• 제목/요약/키워드: Load Power Factor

검색결과 844건 처리시간 0.028초

The Implementation of Storage Type Power Flow Controller using Battery Storage

  • Leung, K.K.;Sutanto, D.
    • Journal of Power Electronics
    • /
    • 제1권2호
    • /
    • pp.99-106
    • /
    • 2001
  • This paper describes the implementation of a Storage Power Flow Controller (SPFC) connected to the grid which can provide concomitant benefits associated with a Unified Power Flow Controller while at the same time providing several other very important benefits to power system operation such as, load leveling dynamic voltage stability inprovement, harmonic compensation and power factor correction. This Storage power Flow Controller (SPFC) was implemented using real time signal processors, three-phase inverter(s) and battery bank which can provide improved power system operation and control, added system security and reduced power system losses.

  • PDF

Assessment of capacity curves for transmission line towers under wind loading

  • Banik, S.S.;Hong, H.P.;Kopp, Gregory A.
    • Wind and Structures
    • /
    • 제13권1호
    • /
    • pp.1-20
    • /
    • 2010
  • The recommended factored design wind load effects for overhead lattice transmission line towers by codes and standards are evaluated based on the applicable wind load factor, gust response factor and design wind speed. The current factors and design wind speed were developed considering linear elastic responses and selected notional target safety levels. However, information on the nonlinear inelastic responses of such towers under extreme dynamic wind loading, and on the structural capacity curves of the towers in relation to the design capacities, is lacking. The knowledge and assessment of the capacity curve, and its relation to the design strength, is important to evaluate the integrity and reliability of these towers. Such an assessment was performed in the present study, using a nonlinear static pushover (NSP) analysis and incremental dynamic analysis (IDA), both of which are commonly used in earthquake engineering. For the IDA, temporal and spatially varying wind speeds are simulated based on power spectral density and coherence functions. Numerical results show that the structural capacity curves of the tower determined from the NSP analysis depend on the load pattern, and that the curves determined from the nonlinear static pushover analysis are similar to those obtained from IDA.

변압기 및 인덕터 구성에 따른 특성 분석 (An analysis on the characteristic of inverter by the different factor both transformer and inductor)

  • 안교상;임희천;김신섭;황인호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1348-1350
    • /
    • 2002
  • This paper describes an efficient comparison of the different factor both transformer and inductor. And also the 3 kW class inverter was fabricated for the analysis of the Photovoltaic(PV) power system's performance. The result of the performance of the 3 kW inverter showed that the total harmonics distortion(THD) was 3.19%, the conversion efficiency of the inverter was above 90 % at an over half load, respectively.

  • PDF

단위 역률을 갖는 3상 강압형 다이오드 정류기에서 고조파 주입에 의한 DC 리플전압 저감 기법 (A DC Ripple Voltage Suppression Scheme by Harmonic Injection in Three Phase Buck Diode Rectifiers with Unity Power Factor)

  • 고종진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.305-308
    • /
    • 2000
  • A technique to suppress the low frequency ripple voltage of the DC output in three phase buck diode rectifiers is presented in this paper. The proposed pulse frequency modulation methods and duty ratio modulation methods are employed to regulate the output voltage of the buck diode rectifiers and guarantee zero-current -switching(ZCS) of the switch over the wide load range The proposed control methods used in this paper provide generally good performance such as low THD of the input line current and unity power factor. IN addition control methods can be effectively used to suppress the low frequency ripple voltage appeared in the dc output voltage. The harmonic injection technique illustrates its validity and effectiveness through the simulations.

  • PDF

기진회로를 이용한 사이크로콘버터에 의한 유도전동식 구동 (Cycloconverters with Resonant Circuits for Induction Motor Drives)

  • 김영석;조규민
    • 대한전기학회논문지
    • /
    • 제41권2호
    • /
    • pp.125-134
    • /
    • 1992
  • This paper presents a cycloconverter with an LC resonant circuit for an induction motor drive. The cycloconverter can keep input displacement factor at 1.0 by independently controlling real and reactive power under any load conditions. Furthermore it can keep power factor at about 1.0 since input and output current waveforms are nearly sinusoidal. Since it uses high frequency resonant circuit for commutation source, it can produce an output voltage of hundreds of hertz. Since it is also possible to make a system of high capacity using the cycloconverter, it is appropriate to drive motors with high speed and high capacity as well as general purpose motors, In this paper, we describe the operating principles of the cycloconverter and power control algorithms, and analyze its waveforms and present its characteristics. Expermental results are shown for the volts/hertz control of the induction motor and the validity of the proposed model is verified.

The Output Ripple Current of Single-Stage Flyback Converter with High Power Factor in LED Driver

  • Park, In-Ki;Eom, Hyun-Chul
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.347-349
    • /
    • 2013
  • This paper describes analysis and calculation of line frequency ripple current according to output capacitor value and effects of LED connection in the single stage flyback converter with high power factor. The low frequency output ripple current delivered from single stage converter has been analyzed in detail and the method evaluating parasitic resistance included in LED has been provided. In order to verify the equation derived in this paper, the single stage flyback converter has been designed with constant output current regulation with DCM operation. Experiments were conducted with different LED load structures to analyze the effect of LED parasitic resistance on output ripple current. As test results, the calculation can provide guide line to select capacitor values depending on output ripple current and LED characteristics.

  • PDF

소프트 스위칭 방식을 갖는 2㎾ PFC 컨버터의 분석 설계 및 실험 비교 (Analysis, Design and Experimental Comparison of 2㎾ Power Factor Corrector Converters With Soft-Switching Methods)

  • 박경수;김윤호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권9호
    • /
    • pp.537-544
    • /
    • 2002
  • This paper describes a comparative analysis of soft switching boost converters through design, production and experiment. Soft switching boost converters are designed to satisfy the condition of input voltage 170-265Vac, output voltage 400Vdc, output current 5A, output power 20W-2000W and unit power factor. In addition, parameter values are designed so that system operation can be compared under this is similar conditions. The efficiency of the combined inductor soft switching boost converter was 97.63% with 1011 load better than that of other boost converter types. The combined inductor soft switching converter has simple circuit construction and low switching loss. EMI resulted by the switching noise, and harmonic distortion.

역률개선을 위한 고효율 교류-직류 승압형 변환기 (A High Efficiency Single-Phase AC-DC Boost Converter for Power Factor Correction)

  • 박해동;윤덕용;홍순찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.117-120
    • /
    • 1998
  • This paper proposes a new high efficiency single-phase AC-DC boost converter for power factor correction. Lossless commutation circuit is interposed in the proposed converter for soft-switching. Due to this commutation circuit, the converter operates in 9 mode. In spite of changing input voltage and load, It attracts a constant DC output voltage because of the PWM control scheme using both the output voltage feedback and the input voltage feedforward. The converter is suitable for high power applications and operates in continuous conduction mode. In this paper, a 2.4[kW] converter is designed and simulated.

  • PDF

PFC 스위칭 정류기에서 손실인자에 의한 내부손실과 효율분석에 관한 연구 (A Study on the Internal Loss and Efficiency Analysis by Loss Factors in PFC Switching Rectifier)

  • 안태영
    • 반도체디스플레이기술학회지
    • /
    • 제23권2호
    • /
    • pp.50-54
    • /
    • 2024
  • In this paper, we propose a theoretical method to systematically analyze the power conversion efficiency of a single-phase PFC switching rectifier. Boost-type PFC was organized in order of highest correlation with load current using steady-state analysis results and introduced the concept of loss factor. The loss factors for each major element are summarized and presented in a table. This paper makes it easier to understand the internal loss and power conversion efficiency of the rectifier for loss factors. Lastly, to confirm the validity of the efficiency analysis results reflecting the loss factors, loss and efficiency analysis of the 2.5kW PFC rectifier was performed. The results were compared with data from a 2.5kW PFC circuit for evaluation. As a result, the usefulness of power conversion efficiency analysis reflecting the loss factors proposed in this paper was confirmed.

  • PDF

스마트그리드 빅데이터 기반 지역별 배전선로 부하손실 분석 (Regional Analysis of Load Loss in Power Distribution Lines Based on Smartgrid Big Data)

  • 조재훈;이해성;임한민;이병성;문채주
    • 한국전자통신학회논문지
    • /
    • 제17권6호
    • /
    • pp.1013-1024
    • /
    • 2022
  • 전력 계통에서 발생하는 부하손실은 전기품질 수준을 평가하는 지표로 활용되지만, 국내외 전력 유틸리티들의 수익 창출을 방해하는 가장 큰 요인이 된다. 따라서 전력 계통에서 발생하는 부하손실에 대한 정확한 분석은 매우 중요하다. 그러나 빠르게 증가하는 분산전원 연계로 인해 배전계통의 변동성이 증가하여 정확한 손실량을 계산해내는 것이 점점 어려워지고 있다. 본 논문에서는 분산전원 연계로 인해 배전선로에서 발생하는 부하손실의 더욱 정확한 산정을 위하여 스마트그리드 빅데이터 인프라를 구축하였다. 또한, 스마트그리드 빅데이터의 특성 중 하나인 '불확실성'을 제거하기 위한 데이터 전처리기법을 적용하여, 부하손실 분석의 정확도를 높였다. 본 논문에서 수행한 부하손실 분석 결과는 배전설비 투자계획 또는 안정적인 전력공급 신뢰성과 전력품질을 유지하기 위한 배전계통 운영계획에 기초자료로 활용될 수 있다.