• Title/Summary/Keyword: Load characteristic experiment

Search Result 148, Processing Time 0.028 seconds

An Experimental Study of the Lap Splice Performance with Rib Effect (철근의 마디 형상에 따른 겹침이음 성능 실험)

  • Seo, Min-Choul;Hong, Geon-Ho;Choi, Oan-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.35-36
    • /
    • 2010
  • This research investigated the bond characteristic by lap splice experimental which has change relative area on rib variation of reinforcing bar. As a result has similar load-deflection curve with existing experiment, Maximum yield strength and displacement is increase.

  • PDF

Experimental Study on Combustion Characteristics of Live Fire Load in a Bookstore (서점의 적재가연물의 연소특성에 관한 실험적 연구)

  • Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.47-53
    • /
    • 2011
  • Fire load in buildings greatly contribute to the time and scale of fire according to the type and quantity of the fire load. Because bookstores have a large quantity of fire load compared with other buildings which may lead to large scale fires, however, their heat release characteristics have been hardly investigated. In this study, to obtain the data applicable for the performance-based fire safety design of bookstores, the specimens representing stacked fire loads were heated in a furnace in compliance with the standard heating curve of ISO834-1:1999 to investigate their heat release characteristics. From the experiment result, the combustion velocity and heat release rate required for performancebased fire safety designs are obtained.

A Study on Crushing Characteristic of Hatted Section Tube (모자형 단면부재의 압괴특성 연구)

  • 김천욱;한병기;김병삼
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.2
    • /
    • pp.212-219
    • /
    • 2002
  • In the frontal collision of cars, front parts of cars such as engine rail and side members that are composed of hatted section tubes should absorb most of the collision energy far the passenger compartment not to be deformed. For these reasons the study on the collapse characteristics, maximum crushing load and energy absorption capacity of hatted section tubes are needed. In this study, top hatted section tubes and double hatted section tubes are investigated. The maximum crushing load of hatted section tubes is induced from plastic buckling stress of plates by considering that the hatted section tubes are composed of plates with each different boundary conditions and that its material has a strain hardening effect. On this concept maximum crushing load equations of hatted section tubes are derived and verified by experiments. from the results of experiment, the differences of collapse characteristics between top hatted section tube and double hatted section tube are analysed. And mean crushing loads of hatted section tubes from experiments are compared with other theory.

A Study on Load Simulator for Traction system combined testing (전동차 조합시험을 위한 부하 시뮬레이터에 관한 연구)

  • Kim, Gil-Dong;Lee, Han-Min;Oh, Seh-Chan;Pak, Sung-Hyuk;Kim, Jong-Dae
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1643-1645
    • /
    • 2005
  • A newly-built inverter has to undergo a series of stress tests in the final stage of production line. This can be achieved by connecting it to a dynamometer consisting of a three-phase machine joined by a rigid shaft to a DC load machine. The latter is controlled to create some specific load characteristic needed for the test. In this paper a test method is proposed, in which no mechanical equipment is needed. The suggested test stand consists only of a inverter to be tested and a simulator converter. Both devices are connected back- to-back on the AC-side via smoothing reactors. The simulator operates in real-time as an equivalent load circuit, so that the device under test will only notice the behaviour of a three-phase machine under consideration of the load. In odor to wove rightness of the suggested test method, the simulation and actural experiment rallied out emulation for a 2.2kW induction motor.

  • PDF

Numerical Simulation on the Greenwater Impact Load of Offshore Structure in Regular Waves (규칙파 중 해양구조물의 갑판침입수 충격하중에 관한 수치시뮬레이션)

  • Kang, Ui-Ha;Lee, Young-Gill;Yang, In-Jun;Kim, Ki-Yong;Joo, Young-Seok;Park, Jeong-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.6
    • /
    • pp.492-500
    • /
    • 2017
  • In the study, numerical simulation on the greenwater impact load of free surface offshore structure in the regular waves using fixed cartesian grid system and Modified Marker-Density (MMD) method were carried out and the results were reviewed. In order to compare numerical simulation and experimental results, the FPSO with the scale ratio of 1/100 model ship with fixed rectangular deck was selected and turbulence characteristic of the flow was considered by applying the Sub-Grid Scale (SGS) in laminar flow. As a result, it is reviewed how the greenwater impact load inflowed from bow in regular headsea wave influence the flow on the deck and the flow characteristic by numerical simulation and the experiment results were compared and reviewed. Based on this study, it would be useful to numerically study the effect of greenwater on offshore structure.

A Characteristic Analysis of the Parallel Resonant DC-DC Converter Using ZVS (ZVS를 이용한 부하병렬 공진형 DC-DC 컨버터의 특성해석)

  • Hwang, Gye-Ho;Nam, Seung-Sik;Oh, Kyeong-Seob;Kang, Jin-Wook;Kim, Dong-Hee;Ro, Chae-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1026-1028
    • /
    • 2001
  • In this paper, proposal circuit proposes that load parallel resonant DC-DC Converter consist of L and C resonant tank circuit. Also, the capacitor$(C_1,\;C2)$ connected in switch are a common using by resonance capacitor and ZVS capacitor. The analysis of proposed circuit uses normalized parameter and characteristic estimation which is needed in each step before design is generally described the proposed circuit with the characteristics of average power and average output voltage etc. Alse, we conform a rightfulness theoretical analysis by comparing a theoretical values and experimental values obtained from experiment using MOSFET as switching devices.

  • PDF

Characterization of LED Lighting according to Voltage Variation (전압변동에 따른 LED 조명의 특성분석)

  • Lee, Dae-Woo;Lee, Jong-Pil;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.271-276
    • /
    • 2014
  • LED lighting has received worldwide attention as advantages, such as environment-friendly than the conventional light, the excellent energy efficiency, and a semi-permanent lifetime. The use of the SMPS increased with the rapid growth in the LED industry. Increased use of SMPS means an increase in the harmonic generation load. Therefore, LED lighting compared with conventional fluorescent lamps were tested in this paper for characterized by a light source, electrical and harmonic characteristics. Experiments results for LED lighting showed different characteristics from the existing fluorescent lamp. Especially harmonic characteristic results showed different characteristics in accordance with the power device manufacturing method for LED lighting.

Heat Load Characteristics of Sea Water Cooling Apparatus on Inshore Fishing Boat (연근해 어선용 해수냉각장치의 열부하특성)

  • 한인근;문춘근;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.1317-1323
    • /
    • 2001
  • The circumstance is giving the blow against fishermen with the incoming-decreasing and the difficulty of crew's supply & demand and management. In addition, the depression of the external situation like the departure of WTO system and the plan of EEZ proclaim is forcing fishery into improving their fishing condition. By this international and domestic circumstance, development of the sea water cooling apparatus for fish hold storage is demanded sincerely. First of all, we Investigated load characteristics which based on development of sea water cooling system and optimum fish hold storage. The experimental results is as follows. In creasing the speed of compressor and mass blew rate of refrigerant, the temperature of NaCl solution is low. And the load characteristics experiment on fish hold storage outlet is as fellows. As time goes by, increasing the mass flow rate of NaCl solution, temperature difference between inlet and outlet is small in a model of fish hold storage. These results provide many useful informations applicable to an actual design of sea water cooling system and optimum fish hold storage.

  • PDF

Comparison of Characteristics between $L_1-B_4$ mode and $L_1-B_8$ mode Ultrasonic Motors ($L_1-B_4$모드와 $L_1-B_8$모드 초음파 선형 전동기의 특성 비교)

  • U, Sang-Ho;Kim, Dong-Yeon;Kim, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1518-1520
    • /
    • 2002
  • Purpose of this research compares best transfer speed about applied frequency and voltage using characteristic of $L_1-B_4$ mode and $L_1-B_8$ mode linear ultrasonic motor that use piezoelectric effect. By method of study, analyzed best transfer speed measuring and comparison load status that use actuality telephone card in $L_1-B_4$ mode linear ultrasonic motor and no-load status of $L_1-B_8$ mode linear ultrasonic motor. Experiment result is applied frequency(58.4Hz) in $L_1-B_4$ mode linear ultrasonic motor (load state) and the best transfer speed by 19.8[cm/s] at applied voltage(56V) point. Also, $L_1-B_8$ mode linear ultrasonic motor (no-load state) is best transfer speed by applied frequency(27.9kHz) and 32.96[cm/s] at applied voltage (50V) point.

  • PDF

Analysis of Operation Performance of a Micro Gas Turbine Generator System (마이크로 가스터빈 발전시스템의 운전성능 분석)

  • Lee, J. J.;Kim, T. S.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.5 s.32
    • /
    • pp.13-21
    • /
    • 2005
  • This study aims to analyze operating performance of a micro gas turbine with the aid of detailed measurements of various system parameters. In addition to embedded measurements, parameters such as exhaust temperatures, engine inlet temperatures and fuel flow rates are measured. Variations in measured data and estimated performance parameters are analyzed. Those data are processed to calculate losses along the power transmission line and the net gas turbine performance (power and efficiency based on the gas turbine shaft end) is isolated from the overall system performance. A method to estimate characteristic parameters such as component efficiencies, based on the comparison between measured and predicted performance data, is suggested and exemplified for the full load condition.