• 제목/요약/키워드: Load Power Factor

검색결과 844건 처리시간 0.027초

3상 불평형 부하에 대한 입력 역률 개선 (THE POWER-FACTOR IMPROVEMENT FOR INPUT LINE OF THREE PHASE UNBALANCED LOAD)

  • 정연택;서영수;성대용;임영배;박상호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.421-424
    • /
    • 1990
  • In this parer, the parameter for control variable is consist of value that take measured the input line current and input total power-factor, and the compensation susceptance is calculated by its parameters. The compensator can reduce the reactive power generation by the system to zero, thus the input total power-factor is kept on sustaining the unit power- factor.

  • PDF

전력용 커패시터의 전기적 스트레스 해석 (Analysis for Electrical Stress of Power Capacitor)

  • 김종겸;박영진;이은웅;이동주
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.370-376
    • /
    • 2008
  • Power capacitors is widely used for power factor correction and component of passive filter in the user power systems. Recently, application of non-linear load is gradually increased. Non-linear load produces harmonic components of current. There are series resonance and parallel resonance when capacitors are applied in the user electrical application. If this harmonic component matches resonance, voltage and current is magnified and has severely an influences on capacitor. This paper purposes a new method for the magnitude of voltage and current by the frequency scan analysis without equivalent circuit for the actual circuit at the resonance condition.

싱글 로터리 컴프레셔의 온라인 부하 토크리플 보상기 (Online Load Torque Ripple Compensator for Single Rolling Piston Compressor)

  • 구본관
    • 전력전자학회논문지
    • /
    • 제19권5호
    • /
    • pp.457-462
    • /
    • 2014
  • Given their low cost, single rolling piston compressors (SRPC) are utilized in low-power room air-conditioning systems. The SRPC cycle is composed of one compression and discharge process per mechanical rotation. The load torque is high during the compression process of the refrigerants and low during the discharge process of the refrigerants. This load torque variation induces a speed ripple and severe vibration, which cause fatigue failures in the pipes and compressor parts, particularly under low-speed conditions. To reduce the vibration, the compressor usually operates at a high-speed range, where the rotor and piston inertia reduce the vibration. At a low speed, a predefined feed-forward load torque compensator is used to minimize the speed ripple and vibration. However, given that the load torque varies with temperature, pressure, and speed, a predefined load torque table based on one operating condition is not appropriate. This study proposes an online load torque compensator for SRPC. The proposed method utilizes the speed ripple as a load torque ripple factor. The speed ripple is transformed into a frequency domain and compensates each frequency harmonic term in an independent feed-forward manner. Experimental results are presented to verify the proposed method.

불평형 및 비선형부하 시 전력품질 향상을 위한 독립형 인버터의 전압제어 기법 (Voltage Control of Stand-Alone Inverter for Power Quality Improvement Under Unbalanced and Non-linear Load)

  • 이우종;조종민;차한주
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.567-575
    • /
    • 2016
  • This paper proposed the voltage control of stand-alone inverter for power quality improvement under unbalanced and non-linear load. The 3-phase DC-AC inverter controls CVCF(Constant Voltage Constant Frequency) and selective harmonic eliminate method in stand-alone mode by PR controller, and the stand-lone inverter supplies stable sinusoidal voltage to balanced, unbalanced and non-linear loads. The total harmonic distortion(THD) of line-to-line load voltage($V_{LL}$) is 1.2% in the balanced load. THD of $V_{LL}$ is reduced from 5.2% to 1.4% and 6.7% to 3.5%, respectively unbalanced and non-linear load. The stand-alone inverter can be supplies sinusoidal balanced voltage to unbalanced load because the voltage unbalanced factor(VUF) of $V_{LL}$ is reduced from 5.2% to 1.4% in the unbalanced load. Feasibility of control method for a stand-alone inverter will be verified through 30kW stand-alone inverter system.

철구조물의 설계방법에 대한 비교 연구 (Comparative Study of Design Methods for Manufacturing of Steel Structure)

  • 김동권;최재승;황석환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.357-362
    • /
    • 2000
  • Allowable stress design(ASD) method has been widely used to design steel structures such as boiler and heat recovery steam generator(HRSG) of power plant. However, many researchers are recently intrested in road and resistance factor design(LRFD) method which may take the place of ASD. In this work, the weight calculation of steel structure was compared when ASD and LRFD were applied respectively. For the calculation of weight of steel structure, computer program was developed and applied to obtain beam weight. Using this program and GTSTRUDL, structural design program, weight of steel structure is calculated. As a result of weight calculation, maximum 5.4% of weight reduction is achieved among examples of this study by applying LRFD comparing with the result of ASD, and those results quite dependent on the applied load and member classification.

  • PDF

A control of the parallel IGBT Converter for Auxiliary Block of High Speed Train

  • Geun-Woo Oh
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.543-547
    • /
    • 2000
  • Power factor and harmonics are increasingly important for high speed train auxiliary block. This paper presents experimental results of the power factor and harmonic performance of two parallel PWM circuits under various supply and load conditions. For reducing harmonics the harmonic content is eliminated by the phase shift between two converters switching phase. Experimental results show the usefulness of the proposed method and applicability to PWM converter in auxiliary block of high speed train.

  • PDF

고속전철 보조전원장치용 4병렬 IGBT PWM 컨버터에 관한 연구 (A Study on 4 Parallel IGBT PWM Converter for High Speed Train Auxiliary Block)

  • 김연충
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.274-277
    • /
    • 2000
  • Power factor and harmonics are increasingly important for high speed train auxiliary block. This paper presents experimental results of the power factor and harmonic performance of four parallel PWM converter circuits under various supply and load conditions. For reducing harmonics the harmonic content is eliminated by the phase shift between four converters switching phase. Experimental results show the usefulness of the proposed method and applicability to PWM converter in auxiliary block of high speed train.

  • PDF

POWER FACTOR CORRECTION OF CO2 WELDING MACHINE USING SINGLE-SWITCH THREE-PHASE AC/DC CONVERTER

  • Kim, Jse-Mun;Kim, Yuen-Chung;Ahn, Jung-Jun;Won, Chung-Yuen;Kim, Sei-Chan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.663-667
    • /
    • 1998
  • This paper describes for reducing harmonic distortion on CO2 welding machine with nonlinear load characteristic using single-switch three-phase AC/DC converter. The low-order harmonic component amplitude of the phase current of single-switch three-phase discontinuous mode is calculated. Experimental results show that CO2 welding machine with single-switch three-phase AC/DC converter is effectively controlled with power factor correction for phase current during welding time.

  • PDF

Novel Control Range Compensation Method in Power Factor Correction Circuit

  • Park, Youngbae;Cho, Donghye
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.224-225
    • /
    • 2012
  • When Power Factor Correction(PFC) boost converter is designed for the universal input range, unwanted burst operation can be found at high line and light load. This operation may cause an audible noise from the boost inductor or sensitive flicker for human eye can be found in case of the display application. In order to solve this difficulty, this paper proposes the new control range compensation method and shows the effectiveness than the conventional method thru the experimental result.

  • PDF

통신 네트워크 기반의 맥동 부하용 SPMS에 관한 연구 (Research on SPMS for Pulsating Load based on Communication Network)

  • 오진석
    • 한국정보통신학회논문지
    • /
    • 제18권4호
    • /
    • pp.927-933
    • /
    • 2014
  • CN(Communication Network)기반의 선박 전력관리 시스템은 선박의 안정적인 항해를 위한 가장 중요한 필수요소이다. 따라서 대부분의 선박은 안전을 목적으로 맥동 부하에 대응하기 위해 필요 용량보다 더 큰 용량의 발전기를 설치한다. 하지만 이러한 비교적 큰 용량의 발전기는 낮은 전력부하에서 발전기의 저부하 손실과 효율을 감소시키는 단점을 지니고 있다. 이에 따라 본 논문에서는 선박의 맥동부하를 방지하기 위한 보조전력을 적용한 하이브리드형 전력시스템을 제안하며, 전력시스템 설계를 위해 실 선박의 운항 데이터를 바탕으로 NI사의 LabVIEW를 이용하여 시뮬레이션을 진행하였다. 시뮬레이션을 통하여 안전항해를 위한 보조전력시스템과 연계한 하이브리드형 전력시스템의 적용방안을 제안한다.