• 제목/요약/키워드: Load capacitance

검색결과 159건 처리시간 0.024초

The far-end crossta1k voltage for CMOS-IC load

  • Miyao, Nobuyuki;Noguchi, Yasuaki;Matsumoto, Fujihiko
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.1878-1881
    • /
    • 2002
  • The capacitance of nonlinear component such as a CMOS inverter varies largely around the threshold voltage. We measured the far-end crosstalk of two parallel microstrip lines with the CMOS inverter load near the threshold voltage of the CMOS inverter, The negative voltage of the crosstalk agrees with that for a 4pF capacitor toad. The positive voltage of the crosstalk hardly changes of the amplitude of the input step voltage.

  • PDF

최소 지연시간을 갖는 CMOS buffer 회로의 설계 기법 (the Design Methodology of Minimum-delay CMOS Buffer Circuits)

  • 강인엽;송민규;이병호;김원찬
    • 대한전자공학회논문지
    • /
    • 제25권5호
    • /
    • pp.509-521
    • /
    • 1988
  • In the designs of integrated circuits, the buffer circuits used for driving a large capacitive load from minimum-structured logic circuit outputs have important effects upon system throughputs. Therefore it is important to optimize the buffer circuits. In this paper, the principle of designing CMOS buffer circuits which have the minimum delay and drive the given capacitive load is discussed. That is, the effects of load capacitance upon rise time, fall time, and delay of the CMOS inverter and the effects of parasitic capacitances are finely analysed to calculate the requested minimum-delay CMOS buffer condition. This is different from the method by C.A. Mead et. al.[2.3.4.]which deals with passive-load-nMOS buffers. Large channel width MOS transistor stages are necessary to drive a large capacitive load. The effects of polysilicon gate resistances of such large stages upon delay are also analysed.And, the area of buffer circuits designed by the proposed method is smaller than that of buffer circuits designed by C.A. Mead's method.

  • PDF

집단에너지 공동주택의 사용자 측 열부하 예측에 의한 열공급제어 알고리즘 개발에 관한 연구 (A Study on Development of Heat Supply Control Algorithm of Consumer Group Energy Apartment Building by Prediction of Heating Load)

  • 변재기;이규호;최영돈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1300-1305
    • /
    • 2009
  • The energy conservation in buildings affects environmental preservation as well as economic benefits, and creates the comfortable indoor environment set for the inhabitants. Especially, apartment buildings show ever-increasing energy consumption with large-sized and high-class tendency, thus energy saving counterplans are needed. The present study is to develop an optical control algorithm by using heating load curve according to the outdoor temperature change. Heating load analysis should be performed before the present method can be applied. Dynamic heating load simulations are performed by resistance-capacitance method. Results show that heating load decrease linearly according to the increase of outdoor temperature.

  • PDF

A Load Identification Method for ICPT System Utilizing Harmonics

  • Xia, Chen-Yang;Zhu, Wen-Ting;Ma, Nian;Jia, Ren-Hai;Yu, Qiang
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2178-2186
    • /
    • 2018
  • Online identification of load parameters is the premise of establishing a stable and highly-efficient ICPT (Inductive Coupled Power Transfer) system. However, compared with pure resistive load, precise identification of composite load, such as resistor-inductance load and resistance-capacitance load, is more difficult. This paper proposes a method for detecting the composite load parameters of ICPT system utilizing harmonics. In this system, the fundamental and harmonic wave channel are connected to the high frequency inverter jointly. The load parameter values can be obtained by setting the load equation based on the induced voltage of secondary-side network, the fundamental wave current, as well as the third harmonic current effective value received by the secondary-side current via Fourier decomposition. This method can achieve precise identification of all kinds of load types without interfering the normal energy transmission and it can not only increase the output power, but also obtain higher efficiency compared with the fundamental wave channel alone. The experimental results with the full-bridge LCCL-S type voltage-fed ICPT system have shown that this method is accurate and reliable.

전극의 용량성분을 이용한 공진이득 증폭형 유전가열장치에 관한 연구 (A study on a dielectric heating system for amplifying the resonant gain using the capacitance of electrodes)

  • 김신효;이창우;배한나;조대권
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권9호
    • /
    • pp.940-946
    • /
    • 2015
  • 본 논문에서는 300kHz 이상의 주파수를 사용하는 고전압펄스의 출력이득을 증폭시키는 방법에 대하여 고찰하였다. 종래의 파워스테이지의 전압을 상승시켜 펄스진폭(Pulse-amplitude)을 증폭하는 방식 대신에, 부하의 용량성분과 회로의 기생성분간의 공진을 이용하여 출력이득을 증폭하는 방식으로 연구가 진행되었다. 특히 브릿지형 대신에 Flyback Topology를 적용을 통하여 회로구성을 간소화하고, 출력펄스파형에 출력전극의 용량성분을 부여함에 따라 부하에 가해지는 출력전압의 이득을 증폭시킴으로써, 하드스위칭을 통한 출력회로 내에서의 과부하 및 발열에 따른 손상을 막을 수 있는 장점이 있다. 해당연구는 의료 및 산업용가열분야에 적용되는 유전가열 방식의 접촉형 가열기기의 공간적, 전기적 효율을 제고할 수 있는 한 방법을 제시한다.

Design and simulation of an RCN Controller to improve steady state behavior of a self-excited induction generator

  • Garg, Anjali;Sandhu, Kanwarjit Singh;Saini, Lalit Mohan
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권4호
    • /
    • pp.464-471
    • /
    • 2012
  • Self-excited induction generators (SEIG) are gaining importance as compared to conventional generators due to their capability toconvert wind energy into electrical energy for a wide range of variation in operating speed. The performance of such a generator depends upon the load, rotor speed and excitation capacitance. Therefore, depending upon the operating conditions, the output voltage and frequency of this machine goes on changing and this imposes a restriction on its usage. In order to maintain constant voltage and frequency, it need controllers, which make the circuit complicated and also increases the overall cost of power generation. This paper presents a simple controller to regulate the output voltage and frequency of SEIG for variation in its operating conditions due to any change in load, rotor speed and excitation capacitance (R, N, C) and their combination. The controller presented is simple in design, user friendly and is also less expensive, as the elements used in the controller are only resistors, inductors and capacitors. A block of SEIG for steady state operation is also modeled and presented in this paper. SEIG, Controller and other components are modeled and simulated using Matlab/Simulink.

자여자 풍력 유도발전기의 캐패시터에 따른 고조파 전류의 증폭 (Amplification of Current Harmonics Due to Self-Excitation Capacitors for Wind Induction Generators)

  • 오용;최용성;황종선;이경섭
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.192-197
    • /
    • 2008
  • The value of this paper is to use reduced size apparatuses to perform field measurement in order to identify and validate that the harmonic-current effects are due to the presence of self-excitation capacitance connected at stator's terminals of the studied SEIG. This paper has presented the measured electrical quantities of a three-phase $\Delta$-connected wind induction generator (WIG) under sudden connection and disconnection of resistive loads. An intelligent power-system recorder/monitor has been employed to measure three-phase voltages and currents of the studied system at the terminals of the studied WIG and the load. The measured electrical quantities have been analyzed. Total harmonic distortion (THD) of current using cumulative probability density function has been employed to determine the penetration of harmonic distortion at load side. The results show that the harmonic currents generated by the studied WIG can be severely amplified by the connected self-excited capacitance at the stator's terminals.

Analysis and design of voltage doubling rectifier circuit for power supply of neutron source device towards BNCT

  • Rixin Wang;Lizhen Liang;Congguo Gong;Longyang Wang;Jun Tao
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2395-2403
    • /
    • 2024
  • With the rapid development of DC high voltage accelerator, higher requirements have been raised for the design of DC high voltage power supply, requiring more stable high voltage with lower output ripple. Therefore, it also puts forward higher requirements for the parameter design of the voltage doubling rectifier circuit, which is the core component of the DC high voltage power supply. In order to obtain output voltage with better performance, the effects of the working frequency, the stage capacitance and the load resistance on the output voltage of the voltage doubling rectifier circuit are studied in detail by simulation. It can be concluded that the higher the working frequency of the transformer, the larger the stage capacitance, the larger the load resistance and the better the output voltage performance in a certain range. Based on this, a 2.5 MV voltage doubling rectifier circuit driven by a 120 kHz frequency transformer is designed, developed and tested for the power supply of the neutron source device towards BNCT. Experimental results show that this voltage doubling rectifier circuit can satisfy the design requirements, laying a certain foundation for the engineering design of DC high voltage power supply of neutron source device.

고성능 CMOS LDO 레귤레이터 설계 (Design of a High-Performance CMOS LDO Regulator)

  • 심상미;박준규;강현철;유종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.187-188
    • /
    • 2007
  • This paper describes a simple and high-performance LDO regulator designed using a $0.18{\mu}m$ CMOS process. It is designed to provide a regulated voltage for on-chip small loads instead of for off-chip heavy loads. Since the load capacitance is very small in this applications, the frequency compensation can be easily achieved without a buffer. The designed LDO drives a load current up to 15mA and dissipates only 12uA quiescent current. The line regulation is and the load regulation is for a 9mA load step. The PSRR at 10kHz is 54dB.

  • PDF

정전용량을 이용한 미분탄 유량계의 개발 (The Development of Pulverized Coal(PC) Flow-Meter using Capacitance)

  • 김재현;이용식;황건호;정성원;여준호;소지영
    • 조명전기설비학회논문지
    • /
    • 제22권4호
    • /
    • pp.61-67
    • /
    • 2008
  • 본 논문은 발전소 보일러 및 제철소 고로의 미분탄 연소방식에 적용이 가능한 유량계 개발에 관한 연구로, 정전 용량을 이용한 미분탄 유량계를 개발하였다. 먼저 관에 흐르는 미분탄의 밀도 측정이 가능한 센서 및 회로를 설계하였고, 측정된 데이터를 분석하고 밀도를 계산하는 알고리즘을 구현하였다. 압송시스템에 설치된 로드셀의 출력 데이터와 측정된 데이터를 비교하여 개발된 유량계의 신뢰성을 확인하였다.