• Title/Summary/Keyword: Load Re-distribution

Search Result 47, Processing Time 0.034 seconds

The Application of Load Re-configuration Using Genetic Algorithm for the Distribute Systems Mischance (배전계통 사고시 부하절체 방법의 GA 적용에 관한 연구)

  • Choi, Dae-Seub;Sin, Ho-Chul
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.1
    • /
    • pp.115-123
    • /
    • 2011
  • Distribution system loss minimization re-configuration is 0-1 planning problem, and the number of combinations requiring searches is extremely large when dealing with typical system scales. For this reason, the application of a genetic algorithm (GA) seems a tractive to solve this problem. Although Genetic algorithms are a type of random number search method, they incorporate a multi-point search feature and are therefore superior to one-point search techniques. The incorporate of GAs for solving large combinational problem has received wide attention. Further, parallel searching can be performed and the optimal solution is more easily reach ed. In this paper, for improving GA convergence characteristics in the distribution system loss minimization re-configuration problem, a chromosome "Limited Life" concept is introduced. Briefly, considering the population homogenization and genetic drift problems, natural selection is achieved by providing this new concept, in addition to natural selection by fitness. This is possible because individuals in a population have an age value. Simulation were carried out using a model system to check this method's validity.

Switching Surge Analysis of Vacuum Circuit breaker at the Power Plant distribution lines (발전소 비전계통 진공차단기의 스위칭 써지 해석)

  • Kim, Ik-Mo;Kim, Ji-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.305-308
    • /
    • 2001
  • The first objective of this study is to set up the switching surge analysis method in motor driving distribution system. The simplified model which can simulate the motor energization and circuit breaker re-ignitions, and each circuit element model is presented in this paper. The second objective is to calculate the quantify of surge over-voltage in real nuclear power station. And the surge suppressing measures are verified on the simulation basis. It is clarified that most cases are not satisfactory to meet the IEEE standard 522-1992 without using surge suppressing measures. In cases that the surge arrester are installed in distribution board at the load side of circuit breaker. The IEEE specification is fully met.

  • PDF

Reliability Evaluation of Electrical Distribution Network Containing Distributed Generation Using Directed-Relation-Graph

  • Yang, He-Jun;Xie, Kai-Gui;Wai, Rong-Jong;Li, Chun-Yan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1188-1195
    • /
    • 2014
  • This paper presents an analytical technique for reliability evaluation of electrical distribution network (EDN) containing distributed generation (DG). Based on hierarchical levels of circuit breaker controlling zones and feeder sections, a directed-relation-graph (DRG) for an END is formed to describe the hierarchical structure of the EDN. The reliability indices of EDN and load points can be evaluated directly using the formed DRG, and the reliability evaluation of an EDN containing DGs can also be done without re-forming the DRG. The proposed technique incorporates multi-state models of photovoltaic and diesel generations, as well as weather factors. The IEEE-RBTS Bus 6 EDN is used to validate the proposed technique; and a practical campus EDN containing DG was also analyzed using the proposed technique.

A Re-Configuration Genetic Algorithm for Distribution Systems (배전계통에서 유전적 알고리즘을 이용한 접속변경순서결정방법)

  • Choi, Dai-Seub
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.490-491
    • /
    • 2004
  • Recently, sectionalizing switches have been coming to be operated by remote control through the distribution SCADA system. However, the problem of determining the optimal switching sequence is a combinatorial optimization problem, and is quite difficult to solve. Hence, it is imperative to develop practically applicable solution algorithms for this problem. Several efficient algorithms have been developed for finding approximate solutions to such problems. these algorithms create a new arbitral distribution system configuration from an initial configuration, and some of these algorithms do not show a load transfer sequence to reach the objective system.

  • PDF

Implementing a Dielectric Recovery Strength Measuring System for Molded Case Circuit Breakers

  • Cho, Young-Maan;Rhee, Jae-ho;Baek, Ji-Eun;Ko, Kwang-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1752-1758
    • /
    • 2018
  • In a low-voltage distribution system, the molded case circuit breaker (MCCB) is a widely used device to protect loads by interrupting over-current; however the hot gas generated from the arc discharge in the interrupting process depletes the dielectric recovery strength between electrodes and leads to re-ignition after current-zero. Even though the circuit breaker is ordinarily tripped and successfully interrupts the over-current, the re-ignition causes the over-current to flow to the load again, which carries over the failure interruption. Therefore, it is necessary to understand the dielectric recovery process and the dielectric recovery voltage of the MCCB. To determine these characteristics, a measuring system comprised of the experimental circuit and source is implemented to apply controllable recovery voltage and over-current. By changing the controllable recovery voltage, in this work, re-ignition is driven repeatedly to obtain the dielectric recovery voltage V-t curve, which is used to analyze the dielectric recovery strength of the MCCB. A measuring system and an evaluation technique for the dielectric recovery strength of the MCCB are described. By using this system and method, the measurement to find out the dielectric recovery characteristics after current-zero for ready-made products is done and it is confirmed that which internal structure of the MCCB affects the dielectric recovery characteristics.

The Study on the Method of Distribution of output according to Power Limit of Renewable Energy (재생에너지 출력제한에 따른 출력량 배분 방안 연구)

  • Myung, Ho-San;Kim, Se-Ho
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.173-180
    • /
    • 2019
  • There is a case where the output of renewable energy(RE) is curtailed due to an increase in the share of RE. Typically, wind power(WP) is curtailed due to oversupply and low load at midnight. However there is a case where the output of WP is limited during daytime due to the increase in share of photovoltaic(PV). In current electricity market, as the share of PV is increased, the curtailments of WP will be increased further, which will add to the difficulties of wind farm operators. In this paper, we propose a method to distribute the power limit of RE according to the criterion based on the priority constraint of the energy source which is difficult to operate the power system.

A Method of Determining B-coefficient Applying VDLM/LRDA (전압의존형 부하모델과 손실재분배 알고리즘을 적용한 B계수 산정법)

  • Chae, Myung-Suk;Lee, Myung-Hwan;Kim, Byung-Seop;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1183-1185
    • /
    • 1999
  • The basic purpose of economic dispatch problem is that minimize fuel cost with inequality constraint of generator output. To solve this problem it is very important to express power loss equation that have quadratic function of generator output power included B-coefficient. This Paper presents a method in determining B-coefficient by use A-matrix that is calculated by loss re-distribution algorithm (LRDA) considering voltage dependent load model (VDLM)s. The Proposed algorithm is tested with IEEE 6 bus sample system, which shows the result in each cases by the change of load component factor.

  • PDF

Distribution of Hot Tap Water Load for District Heating Substation with Hot Tap Water 2-Stage Heat Exchanger (급탕 2단열교환방식 지역난방 열사용시설의 급탕부하 분배에 관한 연구)

  • Jeong, Dong-Hwa;Kim, Joo-Wan;Baik, Young-Jin;Lee, Young-Soo;Chung, Dae-Hun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.297-302
    • /
    • 2011
  • According to the standards for district heating substation established by Korea District Heating Corporation, water heating supply systems at over 150 Mcal/h capacity must employ the 2-stage heat exchanger that improves the system efficiency by reusing the heat included in the return water of district heating system already used for space heating. In this paper, the operating characteristics of the system in accordance with the load distribution of two heat exchangers for pre-heating and re-heating cold city water are investigated. The results including mass flow rate, return temperature etc. help to manage district heating system economically.

Performance Analysis of a Combination of Carry-in and Remarshalling Algorithms

  • PARK, Young-Kyu;UM, Kyung-Ho
    • The Journal of Industrial Distribution & Business
    • /
    • v.11 no.10
    • /
    • pp.75-89
    • /
    • 2020
  • Purpose: The container terminal is an area that plays an important role in the country's import and export. As the volume of containers increased worldwide, competition between terminals became fiercer, and increasing the productivity of terminals became more important. Re-handling is a serious obstacle that lowers the productivity of terminal. There are two ways to reduce re-handling in the terminal yard. The first method is to load containers in terminal yards using effective carry-in algorithms that reduce re-handling. The second method is to carry out effective remarshalling. In this paper, the performance of various carry-in algorithms and various remarshalling algorithms are reviewed. Next, we try to find the most effective combination of carry-in algorithm and remarshalling algorithm. Research design, data and methodology: In this paper, we analyze the performance of the four carry-in algorithms, AP, MDF, LVF, RP and the four remarshalling algorithms, ASI, ASI+, ASO, ASO+. And after making all the combinations of carry-in algorithms and remarshalling algorithms, we compare their performance to find the best combination. To that end, many experiments are conducted with eight types of 100 bays through simulation. Results: The results of experiments showed that AP was effective among the carry-in algorithms and ASO+ was effective among remarshalling algorithms. In the case of the LVF algorithm, the effect of carrying in was bad, but it was found to be effective in finding remarshalling solution. And we could see that ASI+ and ASO+, algorithms that carry out remarshalling even if they fail to find remarshalling solution, are also more effective than ASI and ASO. And among the combinations of carry-in algorithms and remarshalling algorithms, we could see that the combination of AP algorithm and ASO+ algorithm was the most effective combination. Conclusion: We compared the performance of the carry-in algorithms and the remarshalling algorithms and the performance of their combination. Since the performance of the container yard has a significant effect on the performance of the entire container terminal, it is believed that the results of this experiment will be effective in improving the performance of the container terminal when carrying-in or when remarshalling.

Switching Surge Analysis of Vacuum Circuit breaker using EMTP (EMTP를 이용한 진공차단기의 스위칭 써지 해석)

  • Kim, Ik-Mo;Kim, Ji-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2008-2010
    • /
    • 2000
  • The first objective of this study is to set up the switching surge analysis method in motor driving distribution system. The simplified model which can simulate the motor energization and circuit breaker re-ignitions. and each circuit element model is presented in this paper. The second objective is to calculate the quantity of surge over-voltage in real nuclear power station. And the surge suppressing measures are verified on the simulation basis. It is clarified that most cases are not satisfactory to meet the IEEE standard 522-1992 without using surge suppressing measures. In cases that the surge arrester are installed in distribution board at the load side of circuit breaker. The IEEE specification is fully met.

  • PDF