• 제목/요약/키워드: Load capacitance

검색결과 158건 처리시간 0.024초

Design Guidelines for a Capacitive Wireless Power Transfer System with Input/Output Matching Transformers

  • Choi, Sung-Jin
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1656-1663
    • /
    • 2016
  • A capacitive wireless power transfer (C-WPT) system uses an electric field to transmit power through a physical isolation barrier which forms a pair of ac link capacitors between the metal plates. However, the physical dimension and low dielectric constant of the interface medium severely limit the effective link capacitance to a level comparable to the main switch output capacitance of the transmitting circuit, which thus narrows the soft-switching range in the light load condition. Moreover, by fundamental limit analysis, it can be proved that such a low link capacitance increases operating frequency and capacitor voltage stress in the full load condition. In order to handle these problems, this paper investigates optimal design of double matching transformer networks for C-WPT. Using mathematical analysis with fundamental harmonic approximation, a design guideline is presented to avoid unnecessarily high frequency operation, to suppress the voltage stress on the link capacitors, and to achieve wide ZVS range even with low link capacitance. Simulation and hardware implementation are performed on a 5-W prototype system equipped with a 256-pF link capacitance and a 200-pF switch output capacitance. Results show that the proposed scheme ensures zero-voltage-switching from full load to 10% load, and the switching frequency and the link capacitor voltage stress are kept below 250 kHz and 452 V, respectively, in the full load condition.

정전용량 수분센서의 배지 함수량 정량화 (Quantification of Rockwool Substrate Water Content using a Capacitive Water Sensor)

  • 백정현;박주성;이호진;안진희;최은영
    • 생물환경조절학회지
    • /
    • 제30권1호
    • /
    • pp.27-36
    • /
    • 2021
  • 정전용량 수분측정 센서는 수경용 배지 양쪽에 구리 및 테플론으로 절연된 전극판(30cm×10cm)을 부착하여 배지의 넓은 부분에 걸쳐 측정하도록 개발되었다. 본 연구는 콘덴서형 정전용량 센서로부터 출력되는 정전용량 값을 배지 함수량으로 변환하는 것이다. 정량화 실험은 양액을 공급하면서 배지 물무게와 정전용량 변화를 측정하고 그 값을 비교하는 방식으로 수행되었다. 배지 함수량과 정전용량은 본 연구를 위해 특별히 개발된 소프트웨어와 함께 센서와 로드셀을 사용하여 20~30초마다 측정되었다. 상용 curve-fitting 프로그램을 이용하여 배지 함수량과 정전용량을 변수로 정전용량 값으로 배지 함수량을 추정하였다. 공급하는 물의 양이 증가하면 정전용량도 증가하는 경향을 보였다. 배지 내 물무게에 따른 정전용량에 대한 변동계수(coefficient of variation, cv)는 배지 내 물무게가 1.0kg 수준에서 다른 무게에 비해 높아 함수량 보정은 물무게를 1.7~6.0kg 수준에서 수행하였다. 정전용량과 물무게 사이의 상관 계수는 0.996이었고 보정식에 의해 정전용량으로 추정된 함수량은 로드셀로 측정한 배지 함수량과 비교하였다.

Dynamic Simulation of Annual Energy Consumption in an Office Building by Thermal Resistance-Capacitance Method

  • Lee, Chang-Sun;Choi, Young-Don
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.1-13
    • /
    • 1998
  • The basic heat transfer process that occurs in a building can best be illustrated by an electrical circuit network. Present paper reports the dynamic simulation of annual energy consumption in an office building by the thermal resistance capacitance network method. Unsteady thermal behaviors and annual energy consumption in an office building were examined in detail by solving the simultaneous circuit equations of thermal network. The results are used to evaluate the accuracy of the modified BIN method for the energy consumption analysis of a large building. Present thermal resistance-capacitance method predicts annual energy consumption of an office building with the same accuracy as that of response factor method. However, the modified BIN method gives 15% lower annual heating load and 25% lower cooling load than those from the present method. Equipment annual energy consumptions for fan, boiler and chiller in the HVAC system are also calculated for various control systems as CAV, VAV, FCU+VAV and FCU+CAV. FCU+CAV system appears to consume minimum annual energy among them.

  • PDF

A Design Guide of 3-stage CMOS Operational Amplifier with Nested Gm-C Frequency Compensation

  • Lee, Jae-Seung;Bae, Jun-Hyun;Kim, Ho-Young;Um, Ji-Yong;Sim, Jae-Yoon;Park, Hong-June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제7권1호
    • /
    • pp.20-27
    • /
    • 2007
  • An analytic design guide was formulated for the design of 3-stage CMOS OP amp with the nested Gm-C(NGCC) frequency compensation. The proposed design guide generates straight-forwardly the design parameters such as the W/L ratio and current of each transistor from the given design specifications, such as, gain-bandwidth, phase margin, the ratio of compensation capacitance to load capacitance. The applications of this design guide to the two cases of 10pF and 100pF load capacitances, shows that the designed OP amp work with a reasonable performance in both cases, for the range of compensation capacitance from 10% to 100% of load capacitance.

Comparative Study on the Structural Dependence of Logic Gate Delays in Double-Gate and Triple-Gate FinFETs

  • Kim, Kwan-Young;Jang, Jae-Man;Yun, Dae-Youn;Kim, Dong-Myong;Kim, Dae-Hwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제10권2호
    • /
    • pp.134-142
    • /
    • 2010
  • A comparative study on the trade-off between the drive current and the total gate capacitance in double-gate (DG) and triple-gate (TG) FinFETs is performed by using 3-D device simulation. As the first result, we found that the optimum ratio of the hardmask oxide thickness ($T_{mask}$) to the sidewall oxide thickness ($T_{ox}$) is $T_{mask}/T_{ox}$=10/2 nm for the minimum logic delay ($\tau$) while $T_{mask}/T_{ox}$=5/1~2 nm for the maximum intrinsic gate capacitance coupling ratio (ICR) with the fixed channel length ($L_G$) and the fin width ($W_{fin}$) under the short channel effect criterion. It means that the TG FinFET is not under the optimal condition in terms of the circuit performance. Second, under optimized $T_{mask}/T_{ox}$, the propagation delay ($\tau$) decreases with the increasing fin height $H_{fin}$. It means that the FinFET-based logic circuit operation goes into the drive current-dominant regime rather than the input gate load capacitance-dominant regime as $H_{fin}$ increases. In the end, the sensitivity of $\Delta\tau/{\Delta}H_{fin}$ or ${{\Delta}I_{ON}}'/{\Delta}H_{fin}$ decreases as $L_G/W_{fin}$ is scaled-down. However, $W_{fin}$ should be carefully designed especially in circuits that are strongly influenced by the self-capacitance or a physical layout because the scaling of $W_{fin}$ is followed by the increase of the self-capacitance portion in the total load capacitance.

Marx 펄스발생기를 응용한 소형 고전압 급준 펄스 발생장치 (Fast Rise Time High Voltage Pulse Generator Applying The Marx Generator)

  • 박승록;정석환;김진규;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권2호
    • /
    • pp.72-78
    • /
    • 2001
  • A compact size high voltage pulse generator with nanosecond rise time has been designed and investigated experimentally. The inductance of a pulse generator can be reduced by fixing the Marx generator and pulse forming network components into a single cylindrical unit. As a result, nanosecond rise time about $8{\sim}10[ns]$ and pulse width of several hundred [ns] can be obtained from a modified Marx pulse generator. And parametric studies showed that the rise time of the output pulse was depended little on the change of the load resistance and the charging capacitance while, the pulse width of the output pulse was depended greatly upon the change of the load resistance and the charging capacitance. The theoretical showed the possibility to design the laboratory-size pulse generator very fast rising time and a proper pulse width by minimizing stray inductance and varying resistance and capacitance.

  • PDF

Generalized State-Space Modeling of Three Phase Self-Excited Induction Generator For Dynamic Characteristics and Analysis

  • Kumar Garlapati Satish;Kishore Avinash
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권4호
    • /
    • pp.482-489
    • /
    • 2006
  • This paper presents the generalized dynamic modeling of self-excited induction generator (SEIG) using state-space approach. The proposed dynamic model consists of induction generator; self-excitation capacitance and load model are expressed in stationary d-q reference frame with the actual saturation curve of the machine. An artificial neural network model is implemented to estimate the machine magnetizing inductance based on the knowledge of magnetizing current. The dynamic performance of SEIG is investigated under no load, with the load, perturbation of load, short circuit at stator terminals, and variation of prime mover speed, variation of capacitance value by considering the effect of main and cross-flux saturation. During voltage buildup the variation in magnetizing inductance is taken into consideration. The performance of SEIG system under various conditions as mentioned above is simulated using MATLAB/SIMULINK and the simulation results demonstrates the feasibility of the proposed system.

비선형부하에 대한 전해 커패시터의 특성 해석과 커패시턴스 용량 추정 알고리즘 (A Characteristic Analysis and Capacitance Estimation Algorithm of Electrolytic Capacitor for Non-linear Loads)

  • 손진근
    • 한국ITS학회 논문지
    • /
    • 제8권6호
    • /
    • pp.180-186
    • /
    • 2009
  • DC/DC 컨버터 등의 전력변환장치와 같은 비선형부하에 대해 알루미늄 전해 커패시터는 에너지의 일시적 저장이나 전압 평활용으로 많이 사용되고 있다. 그러나 전해 커패시터는 사용 시간이 늘어나면서 온도 상승 및 전해액(electrolyte)의 증발 등으로 인하여 고장이 매우 빈번하게 나타난다. 따라서 본 논문에서는 이러한 사고에 대한 고장모드를 분류하고 이를 진단하기 위한 사전 단계로 전해 커패시터의 주파수 변화에 따른 특성 해석과 이를 바탕으로 한 커패시턴스 용량 추정 알고리즘을 제안하였다. 기본파에 해당하는 저주파의 주파수 분석 결과에 따른 모의 실험의 결과는 제안한 알고리즘의 타당성을 입증하였다.

  • PDF

표면 탄성파 장치를 이용한 용량성 부하의 신호처리 및 이를 이용한 초정밀 간극 측정 (Signal Processing of Capacitive Load and Gap Measurement with High Precision Using Surface Acoustic Wave Device)

  • 김재근;이택주;임수철;박노철;박영필;박경수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.376-380
    • /
    • 2009
  • Surface acoustic wave (SAW) device is widely used as a bandpass filter, a chemical or physical sensor, and an actuator. In this paper, we propose the capacitive gap measurement system with high precision through the signal processing using SAW device. The research process is mainly composed of theoretical part and experimental part. In theoretical part, equivalent circuit model was used to simulate the SAW response by the change of capacitance. In experimental part, commercialized capacitor was used to see the SAW response by the change of load capacitance. After that, gap adjustment system was made physically and the SAW response by the change of gap which caused the capacitance change was measured. And resolution and stroke was decided comparing the signal change and basic measurement noise level.

  • PDF

열저항-열용량법에 의한 사무실용 건물의 소비에너지 해석 (Analysis of energy consumption of office building by thermal resistance-capacitance method)

  • 이창선;최영돈
    • 설비공학논문집
    • /
    • 제9권1호
    • /
    • pp.1-13
    • /
    • 1997
  • This paper reports the dynamic analysis of energy consumption for an office building by heat resistance-capacitance method. If a building is divided into several wall components and the wall components is replaced by one thermal capacitance and several thermal resistances, the building becomes an electric circuit. By solving the simultaneous equations of the circuit, the dynamic heat transfer characteristics and the energy consumption rate of the building were predicted. Accuracy of modified BIN method was evaluated by the present resistance-capacitance method. The result shows that modified BIN method overpredicts the heating load of the office building 15%. Annual energy consumptions of equipments(fan, boiler, chiller) for various ventilating control system(CAV, VAV, FCU+VAV, FCU+CAV) were compared. FCU+CAV shows the minimum annual energy consumption.

  • PDF