• 제목/요약/키워드: Liquid-Liquid Extraction

Search Result 1,074, Processing Time 0.028 seconds

Method for the Analysis of Polybrominated Biphenyls(PBBs) in Environmental Samples (환경시료 중 폴리브롬화비페닐(Polybrominated Biphenyls) 분석법)

  • Shin, S.K.;Kim, T.S.;Hwang, S.Y.;Lee, W.S.;Chung, Y.H.;Na, J.G.
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.300-316
    • /
    • 2002
  • The extraction methods of PBBs from environmental samples by soxhlet extraction for solid phase and liquid-liquid extraction for liquid phase were compared. After extraction, silicagel and florisil as column clean up methods were used for the comparison of cleanup efficiency with different solvent system. Also, the analytical instruments were used GC/MSD. The 22 kinds of PBBs standards were used to establish the analytical methods to perform the experiments of recoveries and detection limits in water and soil. The detection limits of PBBs represented 5~10 ng/L for water and 0.5~3.5 ng/g for soil samples, respectively. The recoveries of water samples represented 96~107% in n-hexane, dichloromethane and toluene for water, and 60~80% in combined solvent with n-hexane and acetone. The recoveries of soil sample were surveyed 67~97% in soxhlet extraction and 64~76% in ultrasonic extraction with selected solvents.

A Stable Supported Liquid membrane Composed of Polypropylene Glycol and Tributyl Phosphate for Phenol Separation from Aqueous Solution

  • Ahn, Hyo-Seong;Lee, Yong-Taek;Kim, Myung-Soo
    • Korean Membrane Journal
    • /
    • v.1 no.1
    • /
    • pp.81-85
    • /
    • 1999
  • Tributyl phyosphate(TBP) polypropylene glycol 4000(PPG-4000) and the mixture of two compounds were examined as a liquid membrane in a supported liquid membrane (SLM) to separate phenol from aqueous solution.The feed concentration of phenol was varied in a broad range from 500 mg/L to 5000 mg/L and different types of liquid membrane were prepared to elucidate their effects on separation of phenol. It was found that the modified PPG 4000 with TBP and toluene diisocyanate(TDI) might be used as a proper liquid membrane because the mass transfer rate examined with this membrane was higher than that through methyl isobutyl ketone (MIBK) which has been used as a conventional solvent in a solvent extraction process. The breakthrough pressure of the SLM is defined to be the pressure difference across the membrane at which the supported liquid membrane is not kept in the pores any more. it indicates how the SLM is stable., It was found that the breakthrough pressure of the modified PPG-4000 was much higher than those of typical organic solvents.

  • PDF

An Experimental Study on Freezing of Phase Change Material in a Cooled Vertical Tube (수직냉각관내에서 상변화물질의 응고에 관한 실험적 연구)

  • Lee J. M.;Lee C. M.;Yhim J. S.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.13 no.4
    • /
    • pp.223-229
    • /
    • 1984
  • Experiments were performed for freezing of an initially superheated or nonsuperheated liquid phase in a cooled vertical tube. The liquid was placed in a copper tube whose surface maintained a uniform temperature during the data run and the freezing occurred in a copper tube. The phase change medium was n-odtadecane, a paraffin which freezes at about $61^{\circ}C$. Measurements were made which yielded information about the time dependence of the freezing front, of the amount of frozen mass, and of the various energy components extracted from the tube. The time-wise decay of the initial liquid superheat was also measured. Initial superheat of the liquid tends to moderately diminish the rozen mass and associated latent energy extraction at small times but has lit tie effect on these quantities at large tiems. Natural convection in the liquid Plays a modest role only at small times and disappears when the superheat decay to zero. Although the latent energy constitutes the largest contributor to the total extracted energy, the sensible energy components can make a significant contribution, especially at large tube wall subcoolings, large initial liquid superheating and short freezing time.

  • PDF

Analysis of Anti-adipogenic Constituents of Cordyceps militaris Using High Performance Liquid Chromatography-Diode Array Detection in Different Samples: Comparison with Anti-adipogenic Activity

  • Liu, Qing;Hong, In-Pyo;Han, Sang-Bae;Hwang, Bang-Yeon;Lee, Mi-Kyeong
    • Natural Product Sciences
    • /
    • v.18 no.3
    • /
    • pp.171-176
    • /
    • 2012
  • We previously isolated cordycepin, guanosine and tryptophan from Cordyceps militaris as antiadipogenic constituents. For the quality control of C. militaris for anti-adipogenic activity, simultaneous analytical method using high-performance liquid chromatography (HPLC)-diode array detection (DAD) was developed and validated. Quantitation of these compounds in various Cordyceps samples from different sources and various extraction methods were conducted using developed method. Our study shows that natural Cordyceps and host insect possess higher content than cultured ones and fruiting bodies, respectively. The content of cordycepin showed great difference in different C. militaris samples whereas trytophan content was similar in tested samples. Addition of water to extraction solvent greatly increased the yield of guanosine and tryptophan. High temperature and longer extraction time increased yield of guanosine, whereas the content of trytophan was decreased in high temperature during extraction with water. Extraction using ultrasonic apparatus slightly increased extraction efficiency. Cordycepin, however, has little variation in different extraction method tested. Strong anti-adipogenic activity was observed in the samples that contain all the three constituents. Taken together, quantitation of these compounds using developed analytical method might provide basic requirement for the anti-adipogenic activity of C. militaris.

Effect of Oxidation Behavior of (Nd,Dy)-Fe-B Magnet on Heavy Rare Earth Extraction Process

  • Park, Sangmin;Nam, Sun-Woo;Lee, Sang-Hoon;Song, Myung-Suk;Kim, Taek-Soo
    • Journal of Powder Materials
    • /
    • v.28 no.2
    • /
    • pp.91-96
    • /
    • 2021
  • Rare earth magnets with excellent magnetic properties are indispensable in the electric device, wind turbine, and e-mobility industries. The demand for the development of eco-friendly recycling techniques has increased to realize sustainable green technology, and the supply of rare earth resources, which are critical for the production of permanent magnets, are limited. Liquid metal extraction (LME), which is a type of pyrometallurgical recycling, is known to selectively extract the metal forms of rare earth elements. Although several studies have been carried out on the formation of intermetallic compounds and oxides, the effect of oxide formation on the extraction efficiency in the LME process remains unknown. In this study, microstructural and phase analyses are conducted to confirm the oxidation behavior of magnets pulverized by a jaw crusher. The LME process is performed with pulverized scrap, and extraction percentages are calculated to confirm the effect of the oxide phases on the extraction of Dy during the reaction. During the L ME process, Nd is completely extracted after 6 h, while Dy remains as Dy2Fe17 and Dy-oxide. Because the decomposition rate of Dy2Fe17 is faster than the reduction rate of Dy-oxide, the importance of controlling Dy-oxide on Dy extraction is confirmed.

Monitoring and Development of Pretreatment Method for Perfluorinated Compounds in Fish Samples (어류에서의 과불화합물 분석을 위한 전처리법 확립 및 모니터링)

  • Heo, Jin-Ju;Lee, Ji-Woo;Kim, Seung-Kyu;Oh, Jeong-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.7
    • /
    • pp.485-494
    • /
    • 2013
  • An efficient extraction method was developed for the analysis of 16 perfluorinated compounds (PFCs) in fish samples. We compared the recoveries from the Ion-Pairing Extraction (IPE), Liquid-Liquid Extraction (LLE), Solid-Phase Extraction (SPE), IPE + SPE method with varying the injection time of the internal standard. As a result, IPE method with the internal standard before extraction was evaluated as the most effective pretreatment method. The RPM (Revolution Per Munite) and pH in IPE-before method were additionally adjusted and the more efficient pretreatment method was established. The total 33 fish samples including liver and gut samples were collected from Korean markets and analyzed PFCs with developed pretreatment method of this study. Total 16 PFC levels in fish samples ranged from ND to 1.67 ng/g with 100% detection frequency. The average PFCs concentrations of muscle, liver and gut samples from fish were compared and showed the following trend: liver (17.8 ng/g) > gut (13.3 ng/g) > muscle (1.67 ng/g). The PFC levels in fish samples were similar or lower than other available previous results of foreign studies.

A study of activity ratios of uranium isotope in the groundwater using liquid scintillation counter (액체섬광계수기를 이용한 지하수 내 우라늄 동위원소 측정법에 관한 연구)

  • Cho, Soo-Young;Song, Kyung-Sun;Lee, Kil-Yong;Yoon, Yoon-Yeol;Kim, Won-Baek;Ko, Kyung-Sok
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.146-151
    • /
    • 2012
  • An analytical method was developed for the measurement of uranium isotope in ground water using the liquid scintillation counting technique. A LKB Wallac Quantulus 1220 liquid scintillation counter (LSC) equipped with pulse shape analyzer (PSA) and a solvent extraction method were used for the measurement of uranium isotope in ground water samples. The effect of solution volume on the extraction efficiency was evaluated for 100 to 1000 mL solutions using a NIST standard reference material (NIST SRM 4321C). The effect of groundwater pH on the extraction efficiency was also investigated for pH ranging from 0.5 to 10. It was found that the extraction efficiency had a strong dependence on pH showing a maximum at pH 2. In contrast, the effect of groundwater volume on the extraction efficiency was negligible in the range investigated. According to the method, the extraction efficiency of uranium isotopes was near 96% and the lower detection limit for uranium was 0.018 Bq/L with the counting time of 300 min. The result of this study was also verified by the conventional ICP-MS measurement. It is demonstrated that the suggested method is valuable to the determination of the optimum extraction and measurement conditions for uranium in ground water. The method was successfully applied to the ground water at four locations near the Daejeon province. It was found that the uranium content and the isotopic ratio of $^{234}U/^{238}U$ at the locations ranged 0.59~6.69 Bq/L and 0.72~1.40, respectively.

Optimum Extraction Methods of Volatile Compounds in Beef Extract Powder (쇠고기 엑기스 분말 휘발성 성분의 최적 추출방법에 관한 연구)

  • Kim Hun;Cho Woo-Jin;Jeong Eun-Jeong;Ahn Jun-Suck;Lim Chi-Won;Yoo Young-Jae;Kim Kwang-Ho;Cha Yong-Jun
    • The Korean Journal of Food And Nutrition
    • /
    • v.17 no.4
    • /
    • pp.412-419
    • /
    • 2004
  • In odor to select optimum extraction methods of volatile compounds in beef extract powder(BEP) as basic data for the development of a new detection method of irradiated BEP, four extraction methods, such as solid phase microextraction with polar fiber(S-PD) and non-polar fiber(S-CD), purge and trap(P&T) and liquid liquid continuous extraction(LLCE) methods, were tested with gas chromatography/mass spectrometry method. A total of 106 volatile compounds including 22 hydrocarbons, 7 aldehydes, 6 ketones, 13 alcohols, 6 sulfur-containing compounds, 19 nitrogen-containing compounds, 6 aromatic compounds, 17 terpenes, 8 furans and 2 miscellaneous compounds were detected in BEP by four detection methods. The most compounds(62 compounds) were detected by S-PD method, followed by P&T(43), LLCE(38) and S-CD method(30). Among these methods, S-PD and P&T methods showed a complementary interrelationship to detect volatile compounds as S-PD method showed high detectabiltiy to all compound groups except hydrocarbons and ketones, which had high volatility and low molecular weight(less than RI 1200), but P&T method showed the contrary pattern to that of S-PD method. Moreover, the most of volatile compounds detected by S-CD and LLCE methods were also detectable by S-PD or/and P&T methods. Therefore, the simultaneous application of S-PD and P&T methods were selected as the optimum volatile extraction methods of BEP.

Separation of Two Amino Acids by Microemulsion Bulk Liquid Membrane

  • Salabat, Alireza;Sanij, Fereshteh Dehghani
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.10
    • /
    • pp.3387-3390
    • /
    • 2012
  • In this research work the potentialities of microemulsion bulk liquid membrane for the selective transport of L-tryptophan (L-Trp) and L-tyrosine (L-Tyr) are investigated at 298.15 K. Reversed micelle formed by sodium bis(2-ethylhexyl)sulfosuccinate (AOT) in dichloroethane, was used as mobile carrier to transport amino acids between a source and a receiving aqueous phase. The effects of pH, surfactant concentration and initial amino acid concentration on the extraction efficiency and transfer rate of the amino acids were studied. It is verified that for a mixture of two amino acids, L-Trp can be extracted selectively by using this type of the bulk liquid membrane with optimized condition.

Treatment of ground waters in a hollow-fibre liquid membrane contactor for removal of ions

  • Hossain, Md. M.
    • Membrane and Water Treatment
    • /
    • v.4 no.2
    • /
    • pp.95-108
    • /
    • 2013
  • Metal ions exist in seawater, groundwater and industrial wastewaters. These source waters can be recycled if their concentrations are reduced. A number of processes can be applied for this purpose. Liquid-liquid extraction is one of the promising methods. In this paper, experimental results are presented on the removal of Cr(VI) using Aliquat-336, a reactive carrier, in sunflower oil (a non-toxic solvent). The performance of this new system is compared with those of kerosene (a toxic solvent). The extent of removal of Cr(VI) from samples with high and low concentrations are presented. The process was upgraded to a bench-scale module that can selectively remove about 50-90% Cr(VI) from samples of groundwater. Thus this process can produce water within the acceptable range for recycling and for use in secondary purposes such as irrigation.