• 제목/요약/키워드: Livestock Wastewater Treatment

검색결과 153건 처리시간 0.026초

우리나라 하수처리장 방류수 수질현황 및 특성 (Survey of the Secondary Effluents from Municipal Wastewater Treatment Plants in Korea)

  • 김영철;안익성;강민기
    • 한국물환경학회지
    • /
    • 제21권2호
    • /
    • pp.158-168
    • /
    • 2005
  • In this study, the discharging effluents from have been 9 municipal wastewater treatment plants surveyed for 1 year-period. Statistics including probability distribution, cumulative occurrence concentration and other statistical parameters were presented. In addition, treatment performance and its stability were also discussed. Most of the plants, have an operational problem of high soluble organic content in the secondary effluent which may be associated with the integrated treatment of human and livestock manures. Nitrogen concentration in the effluents were usually higher during the period of summer and winter. It was found that this is mainly due to lack of the proper C/N ratio during the summer, or/and the effects of low temperature and less dilution by dry weather during the winter. Phosphorus concentration is sharply increased in June. Discussion with plant operators told that it is due to the dissolution of phosphate from the sludge accumulated in the primary settling tanks from the early spring to june. During this period, usually, sludge treatment line is highly overloaded with flush-outs of the sediments also stored in the bottom of combined sewer due to the low flow during winter season. Most of the plants can meet new effluent discharge limits of the nitrogen and phosphorus, and total coliform without further treatment.

황토를 이용한 축산폐수의 처리에 관한 연구 (Treatment of Livestock Wastewater with Coagulant-loess)

  • 박진희;김보국;원찬희
    • 대한환경공학회지
    • /
    • 제22권10호
    • /
    • pp.1799-1808
    • /
    • 2000
  • 본 연구에서는 구입이 용이한 황토를 이용하여 축산폐수외 화학적 응집 처리제로서의 적용가능성과 최적 응집조건을 찾고 기존에 사용되어 왔던 고분자 응집제(PAC, PACS, LAS)와 응집성능을 비교하였다. 연구 결과 황토와 생석회의 최적 혼합비율은 3:7이었으며, 이 혼합 응집제의 적정 주입량은 30 g/L이었다. 기존 응집제와 비교실험에서는 loess : lime = 3 : 7의 경우 탁도, SS, BOD, $COD_{er}$, T-P, TKN의 제거효율이 각각 95.8%, 92.5%, 71.6%, 71.1%, 98.2%. 32.5%를 나타내었다. Loess : lime = 3 : 7은 응집제로서 사용할 수 있으며, 생산된 슬러지는 토양개량제로서의 사용 가능성을 확인할 수 있었다.

  • PDF

다양한 하수를 대상으로 아질산화 반응 적용성 평가 (Applicability Evaluation of Nitritation with Various Wastewater)

  • 임지열;길경익
    • 한국습지학회지
    • /
    • 제17권1호
    • /
    • pp.11-18
    • /
    • 2015
  • 질소에 의한 수질 오염의 심각성이 부각되면서 하 폐수 내 질소제거를 위한 연구가 수행되고 있다. 특히 아질산화 반응을 기반으로 하는 경제적이며 친환경적인 장점을 지닌 혁신적인 질소 제거 공법에 관한 연구가 주목받고 있다. 하지만 아질산화 반응을 기반으로 하는 공법의 현장 적용성 및 효율화 방안에 관한 연구는 완전히 이루어지고 있지 않은 실정이다. 본 연구에서는 하수처리장 유입 하수, 최초 침전지 상등액, 반류수 그리고 가축분뇨의 특성분석 및 실험실 규모 반응조를 운전하였다. 반류수 및 가축분뇨의 경우 다른 하수에 비해 고농도의 질소를 함유한 것으로 나타나 수처리 계통 질소 부하를 증가시키는 것으로 나타났다. 반응조 운전 결과 낮은 암모니아성 질소의 농도로 인해 유입 하수와 최초 침전지 상등액의 경우에는 아질산화 반응이 유도되지 않음을 확인하였다. 또한 하수 종류 별로 아질산화 반응이 유도되는 체류시간 조건이 차이를 보였는데 이는 유기물 및 암모니아성 질소 농도에 의한 것으로 판단된다. 아질산화 반응이 유도된 하수 중 혐기 소화 상등액이 가장 높은 효율을 보이는 것으로 나타났다.

인공습지를 이용한 축산폐수처리장에서 수생식물의 생육특성과 영양염류 흡수특성 (Growth Characteristic and Nutrient Uptake of Water Plants in Constructed Wetlands for Treating Livestock Wastewater)

  • 박종환;서동철;김성헌;이충헌;최정호;이상원;이동진;하영래;조주식;허종수
    • 한국환경농학회지
    • /
    • 제31권4호
    • /
    • pp.351-358
    • /
    • 2012
  • 수생식물은 인공습지 오 폐수처리장에서 여재의 입단 형성을 촉진시켜 폐수의 투수속도를 증가시킬 뿐만 아니라 악취를 줄이고 미관상 혐오감을 크게 줄일 수 있으며, 수처리효율과 밀접한 관련이 있다고 보고하였다. 이에 본 연구는 수생식물여과조-활성슬러지-인공습지를 하나의 시스템으로 시공한 축산폐수처리장에서 수생식물의 생육특성 및 영양염류의 흡수특성을 조사하기 위해 3차 수직 흐름조에는 갈대, 4차 수평 흐름조에는 노랑꽃창포 및 5차 수평 흐름조에는 갈대, 노랑꽃창포 및 부들을 2010년 7월에 이식하였으며, 축산폐수 처리시일을 1, 3 및 5개월로 구분하여 각 수생식물의 생육특성과 영양염류 흡수특성 조사하였다. 수생식물의 생육특성은 갈대, 노랑꽃창포 및 부들 모두 처리시일 3개월인 10월까지는 수생식물의 성장과 동시에 수생식물이 무성하게 퍼졌으며, 특히 노랑꽃창포의 경우 타 수생식물에 비해 생육이 매우 좋았다. 수생식물의 생육 5개월 후인 2010년 12월의 경우는 겨울철 식물의 고사로 인하여 수생식물의 생육이 저조하였다. 수생식물의 영양염류 흡수특성은 수생식물 이식 후 1개월까지 점점 증가하였으나 증가폭이 크지 않았고, 수생식물 이식후 3개월 후인 가을철에는 수생식물의 질소 흡수량이 최대가 되었다. 그러나 수생식물 이식 후 5개월 후인 겨울철에는 수생식물의 고사로 인해 수생식물의 잎과 줄기가 고사하여 영양염류의 흡수량이 다시 감소하였다. 또한 수생식물 종별 영양영류의 흡수특성은 노랑꽃창포 ${\gg}$ 부들 > 갈대 순이었고, 특히 노랑꽃창포가 다른 수생식물에 비해 영양염류의 흡수량이 매우 높았다.

공공하수처리시설 방류수 TOC에 영향을 주는 요인 분석 (Analysis of factors affecting effluent TOC in publicly owned treatment works)

  • 강성주;강병준;박규홍;정동환;이원석;정현미
    • 상하수도학회지
    • /
    • 제33권2호
    • /
    • pp.141-150
    • /
    • 2019
  • Total organic carbon(TOC) was introduced as the water quality index of the rivers and lakes in 2013. This paper evaluated factors affecting effluent TOC concentrations and treated and discharged loads of existing publicly owned treatment works(POTWs). For selected POTWs with greater treatment capacity than $500m^3/day$, factorial analysis was used to consider effects of kinds of biological treatment processes, inflow of other types of wastewater(industrial, livestock, landfill leachate wastewater, etc.) with domestic wastewater, sewer separation rate, and effluent discharging zones in which different effluent criteria applied. As a result, those factors did not show significant effect on effluent TOC concentration of POTWs in effluent discharging zone I and II. However, In effluent discharging zone III and IV, kinds of biological treatment processes, the inclusion of other waste in influent of domestic wastewater, and the sewer separation rate were significant factors. The treated TOC load in POTWs was also not affected significantly by the variables set in this study. On the other hand, those three factors influenced significantly on the TOC load discharged to water bodies. The sum of factorial effects and the contribution rate of three factors to the discharged TOC load was 60.23 and 41%, 59.57 and 41%, and 42.04 and 18%, respectively.

음식물류폐수처리를 위한 유기물분해 미생물의 분리 및 동정 (Isolation and Identification of Organic Compounds-Degrading Bacteria for the Treatment of Food Wastewater)

  • 정두영;송인근;김영준
    • 유기물자원화
    • /
    • 제15권2호
    • /
    • pp.128-135
    • /
    • 2007
  • 음식물폐수, 축산폐수, 지렁이 등, 다양한 분리원으로부터 음식물류폐수내 섬유소, 지방, 단백질 등 유기 성분을 처리하기 위한 유기물분해 미생물을 분리하여 그 특징을 밝히고 균주를 동정하였다. 음식물류폐수에서 분리된 6종의 균주를 비롯하여 음식물폐수내 삼성 유기물에 대한 분해능이 우수한 11균주를 최종적으로 분리하여 동정하였다. 분자생물학적 동정결과, 9종은 Bacillus 속으로 밝혀졌고, 2종은 Enterobacter 속 및 Pantoea agglomerans로 동정되었다. 유기물분해효소 활성도 조사결과, 음식물폐수로부터 분리된 FWB-5 (Bacillus pumilus)와 FWB-6 (B. lichenisformis) 및 축산폐수로부터 분리된 OD-4 (Pantoea agglomerans)의 균주에서 섬유소에 대한 효소활성이 가장 높게 나타난 것을 비롯하여 전체적으로 효소활성도가 높게 나타났다. FWB-5 및 OD-4의 경우, 효소활성을 위한 최적 생장온도 및 pH는 각각 $37^{\circ}C$ 및 7.0으로 나타났으며, FWB-6의 경우, $25^{\circ}C$에서 단백질 및 지질에 대한 효소활성도가 높게 관찰되었다.

  • PDF

축산폐수의 효율적 처리기술 개발 (Development of Effective Treatment Technology of Livestock wastewater)

  • 조웅현;원찬희;송경선
    • 한국해안해양공학회:학술대회논문집
    • /
    • 한국해안해양공학회 2000년도 한국해안해양공학발표논문집 Proceedings of Coastal and Ocean Engineering in Korea
    • /
    • pp.77-83
    • /
    • 2000
  • 가축 사육시설에서 배출되는 축산폐수는 도시하수와 달리 발생량에 비해 오염부하량이 대단히 크므로 수질오염의 주범일 뿐만 아니라 처리에도 어려움이 많아 축산폐수를 수거하여 전문적으로 처리하는 공동처리장에서도 현재 만족 할만한 처리효과를 기대하기 힘든 처지에 있다. (중략)

  • PDF

열처리 및 오존산화처리를 이용한 축산폐수처리장 폐활성오니의 재활용 (Reuse of Waste Activated Sludge from Livestock Wastewater Treatment Process using Thermal and Ozone Oxidation Treatment Method)

  • 김영기;남세용;김경섭
    • 공업화학
    • /
    • 제17권1호
    • /
    • pp.22-27
    • /
    • 2006
  • 축산폐수처리과정에서 발생하는 부산물인 폐활성오니를 농업용으로 재활용하기 위하여 유효성분을 분석하고, 재활용을 위한 처리기법으로 열처리와 오존산화처리에 대한 실험을 수행하였다. 폐활성오니의 성상분석 결과로부터 고형분의 질량백분율로 탄소 44.25%, 질소 8.43%, 인 1.35%로 농업용 비료로서의 가치를 확인하였다. 잠재 병원성균의 정량분석결과로부터 적절한 처리방법에 의한 병원성균 비활성화의 필요성을 확인하였다. 열처리방법의 TSS, COD, SCOD, 병원성균 처리효율을 분석하여 최적 운전조건으로 $70^{\circ}C$, 10 min으로 결정하였다. 오존산화 처리후의 TSS, COD, SCOD, 병원성균 처리효율을 분석한 결과 최적 운전조건으로 $0.6L\;O_3/L\;solution{\cdot}min$, 60 min을 결정하였다. 최적 운전조건의 열처리방법과 오존산화방법의 처리효율 비교분석으로 열처리방법의 우수한 병원성균 비활성화 효과와 오존산화방법의 상대적으로 우수한 고형분 감량 및 유기물 용해효과를 검증하였다. 하지만 두 방법이 가지는 단점으로 인하여 폐활성오니 재활용을 위한 효과적 처리를 위해서는 다른 처리방법과의 조합이 바람직하다.

고온호기발효공법을 이용한 유기성폐수의 처리 (The Treatment of Organic Wastewater using Thermophilic Oxic Process)

  • 유순주;류재근;서윤수;도삼유평
    • 환경위생공학
    • /
    • 제10권2호
    • /
    • pp.13-22
    • /
    • 1995
  • Most of small- scale livestock facility have difficulties to treat organic wastewater by activated sludge process as distinguished feces and urine. The organic wastewater discharged have characteristics of slurry, high concentration of BOD, 55 etc. This study was performed to estimate suitable condition for the application of packing materials, air flow, pollutant load and so on as important parameter to treat organic wastewater by thermopile oxlc process. As a result obtained at this experiments the most suitable condition for BOD load, air flow indicate 3.0kg · m$^{-3}$ day$^{-1}$,50 ∼ 100L· min$^{-1}$ m$^{-3}$, respectively, and we knew that it was necessary to add waste contained high calories to degrade about 80% of pollutant among waste- water. It showed that plastic material can be used as packing media because it can be provided as inhabitation for microorganism owing to intensity of material and characteristic of keeping moisture.

  • PDF

전기화확적 방법에 의한 축산폐수의 처리 (Treatment of Livestock Wastewater by Electrochemical Method)

  • 허종수;정태욱;이홍재;백송범;조주식
    • 한국환경농학회지
    • /
    • 제18권4호
    • /
    • pp.332-338
    • /
    • 1999
  • 전기화학적 방법에 의한 축산폐수의 효과적인 처리를 위하여 스테인레스 전극판 및 알루미늄 전극판을 이용한 회분석 실험에서는 전압, 전극판 간격 및 전해용액 주입농도별 오염물질의 처리효율을 조사한 결과는 다음과 같다. 전압별 전기화학반응 실험 결과 두가지 전극재질 모두 전압이 높을수록 전기화학반응조 내의 온도 및 pH는 상승하였으나, EC는 감소하는 경향이었다. COD 및 T-N처리율은 두가지 전극재질 모두 전압이 높을수록 전반적으로 증가하였고, SS처리율은 두가지 전극재질 모두에서 전압의 세기에 관계없이 반응초기에 약 90% 이상이었으나 20V에서는 15분 그리고 30V에서는 12분 이상 전기화학반응을 시켰을 경우에는 그 처리율이 80% 이하로 감소되었다. T-P처리율은 두가지 전극재질 모두에서 전압의 세기에 관계없이 약 90% 이상이었다. 전극판 간격별 전기반응 실험 결과 COD, T-N 및 T-P처리율은 두가지 전극재질 모두 전극판 간격이 좁을수록 대체적으로 증가하였으며, SS처리율은 두가지 전극재질 모두 전극판 간격에 관계없이 반응초기에 약 90% 이상이었다. 전해용액인 PACS의 주입농도별 전기반응 실험 결과 COD, T-N 및 T-P 처리율은 PACS의 주입농도가 증가할수록 대체적으로 증가하였으나 PACS의 주입농도가 200㎎/l 이상에서는 오염물질의 처리효율이 별 차이가 없었고, SS처리율은 두가지 전극재질 모두 약 90% 이상이었다. 이상의 회분식 실험결과 전기화학적 방법에 의한 축산폐수의 최적 처리 조건은 전압 20V, 전극판 간격 1㎝ 그리고 PACS 주입농도 200㎎/l 인 것으로 판단되었다.

  • PDF