• Title/Summary/Keyword: Liquid ventilation

Search Result 44, Processing Time 0.026 seconds

Temperature Field Measurement of Ventilation Flow in a Vehicle Interior (TLC와 컬러화상처리를 이용한 자동차 실내 환기유동의 온도장 측정)

  • 윤정환;이상준;김기원
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.1
    • /
    • pp.120-128
    • /
    • 1997
  • The variations of the temperature field in a passenger compartment were measured by using a HSI true color image processing system and TLC(Thermochromic Liquid Crystal) solution. This temperature measurement technique was proved to be useful for analyzing the ventilation flow. The flow field in the passenger compartment was visualized using a particle streak method with pulsed laser light sheet. The temperature field and flow field in the passenger copartment were affected significantly by the ventilation mode. The panel-vent mode heating had shorter elapse time to reach a uniform temperature than the foot-vent mode under the same ventilation condition and nonuniformity inside the passenger compartment could be minimized effectively by using the bilevel heating mode. The temperature increase rate in the rear passenger compartment was iower than the front compartment, especially in the vicinity of the rear seat occupants' knee level.

  • PDF

Application of Open-type Liquid Culture for Large-scale Production of Mature Plus Tree of Eucalyptus pellita (개방형 액체대량배양 시스템을 통한 유칼리나무 펠리타 선발목의 대량증식)

  • Park, So-Young;Moon, Heung-Kyu;Kim, Yong-Wook;Kim, Seon-Ja;Yi, Jae-Seon
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.6
    • /
    • pp.650-655
    • /
    • 2008
  • In an attempt to establish the mass proliferation system, Eucalyptus pellita, a 5-year-old plus tree, was cultured with three different culture types in 1L vessels: solid culture without ventilation (conventional culture), liquid culture without ventilation and open-type liquid culture with forced ventilation. Then the culture scale was subsequently increased from 1L to 10L in vessel volume. After 4 weeks of 1L-scale culture, the best growth was obtained by culturing plantlets on open-type liquid culture, suggesting that the in vitro plantlets growth can be enhanced by liquid medium and ventilation. In open-type large scale culture in 10L vessel, plantlets growth resulted in a 370% increase in the number of nodes, 3.6 times increase in leaf expansion, and 3.3 times increase in shoot length, while the conventional culture suppressed shoot growth due to the callusing on the leaves and lack of $CO_2$. The results indicated that the open-type large scale culture system was effective for enhancing productivity by improving growth of the plantlets in clonally proliferated plus tree, Eucalyptus pellita.

Method to Derive the Optimal Vent Position when Flammable Liquid Leaks Based on CFD (CFD 기반 인화성 액체 누출 시 최적의 환기구 배치 도출 방안)

  • Eun-Hee Kim;Seung-Hyo An;Jun-Seo Lee;Byung-Chol Ma
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.1
    • /
    • pp.11-18
    • /
    • 2024
  • If flammable liquid leaks, vapor evaporated from the pool can cause poisoning or suffocation to workers, leading to secondary accidents such as fires and explosions. To prevent such damage, ventilation facilities shall be installed when designing indoor workplaces. At this time, the behavior varies depending on the characteristics of the leaked chemical, so it is necessary to select a suitable vent location according to the material. Therefore, 3D CFD simulations were introduced to derive optimal vent position and ventilation efficiency was quantitatively evaluated by vent position. At this time, assuming a situation in which flammable liquids leak at indoor workplaces to form pools, the concentration of vapor evaporated from pools was compared to derive the optimal vent position. As a result of research on toluene with high vapor density, ventilation efficiency was confirmed to be the highest at the upper supply-lower exhaust, and it is judged that introducing it can achieve about 3.7 times ventilation effect at the same maintenance cost. Through this study, it is expected that the workplace will be able to secure workers' safety by applying simulation results and installing ventilation ports.

Bubble size characteristics in the wake of ventilated hydrofoils with two aeration configurations

  • Karn, Ashish;Ellis, Christopher R;Milliren, Christopher;Hong, Jiarong;Scott, David;Arndt, Roger EA;Gulliver, John S
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.2
    • /
    • pp.73-84
    • /
    • 2015
  • Aerating hydroturbines have recently been proposed as an effective way to mitigate the problem of low dissolved oxygen in the discharge of hydroelectric power plants. The design of such a hydroturbine requires a precise understanding of the dependence of the generated bubble size distribution upon the operating conditions (viz. liquid velocity, air ventilation rate, hydrofoil configuration, etc.) and the consequent rise in dissolved oxygen in the downstream water. The purpose of the current research is to investigate the effect of location of air injection on the resulting bubble size distribution, thus leading to a quantitative analysis of aeration statistics and capabilities for two turbine blade hydrofoil designs. The two blade designs differed in their location of air injection. Extensive sets of experiments were conducted by varying the liquid velocity, aeration rate and the hydrofoil angle of attack, to characterize the resulting bubble size distribution. Using a shadow imaging technique to capture the bubble images in the wake and an in-house developed image analysis algorithm, it was found that the hydrofoil with leading edge ventilation produced smaller size bubbles as compared to the hydrofoil being ventilated at the trailing edge.

Assessment of hazardous substances and workenvironment for cleanrooms of microelectronic industry (전자산업 청정실의 작업환경 및 유해물질농도 평가)

  • Chung, Eun-Kyo;Park, Hyun-Hee;Shin, Jung-Ah;Jang, Jae-Kil
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.280-287
    • /
    • 2009
  • High-tech microelectronics industry is known as one of the most chemical-intensive industries. In Korea, Microelectronics industry occupied 38% of export and 16% of working employees work in microelectronics industry. But, chemical information and health hazards of high-tech microelectronics manufacturing are poorly understood because of rapid development and its penchant for secrecy. We need to investigate on chemical use and exposure control. We Site-visits to 6 high-tech microelectronics manufacturing company which have cleanroom work using over 1,000kg organic solvents (5 semi-conductor chips and its related parts company, 1 liquid crystal display (LCD)). We reviewed their data on chemical use and ventilation system, and measured TVOCs (Total Volatile Organic Compounds) and carbon dioxide concentration. All cleanroom air passed through hepa filters to acheive low particle levels and only 1 cleanroom uses carbon filters to minimize the organic solvents exposures In TVOC screening test, Cleanroom for semi-conductor chips and its related parts company with laminar down flow system (e.g. class 1~100) showed nondetectable level of TVOCs concentration, but Cleanroom for liquid crystal display (LCD) with conventional flow system (e.g. class 1,000~10,000) showed 327 ppm as TVOCs. Acetone concentration in cleanroom for Jig cleaning, LC Injection, Sealing processes were 18.488ppm (n=14), 49.762 ppm (n=15), 8.656 ppm (n=14) as arithmetric mean. Acetone concentration in cleanroom for LCD inspection process was 40ppm (n=55) as geometric mean, where the range was 7.8~128.7ppm and weakly correlated with ventilation rate efficiency(r=0.44, p<0.05). To control organic solvents in cleanrooms, chemical and carbon filters should be installed with hepa filters. Even though their volatile organic compounds concentration was not exceed to occupational exposure limits, considering of entrance limited cleanroom environment, long-term period exposure effects and adverse health effects of cleanroom worker need further reseach.

Evaluation of Parameters of Gas Exchange During Partial Liquid Ventilation in Normal Rabbit Lung (토끼의 정상 폐 모델에서 부분액체환기 시 가스교환에 영향을 주는 인자들에 대한 연구)

  • An, Chang-Hyeok;Koh, Young-Min;Park, Chong-Wung;Suh, Gee-Young;Koh, Won-Jung;Lim, Sung-Yong;Kim, Cheol-Hong;Ahn, Young-Mee;Chung, Man-Pyo;Kim, Ho-Joong;Kwon, O-Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.1
    • /
    • pp.14-23
    • /
    • 2002
  • Background: The opitmal ventilator setting during partial liquid ventilation(PLV) is controversial. This study investigated the effects of various gas exchange parameters during PLV in normal rabbit lungs in order to aid in the development of an optimal ventilator setting during PLV. Methods: Seven New-Zealand white rabbits were ventilated in pressure-controlled mode with the following settings; tidal volume($V_T$) 8 mL/kg, positive end-expiratory pressure(PEEP) 4 $cmH_2O$, inspiratory-to-expiratory ratio(I:E ratio) 1:2, fraction of inspired oxygen($F_TO_2$) 1.0. The respiration rate(RR) was adjusted to keep $PaCO_2$ between 35~45 mmHg. The ventilator settings were changed every 30 min in the following sequence : (1) Baseline, as the basal ventilator setting, (2) Inverse ratio, I:E ratio 2:1, (3) high PEEP, adjust PEEP to achieve the same mean inspiratory pressure (MIP) as in the inverse ratio, (4) High $V_T$, $V_T$ 15 mL/kg, (5) high RR, the same minute ventilation (MV) as in the High $V_T$. Subsequently, the same protocol was repeated after instilling 18 mL/kg of perfluorodecalin for PLV. The parameters of gas exchange, lung mechanics, and hemodynamics were examined. Results: (1) The gas ventilation(GV) group showed no significant changes in the $PaO_2$ at all phases. The $PaCO_2$ was lower and the pH was higher at the high $V_T$ and high RR phases(p<0.05). No significant changes in the lung mechanics and hemodynamics parameters were observed. (2) The baseline $PaO_2$ for the PLV was $312{\pm}$ mmHg. This was significantly lower when decreased compared to the baseline $PaO_2$ for GV which was $504{\pm}81$ mmHg(p=0.001). During PLV, the $PaO_2$, was significantly higher at the high PEEP($452{\pm}38$ mmHg) and high $V_T$ ($461{\pm}53$ mmHg) phases compared with the baseline phase. However, it did not change significantly during the inverse I:E ratio or the high RR phases. (3) The $PaCO_2$ was significantly lower at high $V_T$ and RR phases for both the GV and PLV. During the PLV, $PaCO_2$ were significantly higher compared to the GV (p<0.05). (4) There were no important or significant changes in of baseline and high RR phases lung mechanics and hemodynamics parameters during the PLV. Conclusion: During PLV in the normal lung, adequate $V_T$ and PEEP are important for optimal oxygenation.

Design and Development of Vent Relief Valve for Oxidizer Tank (산화제 탱크용 벤트릴리프밸브 설계 및 개발)

  • Koh, Hyeon-Seok;Han, Sang-Yeop
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.854-856
    • /
    • 2011
  • A vent relief valve for oxidizer tank has been designed for liquid propellant feeding system of the space launch vehicle. The vent relief valve ensures oxidizer tank ventilation during filling and its protection from overpressure after filling. Tank ventilation during filling is ensured by vent valve and tank protection is ensured by combined operation of relief valve and vent valve. Numerical analysis predicted that pneumatic behavior and dynamic characteristics met the valve requirements. After manufacturing the prototype model, we have been conducting the tests to evaluate the performance of the vent relief valve.

  • PDF

Evaluation of Capture Efficiencies of Push-Pull Hood Systems by Cross Draft Directions and Velocities Using Smoke Visualization Technique (기류 가시화기법을 이용한 방해기류 방향과 속도에 따른 푸쉬풀 후드 효율 평가)

  • Song, Se-Wook;Kim, Tae-Hyeung;Ha, Hyun-Chul;Kang, Ho-Gyung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.36-44
    • /
    • 2005
  • A push pull hood system is frequently applied to control contaminants evaporated from an open surface tank in recent years. Efficiency of push pull hood system is affected by various parameters, such as cross draft, vessel shapes, size of tanks surface, liquid temperature, and so on. Among these, velocity of cross draft might be one of the most influencing factor for determining the ventilation efficiency. To take account of the effect of cross draft velocities over 0.38m/s, a flow adjustment of ${\pm}$20% should be considered into the push and +20% into the pull flow system Although there are many studies about the efficiency evaluation of push pull hood system based on CFDs(Computational Fluid Dynamics) and experiments, there have been no reports regarding the influence of velocities and direction of cross-draft on push-pull hood efficiency. This study was conducted to investigate the influence of cross draft direction and velocities on the capture efficiency of the push-pull ventilation system. Smoke visualization method was used along with mock-up of push-pull hood systems to verify the ventilation efficiency by experiments. When the cross-draft blew from the same origins of the push flows, the efficiency of the system was in it's high value, but it was decreased significantly when the cross-draft came from the opposite side of push flows Moreover, the efficiency of the system dramatically decreased when the cross-draft of open surface tank was faster than 0.4m/s.

Analysis of Dynamic Characteristics and Performances of Vent-Relief Valve (산화제 벤트/릴리프 밸브의 동특성 해석 및 작동성능 분석)

  • Jang, Je-Sun;Koh, Hyeon-Seok;Han, Sang-Yeop;Lee, Kyung-Won
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.6
    • /
    • pp.70-77
    • /
    • 2011
  • A ventilation-relief valve performs as a safety-valve assembly for the liquid-propellant feeding system of space launch vehicle. This valve plays a role of relieving the vaporized propellants from propellant tanks during the filling and storing stages of propellants. Also it regulates to maintain the pressure of ullage volume of on-board propellant tanks within the safety-margin during the flight. The simulation model of ventilation-relief valve is designed with AMESim to predict and evaluate the dynamic characteristics and pneumatic behaviors of valve. To validate a valve simulation model, the simulation results of the opening and closing pressures and their operating durations of valve by AMESim analysis are compared with the results of mathematical methods. In addition, the results of internal flow simulation with FLUENT are utilized to improve the accuracy of valve-modeling. This study will serve as one of reference guides to enhance the developmental efficiency of ventilation-relief valves with the various operating conditionss, which shall be used in Korea Space Launch Vehicle-II.

A Study on Worker Exposure to Chromium and Degreasing Solvent at Eleetroplating Operation in Small Industry in Korea (우리나라 중소기업 도금공정 근로자의 크롬 및 세척제 폭로에 관한 연구)

  • Paik, Nam Won;Zong, Moon Shik;Lee, Hong Keun;Yun, Chung Ski;Ceong, Hoe Kyeong;Lee, Kyeong Hee;Lee, Na Roo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.110-126
    • /
    • 1993
  • Worker exposures to total chromium, hexavalent chromium (VI), sulfuric acid and alkaline dust at electroplating operations and worker exposures to trichloroethylene (TCE) and methyl chloroform (MCM) at degreasing operations in eleven small industrial plants were evaluated. Appropriate local exhaust ventilation systems for both operations were designed and recommended. Results of the study are summarized as follows ; 1. Out of 134 measurements for airborne hexavalent chromium concentrations, seven were exceeding the Korean occupational health standard of $50{\mu}g/m^3$ and 45 were exceeding the NIOSH standard of $1{\mu}g/m^3$. With an exception of one measurement, concentrations of total chromium were below the Korean standard of $500{\mu}g/m^3$. 2. Worker exposures to chromium were closely related to the existing control methods at the electroplating operations. Local exhaust systems, partial coverage of the tank surface, and antifoaming agents on liquid surface were adopted as control methods. 3. With an exception of one sample, airborne concentrations of sulfuric acid and alkaline dusts were below the applicable occupational heatlth standards. 4. Three plants indicated that airborne concentrations of TCE and MCM were exceeding the Korean standards. Other plants showed lower concentrations than the standards. It should be noted that generally, the activities and workloads on the day of surveys were less than normal. 5. Since the most existing ventilation systems did not satisfy the ACGIH criteria, the ventilation systems should be improved. Some examples for designing appropriate ventilation systems are presented.

  • PDF