The mycolic acids and fatty acids of mycolic acid- containing bacteria in various types of fluids were analyzed using capillary gas chromatography and mass spectrometry. As model strains, Brevibacterium and Coryebacterium species, which have corynomycolic acids ill the range of $C_{32}C_{36}$ in the whole cell, were investigated. Optimized solvents extraction procedures for the mycolic acids and fatty acids from the culture fluids were: chloroform/methanol (1:2, v/v) as the first extraction solvents fur 4 h; and chlorofunuwater (1:1, v/v) as the second extraction solvents far 1 h. These conditions gave above 95% recovery yields fur mycolic acids from the culture fluids. The mycolic acid profile for the whole cells and the culture fluids were similar fur all the media tested. Thus, the procedure described here could be applied for the identification of mycolic acid-containing bacteria in fermentation broth or liquid from of foods.
Kim, Jae-Young;Kim, Tae-Seung;Hwang, Hye-Won;Oh, Shin-Young;Choi, Joon-Weon
Journal of the Korean Wood Science and Technology
/
v.40
no.3
/
pp.194-203
/
2012
1-Ethyl-3-methylimidazolium acetate known as efficient biomass pretreatment reagent was used for the extraction of lignin from rigida pine wood (pitch pine), which was called to ionic liquid lignin (ILL), and chemical structural features of ILL were compared with the corresponding milled wood lignin (MWL). The amounts of phenolic hydroxyl groups (Phe-OH) was determined to 10.0% for ILL and 7.2% for MWL, respectively, where those of methoxyl groups (OMe) were 4.9% for ILL and 11.0% for MWL, respectively. The weight average molecular weight (Mw) of ILL (3,995) were determined to ca. 1/2 of that of MWL (8,438) and polydispersity index (PDI: Mw/Mn) suggested that the lignin fragments were more uniform in the ILL (PDI 1.36) than in the MWL (PDI 2.64). The temperature (Tm) corresponding to maximum decomposition rate (Vm) of ILL ($306.6^{\circ}C$) was ca. $35^{\circ}C$ lower than that of MWL ($341.9^{\circ}C$), suggesting that ILL was thermally unstable than MWL, as evidence from the lower Tm for ILL. Moreover, the structural characteristics of ILL and MWL were confirmed by spectroscopic analyses (FT-IR and $^{13}C$-NMR), and these results indicated ionic liquid (1-ethyl-3-methylimidazolium acetate) was chemically or physically bound to ILL.
Defatted soybean, larvae of brown mealworm (Tenebrio molitor), and powdered pupae of silkworm (Bombyx mori) were fermented in solid and liquid forms using Aspergillus oryzae and Bacillus subtilis. The protein degradation rate (NDR) through solid fermentation was the highest in the fermented soybean control sample (54.69±6.54%), followed by silkworm pupae (34.82±5.99%) and brown mealworm larvae (30.54±3.80%). When these edible insects were fermented in liquid form, solid extraction yield was 37.73-46.88%, and protein yield was 47.47-63.02%. NDR of fermented liquid form products increased to 58.90, 52.62, and 50.13% for soybean, brown mealworm larvae, and silkworm pupae, respectively. SDS-PAGE of the liquid fermented products confirmed that microbial fermentation decomposed higher-molecular-weight proteins into small polypeptides. In vitro digestibility of liquid forms of edible insects increased by 1.26 to 1.53 times after fermentation. The protein solubility, foaming ability, and foam stability of liquid-fermented edible insects all tended to increase through fermentation.
In recent years, packed column has been widely used in separation processes, such as absorption, desorption, distillation, and extraction, in the petrochemical, fine chemistry, and environmental industries. Packed column is used as a contacting facility for gas-liquid and liquid-liquid systems filled with random packed materials in the column. Packed column has various advantages such as low pressure drop, economical efficiency, thermally sensitive liquids, easy repairing restoration, and noxious gas treatment. The performance of a packed column is highly dependent on the maintenance of good gas and liquid distribution throughout a packed bed; thus, this is an important consideration in a design of packed column. In this study, hydraulic pressure drop, hold-up as a function of liquid load, and mass transfer in the air, air/water, and air-NH3/water systems were studied to find the geometrical characteristic for raschig super-ring experiment dry pressure drop. Based on the results, design factors and operating conditions to handle noxious gases were obtained. The dry pressure drop of the random packing raschig super-ring was linearly increased as a function of gas capacity factor with various liquid loads in the Air/Water system. This result is lower than that of 35 mm Pall-ring, which is most commonly used in the industrial field. Also, it can be found that the hydraulic pressure drop of raschig super-ring is consistently increased by gas capacity factor with various liquid loads. When gas capacity factor with various liquid loads is increased from 1.855 to 2.323 kg-1/2 m-1/2 S-1, hydraulic pressure drop increases around 17%. Finally, the liquid hold-up related to packing volume, which is a parameter of specific liquid load depending on gas capacity factor, shows consistent increase by around 3.84 kg-1/2 m-1/2 S-1 of the gas capacity factor. However, liquid hold-up significantly increases above it.
This study attempted to set up reasonable extraction time of Omija that was put in water for the various components to soak out. Changes of free sugars, organic acids, reducing sugar, total acid and tannin in Omija with various extraction times were investigated (together with the analysis of each components in Omija fruit). 1. High Performance Liquid Chromatography showed fructose, glucose, and sucrose to be the major free sugars of the Omija fruit. Free sugars and reducing sugar value in Omija beverage increased gradually in according with the extraction time, and marked 75.6% per total free sugars and 82.1% per total reducing sugar at 12 hours. 2. Gas Chromatography showed lactic acid, oxalic acid, fumaric acid, levulinic acid, succinic acid, malic acid, citric acid and pyroglutamic acid to be the major organic acids of the Omija fruit. Organic acids and total acids value in Omija beverage increased gradually on proportion to extraction time, and marked 97.0% per total organic acids at 9 hours and 79.0% per total acids at 12 hours. 3. Tannin content in Omija beverage was increased when extraction time was longer but it showed a low percentage as compared with the reducing sugar and total acid. Tannin content marked 48.8% per total tannin at 12 hours. 4. Sensory evaluation revealed that !1 hours of extraction produced the best quality products based in taste, flavor, color and over-all acceptability, considering the data, it seems possible to conclude that the optimum of time for extraction of Omija to water is 9 hours.
Ahn, Eun Jeong;Lee, Hwa Shim;Kim, Byung Joo;Lee, Gae Ho
Analytical Science and Technology
/
v.28
no.6
/
pp.460-466
/
2015
An isotope dilution liquid chromatography tandem mass spectrometry was developed as a primary method for the quantitative analysis of cholesterol in infant formula. Cholesterol-d4 was used as an internal standard and spiked into the infant formula sample. In order to release cholesterol out of cholesteryl ester, which is cholesterol bound to fatty acids in infant formula, saponification was carried out. Saponification conditions were optimized with heating temperature, reaction time and the concentration of KOH. The optimum conditions were as follows; heating temperature was 70 ℃, reaction time was 180 min and the concentration of KOH was 0.8 mL of 8 M KOH for about 0.1 g infant formula sample. Extraction of cholesterol out of sample solution was carried out with hexane uisng liquid-liquid extraction. Chromatographic analysis was carried out using Phenomenex Kinetex C18 column. Mobile phase was 0.1% acetic acid in methanol/water (v/v, 99/1) and flow rate was 0.3 mL/min. Cholesterol and cholesterol-d4 were monitored at mass transfer m/z 369/259 and 373/263 respectively. Reproducibility of the method was evaluated to be 0.23% of the measurement result. The expanded uncertainty of the measurement result of cholesterol in infant formula was approximately 1.9% at a 95% confidence level. NIST standard reference material having certified values of cholesterol in infant formula, was analyzed in order to verify this method. The ID-LC/MS/MS results were well agreed with the certified values of NIST SRM within the uncertainty.
Lee, Chang-Heon;Kang, Chang-Hee;Kim, Eun-Kyung;Lee, Won
Analytical Science and Technology
/
v.7
no.1
/
pp.103-114
/
1994
The elution behaviors of Ni(II), Cu(II), Co(II), and Cr(II) in 1-phenyl-3-methyl-4(2-hydroxy-5-X-phenylazo)-5-pyrazolone, [Pm(2-OH)(5-X)PaPz](X=H, $CH_3$, $NO_2$, Cl) chelates have been studied by reversed phase HPLC. Thirteen metal-[Pm(2-OH)(5-X)PaPz] chelates were prepared and characterized by UV, IR, MS, and ICP spectroscopic methods. These metal-2-hydroxyarylazopyrazolone chelates were successfully separated on Novapak-$C_{18}$ column using methanol/water mixtures as a mobile phases. It was found that the chelates were eluted properly in an acceptable range of the capacity factor value($0{\leq}log\;k^{\prime}{\leq}1$). The dependence of the capacity factor(log k') on the volume fraction of water in the binary mobile phase showed a good linearity. Also, there was a good linear dependence of the capacity factor on the liquid-liquid extraction distribution ratio($D_c$) in methanol-water/n-pentadecane extraction system by the batch method. It suggested that the retention of the chelates in the reverse phase liquid chromatographic system be largely due to the solvophobic effect.
Kim In-Whan;Choi Gang-Yeol;Lee Man-Ho;Kang Chang-Hee;Lee, Won
Journal of the Korean Chemical Society
/
v.36
no.5
/
pp.697-708
/
1992
Liquid Chromatographic behavior of Ni(II) in Isonitrosoethylacetoacetate Imine(IEAA-NR), Ni(IEAA-NH)(IEAA-NR)(R = H, CH_3, C-2H_5, n-C_4H_9, C_6H_5-CH_2) chelates were investigated by reversed-phase HPLC on Micropak MCH-5 column using methanol/water as mobile phase. The optimum conditions for the separation of Ni(IEAA-NH)(IEAA-NR) chelates were examined with respect to the effect of the flow rate, sample solvent, mobile phase strength and column temperature. It was fo$und that metal chelates were properly eluted in an acceptable range of capacity factor value(0{\le}logk'{\le}1). The dependence of the logarithm of capacity factor (k') on the volume fraction of water in the binary mobile phase as well as on the liquid-liquid extraction distribution ratio (Dc) in methanol-water/n-alkane extraction system showed the good linearties, and the dependence of the logarithm of capacity factor (k') on the column temperature and on the enthalpy exhibited the good linearties, and the compensation temperature ({\beta}) from the slope was 773.47{\circ}K. It was suggested that the retention of metal chelates was largely affected by the hydrophobic effect.
Carbaryl and seven organophosphorous pesticides were analyzed simultaneously using on-line solid phase extraction (on-line SPE) coupled with liquid chromatography tandem mass spectrometry (LC/MS/MS). The target pesticides are Carbaryl, Methyl demeton, Fenitrothion, Malathion, Parathion, Phenthoate, Diazinon, and EPN. This method includes the direct injection of $500{\mu}L$ in the water sample, a 15 min separation period using a rapid resolution liquid chromatography system with on-line SPE, and detection through electrospray ionization (ESI) positive mode. The percentage of recovery of all pesticides ranged from 85.3 % to 100 %. This method showed an accuracy of ${\geq}90.0%$, possessing limits of detection and quantification within 0.05 to $0.28{\mu}g/L$ and 0.16 to $0.89{\mu}g/L$, respectively. The correlation coefficients (r) for the calibration curves within a range of 0.5 to $8.0{\mu}g/L$ were higher than 0.99. The evaluation results showed the efficacy of the method for all contents, and no pesticides were detected in the water quality sample.
Some iron(III)porphyrin complexes were prepared, and identified by the spectroscopic methods. Elution behavior of iron(III)porphyrin complexes was investigated by reversed-phase HPLC. The optimum conditions for the separation of iron(III)porphyrin complexes were examined with respect to flow rate and mobile phase strength. These complexes were successfully separated on NOVA-PAK $C_{18}$ column using methanol / water(95/5) for $[T_pCF_3PP)Fe(R)]$ and methanol / water (98/2) for $[(P)Fe(C_6F_5)]$ as a mobile phase. It was found that these complexes were largely eluted in an acceptable range of capacity factor value ($0{\leq}logk'{\leq}1$). The dependence of the capacity factor (k') on the volume fraction of water in the binary mobile phase as well as the dependence of k' on the liquid-liquid extraction distribution ratio$(D_c)$ in methanol-water / n-pentadecane extraction system showed a good linearity. It means that the retention of iron(III)porphyrin complexes on NOVA-PAK $C_{18}$ column is largely due to the solvophobic effect. Also, there was a good linear dependence of the capacity factor(k') on the column temperature and enthalpy calculated by van't Hoff plot. From these results, it was confirmed that the retention mechanism of iron(III)porphyrin complexes in reversed-phase liquid chromatography was invariant under the condition of various temperature, and the solvophobic binding process exhibited isoequilibrium behavior.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.