hyun;Yoon, Soo Young;Lim, Chae Seung;Cho, Yun Jung;Kim, Young Kee;Lee, Kap No
    • Laboratory Medicine Online
    • /
    • v.1 no.1
    • /
    • pp.26-34
    • /
    • 2011
  • Background: Laboratory diagnosis of new influenza A (H1N1) is crucial for managing patients and establishing control and prevention measures. We compared the diagnostic accuracies of the real time RT-PCR (rRT-PCR) test recommended for the confirmation of the new flu and the viral culture method used conventionally for viral disease with that of the rapid antigen test (RAT). Methods: We performed RAT, R-mix culture, and real-time PCR by using 861 respiratory samples collected from December 2009 to January 2010 and evaluated the abilities of these methods to detect new influenza A. The relationship among the positive rates of RAT, grades of culture, and the cycle threshold (Ct) values of rRT-PCR was also evaluated. Results: Of the 861 patients, 308 (35.8%) were diagnosed with new influenza A. The sensitivities, specificities, positive predictive values, and negative predictive values of the tests were respectively as follows: 59.7%, 99.5%, 98.4%, and 81.6% for RAT; 93.2%, 100%, 100%, and 96.3% for R-mix culture; and 95.8%, 100%, 100%, and 97.7% for rRT-PCR. Samples with weak positive grade in culture and those with Ct values of 30-37 in rRT-PCR showed positivities as low as 25.3% and 2.3% in RAT, respectively. The hospitalization rate and death rate of the confirmed patients were 3.2% and 0.3%, respectively, and gastrointestinal symptoms were observed in 7.2% of the patients. Conclusions: R-mix culture and rRT-PCR tests showed excellent reliability in the diagnosis of new influenza A and could be very useful, especially for samples with low viral load.

Contamination of the Mushim-Cheon and its Countermeasures;I. Analysis of the Water Samples in Summer (무심천 수질 오염 실태와 그 방지책;I. 하계절의 수질 오염 분석)

  • Lee, Jea-Koo;Kyung, Kee-Sung;Kim, Hak-Nam;Oh, Kyeong-Seok
    • Korean Journal of Environmental Agriculture
    • /
    • v.9 no.1
    • /
    • pp.23-37
    • /
    • 1990
  • In order to disclose the contamination of the Mushim-Cheon by pollutants in August and September of 1989 and to establish countermeasures, the collected water samples were analyzed to obtain the following results : 1. The water temperature of the period ranged from 25.8 to $30.8^{\circ}C$ acceptable for the growth of microorganisms and algae to allow the self-purification of the stream. 2. The pHs at the sites during the same period ranged from 6.5 to 8.5 which fall within the allowed values for the first grade water supplies except for site 14. 3. At site 18 which is the confluence of the sewer of the excretion disposal facilities and the main stream, the DO was observed to fall down to 0.7 ppm in September. 4. The BOD value reached a maximum of 62.1 ppm at site 18, which far exceeded the limit of 40 ppm, the allowed value for the discharges from the disposal facilities. In addition, the SS values were 200 and 520 ppm in August and September, respectively, which were three to seven times as high as the allowed limit of 70 ppm. 5. The high $NH_3-N$ value of 46.2 ppm at site 18 in September suggested that the water was heavily contaminated with excretions. 6. The BOD load of the sewage from site 12, the Sajik-Dong Sewer, in September was estimated to be about 0.306 ton/day. 7. The contamination of the influents, the family wastewater, and the discharges from the disposal facilities was greater than that of the main stream. 8. In the samples collected from site 12, the Sajik-Dong sewer at an interval of every two hours, a close correlation was observed between the pollutant load and the life cycle of the nearby inhabitants. 9. Compared with the results obtained from the water samples in 1979, it was observed that the water was heavily contaminated at site 12 (the Sajik-Dong Sewer, under the Chung Ju Great Bridge) and site 15 (Under the 2nd Uncheon Bridge) over the last 10 years, with little difference at site 9(Young Un-Dong water supply source).

  • PDF

Analysing the effect of impervious cover management techniques on the reduction of runoff and pollutant loads (불투수면 저감기법의 유출량 및 오염부하량 저감 효과 분석)

  • Park, Hyung Seok;Choi, Hwan Gyu;Chung, Se Woong
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.1
    • /
    • pp.16-34
    • /
    • 2015
  • Impervious covers(IC) are artificial structures, such as driveways, sidewalks, building's roofs, and parking lots, through which water cannot infiltrate into the soil. IC is an environmental concern because the pavement materials seal the soil surface, decreasing rainwater infiltration and natural groundwater recharge, and consequently disturb the hydrological cycle in a watershed. Increase of IC in a watershed can cause more frequent flooding, higher flood peaks, groundwater drawdown, dry river, and decline of water quality and ecosystem health. There has been an increased public interest in the institutional adoption of LID(Low Impact Development) and GI(Green Infrastructure) techniques to address the adverse impact of IC. The objectives of this study were to construct the modeling site for a samll urban watershed with the Storm Water Management Model(SWMM), and to evaluate the effect of various LID techniques on the control of rainfall runoff processes and non-point pollutant load. The model was calibrated and validated using the field data collected during two flood events on July 17 and August 11, 2009, respectively, and applied to a complex area, where is consist of apartments, school, roads, park, etc. The LID techniques applied to the impervious area were decentralized rainwater management measures such as pervious cover and green roof. The results showed that the increase of perviousness land cover through LID applications decreases the runoff volume and pollutants loading during flood events. In particular, applications of pervious pavement for parking lots and sidewalk, green roof, and their combinations reduced the total volume of runoff by 15~61 % and non-point pollutant loads by TSS 22~72 %, BOD 23~71 %, COD 22~71 %, TN 15~79 %, TP 9~64 % in the study site.