• 제목/요약/키워드: Load Transfer

검색결과 1,614건 처리시간 0.027초

마이크로파일의 하중전이특성 및 지지성능 분석 (Load transfer characteristics and bearing capacity of micropiles)

  • 구정민;최창호;조삼덕;이기환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.899-904
    • /
    • 2009
  • This paper presents the analysis result of load-transfer mechanism and pile movements associated with the development of frictional resistance to understand the engineering characteristics of micropile behavior. An field load tests were performed for two different types of micropiles and they are (i) thread bar reinforcement with D=50mm and (ii) hollow steel pipe reinforcement with $D_{out}$=82.5mm and $D_{in}$=60.5mm and wrapped with woven geotextile for post-grouting. The load test results indicated that micropiling with pressured grouting provided better load-transfer characteristics than micropiling with gravity grouting under both compressive and tensile loading conditions in that unit skin frictional resistance is well distributed along installation depth. The unit weight and unconfined compressive strength of cured grout were obtained for each piling method. The strength and unit weight of micropile with pressured grouting was higher than those with gravity grouting. The fact that load bearing quality with pressured grouting is better than that of gravity grouting could be attributed to the dense mutual adhesion between surrounding ground and pile due to pressurized grouting method and better grout quality.

  • PDF

풍화암에 지지된 현장타설말뚝의 3차원 해석 (3D FE Analysis of Cast-in-situ Concrete Pile embedded in Weathered Rock)

  • 김상백;이활;권오균;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.167-172
    • /
    • 2000
  • In this study, the behaviors of a cast-in-situ concrete pile embedded in the weathered rock were analysed by a 3D numerical analysis using PENTAGON 3D and the results were compared with those of the field load test. The load-settlement relation and the load transfer relationship were evaluated from the numerical analysis. As a result, the load-settlement relation at the pile top and the axial load distribution with depth were predicted reasonably. And those results were similar with those of the field load test.

  • PDF

쇄석기의 충격하중 정량화에 대한 연구 (A Study on the Impact Load Quantification of the Jaw Crusher)

  • 홍성주;양해정
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권2호
    • /
    • pp.1-7
    • /
    • 2019
  • Jaw crusher is a device that breaks rock collected from mines or quarries to produce aggregates of the size desired by user. A representative method for measuring load is to measure them by attaching force sensors directly to the part where the load is generated. However, the direct method has many limitations such as high-impact loads generation in equipment or space constraints, sensor capacities and costs. Therefore, Transfer Path Analysis (TPA) was used to indirectly measure impact loads by attaching acceleration sensors. In this study, both direct and TPA methods were used to measure the impact load of Jaw crusher. This study finally quantifies the impact of the load generated by the Jaw crusher using direct method and TPA method, and comparing the impact load measured calculated the derive the error rate.

현장타설말뚝의 하중전이 특성에 대한 실험 및 해석적 연구 (An Experimental Study and Numerical Analysis on Load Transfer Characteristics of Drilled Shafts)

  • 박언상;박승도
    • 한국지반환경공학회 논문집
    • /
    • 제24권1호
    • /
    • pp.5-14
    • /
    • 2023
  • 본 연구에서는 설계 대상인 현장타설말뚝기초에 대하여 상사율을 고려한 하중전이 대형토조 모형시험과 3차원 수치해석을 수행함으로써 현장타설말뚝 선단부와 주면부의 하중전이 특성을 분석하고 하중분담율을 산정하였다. 대형토조 모형시험 및 3차원 수치해석 결과에서 나타난 현장타설말뚝의 선형적 거동으로부터, 본 연구의 설계 조건에 대한 주면하중전이곡선은 Baquelin 등의 제안식, 선단하중전이곡선은 Baquelin 등의 제안식, 수평하중전이곡선은 Reese 등의 제안식이 적정한 것으로 확인되었다. 암반근입부에서 축하중은 시험값이 수치해석값보다 약간 크게 측정되었지만 암반 근입부에서 하중분담율은 연직하중이 증가함에 따라 평균적으로 약 27.8%의 분담율을 나타내었다. 연직재하 시에 말뚝두부의 침하량은 해석값이 시험값보다 약간 작게 평가되었으며, 모형시험 및 해석 최대 연직하중에서 말뚝두부의 최대 침하량은 시험치 10.6mm, 해석치 10.0mm 이고, 말뚝선단에서 최대 침하량은 시험치 2.0mm, 해석치 1.9mm로 나타났다. 수평재하 시에 기둥 두부(지표)와 말뚝 두부에서 수평변위는 시험값과 해석값이 비교적 잘 일치하는 것으로 나타났고, 모형토조시험 결과 최대 수평변위 38.0mm에서 측정된 수평하중은 24,713kN, 수치해석에서의 수평하중은 26,073kN으로 평가되었다.

줄눈형식에 따른 공항 콘크리트 포장 하중전달율 비교 (Comparison with Load Transfer Efficiency for Joint Types in Airport Concrete Pavements)

  • 안지환;전성일;권수안;김민우
    • 한국도로학회논문집
    • /
    • 제16권3호
    • /
    • pp.9-20
    • /
    • 2014
  • PURPOSES : This study is to compare load transfer efficiency of key joint and dowel joint for airport concrete pavement. METHODS : As AC150/5320-6D of FAA's [Advisory Circular] was changed into AC150/5320-6E, Key joint type of rigid pavement were excluded from Construction Joints. LTE(Load Transfer Efficiency) of dowel joint and key joint were compared by times and seasons through pavement temperature measurement, ocular investigation and HWD measurement. RESULTS : For the joint performance grade of No. 2(The second) runway of airport, 12% of poor rate was observed in key joint and 2% of poor rate in dowel joint. Poor rate of key joint was increased to 17%, if only No. 3~No. 6 slabs, which are mostly loaded from the airplanes, were applied for the study. In apron area, LTE poor rate of key joint was high in winter, and LTE poor rate of dowel joint was at least above 'Fair' grade. In summer, 'Fair' for key joint, 'Acceptable' for dowel joint appeared. CONCLUSIONS : As results, dowel joint was superior than key joint for LTE. Deviations of seasons and times were smaller in dowel joint's result. And LTE in winter was lower than LTE in summer.

Load transfer and energy absorption in transversely compressed multi-walled carbon nanotubes

  • Chen, Xiaoming;Ke, Changhong
    • Coupled systems mechanics
    • /
    • 제6권3호
    • /
    • pp.273-286
    • /
    • 2017
  • We present a simple and easy-to-implement lumped stiffness model to elucidate the load transfer mechanism among all individual tube shells and intertube van der Waals (vdW) interactions in transversely compressed multi-walled carbon nanotubes (CNTs). Our model essentially enables theoretical predictions to be made of the relevant transverse mechanical behaviors of multi-walled tubes based on the transverse stiffness properties of single-walled tubes. We demonstrate the validity and accuracy of our model and theoretical predictions through a quantitative study of the transverse deformability of double- and triple-walled CNTs by utilizing our recently reported nanomechanical measurement data. Using the lumped stiffness model, we further evaluate the contribution of each individual tube shell and intertube vdW interaction to the strain energy absorption in the whole tube. Our results show that the innermost tube shell absorbs more strain energy than any other individual tube shells and intertube vdW interactions. Nanotubes of smaller number of walls and outer diameters are found to possess higher strain energy absorption capacities on both a per-volume and a per-weight basis. The proposed model and findings on the load transfer and the energy absorption in multi-walled CNTs directly contribute to a better understanding of their structural and mechanical properties and applications, and are also useful to study the transverse mechanical properties of other one-dimensional tubular nanostructures (e.g., boron nitride nanotubes).

$L_1-B_4$모드와 $L_1-B_8$모드 초음파 선형 전동기의 특성 비교 (Comparison of Characteristics between $L_1-B_4$ mode and $L_1-B_8$ mode Ultrasonic Motors)

  • 우상호;김동연;김진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1518-1520
    • /
    • 2002
  • Purpose of this research compares best transfer speed about applied frequency and voltage using characteristic of $L_1-B_4$ mode and $L_1-B_8$ mode linear ultrasonic motor that use piezoelectric effect. By method of study, analyzed best transfer speed measuring and comparison load status that use actuality telephone card in $L_1-B_4$ mode linear ultrasonic motor and no-load status of $L_1-B_8$ mode linear ultrasonic motor. Experiment result is applied frequency(58.4Hz) in $L_1-B_4$ mode linear ultrasonic motor (load state) and the best transfer speed by 19.8[cm/s] at applied voltage(56V) point. Also, $L_1-B_8$ mode linear ultrasonic motor (no-load state) is best transfer speed by applied frequency(27.9kHz) and 32.96[cm/s] at applied voltage (50V) point.

  • PDF

스펙트럴 전달행렬에 의한 헬리컬 기어계의 진동해석 (Vibration Analysis of the Helical Gear System by Spectral Transfer Matrix)

  • 박찬일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.774-781
    • /
    • 2006
  • This paper presents a study on the analytical prediction of vibration transmission from helical gears to the bearing. The proposed method is based on the application of the three dimensional helical gear behaviors and complete description of shaft by the spectral method. Helical gear system used in this paper consists of the driving element, helical gears, shafts, bearings, couplings and load element. In order to describe all translation and rotation motion of helical gears twelve degree of freedom equations of motion by the transmission error excitation are derived. Using these equations, transfer matrix for the helical gear is derived. For the detail behavior of shaft motion, the $12{\times}12$ transfer matrix for the shaft is derived. Transfer matrix for the bearing, coupling, driving element, and load is also derived. Application of the boundary conditions in the assembled transfer matrix produces the forces and displacements in each element of the helical gear system. The effect of the proposed method is shown by numerical example.

  • PDF

Shear transfer mechanisms in composite columns: an experimental study

  • De Nardin, Silvana;El Debs, Ana Lucia H.C.
    • Steel and Composite Structures
    • /
    • 제7권5호
    • /
    • pp.377-390
    • /
    • 2007
  • In the design of concrete filled composite columns, it is assumed that the load transfer between the steel tube and concrete core has to be achieved by the natural bond. However, it is important to investigate the mechanisms of shear transfer due to the possibility of steel-concrete interface separation. This paper deals with the contribution of headed stud bolt shear connectors and angles to improve the shear resistance of the steel-concrete interface using push-out tests. In order to determine the influence of the shear connectors, altogether three specimens of concrete filled composite column were tested: one without mechanical shear connectors, one with four stud bolt shear connectors and one with four angles. The experimental results showed the mechanisms of shear transfer and also the contribution of the angles and stud bolts to the shear resistance and the force transfer capacity.

사례분석에 기초한 말뚝시공법 및 재하시험방법에 따른 하중지지특성에 관한 연구 (A Study on the Load Bearing Characteristics Depending on Pile Construction Methods and Pile Load Test Methods Based on Case Analyses)

  • 홍석우;최용규
    • 한국지반공학회논문집
    • /
    • 제28권4호
    • /
    • pp.5-21
    • /
    • 2012
  • 국내의 경우 종래의 말뚝기초의 설계에서는 주로 선단지지력에만 의존하는 설계가 이루어져 왔으나 현장에서 실제 크기 말뚝에 대한 하중전이측정실험이 이루어진 이후 많은 하중전이측정실험 자료들을 통하여 마찰력이 크게 발휘되는 것이 밝혀져 왔다. 본 연구에서는 항타강관말뚝 및 대구경 현장타설말뚝의 재하시험 시 측정된 축하중전이 사례들을 분석하여 재하시험방법에 따른 말뚝기초의 하중지지양상을 구명하였다. 사례 말뚝들의 평균마찰력 분담율을 말뚝의 종류, 재하시험방법, 상대근입길이, 말뚝의 직경, 지반의 종류 등의 함수로 상관관계를 나타내는 것은 곤란하였다. 평균 마찰력 분담율은 50% 이상을 상회하는 것으로 나타나고 있었으므로 사례 말뚝기초는 대체로 마찰지지말뚝으로 거동하는 경우가 많은 것을 볼 수 있었으며 극히 일부 사례말뚝은 혼합지지말뚝으로 거동하였다.