• Title/Summary/Keyword: Liquid tube

Search Result 539, Processing Time 0.028 seconds

Performance Analysis of R-1270(Propylene) Refrigeration System Using Internal Heat Exchanger (내부 열교환기를 이용한 R-1270용 냉동시스템의 성능 분석)

  • Ku, Hak-Keun
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.36-42
    • /
    • 2014
  • This paper considers the influence of internal heat exchangers on the efficiency of a refrigerating system using R-1270. These internal heat exchangers(liquid-gas or suction-line heat exchangers) can, in some cases, yield improved system performance while in other cases they degrade system performance. A steady state mathematical model is used to analysis the performance characteristics of refrigeration system with internal heat exchanger. The influence of operating conditions, such as the mass flowrate of R-1270, inner diameter tube and length of internal heat exchanger, to optimal dimensions of the heat exchanger is also analyzed. The main results were summarized as follows : the mass flowrate of R-1270, inner diameter tube and length of internal heat exchanger, and effectiveness have the influences on the cooling capacity, compressor work and RCI(Relative Capacity Index) of this system. With a thorough grasp of it is possible to design the R-1270 compression refrigeration cycle using internal heat exchanger.

X-ray Micro-Imaging Technique and Its Application to Micro-Bubbles in an Opaque Tube (X-ray Micro-Imaging 기법 소개 및 불투명 튜브 내부의 마이크로 버블 가시화 연구)

  • Lee Sang-Joon;Kim Seok;Paik Bu-Geun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.31-34
    • /
    • 2002
  • Imaging techniques using x-ray beam at high energies (>6KeV) such as contact radiography, projection microscopy, and tomography have been used to nondestructively discern internal structure of objects in material science, biology, and medicine. This paper introduces the x-ray micro-imaging method using 1B2 micro-probe line of PAL (Pohang Accelerator Laboratory). Cross-sectional information on low electron density materials can be obtained by probing a sample with coherent synchrotron x-ray beam in an in-line holography setup. Living organism such as plants, insects are practically transparent to high energy x-rays and create phase shift images of x-ray wave front. X-ray micro-images of micro-bubbles of $20\~120\;{\mu}m$ diameter in an opaque tube were recorded. Clear phase contrast images were obtained at Interfaces between bubbles and surrounding liquid due to different decrements of refractive index.

  • PDF

Development of Prototype Liquid Scintillator System for Monitoring Liquid Radioactive Waste (배수 모니터링 액체섬광검출시스템의 프로토 타입 개발)

  • Nam, Uk-Won;Seon, Kwang-Il;Kong, Kyoung-Nam;Kim, Chang-Kyu;Lee, Dong-Myung;Lee, Sang-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.173-182
    • /
    • 2003
  • A prototype liquid scillatillator system for measurement of multiple beta-labeled mixtures was developed and its characteristic was investigated. The signal processing system consists of two photomultiplier tubes and the coincident count circuit. The characteristic of the system was analyzed using 4 beta-labeled samples $(^3H,\;^{14}C,\;^{36}Cl\;and\;^{90}Sr)$. Beta spectra from the samples were obtained without radiation shielding, and the detection limits for each nuclides were estimated based on the spectra. The estimated detection limits were compared to the legal regulation values. It is found that the liquid radioactive nuclides are detectable well below the legal regulation values.

Fabrication of TiO2 Nanowires Using Vapor-Liquid-Solid Process for the Osseointegration (골융합을 위한 Vapor-Liquid-Solid 법을 이용한 TiO2 나노와이어의 합성)

  • Yun, Young-Sik;Kang, Eun-Hye;Yun, In-Sik;Kim, Yong-Oock;Yeo, Jong-Souk
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.4
    • /
    • pp.204-210
    • /
    • 2013
  • In order to improve osseointegration for biomedical implants, it is crucial to understand the interactions between nanostructured surfaces and cells. In this study, $TiO_2$ nanowires were prepared via Vapor-Liquid-Solid (VLS) process with Sn as a metal catalyst in the tube furnace. Nanowires were grown with $N_2$ heat treatment with their size controlled by the agglomeration of Sn layers in various thicknesses. MC3T3-E1 (pre-osteoblast) were cultured on the $TiO_2$ nanowires for a week. Preliminary results of the cell culture showed that the cells adhere well on the $TiO_2$ nanowires.

A Study of the Device Development for the Contamination Detection in the Delivery Line (유체배관 오염 검출장치 개발에 관한 연구)

  • Jeong, Yi Ha;Kim, Byung Han;Hong, Joo-Pyo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.1
    • /
    • pp.45-49
    • /
    • 2015
  • Process gases with vapor or liquid phase as well as gas phase may experience alteration in itself or be contaminated in the fluid pipe to the process chamber. And thus it result in as particles or defects on the substrates in semiconductor, LCD, LED manufacturing. Purifiers and filters are used for control of contamination. However, none of detection device is available in the delivery line. In this paper, we propose simple device with lighting and sensing in order to predict contamination of the fluid or the tube wall. For some general purpose gases, it showed constant voltage output regardless of the flow rates. But, the smoke and the moisture in the air lowered the figure due to its concentration. Numerical values for several solid and liquid media were obtained. And, the operating temperature tendency was investigated.

Gas-liquid Chromatographic Analysis of Some Tropane Alkaloids

  • Paik, Nam-Ho;Im, Yong-Bin;Park, Man-Ki
    • YAKHAK HOEJI
    • /
    • v.20 no.3
    • /
    • pp.125-129
    • /
    • 1976
  • The aim of this investigation was to develop a quantitative gas-liquid chromatographic method of analysis forhyosyamine and scopolamine, and to apply this method to the analysis of preparations. The trimethylsily(TMS) derivatives of the alkaloids were found to be far superior to the nonsilylating compounds in charomatagrams. Bis(trimethylsilyl) acetamide(BSA) was evaluated and found to be a good reagent for silyation of the alkaloids. The optimum derivatization conditions were heating the alkaloids in a closed tube at $70^{\circ)$ for 30 min with a 150 molar excess of BSA to the alkaloids were found to be alkaloids. Calibration curves for the two alkaloids were alkaloid. The standard deviations were 1.1% for hyoscyamine and 1.5% for scopolamine. The minimum detectable amount using the hydrogen flame ionization edtector was determined to be 2$\times$10$^{-11}$ moles of each alkaloid injected.

  • PDF

A study on the boiling heat transfer of R-113 in a horizontal tube (수평관내 R-113 냉매의 비등열전달에 관한 연구)

  • 최병철;김원녕;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.67-77
    • /
    • 1986
  • The information on the heat transfer characteristics, flow pattern and pressure drop, are very important for the desing of general heat exchanger, refrigerating system, air conditioning system and energy recovery system. In these systems, water or lubricating oil contained in working fluid affects greatly the flow and heat transfer condition and this phenomena must be considered in the practical design. An experiment has been performed for studying the flow and heat transfer characteristics of the forced convective horizontal flow of R-113 under the range of the liquid single phase state to the boiling flow state. Basic experimental results are obtained in the case that water or lubricating oil does not contaminate in the test fluid. Experimental results are as follows; (1) The local heat transfer coefficients in the nucleate boiling region and transition boiling region are almostly ten times as large as that of liquid single phase flow. (2) The measured heat transfer coefficient in the present experimental range is relatively agreed well with the predicted value from the various experimental results for the boiling flow.

  • PDF

Size Measurements of Droplets Entrained in a Stagnant Bubbling Liquid Column

  • Jeong, Hae-Yong;No, Hee-Cheon;Song, Chul-Hwa;Chung, Moon-Ki
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.254-259
    • /
    • 1996
  • Phase Doppler particle analyze. (PDPA) is a instrument which can be used to obtain simultaneous size and velocity measurements in a multiphase flow. In this study, the size of the water droplets entrained from a bubbling surface of a stagnant liquid column is measured by PDPA with a specially designed transmitter of long focal length and large beam diameter. The test section tube is made of acryle with 18 mm I.D. and 900 mm length. The experimental data are obtained for the air superficial velocity between 0.7 m/s to 3.4 m/s at atmospheric pressure. The experimental results show that there exists large difference in the entrainment mechanism between the churn-turbulent flow and annular flow. Through the present study, the phase Doppler analyzer system is shown to be successfully applied to measure particle sizes larger than $2,000\mu\textrm{m}$ if a transmitter of long focal length is utilized.

  • PDF

Biodegradation of Toluene using Biofilms in a Bubble Column Bioreactor

  • Choi, Yong-Bok;Lee, Jang-Young;Kim, Hak-Sung
    • Journal of Microbiology and Biotechnology
    • /
    • v.5 no.1
    • /
    • pp.41-47
    • /
    • 1995
  • Biodegradation of toluene in liquid effluent stream was carried out using biofilms of Pseudomonas putida formed on celite particles in the bubble column bioreactor. Silicon rubber tubing was installed at the bottom of the bioreactor and liquid toluene was circulated within the tubing. Toluene diffused out of the tube wall and was transferred into the culture broth where degradation by biofilms occurred. The operating variables affecting the formation of biofihns on celite particles were investigated in the bubble column bioreactor, and it was found that formation of bifilm is favored by high dilution rate and supply rate of carbon source which stimulate the growth of initially attached cells. Continuous biodegradation of toluene using biofilms was stablely conducted in the bioreactor for more than one month without any significant fluctuation, showing a removal efficiency higher than 95% at the toluene transfer rate of 1.2 g/L/h.

  • PDF

Critical Properties of Bi Superconducting Wire with Cooling Condition in the Sintering Process. (후열처리 과정에서 냉각조건에 따른 Bi계 초전도선재의 임계특성)

  • 김민기;최효상;정동철;최명호;한병성
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.958-964
    • /
    • 1994
  • To study on the superconducting properties with cooling conditions, silver-sheathed Bi-Pb-Sr-Ca-Cu-O wires fabricated by the powder-in-tube method. The wires cooled down in the furnace, air and liquid NS12T after sintering at 840$^{\circ}C$ Critical current density of sample cooled in the furnace is 5.1${\times}$10S03TA/cmS02T and sample cooled in the air is 40A/cmS02T at 77K, zero magnetic field. The latter is very low critical current density of Bi system. 2223 high-Tc superconducting phase of sample cooled in the air was distroyed. Properties of sample cooled down in the liquid nitrogen is the same as cooled in the furnace.