• 제목/요약/키워드: Load Power Factor

검색결과 844건 처리시간 0.027초

A Sliding Mode Control Design based on the Reaching Law for Matrix Rectifiers

  • Wang, Zhiping;Mao, Yunshou;Hu, Zhanhu;Xie, Yunxiang
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1122-1130
    • /
    • 2016
  • This paper presents a novel approach for achieving both a tight DC voltage regulation and a power factor control by applying the Reaching Law Sliding Mode Control (RL-SMC) and the conventional Sliding Mode Control (SMC). Applying these strategies on a matrix rectifier (MR) can achieve a unity grid side power factor when the DC load changes widely and it can provide a ripple-free output voltage that is easily affected by distortions of the three-phase ac voltage supply. Furthermore, by employing the reaching law on the SMC can solve the chatting problem of the sliding motion. Comparative Matlab simulations and experimental verifications for these strategies have been presented and discussed in this paper. The results show that by applying the SMC and RL-SMC on a MR can achieve a unity grid side power factor and a regulated ripple-free DC output.

싸이리스터 컨버터부하에 적용되는 병렬형 능동필터의 적정용량산정 (Capacity Requirement Estimation of Shunt Active Power Filter for Thyristor Converter Load)

  • 박노중;정승기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권12호
    • /
    • pp.715-726
    • /
    • 1999
  • This paper estimates the capacity of shunt type active power filters(APF) for harmonic/reactive power compensation with a thyristor converter load. The base capacity requirement of APF is defined for idealized converter load current waveform and the effect of commutation overlap on the APF capacity is examined. The APF capacity required for reactive power compensation in addition to the harmonic elimination is estimated to give maximum achievable power factor for various operating condition of the partially-loaded thyristor converter. The method of current limit of APF is introduced, and it is shown that the APF capacity can be considerably reduced by deliberately limiting the peak current while maintaining the filtering performance to meet the level std 519 regulation.

  • PDF

굴착기의 부하율에 따른 실작업 질소산화물 배출 특성 연구 (Study on Real-Work NOx Emission Characteristics according to Load Factor of Excavator)

  • 신달호;박윤서;유철;박수한
    • 드라이브 ㆍ 컨트롤
    • /
    • 제20권3호
    • /
    • pp.1-8
    • /
    • 2023
  • The purpose of this study was to investigate and compare the impact of engine load on the emission characteristics of excavator engines, with the aim of improving the method for calculating the emission inventory of construction machinery. The engine load in excavators is directly correlated with the operational workload, and variations in the load factor (LF) can significantly influence the emission inventory. Thus, on-board diagnostic (OBD) data from an excavator at a construction site were systematically collected to measure engine output and emissions. The results revealed discernible differences in emissions based on engine load, even when the average excavator engine performance remained constant. This highlights the significant influence of the type and characteristics of the work being carried out on emission characteristics. Making realistic adjustments to the LF used in emission calculation formulas emerges as a crucial strategy for environmental improvement. Moreover, the analysis of the effects of engine load on emissions from excavators provides valuable insights for enhancing environmental protection measures.

캐리어의 핀홀 위치 오차에 따른 유성기어의 하중 분할 및 하중 분포 영향 분석 (Effect Analysis of Carrier Pinhole Position Error on the Load Sharing and Load Distribution of a Planet Gear)

  • 김정길;박영준;이근호;김영주;오주영;김재훈
    • 한국기계가공학회지
    • /
    • 제15권5호
    • /
    • pp.66-72
    • /
    • 2016
  • Gearboxes are mechanical components that transmit power by adjusting input and output speed and torque. Their design requirements include small size, light weight, and long lifespan. We have investigated the effects of carrier pinhole position error on the load sharing and load distribution characteristics of a planetary gear set with four planet gears. The simulation model for a simple planetary gear set was developed and verified by comparing analytical results with a putative model. Then, we derived the load sharing and load distribution characteristics under various pinhole position error conditions using the prototypical simulation model. The results showed that the mesh load factor and face load factor increased with the pinhole position error, which then influenced the safety factor for tooth bending strength and surface durability.

페라이틱 강 배관내의 원주방향 표면균열 평가를 위한 새로운 Z-Factor의 개발 (Development of New Z-Factor for the Evaluation of Circumferential Surface Crack In Ferristic Steel Pipings)

  • 최영환;정연기;이정배
    • 대한기계학회논문집A
    • /
    • 제20권6호
    • /
    • pp.1798-1809
    • /
    • 1996
  • The purpose of this paper is to develop new Z-Factors to evaluate the behavior of circumferential surface crack in ferritic steel piping including base metal and Submerged Arc Weld(SAW) metal in nuclear power plant. The Z-factor is a load multiplier to convert plastic load to elasto-plastic load. However the current Z-Factor is a load multiplier to convert plastic load to elasto-plastic load. However the current Z-Factor gives too conservative results. In this study, a J-estimation method, SC.TNP method, which is based on GE/EPRI expression, is used to develop new Z-Factors. The desirabilities of both the SC.TNP mehtod and the new Z-Factors are examined using the previous experimental results for the circumferential surface crack in ferritic steel pippings. The results are as follows ; (1) The SC.TNP mehtod is good for describing the circumferential surface crack behavior in farritic steel pipings, while the well-known R6 mehtod and DPFAD method give too conservative results. (2) The ASME-Z-Factor method using nwe Z-Factors well predicts the behavior of circumferential surface crack in ferritic steel pipings including base emtal and SAW metal.

공동주택에서의 전기자동차 충전기 수용률 설정과 그 제어방법 (Set up a Demand Factor of EV Chargers and Its Control Method in Apartments)

  • 김명수;홍순찬
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.98-105
    • /
    • 2014
  • In this paper, we have analyzed the power consumption property of EVs(Electric Vehicles) chargers established in a public place, proposed reasonable demand factors by the number of established EV chargers and its control method in apartments. The optimization of power system and the suppression of the peak load can be controlled through the proposed demand factors and charging scheduling control algorithm. In this paper, electrical design and an case analysis were carried out on a sample apartment complex to prove the effectiveness of the power system. As a result, emergency power transformer capacity has been reduced by approximately 25%, and we have confirmed that the electric rates saving and the control of peak load value is possible.

DVSC를 이용한 개선된 APF의 설계 (Design of Improved Active Power Filter using Discrete Variable Structure Control)

  • 박해원;김상우;한운동;김병진;전희종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1312-1314
    • /
    • 2000
  • In this paper, voltage control APF(Active Power Filter) is introduced to improve power factor and reduce harmonic, generated from nonlinear load. The voltage controlled APF which is consisted of inverter and passive filter operates with nonlinear load simultaneously. According to the results of simulation, it is proved that the proposed system has the performance of improving power factor and reducing harmonics.

  • PDF

선간전압과 상전압에 대한 전압불평형율의 비교 (Comparison of Voltage Unbalance Factor for Line and Phase Voltage)

  • 김종겸;박영진;이은웅
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권9호
    • /
    • pp.403-407
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, voltage unbalance is generated at the user's 3-phase 4-wire distribution systems with single & three phase. Voltage unbalance is mainly affected by load system rather than power system. Unbalanced voltage will draws a highly unbalanced current and results in the temperature rise and the low output characteristics at the machine. It is necessary to analyse correct voltage unbalance factor for reduction of side effects in the industrial sites. Voltage unbalance is usually defined by the maximum percent deviation of voltages from their average value, by the method of symmetric components or by the expression in a more user-friendly form which requires only the three line voltage readings. If the neutral point is moved by the unbalanced load at the 3-phase 4-wire system. Line and phase voltage unbalance leads to different results due to zero-sequence component. So that it is difficult to analyse voltage unbalance factor by the conventional analytical method, This paper presents a new analytical method for phase and line voltage unbalance factor in 4-wire systems. Two methods indicate exact results.

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Choi Y.K.;Ko T.G.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.987-993
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Furthermore, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristic.

  • PDF

전력계통의 부하주파수 제어를 위한 신경회로망 전 보상 PID 제어기 적용 (Application of Neural Network Precompensated PID Controller for Load Frequency Control of Power Systems)

  • 김상효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.480-487
    • /
    • 1999
  • In this paper we propose a neural network precompensated PID(NNP PID) controller for load frequency control of 2-area power system. While proportional integral derivative(PID) controllers are used in power system they have many problems because of high nonlinearities of the power system So a neural network-based precompensation scheme is adopted into a conventional PID controller to obtain a robust control to the nonlinearities. The applied neural network precompen-sator uses an error back-propagation learning algorithm having error and change of error as inputand considers the changing component of forward term of weighting factor for reducing of learning time. Simulation results show that the proposed control technique is superior to a conventional PID controller and an optimal controller in dynamic responses about load disturbances. The pro-posed technique can be easily implemented by adding a neural network precompensator to an existing PID controller.

  • PDF