• Title/Summary/Keyword: Liquid types

Search Result 879, Processing Time 0.026 seconds

Discussions on the Combustion Dynamics of RDE with Relevance to the Liquid Rocket Combustion Instability (RDE의 연소동역학 및 액체 로켓 연소 불안정과 연관성에 대한 고찰)

  • Choi, Jeong-Yeol
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.363-366
    • /
    • 2012
  • Detonative combustion is considered as a promising combustion mechanism for improving thermodynamic efficiency of power generation systems as a PGC, as well as high-speed propulsion systems. Among the various types of detonative combustion, RDE is fascinated by many researchers because of the simplicity and continuos operation characteristics. Present paper is an introduction to the physical and operational concept of RDE with a brief history of RDE researches and recent development activities. Additional discussions will devoted to the relevance to the tangential mode instabilities in liquid rocket engines and improvement of liquid rocket performance.

  • PDF

Development of Plate-type Fine Atomizing Nozzles for SI Engines with Intake-port Fuel Injection

  • Suzuki, Takashi;Tani, Yasuhide
    • Journal of ILASS-Korea
    • /
    • v.12 no.1
    • /
    • pp.45-57
    • /
    • 2007
  • This paper presents both experimental and numerical studies regarding nozzles used for the SI engine application, particularly for the intake-port fuel injection type. The atomization mechanism of the multi-hole plate nozzle was investigated experimentally. It was found that the nozzle design added turbulence into the liquid-film jet and the jet disintegrated rapidly. Based on the results, various plate types for the nozzle were developed and tested; six hole nozzle for liquid jet interaction, plate-type nozzle with flat duct channel, and the simpler structured nozzle. The spray characteristics of the prototype nozzles were examined experimentally while the internal flow of the nozzle was investigated computationally. It was shown that turbulent liquid-film was injected and atomization quality was improved by controlling the internal flow condition of the plate-type nozzle.

  • PDF

Development of Membrane Type Liquid Variable Compensator

  • Takahashi, Seiji;Ochiai, Makoto;Hayakawa, Yoshinori
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.183-185
    • /
    • 2002
  • Heavy ion and proton therapy necessitate range weeks, which are time consuming. Three types of variable compensator, membrane type liquid variable compensator, are proposed by some of the authors to overcome the difficulties, by those arbitrarily thickness distribution of compensator obtained from treatment planning is created at the site of treatment. None of the ideas, however, is yet realized. In this research, we are trying to construct prototype membrane-type liquid variable compensator. This variable compensator partitions air and liquid with elasticity membrane and changes the surface of the elasticity membrane with the thread. The air and oil move through holes to and from the out of beam side of two boxes in which they are contained. The boxes are made of Plexiglas(PMMA), the thread which is made of nylon, the elasticity film which is made from latex for the moment.

  • PDF

A Study of the Analyses of Pronunciation Errors and Teaching Method of Stop-liquid Sequences in English (영어 정지음-유음 연쇄체의 발음오류분석과 지도방안연구)

  • Kim, Ju-Hee;Park, Han-Sang
    • Proceedings of the KSPS conference
    • /
    • 2007.05a
    • /
    • pp.99-101
    • /
    • 2007
  • This study analyzes Korean middle school students' pronunciation errors of stop-liquid sequences in English. The results showed two typical errors: the insertion of a vowel between a stop and a liquid and the substitution of a liquid with a flap or vice versa. Those pronunciation errors seem to occur since English and Korean have different syllable structures and different types of liquids. A teaching material, which emphasizes no vowel insertion for a proper pronunciation of the consonant clusters, was designed to reduce Korean students' pronunciation errors. Errors were reduced substantially after a 50-minute class with the newly designed material.

  • PDF

Cooling characteristics of a Liquid cooler Using Thermoeletric Module (열전소자를 이용한 액체 냉각기의 냉각열전달 특성)

  • Park, Min-Young;Lee, Geun-Sik
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.197-202
    • /
    • 2007
  • In this study, the cooling characteristics of a liquid cooler using thermoelectric module was experimentally investigated. The experiment was conducted for various inner structures of liquid cooler (4 cases), hot fluid flow rates (0.15-0.25 L/min), number of T.E module (2, 4, 6 set), and the cooling water flow rates (200-600 cc/min) for both parallel and counter flow types. Among the results, better cooling performance geometry was selected. And experiment was also carried out to examine further enhancement of cooling performance by inserting coils (pitches: 0.2, 3, 6 mm) into the hot-fluid channel. Present results showed that the short serpentine type(case2) indicated the best cooling performance. In the case of coil pitch of 3 mm, the best cooling performance was shown, more than 10% increase of the inlet and outlet temperature difference, compared with the case of the cooler without coil. Consequently, the inserted coil pitch should be properly selected to improve cooling performance.

  • PDF

Dynamic Stability of Liquid in a Spherical Tank Covered with Membrane under Vertical Harmonic Excitation

  • Chiba, Masakatsu;Murase, Ryo;Nambu, Yohsuke;Komatsu, Keiji
    • International Journal of Aerospace System Engineering
    • /
    • v.2 no.2
    • /
    • pp.34-39
    • /
    • 2015
  • Experimental studies were conducted on the liquid sloshing characteristics in a spherical tank covered with a flexible membrane. A spherical acrylic tank with 145.2 mm in radius was used as a test tank, and it was half-filled with water. Silicon membranes with 0.2 mm thickness were used as a test membrane with plane or hemispherical types. The test tank was harmonically excited in a vertical direction by an electro-dynamic exciter. In this case, a parametric instability vibration comes up when the excitation frequency is twice the natural frequency. Parametric instability regions of natural modes were measured for three cases, i.e. liquid surface is free, covered with plane membrane and hemi-spherical membrane.

Development of Portable System for Measuring pH in Blood (휴대용 혈중pH 측정시스템의 구현)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF

Effect of Vortex Generator in Intake Pipe on the Moisture Concentration Distributions and Combustion Performance in a CI Engine (흡기관내 와류생성기가 압축착화엔진의 수분 농도 분포 및 연소성능 향상에 미치는 영향)

  • Jeong, Seok Hoon;Suh, Hyun Kyu
    • Journal of ILASS-Korea
    • /
    • v.23 no.4
    • /
    • pp.169-174
    • /
    • 2018
  • In this work, optimization of blade shape for the improvement of mixture formation and vortex of intake port was performed by numerically, and the combustion performance of CI engine with optimized blade shape was investigated. To achieve this, 3 types of blade shape were studied under the different air flow mass conditions and the numerical results were investigated in terms of humidification water, moisture concentration, and velocity distributions. Evaporated liquid mass was also compared under various test conditions to reveal the turbulent intensity in an intake port. It was observed that the optimized blade shape can improve the humidification water, moisture concentration, and velocity distributions of intake port inside. The evaporated liquid mass was also increased under the conditions with blade. Especially, low NOx emissions was observed with optimized blade condition.

THE TYPES AND CONTENTS OF SWEETENERS IN LIQUID ORAL MEDICINES (경구용 액체약에 함유된 감미제의 종류와 함량)

  • Hwang, Min-Sung;Kim, Jung-Wook;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.661-667
    • /
    • 2001
  • Though a consensus seems to exist about the regulation of the use of sugar-containing food, however. an unrecognized and significant supply of cariogenic carbohydrate remains in the form of sugar-containing liquid oral medicine to prevent dental caries. children who are taking long-term sugar-containing liquid medicine have an increased risk of developing dental caries. The aim of this study is to get the information about the sugars in liquid medicines prescribed for the children. To get the information, the number and date of all prescriptions of liquid medicines for one month at pediatric hospital of Seoul National University Hospital were investigated. From that data, the most frequently used pediatric oral liquid medicine is presented. Then, for the information of the type and contents of sweeteners in that preferred medicines, the manufacturers of each medicines were asked for the data of sugar types and contents, and the informations about the medicine contents were collected via facsimile. The most frequently used pediatric oral liquid medicine were followed as expectorant, purge, antibiotic, drug for iron deficiency anemia, sedative, antihistamine, anticonvulsant, NSAIDs in order. The mean value of sweetener content in liquid medicines was $52.3{\pm}22.4g/100ml$ and most frequently used sweetener is sucrose.

  • PDF

Novel Imidazolium Ionic Liquids Containing Quaternary Ammonium Iodide or Secondary Amine for Dye-sensitized Solar Cell

  • Seo, Dong-Wan;Lim, Young-Don;Lee, Soon-Ho;Ur, Soon-Chul;Kim, Whan-Gi
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2633-2636
    • /
    • 2011
  • A new type of ionic liquid based on N-(3-aminepropyl)imidazolium iodide, called IIQAI, which consists of imidazolium and quaternary ammonium salt, and APII-(hydroxyethyl, propyl, hexyl) were synthesized and used as ionic liquid in dye-sensitized solar cells. APII-hexyl is solid, whereas IIQAI, APII-(hydroxyethyl, propyl) are viscous liquids. The synthesized ionic liquid showed relative thermal stability compared to the commercial ionic liquid of DMII. Among them, IIQAI was more stable than the other ionic liquid because of the two salt groups. APII-hydroxyethyl, which contains two hydroxyl groups, showed low viscosity with good flow. New types of ionic liquids were examined by $^1H$-NMR spectroscopy, thermo gravimetric analysis (TGA). IIQAI enabled a solar energy conversion efficiency of 6.3%, which is slightly higher than that of the referenced (DMII, 6.2%).