• Title/Summary/Keyword: Load Flow Analysis

Search Result 876, Processing Time 0.029 seconds

Development of Educational Simulator for Power System Analysis (교육용 전력 시스템 해석 소프트웨어 개발)

  • Choo, Sung-Ho;Lee, Joo-Won;Lee, Woo-Nam;Kim, Hyun-Hong;Park, Jong-Bae;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.187-189
    • /
    • 2007
  • This paper presents the development method of educational simulator for Power System Analysis. The developed simulator can be made the students to model, analysis of power systems by drawing the system and performing the load flow, fault analysis by themselves under window environment. The simulator has developed by using the language based on XML(extensible Markup Language). Therefore, we determine that this simulator is useful to educate the load flow and fault analysis.

  • PDF

Power System Analysis Model for C.C Facility of Steel Plant (제철소 연주 전기설비 설계의 모델화)

  • Cho, Yang-Haeng;Son, Jae-Hyun;Park, Kyu-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.362-364
    • /
    • 2001
  • Every engineering discipline has, in recent year, felt the impact of computer-aided analysis and design Normally the studies of power system analysis by computer are load flow, short circuit and harmonic calculation, the amount the voltage deviates from motor starting, reliability and system stability. These studies are very important from the operating and planning points of power system. This paper presents analysis of load flow, short circuit current calculation, the effect for voltage deviation of induction motor starting and harmonic distortion in power system of continuous casting(C. C) plant. The resulting of analysis is applied the configuration and design engineering of power system.

  • PDF

Load Flow Analysis using Object-oriented Database (객체지향 데이터베이스를 이용한 전력조류계산)

  • Park, Ji-Ho;Baek, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.275-277
    • /
    • 2003
  • This paper deals with Object-oriented Database(OODB) which is designed for power system analysis, and describes load flow analysis using OODB. Database management systems are widely used and achieve high reliability of data management in the engineering fields. However conventional database systems, relational database system, have disadvantages in application to power system analysis. This paper presents advantages of OODB for modeling complex data of a power system analysis. The OODB supports data modeling requirements of GUI applications and the performance is well acceptable for GUI applications.

  • PDF

Development of the ELDC and Reliability Analysis of Composite Power System by Monte Carlo Method (Monte Carlo법에 의한 복합전력계통의 유효부하지속곡선 작성법 및 개발 및 신뢰도 해석)

  • Moon, Seung-Pil;Choi, Jae-Seok;Shin, Heung-Kyo;Lee, Sun-Young;Song, Kil-Yeong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.508-516
    • /
    • 1999
  • This paper presents a method for constructing composite power system effective load duration curves(CMELDC) at load points by Monte Carlo method. The concept of effective load duration curves(ELDC) in power system planning is useful and important in both HLII. CMELDC can be obtained from convolution integral processing of the probability function of unsupplied power and the load duration curve at each load point. This concept is analogy to the ELEC in HLI. And, the reliability indices (LOLP, EDNS) for composite power system are evaluated using CMELDC. Differences in reliability levels between HLI and HLII come from considering with the uncertainty associated with the outages of the transmission system. It is expected that the CMELDC can be applied usefully to areas such as reliability evaluation, probabilistic production cost simulation and analytical outage cost assessment, etc. in HLII, DC load flow and Monte Carlo method are used for this study. The characteristics and effectiveness of thes methodology are illustrated by a case study of the IEEE RTS.

  • PDF

Stress Analysis on a Structure of Solar Tracker Subjected to Wind Load (풍하중을 받는 태양광 추적 구조물의 응력해석)

  • Kim, Yong-Woo;Kim, Won-Bong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.747-754
    • /
    • 2012
  • A solar power generator is usually installed outdoors and it is exposed to extreme environments such as snow weight and wind loading. The solar tracker structure should be designed to have sufficient stiffness and strength against such loads. In this paper, simulations are performed by varying the parameters such as wind directions, wind speeds and the pose of the solar panel to evaluate the effects of extreme wind on solar tracker. As the effects of wind load, maximum displacement and maximum equivalent stress in the solar tracker are calculated. Finite element stress analysis is carried out by using the pressure distribution that is obtained by prior wind load analysis due to the flow around the solar tracker. The stress analysis of solar tracker to check and/or improve structural robustness provides some useful instructions for structural design or revision of solar tracker.

A Study on the Reinforcement of Reinforced Concrete using Evolutionary Structural Optimization (점진적 구조 최적화 기법을 응용한 철근콘크리트 부재의 배근)

  • 윤성수;이정재
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.2
    • /
    • pp.127-135
    • /
    • 2002
  • Due to the fact that the design of a reinforced concrete structure changes in accordance with its shape and assigned load, total automation of the design system has not been achieved. For instance, since there is no general rule about setting up reinforcing steel quantity and arrangement location, it is simply not feasible to automatically decide the reinforcing arrangement location. In this study, the ESO(evolutionary structural optimization) technique and its related issues will be discussed. The ESO techniques is determined the reasonable load path which is traveling of load between in-flow and out-flow at a concrete structure using numerical analysis. And the results applied to the steel arrangement in reinforced concrete structures. The optimal algorithm, which determines the terminal criteria during ESO process, has been updated by using the obtained results. And the load path within the member has been determined automatically.

Experimental Performance Analysis using a Compact Scale Model for Shroud Tidal Current Power Generation System (쉬라우드 조류발전장치의 축소모형실험을 통한 발전 성능 분석)

  • Han, Seok Jong;Lee, Uk Jae;Park, Da In;Lee, Sang Ho;Jeong, Shin Tark;Lee, Sang Seol
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.4
    • /
    • pp.221-228
    • /
    • 2019
  • Experimental investigation was performed to analyze the flow field characteristics and power generation performance for a shroud tidal power generation system. Electrical power output was compared with the rotational speed of the turbine blade and electric load connected to the generator for various flow velocity. As the electrical load decreased, the speed of the turbine increased rapidly and reached by about 2 times. The power output also increased remarkably with the decrease of load, and then decreased after maximum power point. In addition, the maximum power point appeared at high electrical loads as the experimental flow velocity increased. These results of the flow field characteristics and power generation performance analysis of the shroud tidal power generation system variation with the flow velocity conditions and electrical load are expected to be the basic data necessary for the development of efficient shroud tidal power generation system.

Stress Behaviors of Superheater Tubes under Load Change Operation in HRSG (배열회수보일러의 부하변동 운전에 따른 과열기 튜브들의 응력거동)

  • Chong, Chae-Hon;Song, Jung-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.33-39
    • /
    • 2008
  • The purpose of this study is not only to evaluate the stress behavior of tubes in superheater in HRSG during the load change operation but also to find root causes of failure from stress behavior. Firstly, temperature during operation was collected to perform stress analysis from actual HRSG. Part load and full load stress analysis which can be represented as the whole load change operations were performed using commercial finite element software. The possibility that can lead to tubes failure is found by stress analysis and its results is compared with metallurgical mircrostructure of failed tube which was taken from actual HRSG.

The development of frequency relaying algorithm considering a transient stability (과도 안정도를 고려한 주파수 계전 알고리즘 개발)

  • Lee, B.H.;Kim, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.282-283
    • /
    • 2006
  • A frequency relaying algorithm which is used system separation and load shedding to improve transient stability is proposed. The algorithm can trip the generator and shed load in the abnormal frequency condition. The computer simulations of load flow analysis is used to determine the amount of load to be shed in an under frequency condition. Furthermore dynamic brake energization in the simulation is performed for the control of overfrequency.

  • PDF

A Load Modeling to Utilize Power System Analysis Software (전력계통해석용 프로그램에 적용하기 위한 부하모델링)

  • 지평식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.96-101
    • /
    • 1999
  • Load model is very important to improve accuracy of stability analysis and load flow study in power systems. A power system bus is composed by various loads, and loads have different power consumption due to voltage/frequency changing. Thus the effect of voltage/frequency changing must he considered to load mxleling. In this research, ANN was used to construct component load moddel for more accurate load mxleling. Typical residential load was selected, and characteristics exrerimented on voltage/frequency changing. Acquired data used to construct the component ANN model, and aggregation method of component load model was presented based on component load model and composition rate. Furthennore, it's transfomlation method to the mathematical load model to he used at the traditional power system analysis soft wares was also presented.sented.

  • PDF