• Title/Summary/Keyword: Liquid-liquid extraction (LLE)

Search Result 66, Processing Time 0.029 seconds

Comparison of Preparation Methods for the Quantification of Ginsenosides in Raw Korean Ginseng

  • Hong, Hee-Do;Sim, Eun-Mi;Kim, Kyung-Tack;Rho, Jeong-Hae;Rhee, Young-Kyung;Cho, Chang-Won
    • Food Science and Biotechnology
    • /
    • v.18 no.2
    • /
    • pp.565-569
    • /
    • 2009
  • This study was conducted to evaluate the effects of different preparation methods on the recovery and quantification of ginsenosides in raw Korean ginseng (Panax ginseng C.A. Meyer). Eight major ginsenosides ($Rb_1$, $Rb_2$, $Rb_3$, Rc, Rd, Re, Rf, and $Rg_1$) were analyzed by high performance liquid chromatography (HPLC), after which the recovery and repeatability of the extraction of those ginsenosides using 3 different preparation methods were compared [A. direct extraction (DE) method, hot MeOH extraction/evaporation/direct dissolution; B. solid phase extraction (SPE) method, hot MeOH extraction/evaporation/dissolution/$C_{18}$ cartridge adsorption/MeOH elution; C. liquid-liquid extraction (LLE) method, hot MeOH extraction/evaporation/dissolution/n-BuOH fractionation]. Use of the DE method resulted in a significantly higher recovery of total ginsenosides than other methods and a relatively clear peak resolution. Use of the SPE and LLE methods resulted in clearer peak resolution, but lower ginsenoside recovery than the DE method. The LLE method showed the lowest ginsenoside recovery and repeatability among the 3 methods. Given that the DE method employed only extraction, evaporation, and a dissolution step (avoiding complicate and time consuming purification), this technique may be an effective method for the preparation and quantification of ginsenosides from raw Korean ginseng.

A Solid-Phase Extraction Method for Analyzing Trace Amounts of Polychlorinated Dibenzo-p-Dioxins and Dibenzofurans in Waste Water

  • Park, Deok-Hie;Youn, Yeu-Young;Choi, Jae-Won;Lim, Young-Hee;Cho, Hye-Sung
    • Mass Spectrometry Letters
    • /
    • v.2 no.1
    • /
    • pp.12-15
    • /
    • 2011
  • The Korean government has regulated emission of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in waste water of manufacturing facilities producing chlorinated compounds since 2009. As this regulation is expected to be reinforced in 2013 to 50 pg I-TEQ/L, a large sample volume is required for the analysis of trace amounts of PCDD/Fs in waste water. Liquid-liquid extraction (LLE) is used to extract PCDD/Fs from aqueous samples; however, its low efficiency makes it inadequate for analyzing large sample volumes. Herein, we present a disk-type solid-phase extraction (SPE) method for the analysis of dioxin at a part per quadrillion level in waste water. This SPE system contains airtight glass covers with a decompression pump, which enables continuous semi-automated extraction. Small (0.5 L) and large (7 L) samples were extracted using LLE and SPE methods, respectively. The method detection limits (MDLs) were 0.001.0.25 and 0.015.4.1 pg I-TEQ/L for the SPE and LLE methods, respectively. The concentrations of detected congeners with both methods were similar. However, the concentrations of several congeners that were not detected with the LLE method were quantified using the SPE method.

Establishment of Analytical Method for Pymetrozine Residues in Crops Using Liquid-Liquid Extraction(LLE) (액-액 분배법을 활용한 작물 중 pymetrozine의 잔류분석법 확립)

  • Yoon, Ji-Young;Moon, Hye-Ree;Park, Jae-Hun;Han, Ye-Hoon;Lee, Kyu-Seung
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.2
    • /
    • pp.107-116
    • /
    • 2013
  • Polar pesticides like pymetrozine (log $P_{ow}$: -0.18) are known to be difficult to analyze. The analytical method of pymetrozine using hydromatrix included in the official method of KFDA was uncommon and provided ambiguous evidence to confirm both the identity and the quantity. Therefore, precise single residue analytical method was developed in representative crops for using liquid-liquid extraction (LLE). The pymetrozine residue was extracted with methanol from 11 representative crops which comprised apple, blueberry, broccoli, cabbage, cherry, crown daisy, hulled rice, Korean cabbage, potato, rice and watermelon. The extract was purified serially by liquid-liquid extraction (LLE) and silica solid phase extraction (SPE). For rice and hulled rice samples, n-hexane partition was additionally adopted to remove nonpolar interferences, mainly lipids. The residue levels were analyzed by HPLC with DAD, using $C_8$ column. LOQ (limit of quantitation) of pymetroizinie was 1 ng (S/N > 10) and MQL (method quantitation limit) was 0.01 mg/kg. Mean recoveries from 11 crop samples fortified at three levels (MQL, 10 ${\times}$ MQL and 50 ${\times}$ MQL) in triplicate were in the range of 83.1~98.5% with coefficients of variation (CV) of less than 10%, regardless of sample type, which satisfies the criteria of KFDA. The method established in this study could be applied to most of crops as an official and general method for analysis of pymetrozine residue.

A Sensitive, Efficient, and Cost-Effective Method to Determine Rotigotine in Rat Plasma Using Liquid-Liquid Extraction (LLE) and LC-MRM

  • Kim, Ji Seong;Jang, Yong Jin;Kim, Jin Hee;Kim, Jin Hwan;Seo, Jae Hee;Park, Il-Ho;Kang, Myung Joo;Choi, Yong Seok
    • Mass Spectrometry Letters
    • /
    • v.13 no.4
    • /
    • pp.146-151
    • /
    • 2022
  • Rotigotine (RTG) is a non-ergot dopamine agonist used to manage the early stage of Parkinson's disease (PD) as transdermal patch. However, the poor medication compliance of PD patients and skin issues related with repeated applications of RTG patches lead to the search for alternative formulations and it also requires appropriate analytical methods for their in vivo evaluation. Thus, here, a sensitive, efficient, and cost-effective method to determine RTG in rat plasma using liquid-liquid extraction (LLE) and multiple reaction monitoring was developed. The use of 20 µL of rat plasma for sample treatment, 8-OH-DPAT as the internal standard, and methyl tert-butyl ether as the LLE solvent in the present method gives it advantages over previous methods for the analysis of RTG in biological samples. The good analytical performance of the developed method was confirmed in specificity, linearity (the coefficient of determination ≥0.999 within 0.1-100 ng/mL), sensitivity (the lower limit of quantitation at 0.1 ng/mL), accuracy (81.00-115.05%), precision (≤10.75%), and recovery (81.00-104.48%) by following the FDA guidelines. Finally, the applicability test of the validated method to the in vivo evaluation of a RTG formulation showed that the present method is the only method which can be accurately applied to that longer than 24 hours, critical for the development of formulations with reduced dosing frequencies. Therefore, the present method could contribute to the development of new RTG formulations helpful to people suffering from PD.

Determination of Cholesterol in Milk and Dairy Products by High-Performance Liquid Chromatography

  • Oh, H.I.;Shin, T.S.;Chang, E.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.10
    • /
    • pp.1465-1469
    • /
    • 2001
  • A sensitive high-performance liquid chromatographic method was developed to determine the content of cholesterol in milk and dairy products. To optimize separation of cholesterol, mobile phases including acetonitrile:2-propanol (8:1, v/v), acetonitrile:methanol (3:1, v/v), and acetonitrile:methanoI:2-propanol (7:3: I, v/v/v) were compared. Acetonitrile/methanol/2-propanol was superior to the other mobile phase systems for separating cholesterol. Liquid-liquid extraction (LLE) of cholesterol was simplified using a non-polar solvent, hexane, to remove interfering compounds, and had an excellent recovery $(100{\pm}1.0%)$ of cholesterol. A solid phase extraction (SPE) method using Sep-pak $C_{18}$ was developed and compared with LLE. The SPE method was rapid and highly reproducible. Both extraction methods were useful when used in combination with saponification of esterified cholesterol to facilitate total cholesterol determination. The detection limit of cholesterol was $0.01{\mu}g$. The newly developed HPLC method was rapid, simple, and accurate, and has advantages over the many methods commonly used.

Simultaneous Determination of Antioxidant(BHA, BHT) and Insecticide(Fenvalerate, Allethrin) by Liquid Liquid Extraction-GC/MS (Liquid Liquid Extraction-GC/MS에 의한 항산화제(BHA, BHT) 및 살충제(Fenvalerate, Allethrin)의 동시분석)

  • Lee, Jae-Hee;Bae, Jun-Hyun;Kang, Jun-Gill;Kim, Youn-Doo
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.6
    • /
    • pp.559-568
    • /
    • 2003
  • A procedure based on liquid liquid extraction(LLE)-GC/MS has been developed for the simultaneous analysis of antioxidants and insecticides known as endocrine disrupters. The endocrine disrupters investigated in this study are butylated hydroxy anisole(BHA) and butylated hydroxy toluene(BHT), and the insecticides are allethrin and fenvalerate. The limit of detection(LOD) was 0.071~0.159 ng/ml with RSD of 1.41~5.34% for the standard sample. From water reservior of Han river, Geum river, Nakdong river and Sumjin river, these compounds were not detected. For the synthesized sample, the LOD is 0.051~0.132 ng/ml with RSD of 6.39~13.4%.

Studies on Pretreatment for Analysis of Pesticides by Using HPLC and GC (HPLC 및 GC에 의한 농약분석에서 전처리에 대한 연구)

  • Oh, Bo Young;Bae, Jun Hyun;Kang, Jun Gil;Kim, Youn Doo
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.6
    • /
    • pp.663-669
    • /
    • 1999
  • For determination of separated pesticides by using GC and HPLC, liquid-liquid extraction(LLE) and solid phase extraction(SPE) have been carried out to separate and concentrate the organophophorous pesticides such as Diazinon, Fenitrothion, Phosmet, Phosalon and EPN in environmental water samples. ln determination of pesticides by HPLC/UV, SPE has resulted in higher recovery and more precision than LLE, while in determination of pesticides by GC/FPD, vice versa. HPLC/UV after the pretreatment process of sample by solid phase extraction (SPE-HPLC/UV) has suggested the possibility of determination of pesticides ppb level. ln comparison of detection limit, both SPE-HPLC/UV and LLE-GC/FPD are reasonably suitable for analysis of residue pesticides. ln the respect of the rapidity and the solvent required, SPE-HPLC/UV method has proven to be superior to LLE-GC/FPD.

  • PDF

Comparative Study of Extracting Fragrance Allergens by GC-MS/MS

  • Lee, In Ja;Ahn, Jae-Chan;Kim, Bogsoon;Chung, Deukmo
    • Mass Spectrometry Letters
    • /
    • v.8 no.1
    • /
    • pp.18-22
    • /
    • 2017
  • Products containing any one or more of 26 fragrance allergens likely to cause contact allergies, are required under the 2008 domestic cosmetic law to be labeled when their concentrations exceed a certain range. This study focuses on the comparison and development of analytical methods based on headspace-solid phase micro extraction (HS-SPME) and liquid-liquid extraction (LLE) methods followed by GC-MS/MS for 24 of the fragrance allergens excepting for two natural materials in water samples. Using the developed HS-SPME method, 15 of the 24 fragrance allergens were analyzed and 9 compounds which have relatively low $logK_{OW}$ values (below about 2.5) were not extracted, and the correlation coefficient ($r^2$) of the calibration curve for quantification showed linearity of 0.9969 or more, and the method detection limits (MDL) and the limits of quantification (LOQ) were $0.078{\sim}0.582{\mu}g/L$ and $0.261{\sim}1.940{\mu}g/L$, respectively. In the case of using the optimized LLE method, all 24 fragrance allergens were analyzed, and the correlation coefficient ($r^2$) of the calibration curve for quantification showed linearity of 0.9957 or more, MDL and LOQ were $0.020{\sim}0.138{\mu}g/L$ and $0.065{\sim}0.440{\mu}g/L$, respectively.

The analysis of the urushiol congeners from the extracts of lacquer trees (옻나무 추출물 중 우루시올 동종체의 함량비 분석)

  • Cho, Yumi;Jung, Yu-Kyung;Kim, Jinsan;Lee, Joonbae;Paeng, Ki-Jung
    • Analytical Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.65-74
    • /
    • 2009
  • Active components of lacquer tree referred to as urushiol congeners, which are catechol derivatives with various alkyl or alkenyl substituents. The olefin side chains typically have one, two or three double bonds. In this study, the each congener's ratio analysis of extracts from korean lacquer tree are compared to the one from other asian lacquer tree. Extraction was performed using liquid-liquid extraction (LLE) method with soxhlet system from tree's bark and sap. Extracts were analyzed by reverse phase liquid chromatography and on-line electro spray ionization mass spectrometry (LC-MS/MS).

Evaluation of the Efficiency of Solvent Systems to Remove Acetic Acid Derived from Pre-pulping Extraction

  • Park, Seong-Jik;Moon, Joon-Kwan;Um, Byung-Hwan
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.5
    • /
    • pp.447-455
    • /
    • 2013
  • Hemicellulose extract obtained by pre-pulping extraction of woodchips, is very diluted acidic in nature. The major component responsible for this weak acidity is acetic acid, present in levels up to 5~10 g/L. Here, we report an exploratory study on the extract upgrading by reactive solvent extraction of acetic acid as well as ASPEN simulation. In this study, liquid-liquid equilibria for the ternary systems (water + acetic acid + ethyl acetate) were measured at the temperature of 298.15 K and 10 (pH = 2.02), 5 (pH = 2.17), and 1 (pH = 2.48) percent of acetic acid samples were used to carry out liquid-liquid extraction studies using ethyl acetate. In a one-stage batch experiment, 96.0% of acetic acid could be extracted for the solvent when the ratio of organic-to-aqueous phases is 4:1. For simulation results, they were used to estimate the interaction parameters between each of the three compounds of the systems studied for the NRTL and UNIQUAC models. The estimated interaction parameters were successfully used to predict the equilibrium compositions by the two models.