• 제목/요약/키워드: Lithium disilicate glass-ceramic

검색결과 37건 처리시간 0.02초

열가압 방식의 금속-유리도재 이중 구조물의 전단결합강도에 대한 연구 (Shear bond strength in bilayer metal-heat pressed glass ceramic structure)

  • 이경은;박진영;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제39권2호
    • /
    • pp.101-107
    • /
    • 2017
  • Purpose: The purpose of this study was to compare the shear bond strength of the metal-heat pressed glass ceramic bilayer structure. Methods: Metal framework specimens were prepared and surface is spreaded opaque(IPS InLine system opaque, IvoclarVivadent, Liechtenstein). There were 10 specimens for each bilayer dental ceramic group. The first group was porcelain fused metal, Press on metal IPS Inline press group, and press on metal HASS prototype group. Specimens measured for the shear bond strength on Schwickerath test by Instron universal testing machine(Instron3345, Instron Corp., USA). Mean average bond strength values of each specimen group were analyzed using a one-way ANOVA analysis of variance Saphiro-wilk's test. Statistical analysis were performed using IBM SPSS 23.0(IBM Co., Armonk, USA) Results: $RMS{\pm}SD$ The highest mean average HASS POM showed a bond strength value ($47.55{\pm}12.80Mpa$). The lowest mean average values Porcelain fused metal ($33.30{\pm}2.00Mpa$). Independent t-test was conduct to analysis the significant difference (p<0.05) (Table 3). Conclusion: Three kinds of Metal/ glass bilayer dental ceramics bond strength were clinical acceptability. Especially, as lithium disilicate containing represents higher bond strength.

FRACTURE STRENGTH AND MARGINAL FIT OF IN-CERAM, COPY-MILLED IN-CERAM, AND IPS EMPRESS 2 ALL-CERAMIC BRIDGES

  • Hwang Jung-Won;Yang Jae-Ho;Lee Sun-Hyung
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.641-658
    • /
    • 2001
  • All-ceramic restorations have become an attractive alternative to porcelain-fused-to-metal crowns. In-Ceram, and more recently IPS Empress 2 were introduced as a new all-ceramic system for single crowns and 3-unit fixed partial dentures. But their strength and marginal fit are still an important issue. This study evaluated the fracture resistance and marginal fit of three systems of 3 unit all-ceramic bridge fabricated on prepared maxillary anterior resin teeth in vitro. The 3 all-ceramic bridge systems were: (1) a glass-infiltrated, sintered alumina system (In-Ceram) fabricated conventionally, (2) the same system with copy-milled alumina cores (copy-milled In-Ceram), (3) a heat pressed, lithium disilicate reinforced glass-ceramic system (IPS Empress 2). Ten bridges of each system with standardized design of framework were fabricated. All specimens of each system were compressed at $55^{\circ}$ at the palatal surface of pontic until catastrophic fracture occurred. Another seven bridges of each system were fabricated with standard method. All of the bridge-die complexes were embedded in epoxy resin and sectioned buccolingually and mesiodistally. The absolute marginal discrepancy was measured with stereomicroscope at ${\times}50$ power. The following results were obtained: 1. There was no significant difference in the fracture strength among the 3 systems studied. 2. The Weibull modulus of copy-milled In-Ceram was higher than that of In-Ceram and IPS Empress 2 bridges. 3. Copy-milled In-Ceram($112{\mu}m$) exhibited significantly greater marginal discrepancy than In Ceram ($97{\mu}m$), and IPS Empress 2 ($94{\mu}m$) at P=0.05. 4. The lingual surfaces of the ceramic crowns showed smaller marginal discrepancies than mesial and distal points. There was no significant difference between teeth (incisor, canine) at P=0.05. 5. All-ceramic bridges of three systems appeared to exhibit sufficient initial strength and accept able marginal fit values to allow clinical application.

  • PDF

How adjustment could affect internal and marginal adaptation of CAD/CAM crowns made with different materials

  • Hasanzade, Mahya;Moharrami, Mohammad;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권6호
    • /
    • pp.344-350
    • /
    • 2020
  • PURPOSE. Recently introduced hybrid and reinforced glass ceramic computer-aided design/computer-aided manufacturing (CAD/CAM) materials have been used for full-coverage restorations. However; the effect of adjustment and type of materials on internal and marginal adaptation are unknown. This study aimed to evaluate and compare the marginal and internal adaptations of crowns made of three different CAD/CAM materials before and after adjustment. MATERIALS AND METHODS. One acrylic resin maxillary first molar was prepared and served as the master die. Thirty-six restorations were fabricated using CAD/CAM system (CEREC Omnicam, MCXL) with three materials including lithium disilicate (IPS e.max CAD), zirconia-reinforced lithium silicate (Suprinity), and hybrid ceramic (Enamic). Internal and marginal adaptations were evaluated with the reference point matching technique before and after adjustment. The data were analyzed using mixed ANOVA considering α=.05 as the significance level. RESULTS. The effect of adjustment and its interaction with the restoration material were significant for marginal, absolute marginal, and occlusal discrepancies (P<.05). Before adjustment, Suprinity had lower marginal discrepancies than IPS e.max CAD (P=.18) and Enamic (P=.021); though no significant differences existed after adjustment. CONCLUSION. Within the limitations of this study, crowns fabricated from IPS e.max CAD and Suprinity resulted in slightly better adaptation compared with Enamic crowns before adjustment. However, marginal, axial, and occlusal discrepancies were similar among all materials after the adjustment.

심미보철 치료의 경향과 이해 : part 1. IPS e.max (Understanding and trends of esthetic treatment in prosthodontics : IPS e.max)

  • 강정인;허유리;이명선;손미경
    • 한국치위생학회지
    • /
    • 제14권4호
    • /
    • pp.447-452
    • /
    • 2014
  • With the increase of esthetic demands, most patients want to have restorations which are not only functional but also esthetic. For the esthetic restoration, many ceramic systems have been introduced and applied in dentistry. Among those ceramic restorations, IPS e.max system composed of lithium disilicate glass ceramic is one of the most commonly used systems because it has strength and esthetic characteristics. IPS e.max system is divided into IPS e.max Press and IPS e.max CAD according to the manufacturing methods. IPS e.max Press is fabricated through heat-pressed technique with ceramic ingot, which is very simple. The restorations which are made using IPS e.max system can apply to 3 units restoration for the anterior teeth and premolar, and single posterior tooth restoration. Cementation is one of the most important clinic procedure for the longevity of the restorations. All ceramics are bonded by resin cements, it is classified into three groups including adhesive, self-adhesive, and conventional. Variolink N, which is an adhesive resin cement and manufactured by same company with IPS e.max, is recommended for the bonding of IPS e.max restoration. Conventional and self-adhesive resin cement is also available. The aim of this review article is to provide the understanding of material properties, production procedure and clinical application of IPS e.max system.

도재층의 두께와 색이 도재수복물의 최종 색조에 미치는 영향 (THE INFLUENCE OF PORCELAIN LAYER THICKNESS AND COLOR ON THE FINAL SHADE OF CERAMIC RESTORATIONS)

  • 성동환;이임기;송진원;복원미;안승근;박찬운
    • 대한치과보철학회지
    • /
    • 제43권5호
    • /
    • pp.587-598
    • /
    • 2005
  • Statement of problem: Ceramic restorations should be made of porcelain layers of different opacity, shade, and thickness in order to provide a natural appearance. Lithium disilicate glass-ceramic system has superior color reproducibility, because it uses the ceramic ingot which is similar to teeth shade and uses the staining technique and layering technique. However, staining technique has a fault of discoloration. Also, porcelain is divided core and dentin layer, it is not enough to study about the influence of porcelain layer thickness and shade on the shade of ceramic restorations. Purpose: The purpose of this study was to evaluate the influence of porcelain layer thickness and color on the final shade of ceramic restorations. Materials and method: The CIE $L^*a^*b^*$(CIELAB) values of 72 assembled specimens, each consisting of 3 discs (enamel porcelain 0.2 mm/dentin porcelain -1.2, 0.9, 0.7, 0.5 or 0.3 mm/ceramic core -0.3, 0.5, 0.7, 0.9 or 1.2 mm, diameter is 1.0 mm) were evaluated with a spectrophotometer (Model Chromaview 300, Spectron Tech Co, Korea) for the shade A1, A2, A3 and A4. Distilled water (refractive index: 1.7) was used to attain optical contact between the layers. White, white gray, and white brown backgrounds were used to assess the influence of the background on the final shade. And the mean color difference value$({\Delta}E)$ was calculated. Results and conclusion: The results obtained from this study were as follows. 1. There was a significant correlation between the thickness ratio of the ceramic core/dentin porcelain system and $L^*,\;a^*\;and\;b^*$ values when the total thickness of specimen combination was smaller than 1.4 mm(P<0.05). 2. The specimen which the ceramic core thickness was more than 0.7 mm had the best masking effect against background colors. 3. The mean color difference value$({\Delta}E)$ is smaller than 2 $({\Delta}E<2)$ when the ceramic core thickness was larger than 0.7 mm and the total thickness of specimen was more than 1.4 mm.

심미수복을 위한 글라스-세라믹 재료의 치과 응용 (Dental application of glass-ceramic materials for aesthetic restoration)

  • 배태성
    • 대한치과의사협회지
    • /
    • 제58권7호
    • /
    • pp.435-442
    • /
    • 2020
  • 치과의사가 수복재료를 선택하고 환자에게 추천할 때는 수복할 치아 위치, 결손 정도, 환자의 심미적 요구도, 저작력, 나이, 경제적 여건 등 여러 가지의 요인을 고려한다. 그렇지만, 수복재료를 선택할 때의 일차적인 기준은 구강 내에서 기능 시 작용하는 교합력을 최우선으로 고려해야 한다. 미국 국립보건원(NIH) 지원으로 조사된 연구 결과에 의하면, 전치부 수복재료로서는 리튬 디실리케이트계 글라스-세라믹이 54%, layered zirconia가 17%, 루사이트 강화 글라스-세라믹이 13% 순을 보여, 전치부 수복재료로서 리튬 디실리케이트계 글라스-세라믹이 가장 많이 사용었다. 또한 구치부 수복재료로서는 단일구조 지르코니아가 32%, 금속-세라믹이 31%, 리튬 디실리케이트계 글라스-세라믹이 21% 순을 나타냈다. 세라믹 수복 재료의 특성을 살펴보면, 단일구조 지르코니아는 강도는 높지만 명도가 높고 저온열화로 인한 강도 저하가 일어날 수 있다. layered zirconia는 심미성은 우수하지만 강도가 낮은 비니어 세라믹의 칩핑과 박리가 문제가 되고 있다. 리튬 디실리케이트계 글라스-세라믹은 심미성은 우수하지만 지르코니아에 비해 강도가 낮으므로 구치부에 적용 시 파절이 일어날 위험성이 있다. 루사이트계 글라스-세라믹은 심미성은 우수하지만 기본적으로 강도가 낮기 때문에 전치부에 한정하여 적용한다. 세라믹 크라운이 구치부 교합력에 저항하기 위해서는 350 MPa 이상의 굴곡강도를 가져야 한다. 리튬 디실리케이트계 글라스-세라믹은 광투과성이 양호한 심미성이 있는 재료이므로 비니어 없이 전치부에 적용할 수 있고, 굴곡강도가 400 MPa 이상이므로 구치부 교합력에 저항할 수 있고, HF에 의한 산부식과 실란(silane) 처리가 가능하므로 레진과 강한 결합력을 얻을 수 있고, 또한 포세린에 비해 대합치의 마모가 적다. 이러한 점들을 고려하면 리튬 디실리케이트계 글라스-세라믹 재료는 전구치부의 단일치 수복에 적합한 성질을 갖고 있음을 알수 있다. 그렇지만 그의 임상 응용이 더욱 증가하기 위해서는 이들 재료에 대한 보다 많은 연구와 이해가 필요하리라고 생각된다.

  • PDF

Empress 2 도재의 두께에 따른 파절강도에 관한 연구 (INFLUENCE OF THICKNESS OF EMPRESS 2 CERAMIC ON FRACTURE STRENGTH)

  • 고정우;양재호;이선형
    • 대한치과보철학회지
    • /
    • 제38권4호
    • /
    • pp.446-460
    • /
    • 2000
  • All-ceramic restorations have had a more limited life expectancy than metal ceramic crowns be-cause of their lower strength. The relatively lower strength has limited the use of all-ceramic crowns to the areas where occlusal loads are lower Therefore many researches have been done to increase the strength of all-ceramic crowns. IPS Empress 2 is a new type of lithium disilicate glass-ceramic with enhanced physical characteristics which has been in use clinically since 1998. Previous researches reported that the flexural strength of all-ceramic material was greater than 300 MPa, and all-ceramic crowns can be used in staining or layering technique. The objective of this study was to investigate the influence of the thickness of IPS Empress 2 ceramic on fracture strength. Both staining technique and layering technique was investigated. Vita VMK was used as control. For all three groups, five specimens each of 0.8mm, 1.0mm, 1.4mm, 1.8mm, and 2.2mm thick-ness (a total of 75 specimens) were prepared. Control group : Vita VMK Porcelain specimens were prepared with dentine ceramic and liquid glazing was done. Group I : IPS Empress 2 were prepared with staining technique and stained twice and glazed once. Group II : IPS Empress 2 were prepared with layering technique and glazed after wash firing. The thickness and diameter of the specimen were measured and controlled after specimen preparation. Biaxial Flexure Test (ASTM Standard F394-78) was adopted as this test method produces results least affected by the edge condition of the specimens. Fracture strength was measured with Instron Universal Testing Machine. Conclusions are as follow : 1. The fracture strength was increase in order of control group, test group I, test group II. 2. Fracture strength of the group I (Empress 2 Staining) was 65.54 N in 0.8mm, 155.2 N in 1.0mm, 233.5 N in 1.4mm, 434.5 N in 1.8mm, and 600.1 N in 2.2mm. 3. Fracture strength of the group II (Empress 2 Layering) was 190.0 N in 0.8mm, 283.5 N in 1.0mm. 437.2 N in 1.4mm, 732.0 N in 1.8mm, and 1115.0 N in 2.2mm. 4. No statistical difference was found in flexural strengths according to thickness in a specified group(p>0.05).

  • PDF